Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Tan MK, Siddiqi A, Yeo LY
    Sci Rep, 2017 07 27;7(1):6652.
    PMID: 28751783 DOI: 10.1038/s41598-017-07025-x
    The Miniaturised Lab-on-a-Disc (miniLOAD) platform, which utilises surface acoustic waves (SAWs) to drive the rotation of thin millimeter-scale discs on which microchannels can be fabricated and hence microfluidic operations can be performed, offers the possibility of miniaturising its larger counterpart, the Lab-on-a-CD, for true portability in point-of-care applications. A significant limitation of the original miniLOAD concept, however, is that it does not allow for flexible control over the disc rotation direction and speed without manual adjustment of the disc's position, or the use of multiple devices to alter the SAW frequency. In this work, we demonstrate the possibility of achieving such control with the use of tapered interdigitated transducers to confine a SAW beam such that the localised acoustic streaming it generates imparts a force, through hydrodynamic shear, at a specific location on the disc. Varying the torque that arises as a consequence by altering the input frequency to the transducers then allows the rotational velocity and direction of the disc to be controlled with ease. We derive a simple predictive model to illustrate the principle by which this occurs, which we find agrees well with the experimental measurements.
    Matched MeSH terms: Torque
  2. Nur Syazwani Jarkasi, Zamberi Sekawi, Cheah, Yoke Kqueen, Zulkefley Othman
    MyJurnal
    Torque Teno Virus (TTV) is a human-infected virus that is present ubiquitously in nature. Globally, it infects up to 95% of the healthy individuals without any clinical manifestations. The widely used laboratory diagnosis of TTV infection is Polymerase chain reaction (PCR). Nevertheless, several other methods have been developed. The rapid growth of TTV variants over time has posed a challenge in estimating the global TTV infection as none of the PCR protocol has the ability to detect the entire spectrum of TTV variants. Multiple TTV epidemiological studies have been conducted among Asian population, whereas other continents showed a limited number of studies. The horizontal and vertical transmission of TTV among humans population, as well as interspecies transmission are potentially related to the global widespread of TTV infection.
    Matched MeSH terms: Torque teno virus
  3. Gharghan SK, Nordin R, Ismail M
    Sensors (Basel), 2015;15(5):11741-68.
    PMID: 26007728 DOI: 10.3390/s150511741
    In this paper, we propose an energy-efficient transmission technique known as the sleep/wake algorithm for a bicycle torque sensor node. This paper aims to highlight the trade-off between energy efficiency and the communication range between the cyclist and coach. Two experiments were conducted. The first experiment utilised the Zigbee protocol (XBee S2), and the second experiment used the Advanced and Adaptive Network Technology (ANT) protocol based on the Nordic nRF24L01 radio transceiver chip. The current consumption of ANT was measured, simulated and compared with a torque sensor node that uses the XBee S2 protocol. In addition, an analytical model was derived to correlate the sensor node average current consumption with a crank arm cadence. The sensor node achieved 98% power savings for ANT relative to ZigBee when they were compared alone, and the power savings amounted to 30% when all components of the sensor node are considered. The achievable communication range was 65 and 50 m for ZigBee and ANT, respectively, during measurement on an outdoor cycling track (i.e., velodrome). The conclusions indicate that the ANT protocol is more suitable for use in a torque sensor node when power consumption is a crucial demand, whereas the ZigBee protocol is more convenient in ensuring data communication between cyclist and coach.
    Matched MeSH terms: Torque
  4. Talib I, Sundaraj K, Hussain J, Lam CK, Ahmad Z
    Sci Rep, 2022 Sep 27;12(1):16086.
    PMID: 36168025 DOI: 10.1038/s41598-022-20223-6
    This study aimed to analyze anthropometrics and mechanomyography (MMG) signals as forearm flexion, pronation, and supination torque predictors. 25 young, healthy, male participants performed isometric forearm flexion, pronation, and supination tasks from 20 to 100% maximal voluntary isometric contraction (MVIC) while maintaining 90° at the elbow joint. Nine anthropometric measures were recorded, and MMG signals from the biceps brachii (BB), brachialis (BRA), and brachioradialis (BRD) muscles were digitally acquired using triaxial accelerometers. These were then correlated with torque values. Significant positive correlations were found for arm circumference (CA) and MMG root mean square (RMS) values with flexion torque. Flexion torque might be predicted using CA (r = 0.426-0.575), a pseudo for muscle size while MMGRMS (r = 0.441), an indication of muscle activation.
    Matched MeSH terms: Torque
  5. Murugan K, Faisham WI, Zulmi W
    Malays Orthop J, 2021 Mar;15(1):93-99.
    PMID: 33880154 DOI: 10.5704/MOJ.2103.014
    Introduction: Mega endoprosthesis replacement for resection of primary malignant bone tumour requires immediate and long-term stability, particularly in the young and active patient. Extracortical bone bridge interface (EBBI) is a technique whereby autograft is wrapped around the interface junction of bone and porous-coated implant to induce and enhance bone formation for biological incorporation. This procedure increases the mean torsional stiffness and the mean maximum torque, which eventually improves the implant's long-term survival.

    Material and methods: The extracortical bone bridge interface's radiological parameter was evaluated at the prosthesis bone junction two years after surgery utilising a picture archiving and communication system (PACS). The radiograph's anteroposterior and lateral view was analysed for both thickness and length in all four cortices. The analysis was done in SPSS Version 24 using One-Way ANOVA and independent T-Test. Results were presented as mean and standard deviation and considered significant when the p-value was < 0.05.

    Results: The mean average thickness was 2.2293mm (SD 1.829), and the mean average length was 31.95% (SD 24.55). We observed that the thickness and length of EBBI were superior in the young patient or patients with giant cell tumour that did not receive chemotherapy, compared to patients treated for osteosarcoma. The distal femur also had better EBBI compared to the proximal tibia. However, the final multivariable statistical analysis showed no significant difference in all variables. EBBI thickness was significantly and positively correlated with EBBI Length (p<0.001). We conclude that, for each 1mm increase in EBBI thickness, the length will increase by 0.06% on average. About 17.2% of patients out of the 29 showed no radiological evidence of EBBI.

    Conclusion: From our study, there were no factors that significantly contributed to the formation and incorporation of EBBI.

    Matched MeSH terms: Torque
  6. Talib I, Sundaraj K, Lam CK
    Sci Rep, 2019 11 07;9(1):16166.
    PMID: 31700129 DOI: 10.1038/s41598-019-52536-4
    This study aimed to quantify the association of four anthropometric parameters of the human arm, namely, the arm circumference (CA), arm length (LA), skinfold thickness (ST) and inter-sensor distance (ISD), with amplitude (RMS) and crosstalk (CT) of mechanomyography (MMG) signals. Twenty-five young, healthy, male participants were recruited to perform forearm flexion, pronation and supination torque tasks. Three accelerometers were employed to record the MMG signals from the biceps brachii (BB), brachialis (BRA) and brachioradialis (BRD) at 80% maximal voluntary contraction (MVC). Signal RMS was used to quantify the amplitude of the MMG signals from a muscle, and cross-correlation coefficients were used to quantify the magnitude of the CT among muscle pairs (BB & BRA, BRA & BRD, and BB & BRD). For all investigated muscles and pairs, RMS and CT showed negligible to low negative correlations with CA, LA and ISD (r = -0.0001--0.4611), and negligible to moderate positive correlations with ST (r = 0.004-0.511). However, almost all of these correlations were statistically insignificant (p > 0.05). These findings suggest that RMS and CT values for the elbow flexor muscles recorded and quantified using accelerometers appear invariant to anthropometric parameters.
    Matched MeSH terms: Torque
  7. Kondo E, Merican AM, Yasuda K, Amis AA
    Arthroscopy, 2014 Mar;30(3):335-43.
    PMID: 24581258 DOI: 10.1016/j.arthro.2013.12.003
    The purpose of this study was to clarify the changes in the kinematics of the knee that result from isolated deficiency of the anteromedial (AM) or posterolateral (PL) bundle.
    Matched MeSH terms: Torque
  8. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:134.
    PMID: 25208636 DOI: 10.1186/1475-925X-13-134
    Understanding of kinematics force applied at the elbow is important in many fields, including biomechanics, biomedical engineering and rehabilitation. This paper provides a comparison of a mathematical model of elbow joint using three different types of prosthetics for transhumeral user, and characterizes the forces required to overcome the passive mechanical of the prosthetics at the residual limb.
    Matched MeSH terms: Torque
  9. Hazwani Syaza Ahmad, Hanafi Ismail, Azura Abd Rashid
    Sains Malaysiana, 2015;44:835-842.
    Epoxidized natural rubber (ENR-50) has been used as a compatibilizer for natural rubber-recycled acrylonitrile-butadiene
    rubber (NR/NBRr) blends, vulcanized by sulfur. NBR gloves have excellent resistance to punctures, tear and many types
    of chemicals, while NR has good physical and mechanical properties. Incorporation of ENR-50 into the rubber blends
    has improved processability, stiffness, resilience and excellent oil resistance. NR/NBRr blends were prepared by two-roll
    mill with five different compositions with the ENR-50 content fixed at 10 phr. Cure characteristics, mechanical properties
    and morphology (SEM) studies were performed to determine the compatibility of NR/NBRr blends in the presence of ENR-
    50. The cure characteristics showed that NR/NBRr blends with the presence of ENR-50 have lower scorch time (ts2) and
    cure time (t90) than NR/NBRr blends without ENR-50. However, the NR/NBRr blends with ENR-50 exhibited higher minimum
    torque (ML
    ) and maximum torque (MH) which indicated difficult processability of the blends after compatibilization.
    Incorporation of ENR-50 into NR/NBRr blends improved all the tensile properties (tensile strength, tensile modulus and
    elongation at break) compared with NR/NBRr blends without ENR-50. The improvement in hardness upon compatibilization
    is due to an increase in crosslink density. Scanning electron microscopy (SEM images) of the fracture surfaces indicates
    that, with the addition of ENR-50 in NR/NBRr blends, better adhesion between NR and NBRr was obtained, thus improving
    the compatibility of NR/NBRr blends.
    Matched MeSH terms: Torque
  10. Uwamahoro R, Sundaraj K, Feroz FS
    Sensors (Basel), 2023 Sep 29;23(19).
    PMID: 37836995 DOI: 10.3390/s23198165
    Neuromuscular electrical stimulation plays a pivotal role in rehabilitating muscle function among individuals with neurological impairment. However, there remains uncertainty regarding whether the muscle's response to electrical excitation is affected by forearm posture, joint angle, or a combination of both factors. This study aimed to investigate the effects of forearm postures and elbow joint angles on the muscle torque and MMG signals. Measurements of the torque around the elbow and MMG of the biceps brachii (BB) muscle were conducted in 36 healthy subjects (age, 22.24 ± 2.94 years; height, 172 ± 0.5 cm; and weight, 67.01 ± 7.22 kg) using an in-house elbow flexion testbed and neuromuscular electrical stimulation (NMES) of the BB muscle. The BB muscle was stimulated while the forearm was positioned in the neutral, pronation, or supination positions. The elbow was flexed at angles of 10°, 30°, 60°, and 90°. The study analyzed the impact of the forearm posture(s) and elbow joint angle(s) on the root-mean-square value of the torque (TQRMS). Subsequently, various MMG parameters, such as the root-mean-square value (MMGRMS), the mean power frequency (MMGMPF), and the median frequency (MMGMDF), were analyzed along the longitudinal, lateral, and transverse axes of the BB muscle fibers. The test-retest interclass correlation coefficient (ICC21) for the torque and MMG ranged from 0.522 to 0.828. Repeated-measure ANOVAs showed that the forearm posture and elbow flexion angle significantly influenced the TQRMS (p < 0.05). Similarly, the MMGRMS, MMGMPF, and MMGMDF showed significant differences among all the postures and angles (p < 0.05). However, the combined main effect of the forearm posture and elbow joint angle was insignificant along the longitudinal axis (p > 0.05). The study also found that the MMGRMS and TQRMS increased with increases in the joint angle from 10° to 60° and decreased at greater angles. However, during this investigation, the MMGMPF and MMGMDF exhibited a consistent decrease in response to increases in the joint angle for the lateral and transverse axes of the BB muscle. These findings suggest that the muscle contraction evoked by NMES may be influenced by the interplay between actin and myosin filaments, which are responsible for muscle contraction and are, in turn, influenced by the muscle length. Because restoring the function of limbs is a common goal in rehabilitation services, the use of MMG in the development of methods that may enable the real-time tracking of exact muscle dimensional changes and activation levels is imperative.
    Matched MeSH terms: Torque
  11. Gautam Sarkhel, Sanjay Manjhi
    Sains Malaysiana, 2013;42:495-501.
    Industrial pollution issue and dark colour of carbon black, clay based non black filler are getting more importance for reinforcing elastomer. EPDM-Kaolin composites with various maleated EPDM concentration have been prepared by mixing on a two roll mill. The rheometry data showed the optimum cure time increases with increasing compatibilizer concentration without decreasing torque value indicating that acidic functional groups comes from compatibilizer could retard cure rate and increase the optimum cure time rather than change in the ultimate cure state. As the filler
    concentration increases, the edge to edge and face to edge interaction between filler and EPDM increases and the free volume between EPDM molecules is reduced, the storage modulus increases. Moreover, the dynamic mechanical analysis also showed the increase in glass transition temperature with increase in filler concentration due to the inter-tubular diffusion of EPDM inside the clay. It was also observed that with increasing filler concentration, the resistivity and dielectric strength decreases and moreover with increasing compatibilizer concentration the resistivity decreases due to better dispersion of filler helps to build conduction path. The morphological study also revealed that homogeneity of filler dispersion increases with increase in compatibilizer concentration.
    Matched MeSH terms: Torque
  12. Mohd Salim NS, Umar MA, Shaharudin S
    J Taibah Univ Med Sci, 2018 Dec;13(6):576-581.
    PMID: 31435381 DOI: 10.1016/j.jtumed.2018.10.007
    Objectives: The isokinetic evaluation of the ankle joint is important in determining the effectiveness of the rehabilitation programme for the management of ankle sprains. This study aimed to determine the effects of physiotherapy programme on isokinetic variables in individuals with grade I ankle sprains.

    Methods: Seven patients with acute grade 1 ankle sprain (15 days of ankle sprain) were recruited. They were provided with 7 days of protection, optimal loading, ice, compression, and elevation (POLICE) treatment, and the standard physiotherapy programme consisted of towel stretching and balancing exercises on one leg. Pain scale score was recorded daily during the physiotherapy programme. The isokinetic ankle strengths of the patient's injured and uninjured legs were compared before and after the physiotherapy programme. Isokinetic tests were conducted in painless range of motion for the injured leg.

    Results: Pain was significantly reduced after the patients underwent the standard physiotherapy programme. No significant differences were observed in terms of the ankle peak torque, time to peak torque, and ankle plantar flexion-to-dorsiflexion ratio of the injured and uninjured legs. The injured leg showed significant improvement in terms of ankle eversion-to-inversion ratio (E:I) after 7 days of performing the standard physiotherapy programme.

    Conclusion: Performing the standard physiotherapy programme for 1 week reduces pain and improves the ankle E:I in patients with grade 1 ankle sprain.

    Matched MeSH terms: Torque
  13. Naeem J, Hamzaid NA, Azman AW, Bijak M
    Biomed Tech (Berl), 2020 Aug 27;65(4):461-468.
    PMID: 32304295 DOI: 10.1515/bmt-2019-0191
    Functional electrical stimulation (FES) has been used to produce force-related activities on the paralyzed muscle among spinal cord injury (SCI) individuals. Early muscle fatigue is an issue in all FES applications. If not properly monitored, overstimulation can occur, which can lead to muscle damage. A real-time mechanomyography (MMG)-based FES system was implemented on the quadriceps muscles of three individuals with SCI to generate an isometric force on both legs. Three threshold drop levels of MMG-root mean square (MMG-RMS) feature (thr50, thr60, and thr70; representing 50%, 60%, and 70% drop from initial MMG-RMS values, respectively) were used to terminate the stimulation session. The mean stimulation time increased when the MMG-RMS drop threshold increased (thr50: 22.7 s, thr60: 25.7 s, and thr70: 27.3 s), indicating longer sessions when lower performance drop was allowed. Moreover, at thr70, the torque dropped below 50% from the initial value in 14 trials, more than at thr50 and thr60. This is a clear indication of muscle fatigue detection using the MMG-RMS value. The stimulation time at thr70 was significantly longer (p = 0.013) than that at thr50. The results demonstrated that a real-time MMG-based FES monitoring system has the potential to prevent the onset of critical muscle fatigue in individuals with SCI in prolonged FES sessions.
    Matched MeSH terms: Torque
  14. Ibitoye MO, Hamzaid NA, Abdul Wahab AK, Hasnan N, Olatunji SO, Davis GM
    Sensors (Basel), 2016 Jul 19;16(7).
    PMID: 27447638 DOI: 10.3390/s16071115
    The difficulty of real-time muscle force or joint torque estimation during neuromuscular electrical stimulation (NMES) in physical therapy and exercise science has motivated recent research interest in torque estimation from other muscle characteristics. This study investigated the accuracy of a computational intelligence technique for estimating NMES-evoked knee extension torque based on the Mechanomyographic signals (MMG) of contracting muscles that were recorded from eight healthy males. Simulation of the knee torque was modelled via Support Vector Regression (SVR) due to its good generalization ability in related fields. Inputs to the proposed model were MMG amplitude characteristics, the level of electrical stimulation or contraction intensity, and knee angle. Gaussian kernel function, as well as its optimal parameters were identified with the best performance measure and were applied as the SVR kernel function to build an effective knee torque estimation model. To train and test the model, the data were partitioned into training (70%) and testing (30%) subsets, respectively. The SVR estimation accuracy, based on the coefficient of determination (R²) between the actual and the estimated torque values was up to 94% and 89% during the training and testing cases, with root mean square errors (RMSE) of 9.48 and 12.95, respectively. The knee torque estimations obtained using SVR modelling agreed well with the experimental data from an isokinetic dynamometer. These findings support the realization of a closed-loop NMES system for functional tasks using MMG as the feedback signal source and an SVR algorithm for joint torque estimation.
    Matched MeSH terms: Torque
  15. Zulfikri N, Selvanayagam VS, Yusof A
    J Sport Rehabil, 2021 Jan 19;30(5):717-724.
    PMID: 33465761 DOI: 10.1123/jsr.2019-0483
    CONTEXT: Badminton continues to be a highly competitive sport where training is introduced at an early age and load has intensified. This exposes players to a greater risk of injuries, in particular when assessing related training outcomes such as strength, agonist-antagonist ratio, and bilateral deficit among adolescents where age- and sex-associated growth and development should be considered.

    OBJECTIVE: To evaluate strength profile of the upper and lower limbs among adolescent elite Malaysian badminton players.

    DESIGN: Cross-sectional study.

    SETTING: Laboratory.

    PARTICIPANTS: Forty-eight asymptomatic athletes (24 males and 24 females) were grouped into early and late adolescence (13-14 y old and 15-17 y old, respectively).

    MAIN OUTCOME MEASURE(S): Strength (absolute and normalized) of the external/internal rotators of the shoulder and flexor/extensor of the knee and strength derivatives, conventional strength ratio (CSR), dynamic control ratio (DCR), and bilateral deficits were measured.

    RESULTS: Males showed greater strength in all strength indices (P < .05). The older group had greater strength compared to younger for most of the upper and lower limb indices (P < .05); these effects diminished when using normalized data. For females, there was no age group effect in the shoulder and knee strength. All players displayed lower shoulder and knee normative values for CSR and DCR. Dominant and non-dominant knee strength were comparable between sex and age groups.

    CONCLUSIONS: For males, growth and maturation had a greater contribution to strength gained compared to training, whereas for females, growth, maturation, and training did not improve strength. The normalized data indicated that training did not improve all indices measured apart from external rotator strength in females. All players also displayed lower normative values of CSR and DCR. These results suggest that training in elite adolescent Malaysian badminton players lacks consideration of strength gain and injury risk factors.

    Matched MeSH terms: Torque
  16. Kamarul T, Ahmad TS, Loh WY
    J Orthop Surg (Hong Kong), 2006 Aug;14(2):172-7.
    PMID: 16914783
    To measure the hand grip strength of Malaysians aged 18 to 65 years.
    Matched MeSH terms: Torque
  17. Mortaza N, Abu Osman NA, Jamshidi AA, Razjouyan J
    PLoS One, 2013;8(5):e64308.
    PMID: 23717593 DOI: 10.1371/journal.pone.0064308
    Use of functional knee braces has been suggested to provide protection and to improve kinetic performance of the knee in Anterior cruciate ligament(ACL)-injured patients. However, many athletes might refrain from wearing the braces because of the fear of performance hindrance in the playing field. The aim of this study was to examine the effect of three functional knee brace/sleeves upon the isokinetic and functional performance of ACL-deficient and healthy subjects. Six anterior cruciate ligament deficient (29.0 ± 5.3 yrs., 175.2 ± 5.4 cm, and 73.0 ± 10.0 kg) and six healthy male subjects (27.2 ± 3.7 yrs., 176.4 ± 6.4 cm, and 70.3 ± 6.9 kg) were selected. The effect of a custom-made functional knee brace, and two neoprene knee sleeves, one with four metal supports and one without support were examined via the use of isokinetic and functional tests in four sets (non-braced,wearing functional knee brace,and wearing the sleeves). Cross-over hop and single leg vertical jump test were performed and jump height, and hop distance were recorded. Peak torque to body weight ratio and average power in two isokinetic velocities(60°.s(-1),180°.s(-1)) were recorded and the brace/sleeves effect was calculated as the changes in peak torque measured in the brace/sleeves conditions, expressed as a percentage of peak torque measured in non-braced condition. Frequency content of the isokinetic torque-time curves was also analyzed. Wilcoxon signed rank test was used to compare the measured values in four test conditions within each control and ACL-deficient group,and Mann-Whitney U test was used for the comparison between the two groups. No significant differences in peak torque, average power, torque-time curve frequency content, vertical-jump and hop measurements were found within the experimental and the non-braced conditions (p>0.05). Although the examined functional knee brace/sleeves had no significant effect on the knee muscle performance, there have been some enhancement regarding the extension peak torques and power generating capacity of the ACL-deficient subjects that could be helpful in reducing the bilateral asymmetry in these patients.
    Matched MeSH terms: Torque
  18. Tan CE, Fok MW, Luk KD, Cheung KM
    J Orthop Surg (Hong Kong), 2014 Aug;22(2):224-7.
    PMID: 25163961
    PURPOSE. To evaluate the insertion torque and pullout strength of pedicle screws with or without repositioning. METHODS. 20 fresh porcine lumbar vertebrae of similar size were used. The entry point was at the site just lateral and distal to the superior facet joint of the vertebra, and to a depth of 35 mm. A 6.2-mm-diameter, 35-mm-long pedicle screw was inserted parallel to the superior end plate on one side as control. On the other side, an identical screw was first inserted 10º caudal to the superior end plate, and then repositioned parallel to the superior end plate. The insertional torque and pullout strength were measured. RESULTS. Three of the specimens were excluded owing to pedicle fractures during the pullout test. Repositioned pedicle screws were significantly weaker than controls in terms of the maximum insertional torque (3.20 ± 0.28 vs. 2.04 ± 0.28 Nm, 36% difference, p<0.01) and pullout strength (1664 ± 378 vs.1391 ± 295 N, p<0.01). CONCLUSION. Repositioning pedicle screws should be avoided, especially when the pedicle wall is breached. If repositioning is deemed necessary, augmentation with polymethyl methacrylate or a screw with a larger diameter should be considered.
    Matched MeSH terms: Torque
  19. Altalmas T, Aula A, Ahmad S, Tokhi MO, Akmeliawati R
    Assist Technol, 2016;28(3):159-74.
    PMID: 27187763 DOI: 10.1080/10400435.2016.1140688
    Two-wheeled wheelchairs are considered highly nonlinear and complex systems. The systems mimic a double-inverted pendulum scenario and will provide better maneuverability in confined spaces and also to reach higher level of height for pick and place tasks. The challenge resides in modeling and control of the two-wheeled wheelchair to perform comparably to a normal four-wheeled wheelchair. Most common modeling techniques have been accomplished by researchers utilizing the basic Newton's Laws of motion and some have used 3D tools to model the system where the models are much more theoretical and quite far from the practical implementation. This article is aimed at closing the gap between the conventional mathematical modeling approaches where the integrated 3D modeling approach with validation on the actual hardware implementation was conducted. To achieve this, both nonlinear and a linearized model in terms of state space model were obtained from the mathematical model of the system for analysis and, thereafter, a 3D virtual prototype of the wheelchair was developed, simulated, and analyzed. This has increased the confidence level for the proposed platform and facilitated the actual hardware implementation of the two-wheeled wheelchair. Results show that the prototype developed and tested has successfully worked within the specific requirements established.
    Matched MeSH terms: Torque
  20. Prakash C, Pramanik A, Basak AK, Dong Y, Debnath S, Shankar S, et al.
    Materials (Basel), 2021 Mar 30;14(7).
    PMID: 33808311 DOI: 10.3390/ma14071699
    In the present research work, an effort has been made to explore the potential of using the adhesive tapes while drilling CFRPs. The input parameters, such as drill bit diameter, point angle, Scotch tape layers, spindle speed, and feed rate have been studied in response to thrust force, torque, circularity, diameter error, surface roughness, and delamination occurring during drilling. It has been found that the increase in point angle increased the delamination, while increase in Scotch tape layers reduced delamination. The surface roughness decreased with the increase in drill diameter and point angle, while it increased with the speed, feed rate, and tape layer. The best low roughness was obtained at 6 mm diameter, 130° point angle, 0.11 mm/rev feed rate, and 2250 rpm speed at three layers of Scotch tape. The circularity error initially increased with drill bit diameter and point angle, but then decreased sharply with further increase in the drill bit diameter. Further, the circularity error has non-linear behavior with the speed, feed rate, and tape layer. Low circularity error has been obtained at 4 mm diameter, 118° point angle, 0.1 mm/rev feed rate, and 2500 RPM speed at three layers of Scotch tape. The low diameter error has been obtained at 6 mm diameter, 130° point angle, 0.12 mm/rev feed rate, and 2500 rpm speed at three layer Scotch tape. From the optical micro-graphs of drilled holes, it has been found that the point angle is one of the most effective process parameters that significantly affects the delamination mechanism, followed by Scotch tape layers as compared to other parameters such as drill bit diameter, spindle speed, and feed rate.
    Matched MeSH terms: Torque
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links