CASE PRESENTATION: We present a successful aortic valve replacement with cardiopulmonary bypass in a 48 years old lady with antiphospholipid syndrome, who has severe aortic regurgitation as a result of Libman-sacks endocarditis. Antiphospholipid antibodies were positive and the clinical data showed both negative cultures and infective parameters. Surgically resected vegetations revealed sterile fibrinous and verrucous vegetations on aortic valve. Valve replacement and the course of cardiopulmonary bypass was uneventful, and the patient was discharged well.
CONCLUSIONS: Classically Libman-Sacks endocarditis is often and more commonly associated with autoimmune diseases such as systemic lupus erythematosus, although it can occur in both primary and secondary antiphospholipid syndrome. It is not a common entity, and it is a frequent underestimated disease as most clinicians do not routinely screen for valvular lesion in patients with antiphospholipid syndrome unless they are symptomatic. However, due to its high prevalence of cardiac involvement, clinicians should have a high index of suspicion in the attempt to minimize cardiovascular and haemodynamic complications. Valve surgery in patients with antiphospholipid syndrome carries considerable early and late morbidity and mortality, usually caused by thromboembolic and bleeding events. The perioperative anticoagulation management and haemostatic aspect of antiphospholipid syndrome present an exceptional challenges to clinicians, surgeons, anaesthetists and laboratory personnel.
CASE PRESENTATION: This is a case of a 37-year-old, right-hand dominant, Malay man who fell approximately 6 meters from a rambutan tree and his left arm hit the tree trunk on his way down. He was an active tobacco smoker with a 20 pack year smoking history. On clinical examination, Doppler signals over his radial and ulnar arteries were poor. He proceeded with emergency computed tomography angiogram of his left upper limb which showed non-opacification of contrast at the distal left brachial artery just before the bifurcation of the left brachial artery at his left elbow joint. Radiographs and computed tomography scan also showed undisplaced fracture of left lateral epicondyle and radial head with no evidence of elbow dislocation. He subsequently underwent left brachial to brachial artery bypass which was done using reversed saphenous vein graft and recovered well. His fractures were treated using 90 degree long posterior splint for 2 weeks and he was then allowed early range of motion of the left elbow. This patient developed left elbow dislocation 6 weeks postoperatively. Closed manipulative reduction of his left elbow resulted in incomplete reduction. The functional outcome of his left elbow was limited with a range of motion of left elbow of 0-45 degrees. However, he was not keen for surgery to stabilize his elbow joint during his last follow-up 6 months post injury.
CONCLUSIONS: This is an uncommon case of brachial artery injury in a civilian caused by blunt trauma associated with occult elbow instability/dislocation and minor fractures around the elbow joint. The treatment of brachial artery injury with clinical evidence of distal ischemia is surgical revascularization. The possibility of elbow instability and dislocation need to be considered in all cases of brachial artery injury because early radiographs and computed tomography scans may be normal. Short-term posterior splint immobilization is not sufficient to prevent recurrent dislocations.
METHODS: A cross-sectional study using self-developed survey form was conducted at 13 Medical Rehabilitation Clinics in Malaysia among 541 upper and lower limb amputees of any duration and cause.
RESULTS: The study population had a mean age of 54 years. Majority were males, Malays, married and had completed secondary school. About 70% of amputations were performed due to DM complications and at transtibial level. Fifty-eight percent of unilateral lower limb amputees were using prosthesis with a mean (standard deviation) of 6.48 (±4.55) hours per day. Time since amputation was the true factor associated with prosthesis usage. Longer hours of prosthesis use per day was positively correlated with longer interval after prosthesis restoration (r=0.467).
CONCLUSION: Higher aetiology of DM and lower prosthesis usage among amputees may be because of high prevalence of DM in Malaysia. The prosthesis usage and hours of use per day were low compared to the international reports, which may be influenced by sampling location and time since amputation. Nevertheless, this is a novel multicentre study on the characteristics and prosthesis usage of amputees. Hopefully, this research will assist to support, facilitate and promote prosthesis rehabilitation in Malaysia.
MATERIALS AND METHODS: The literature search was carried out on two electronic databases (PubMed and Cochrane Library). Randomized controlled trials (RCT) published from January 2011 to September 2022 were included. The bias risk was evaluated using Cochrane Risk of Bias Tool 2.0. Further screening was done for meta-analysis according to modified Newcastle-Ottawa scoring criteria. Forest plot was generated using a statistical method of inverse variance of random effect with 95% confidence interval.
RESULTS: A total of 8 randomized controlled trials were included for systematic review out of which four studies were based on tooth-supported fixed prosthesis and remaining four were based on implant-supported prosthesis. Further screening was conducted and three studies were eligible for meta-analysis. Tooth-supported fixed prosthesis fabricated from digital impression showed no significant difference in the marginal fit in any region measured, except for occlusal region where conventional impression showed more favorable marginal fit. Implant-supported prosthesis fabricated from digital impression showed survival rates ranging from 97.3 to 100% and there was no statistically significant difference in marginal bone loss (p = 0.14).
CONCLUSION: Implant-supported prostheses fabricated from digital and conventional impressions show no significant differences in their clinical outcomes. Tooth-supported fixed prostheses fabricated from digital impression have shown favorable findings in terms of marginal fit. Despite that, there is still lack of clinical trials with larger sample size and longer follow-up periods. Future studies that fulfill these two criteria are deemed necessary.
PATIENTS AND METHODS: Double-blind, randomised study involving 34 patients with either tremor-dominant Parkinson's disease or essential tremor. Patients were randomised to Group A (DBS leads inserted using conventional landmarks) or Group B (leads guided into the DRTT using DTIT). Tremor (Fahn-Tolosa-Marin) and quality-of-life (PDQ-39) scores were evaluated 0-, 6-, 12-, 36- and 60-months after surgery.
RESULTS: PSA-DBS resulted in marked tremor reduction in both groups. However, Group B patients had significantly better arm tremor control (especially control of intention tremor), increased mobility and activities of daily living, reduced social stigma and need for social support as well as lower stimulation amplitudes and pulse widths compared to Group A patients. The better outcomes were sustained for up to 60-months from surgery. The active contacts of Group B patients were consistently closer to the centre of the DRTT than in Group A. Speech problems were more common in Group A patients.
CONCLUSION: DTIT-guided lead placement results in better and more stable tremor control and fewer adverse effects compared to lead placement in the conventional manner. This is because DTIT-guidance allows closer and more consistent placement of leads to the centre of the DRTT than conventional methods.
METHODS: PCL grafts (1 mm ID/10 mm long) were implanted into the left common carotid artery in 20 Sprague-Dawley rats and compared to our previously published series of abdominal aortic implants. The animals were followed up to 3, 6, 12 and 24 weeks. At each time point, in vivo compliance, angiography and histological examination with morphology were performed.
RESULTS: PCL grafts showed good mechanical properties and ease of handling. The average graft compliance was 14.5 ± 1.7%/ mmHg compared to 7.8 ± 0.9% for the abdominal position and 45.1 ± 3.2%/ mmHg for the native carotid artery. The overall patency for the carotid position was 65% as compared to 100% in the abdominal position. Complete endothelialisation was achieved at 3 weeks and cell invasion was more rapid than in the aortic position. In contrast, intimal hyperplasia (IH) and vascular density were less pronounced than in the aortic position.
CONCLUSION: Our PCL grafts in the carotid position were well endothelialised with early cellular infiltration, higher compliance, lower IH and calcification compared to the similar grafts implanted in the aortic position. However, there was a higher occlusion rate compared to our abdominal aorta series. Anatomical position, compliance mismatch, flow conditions may answer the difference in patency seen.