Displaying publications 1 - 20 of 38 in total

Abstract:
Sort:
  1. Teo, B.H., Safinaz, M.K., Mae-Lynn, C.B., Amin, A., Edward, R., Mushawiahti, M.
    Medicine & Health, 2018;13(2):175-179.
    MyJurnal
    It is rare for anterior chamber migration of an Ozurdex® implant from vitreous cavity, but it is seen more frequently in aphakic eyes or in pseudophakic cases with zonular dehiscense. We describe a case of a middle-aged gentleman who had persistent diabetic macular oedema not responding to anti-VEGF (vascular endothelium growth factor), who was treated with intravitreal Ozurdex® in his post vitrectomized eye and developed anterior migration of the implant to the anterior chamber. Anterior dislocation of an intravitreal implant of dexamethasone can be managed by repositioning it to the vitreous cavity or removing it through a corneal limbal incision. Ozurdex® is a friable implant, especially after a few weeks of implantation. Therefore, removal of the implant by grasping or aspiration may lead to its fracture or dispersion of the implant material. This is a report of a simple,fast and effective technique to remove a migrated Ozurdex® from the anterior chamber using a modified silicone tip.
    Matched MeSH terms: Silicones
  2. Lee HY, Subramaniam N, Nordin MM
    Singapore Med J, 1996 Feb;37(1):55-60.
    PMID: 8783915
    To compare the advantages and disadvantages of the New Bird metal cups and silicone cups in terms of maternal and foetal outcome. To study the adverse effects and factors associated with failed vacuum deliveries.
    Matched MeSH terms: Silicones*
  3. Kosai, N.R., Aznan, M., Taher, M.M., Reynu, R.
    Medicine & Health, 2014;9(1):85-88.
    MyJurnal
    Breast augmentation using silicone implant is a common and popular aesthetic procedure with a high safety profile. Infection of silicone breast implants is a rare clinical entity, with skin commensal organisms often implicated as causative pathogen. Surgical treatment often involves removal of the implant with salvage procedures limited to selected cases. This case highlights a delayed presentation of an infected silicone breast implant presenting as a chest wall abscess 15 years after initial surgery.
    Matched MeSH terms: Silicones
  4. Salauddin SA, Ghazali H
    Malays J Med Sci, 2019 Nov;26(6):137-142.
    PMID: 31908595 MyJurnal DOI: 10.21315/mjms2019.26.6.14
    Background: Penile augmentation using injection of a foreign body into penile skin was mainly performed by non-medical personnel. Majority of these patients end up with complication of an abnormal mass formation known as penile paraffinoma.

    Methods: We described three different surgical techniques for correction of penile paraffinoma based on our single-centre experience. Informed consents were obtained from patients whose photographs were taken during the operation step.

    Results: In general, three patients had simple excision biopsy with primary suturing, four patients underwent single stage excision of circumferential granuloma with bilateral scrotal skin flap reconstruction and one patient experienced dual stage procedure. Three of them were injected with paraffin, one with silicone and the remaining four were unable to identify the substance used. All patients successfully underwent the surgical procedure and four of them had minor post-operative surgical site infection and wound gapping.

    Conclusion: All patients recovered well and the mean International Index of Erectile Function (IIEF-5) score obtained was 24.25. In our experience, excision biopsy was adequate for focal mass and reconstructive surgery using bilateral scrotal flap was suitable for circumferential mass.

    Matched MeSH terms: Silicones
  5. Norshamsiah, M.D., Muhaya, M., Bastion, M.L.C.
    MyJurnal
    A 24-year-old Chinese gentleman presented with two weeks history of sudden floaters in his right temporal visual field associated with blurring of vision. This ex-smoker also reported chronic, bloody cough for two years and recent pleuritic chest pain. Examination revealed a thin patient with right eye visual acuity of 6/18 associated with optic nerve dysfunction, optic disc swelling and macula star, retinal vasculitis and retinitis. Despite anti-tuberculosis medication and corticosteroids, he developed neovascularisation. Subsequent vitreous haemorrhage necessitated trans pars plana vitrectomy, membrane peeling, endolaser and silicone oil injection. Final visual acuity was 6/9 with quiescent retinopathy.
    Matched MeSH terms: Silicones
  6. Mustafa NA, Lope RJ, Cheah FC
    PMID: 16790731
    Matched MeSH terms: Silicones
  7. Bastion, M.L.C., Siti Aishah, S., Aida Zairani, M.Z., Barkeh, H.J.
    Medicine & Health, 2010;5(2):93-102.
    MyJurnal
    A retrospective case series review was conducted to determine the pre-operative role and safety of pre-operative adjunctive anti-vascular endothelial growth factor (anti- VEGF) agent ranibizumab “LUCENTISTM” in patients with diabetic retinopathy requiring vitrectomy. The study involved twenty consecutive eyes of sixteen patients (age range: 46-72 years; mean 57.5 years) which received intravitreal injection of 0.5 - 1 mg of ranibizumab 3 to 8 days (mean 4.4 days) prior to vitrectomy for diabetic retinopathy. There were no local or systemic post-injection complications. Indications for vitrectomy were retinal detachment (RD) [n=11; 3 combined tractional (TRD) - rhegmatogenous RD (RRD), 8 TRD], TRD with vitreous haemorrhage (VH) (n=3) ,VH (n=8) and vitreomacular traction syndrome (n=1). Inclusion criteria include all consecutive eyes of diabetic patients requiring vitrectomy receiving a first pre-operative injection of anti- VEGF. Pre-operative visual acuity (VA) ranged from 6/36 to light perception. All eyes had minimal to moderate intraoperative bleeding. Post-operative VH in eyes without tamponade or gas tamponade was nil (n=1), mild (n=13) or moderate (n=1). Silicone filled eyes had nil (n=1), moderate (n=3) or severe haemorrhages (n=1). Post-operative VA was unchanged (n=2) (10%), improved (n = 14) (70%) or worsened (n=4). VA was 2/60 or better (n=15) to no light perception (n=1). Two eyes achieved 6/12 or better vision (10%). Ten eyes (50%) had 6/36 or better vision. In conclusion, pre-operative intravitreal ranibizumab is safe and useful in diabetic vitrectomy and appears to help with perioperative bleeding leading to improvement in vision.
    Matched MeSH terms: Silicones
  8. Buzayan MM
    Prosthet Orthot Int, 2014 Feb;38(1):62-7.
    PMID: 23625838 DOI: 10.1177/0309364613484052
    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication.
    Matched MeSH terms: Silicones*
  9. Bin Sahadan MY, Tong WY, Tan WN, Leong CR, Bin Misri MN, Chan M, et al.
    Exp Eye Res, 2019 01;178:10-14.
    PMID: 30243569 DOI: 10.1016/j.exer.2018.09.011
    Microbial keratitis is the infection caused by pathogenic microorganisms that commonly occurs among the contact lens users. Various antimicrobial compounds were coated on contact lenses to kill keratitis causing microorganisms, however these compounds caused several adverse side effects. Hence, the aim of this study is to develop a silicone hydrogel contact lens coated with phomopsidione nanoparticle that inhibit keratitis causing clinical isolates. Phomopsidione nanoparticles were synthesized using polyvinyl alcohol as encapsulant. The nanoparticles showed an average size of 77.45 nm, with neutral surface charge. Two drug release patterns were observed in the drug release profile, which are the initial slow release phase with extended drug release (release rate 46.65 μg/h), and the burst release phase observed on Day 2 (release rate 2224.49 μg/h). This well-regulated drug delivery system enables the control of drug release to meet the therapeutic requirements. On agar diffusion assay, 3 out of 5 test microorganisms were inhibited by phomopsidione nanoparticle coated contact lenses, including two Gram negative bacteria. Besides, all test microorganisms showed at least 99% of growth reduction, with the treatment of the contact lens model. The drug loaded onto the nanoparticles is sufficient to prevent the bacterial growth. In conclusion, this study provides an effective alternative to combat keratitis-causing microorganisms among contact wearers.
    Matched MeSH terms: Silicones
  10. Inn FX, Imran FH, Ali MF, Ih R, Z Z
    Malays J Med Sci, 2012 Oct;19(4):81-3.
    PMID: 23613653 MyJurnal
    Throughout history, a proportion of men appear to correlate penis size and dimensions directly with physical fitness and sexual prowess. Foreign materials, such as paraffin oil, paraffin balm, mineral oils, and silicone, have been used to promise an improvement in penile shaft contour and dimensions. These materials are injected directly into the penis; inducing granuloma formation to achieve increased penis length and girth. However, the result is a severely disfigured and swollen penis, which cannot achieve erection. Local complications of penile lipogranuloma include infection, ulceration, local migration, and cavernosal invasion; leading to functional impairment. Meanwhile, systemic complications include foreign body embolization, organ infarct, and death. Penile lipogranuloma is best treated surgically. Granulomatous skin needs to be completely excised; wound closure with a scrotal skin flap, Cecil's inlay operation and split thickness skin graft commonly used options. Our case series has shown that penile lipogranuloma, induced by subcutaneous foreign body injections into the penile shaft, and its subsequent adverse outcomes to patients and their partners.
    Matched MeSH terms: Silicones
  11. Chai M, Tan G, Lal A
    Anal Sci, 2008 Feb;24(2):273-6.
    PMID: 18270422
    A headspace solid-phase microextraction method has been developed for the determination of 8 pesticides in vegetables and fruits by using gas chromatography with an electron capture detector. Two types of fibers (polyacrylate, 85 microm and polydimethylsiloxane, 100 microm) have been assayed and compared. The main factors: extraction and desorption parameters, ionic strength, and the effects of dilution and organic solvents, were studied and optimized. The optimized procedures resulted in more than 80% recovery for all the investigated vegetable and fruit samples with RSD values below 10%.
    Matched MeSH terms: Silicones/chemistry
  12. Al-Fakih E, Arifin N, Pirouzi G, Mahamd Adikan FR, Shasmin HN, Abu Osman NA
    J Biomed Opt, 2017 Aug;22(8):1-8.
    PMID: 28822140 DOI: 10.1117/1.JBO.22.8.087001
    This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction.
    Matched MeSH terms: Silicones*
  13. Xue Y, Zhang W, Lei Y, Dang M
    J Pharm Sci, 2020 05;109(5):1714-1724.
    PMID: 32007507 DOI: 10.1016/j.xphs.2020.01.022
    Olopatadine HCl is an antiallergic drug used for the management of allergic conjunctivitis. Currently, it is delivered via eye drop solution, which is highly inefficient due to low bioavailability. Silicone contact lenses can be used to sustain the release of ophthalmic drugs. However, the presence of drug alters the optical transmittance and physical properties of the contact lens. The objective was to design a novel polyvinyl pyrrolidone (PVP)-coated olopatadine-ethyl cellulose microparticles-laden doughnut contact lens to sustained ocular delivery with limited alteration to the optical and swelling properties of the contact lens. The doughnut was implanted within the periphery of the lens using modified casting technique. Olopatadine HCl was loaded by soaking (SM-OL), direct loading (DL-OL), and doughnut casting method (DNT-OL). PVP (comfort agent) was loaded on the surface of contact lens for all the batches via novel curing technique. The in vitro olopatadine HCl release data of SM-OL (up to 48-72 h) and DL-OL batches (up to 72 h) showed high burst release, whereas DNT-OL batch showed sustained release up to 120 h without significant (p > 0.05) alteration in the optical and swelling properties of contact lens. All the batches showed sustained release of PVP up to 120 h. The in vivo studies in the rabbit tear fluid showed improvement in the olopatadine HCl and PVP retention time in comparison to eye drop solution. The PVP-loaded DNT-OL-500 lens showed tear stabilization (comfort wear) in Schirmer strip test (rabbits) with no protein adherence in comparison to DNT-OL-500 lens without PVP. The study demonstrated the successful delivery of olopatadine HCl and PVP-K30 from the doughnut contact lens for the extended period with limited alteration to the optical and swelling properties of contact lens.
    Matched MeSH terms: Silicones
  14. Goh, W.N., Rosma, A., Kaur, B., Fazilah, A., Karim, A.A., Rajeev Bhat
    MyJurnal
    In this study, we evaluated and characterized microbial cellulose produced from Kombucha after eighth day of fermentation by employing SEM, FTIR, X-ray diffractometry, adsorption isotherm, and by measuring the swelling properties. Results on SEM revealed microbial cellulose layer to be composed of a compact cellulose ultrafine network like structure. FTIR spectra showed the presence of a characteristic region of anomeric carbons (960 – 730 cm-1), wherein a band at 891.59 cm-1 confirmed the presence of β, 1-4 linkages. Results of FTIR spectra also showed microbial cellulose to be free from contaminants such as lignin or hemicellulose, which are often present in plant cellulose. X-ray diffraction studies exhibited the overall degree of crystallinity index for MCC to be slightly lower than that of microbial cellulose. Results on swelling properties indicated microbial cellulose to possess higher fiber liquid retention values (10-160%) compared to commercial MCC (5-70%). The adsorption isotherm curves showed similarities between microbial cellulose with that of pure crystalline substance. Overall, results obtained in this study were comparable with the commercial microcrystalline cellulose, indicating that the process developed by us can be explored industrially on a pilot scale.
    Matched MeSH terms: Silicones
  15. Nam HY, Murali MR, Ahmad RE, Pingguan-Murphy B, Raghavendran HRB, Kamarul T
    Stem Cells Int, 2020;2020:5385960.
    PMID: 32908542 DOI: 10.1155/2020/5385960
    It has been suggested that mechanical strain may elicit cell differentiation in adult somatic cells through activation of epithelial sodium channels (ENaC). However, such phenomenon has not been previously demonstrated in mesenchymal stromal cells (MSCs). The present study was thus conducted to investigate the role of ENaC in human bone marrow-derived MSCs (hMSCs) tenogenic differentiation during uniaxial tensile loading. Passaged-2 hMSCs were seeded onto silicone chambers coated with collagen I and subjected to stretching at 1 Hz frequency and 8% strain for 6, 24, 48, and 72 hours. Analyses at these time points included cell morphology and alignment observation, immunocytochemistry and immunofluorescence staining (collagen I, collagen III, fibronectin, and N-cadherin), and gene expression (ENaC subunits, and tenogenic markers). Unstrained cells at similar time points served as the control group. To demonstrate the involvement of ENaC in the differentiation process, an ENaC blocker (benzamil) was used and the results were compared to the noninhibited hMSCs. ENaC subunits' (α, β, γ, and δ) expression was observed in hMSCs, although only α subunit was significantly increased during stretching. An increase in tenogenic genes' (collagen1, collagen3, decorin, tenascin-c, scleraxis, and tenomodulin) and proteins' (collagen I, collagen III, fibronectin, and N-cadherin) expression suggests that hMSCs underwent tenogenic differentiation when subjected to uniaxial loading. Inhibition of ENaC function resulted in decreased expression of these markers, thereby suggesting that ENaC plays a vital role in tenogenic differentiation of hMSCs during mechanical loading.
    Matched MeSH terms: Silicones
  16. Bradley DA, Dahlan KZ, Roy SC
    Appl Radiat Isot, 2000 Oct;53(4-5):921-8.
    PMID: 11003542
    High-energy electron (2.0 MV) and gamma irradiation (60Co) has been used to modify polymeric silicone fluids of initial viscosities in the range, 90-700 cSt. Doses of electron and gamma radiation were delivered at rates of 0.246 kGy s(-1) and 15 kGy h(-1), respectively, exposure times being adjusted to ensure energy deposition in the range 30-360 kGy. Measurements were made using a differential viscometer based on a Bose Institute design. In line with expectation, samples of greater initial molecular weight (and hence greater viscosity), were observed to be more susceptible to radiation induced cross-linking than those of lower molecular weight. The role of dose rate and oxygen diffusion in determining the extent of change is discussed.
    Matched MeSH terms: Silicones
  17. Sasidaran R, Zain MA, Basiron NH
    Urol Ann, 2012 Sep;4(3):181-6.
    PMID: 23248528 DOI: 10.4103/0974-7796.102672
    To report our experience with 5 cases of complications of penile enhancement procedures secondary to liquid silicone injections and our method of management of its debilitating effects. All five patients were treated with excision of penile shaft skin down to buck's fascia followed by resurfacing with split thickness skin grafting. We conclude that penile enhancement procedures with liquid silicone by non-medical personnel could result in devastating consequences. We also demonstrate that a simple method of excision of the entire penile shaft skin and resurfacing with split skin grafting showed improvement in cosmetic as well as functional outcome.
    Matched MeSH terms: Silicones
  18. Foo LC, Zainab T, Goh SY, Letchuman GR, Nafikudin M, Doraisingam P, et al.
    Biomed Environ Sci, 1996 Sep;9(2-3):236-41.
    PMID: 8886337
    A simple water iodizing system, which incorporates the Venturi principle in combination with the controlled release mechanism of a silicone-sodium iodide elastomer, for the iodization of rural piped-water supply in the control of endemic iodine deficiency has been developed and its effectiveness evaluated in three Iban longhouse villages in the iodine-deficient district of Lubok Antu, Sarawak. Urines were collected for iodine assays from women aged 15-40 years before and at 6 and 12 months after the connection of the iodinating device; goiter assessment was performed on the women at the start and end of the 1-year study. Water samples were collected for iodine assays at 2-weekly intervals. In all three villages, significant and sustained increases in median urinary iodine excretions, reaching levels recommended for an iodine-sufficient population, were observed; goitre prevalences were reduced in all the villages (by 22.6% to 35.8%). The iodine levels in the water ranged from 34 micrograms/l to 212 micrograms/L. In the control village, median urinary iodine excretions remained essentially unchanged but a small increase in goiter prevalence was observed. The iodized water was well received by the villagers and no adverse effects of water iodization were observed. The system functioned unattended throughout the one year period. The cost of providing supplemental iodine via the iodizing device is approximately 60 cents (U.S.) per family per year which is affordable by either the Government or the villagers. It is concluded that the iodizing system offers a new cost-effective strategy for the control of endemic iodine deficiency in Sarawak and may have applications in other areas with similar water sources.
    Matched MeSH terms: Silicones
  19. Bastion ML
    BMJ Case Rep, 2010;2010.
    PMID: 22242074 DOI: 10.1136/bcr.10.2009.2398
    The use of 0.5 mg/0.05 ml of ranibizumab intracamerally, to induce regression of iris neovascularisation in a non-diabetic patient, is reported. A 55-year-old Malay man presented with left eye rubeosis and hyphaema secondary to ischaemic remnant retinal flap in his silicone filled pseudophakic eye. Regression of rubeosis and resolution of hyphaema was noted within 4 days of injection of intracameral ranibizumab, allowing repeat vitrectomy to be performed without much bleeding, thus facilitating removal of his intraocular lens and laser to remaining flap. One month postoperatively he remained comfortable with counting fingers vision similar to the pre-hyphaema period.
    Matched MeSH terms: Silicones
  20. Nur Aqilah S, Farizal A, Othmaliza O
    MyJurnal
    Pyogenic granuloma of the eyes usually occurs after ocular surgery or inflammation related to the eyes, itself. This lesion is commonly related to procedures associated with chalazia, strabismus, or even enucleation. However, the incidence of pyogenic granuloma that arises directly from the lower canaliculi of the nasolacrimal system is rare and not being extensively reported. We report a case of an elderly lady who presented with pyogenic granuloma post EDCR with silicone stenting for left nasolacrimal duct obstruction. She presented with persistent left eye epiphora following procedure. The unusual site for pyogenic granuloma and it occurrence after EDCR raise the possibility that the condition is related to previous procedure and the material being used.
    Matched MeSH terms: Silicones
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links