Displaying publications 181 - 200 of 712 in total

Abstract:
Sort:
  1. Atta M, Idris A, Bukhari A, Wahidin S
    Bioresour Technol, 2013 Nov;148:373-8.
    PMID: 24063820 DOI: 10.1016/j.biortech.2013.08.162
    Light quality and the intensity are key factors which render microalgae as a potential source of biodiesel. In this study the effects of various intensities of blue light and its photoperiods on the growth and lipid content of Chlorella vulgaris were investigated by using LED (Light Emitting Diode) in batch culture. C. vulgaris was grown for 13 days at three different light intensities (100, 200 and 300 μmol m(-2)s(-1)). Effect of three different light and dark regimes (12:12, 16:08 and 24:00 h Light:Dark) were investigated for each light intensity at 25°C culture temperature. Maximum lipid content (23.5%) was obtained due to high efficiency and deep penetration of 200 μmol m(-2)s(-1) of blue light (12:12 L:D) with improved specific growth (1.26 d(-1)) within reduced cultivation time of 8 days. White light could produce 20.9% lipid content in 10 days at 16:08 h L:D.
    Matched MeSH terms: Acclimatization/radiation effects; Chlorella vulgaris/radiation effects*; Microalgae/radiation effects*
  2. Maxwell O, Wagiran H, Ibrahim N, Lee SK, Sabri S
    Radiat Prot Dosimetry, 2013 Dec;157(2):271-7.
    PMID: 23754832 DOI: 10.1093/rpd/nct140
    The purpose of this project is to evaluate the suitability of different sites as locations for obtaining underground water for consumption. The analysis of ²³⁸U, ²³²Th and ⁴⁰K from rock samples from each layer of borehole at a depth of ∼50 m at Site A borehole, S3L1-S3L6 in Gosa and 40 m at Site B borehole, S4L1-S4L5 in Lugbe, Abuja, north central Nigeria is presented. The gamma-ray spectrometry was carried out using a high-purity germanium detector coupled to a computer-based high-resolution multichannel analyzer. The activity concentrations at Site A borehole for ²³⁸U have a mean value of 26 ± 3, ranging from 23 ± 2 to 30 ± 3 Bq kg⁻¹, ²³²Th a mean value of 63 ± 5, ranging from 48 ± 4 to 76 ± 6 Bq kg⁻¹ and ⁴⁰K a mean value of 573 ± 72, ranging from 437 ± 56 to 821 ± 60 Bq kg⁻¹. The activity concentrations at Site B borehole for ²³⁸U have a mean value of 20 ± 2, ranging from 16 ± 2 to 23 ± 2 Bq kg⁻¹, ²³²Th a mean value of 46 ± 4, ranging from 43 ± 4 to 49 ± 4 Bq kg⁻¹, ⁴⁰K a mean value of 915 ± 116 and ranging from 817 ± 103 Bq kg⁻¹ to 1011 ± 128 Bq kg⁻¹. It is noted that the higher activity concentrations of ²³²Th and ²³⁸U are found in Site A at Gosa. Site B has lower radioactivity, and it is recommended that both sites are suitable for underground water consumption.
    Matched MeSH terms: Background Radiation*; Radiation Monitoring*
  3. Lah EF, Musa RN, Ho TM
    Asian Pac J Trop Biomed, 2012 Sep;2(9):679-83.
    PMID: 23569994 DOI: 10.1016/S2221-1691(12)60209-3
    To examined the immediate and 24 hours post- irradiation germicidal effects of UV-C lamp on eggs and adults of house dust mites Dermatophagoides pteronyssinus (D. pteronyssinus) and Dermatophagoides farinae (D. farinae).
    Matched MeSH terms: Ovum/radiation effects*; Dermatophagoides farinae/radiation effects*; Dermatophagoides pteronyssinus/radiation effects*
  4. Khalil MI, Sulaiman SA, Alam N, Moniruzzaman M, Bai'e S, Man CN, et al.
    Molecules, 2012 Jan 11;17(1):674-87.
    PMID: 22237682 DOI: 10.3390/molecules17010674
    This study was conducted to evaluate the effects of evaporation, gamma irradiation and temperature on the total polyphenols, flavonoids and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical-scavenging activities of Tualang honey samples (n = 14) following storage over three, six or twelve months. The mean polyphenol concentrations of the six gamma irradiated honey samples at three, six and twelve months, respectively, were 96.13%, 98.01% and 102.03% higher than the corresponding values of the eight non-gamma irradiated samples. Similarly, the mean values for flavonoids at three, six and twelve months were 111.52%, 114.81% and 110.04% higher, respectively, for the gamma irradiated samples. The mean values for DPPH radical-scavenging activities at three, six and twelve months were also 67.09%, 65.26% and 44.65% higher, respectively, for the gamma irradiated samples. These data indicate that all gamma irradiated honey samples had higher antioxidant potential following gamma irradiation, while evaporation and temperature had minor effects on antioxidant potential.
    Matched MeSH terms: Antioxidants/radiation effects; Honey/radiation effects*; Free Radical Scavengers/radiation effects*
  5. Rodzi M, Zhumadilov K, Ohtaki M, Ivannikov A, Bhattacharjee D, Fukumura A, et al.
    Radiat Environ Biophys, 2011 Aug;50(3):451-8.
    PMID: 21404066 DOI: 10.1007/s00411-011-0358-9
    Background radiation dose is used in dosimetry for estimating occupational doses of radiation workers or determining radiation dose of an individual following accidental exposure. In the present study, the absorbed dose and the background radiation level are determined using the electron spin resonance (ESR) method on tooth samples. The effect of using different tooth surfaces and teeth exposed with single medical X-rays on the absorbed dose are also evaluated. A total of 48 molars of position 6-8 were collected from 13 district hospitals in Peninsular Malaysia. Thirty-six teeth had not been exposed to any excessive radiation, and 12 teeth had been directly exposed to a single X-ray dose during medical treatment prior to extraction. There was no significant effect of tooth surfaces and exposure with single X-rays on the measured absorbed dose of an individual. The mean measured absorbed dose of the population is 34 ± 6.2 mGy, with an average tooth enamel age of 39 years. From the slope of a regression line, the estimated annual background dose for Peninsular Malaysia is 0.6 ± 0.3 mGy y(-1). This value is slightly lower than the yearly background dose for Malaysia, and the radiation background dose is established by ESR tooth measurements on samples from India and Russia.
    Matched MeSH terms: Dental Enamel/radiation effects*; Radiation Dosage*
  6. Noriah MA
    Radiat Prot Dosimetry, 2007;125(1-4):101-4.
    PMID: 17145724
    This paper discusses the advantage of certification process in the quality assurance of individual dose monitoring in Malaysia. The demand by customers and the regulatory authority for a higher degree of quality service requires a switch in emphasis from a technically focused quality assurance program to a comprehensive quality management for service provision. Achieving the ISO 9001:2000 certification by an accredited third party demonstrates acceptable recognition and documents the fact that the methods used are capable of generating results that satisfy the performance criteria of the certification program. It also offers a proof of the commitment to quality and, as a benchmark, allows measurement of the progress for continual improvement of service performance.
    Matched MeSH terms: Radiation Monitoring/standards*; Radiation Protection/standards*
  7. Ramanaidu S, Sta Maria R, Ng Kh, George J, Kumar G
    Biomed Imaging Interv J, 2006 Jul;2(3):e35.
    PMID: 21614244 MyJurnal DOI: 10.2349/biij.2.3.e35
    A study of radiation dose and image quality following changes to the tube potential (kVp) in paediatric chest radiography.
    Matched MeSH terms: Radiation Dosage
  8. Mohanan AA, Islam MS, Ali SH, Parthiban R, Ramakrishnan N
    Sensors (Basel), 2013;13(2):2164-75.
    PMID: 23389346 DOI: 10.3390/s130202164
    In this work mass loading sensitivity of a Sezawa wave mode based surface acoustic wave (SAW) device is investigated through finite element method (FEM) simulation and the prospects of these devices to function as highly sensitive SAW sensors is reported. A ZnO/Si layered SAW resonator is considered for the simulation study. Initially the occurrence of Sezawa wave mode and displacement amplitude of the Rayleigh and Sezawa wave mode is studied for lower ZnO film thickness. Further, a thin film made of an arbitrary material is coated over the ZnO surface and the resonance frequency shift caused by mass loading of the film is estimated. It was observed that Sezawa wave mode shows significant sensitivity to change in mass loading and has higher sensitivity (eight times higher) than Rayleigh wave mode for the same device configuration. Further, the mass loading sensitivity was observed to be greater for a low ZnO film thickness to wavelength ratio. Accordingly, highly sensitive SAW sensors can be developed by coating a sensing medium over a layered SAW device and operating at Sezawa mode resonance frequency. The sensitivity can be increased by tuning the ZnO film thickness to wavelength ratio.
    Matched MeSH terms: Radiation
  9. Wee LK, Chong TK, Quee DK
    Photodermatol Photoimmunol Photomed, 1997 Oct-Dec;13(5-6):169-72.
    PMID: 9542751
    Ninety normal individuals were included in this study on skin types, skin colours and cutaneous responses to ultraviolet radiation. Skin types were recorded using Fitzpatrick's classification, skin colours were measured using the Minolta Chromameter CR-300, and cutaneous responses to UV radiation were measured in terms of minimal erythema dose (MED) to UVA, UVB and the immediate pigment darkening dose to UVA (IPDDA). Skin colour measurements were taken from the right cheek to represent facultative skin colours, and from the buttock to represent constitutive skin colours. The colours measured were expressed by the L x a x b colour space. Skin types and some colour parameters (L and b from covered parts of body) correlated fairly well with the minimal erythema doses (MED) to UVA and UVB. Skin colour measurements are more objective than skin type assessment and could be better markers of photosensitivity. However, there is still considerable overlap in MEDs for persons with different skin colours, and further studies of these parameters are warranted. Our MEDs are higher than other reports on similar skin types and skin colours. This could be due to differences in methodology, genetic make-up or acclimatization from chronic sun exposure. This illustrates the importance of local controls for each institution dealing with photosensitive disorders.
    Matched MeSH terms: Radiation Dosage; Skin/radiation effects*; Skin Pigmentation/radiation effects*
  10. Khan N
    Appl Opt, 2004 Jan 20;43(3):678-81.
    PMID: 14765930
    The theoretical basis for simultaneous oscillation of 2N - 3 laser lines is due to interference of N (for all even N > or = 2) pump beams in a distributed-feedback dye laser is described. Multiple gratings are produced in a dye solution by interference patterns of N/2 pairs of a frequency-doubled Nd:YAG laser. N/2 pairs of mutually time-delayed pulses induce multiple gratings of different periodicities, of which 2N - 3 gratings support oscillation of 2N - 3 lines and the remaining gratings, because of their larger periods, cannot support Bragg scattering. The maximum number of laser lines depends on the mutual delay between adjacent pairs of beams, coherence, states of polarization, pulse lengths, and of course the number of pulses. For three pairs of excitation beams derived from the same source through wave-front or amplitude phase division techniques, the output lasing lines varied from a minimum of three to a maximum of nine. This research was carried out by pumping of a dye solution with two, four, and six pulses, but the principle may be extended to multiple output lines, depending on the number of pump pulses and on the gain of the dye solution.
    Matched MeSH terms: Radiation
  11. Ansarudin F, Abd Rahman T, Yamada Y, Rahman NHA, Kamardin K
    Sensors (Basel), 2020 Oct 16;20(20).
    PMID: 33081110 DOI: 10.3390/s20205849
    In the 5G mobile system, new features such as millimetre wave operation, small cell size and multi beam are requested at base stations. At millimetre wave, the base station antennas become very small in size, which is about 30 cm; thus, dielectric lens antennas that have excellent multi beam radiation pattern performance are suitable candidates. For base station application, the lens antennas with small thickness and small curvature are requested for light weight and ease of installation. In this paper, a new lens shaping method for thin and small lens curvature is proposed. In order to develop the thin lens antenna, comparisons of antenna structures with conventional aperture distribution lens and Abbe's sine lens are made. Moreover, multi beam radiation pattern of three types of lenses are compared. As a result, the thin and small curvature of the proposed lens and an excellent multi beam radiation pattern are ensured.
    Matched MeSH terms: Radiation
  12. Samsuzzaman M, Islam MT
    Sensors (Basel), 2018 Dec 04;18(12).
    PMID: 30518080 DOI: 10.3390/s18124261
    A simple, compact sickle-shaped printed antenna with a slotted ground plane is designed and developed for broadband circularly polarized (CP) radiation. The sickle-shaped radiator with a tapered feed line and circular slotted square ground plane are utilized to realize the wideband CP radiation feature. With optimized dimensions of 0.29λ × 0.29λ × 0.012λ at 2.22 GHz frequency for the realized antenna parameters, the measured results display that the antenna has a 10 dB impedance bandwidth of 7.70 GHz (126.85%; 2.22⁻9.92 GHz) and a 3 dB axial ratio (AR) bandwidth of 2.64 GHz (73.33%; 2.28⁻4.92 GHz). The measurement agrees well with simulation, which proves an excellent circularly polarized property. For verification, the mechanism of band improvement and circular polarization are presented, and the parametric study is carried out. Since, the proposed antenna is a simple design structure with broad impedance and AR bandwidth, which is a desirable feature as a candidate for various wireless communication systems. Because of the easy printed structure and scaling the dimension with broadband CP characteristics, the realized antenna does incorporate in a number of CP wireless communication applications.
    Matched MeSH terms: Electromagnetic Radiation
  13. Sathik MJ, Almakhles DJ, Sandeep N, Siddique MD
    Sci Rep, 2021 Mar 03;11(1):5067.
    PMID: 33658562 DOI: 10.1038/s41598-021-84531-z
    Multilevel inverters play an important role in extracting the power from renewable energy resources and delivering the output voltage with high quality to the load. This paper proposes a new single-stage switched capacitor nine-level inverter, which comprises an improved T-type inverter, auxiliary switch, and switched cell unit. The proposed topology effectively reduces the DC-link capacitor voltage and exhibits superior performance over recently switched-capacitor inverter topologies in terms of the number of power components and blocking voltage of the switches. A level-shifted multilevel pulse width modulation scheme with a modified triangular carrier wave is implemented to produce a high-quality stepped output voltage waveform with low switching frequency. The proposed nine-level inverter's effectiveness, driven by the recommended modulation technique, is experimentally verified under varying load conditions. The power loss and efficiency for the proposed nine-level inverter are thoroughly discussed with different loads.
    Matched MeSH terms: Radiation
  14. Moey, Soo-Foon, Nur Farah Hani Muhd Jaafar, Nursyahirah Saidin
    MyJurnal
    Introduction: Various medium and high tube potentials were utilized to conduct chest x-rays. There
    are advantages and disadvantages with regards to image quality and radiation dose when using
    medium and high kilovoltage (kVp) technique. However, radiographers have misconstrued
    understanding pertaining to the choice of tube potential as well as grid usage when performing chest radiography. Methods: The experimental study was conducted using the PBU-50 phantom by exposing it with medium kVp utilizing grid and non-grid as well as high kVp with grid. All images obtained were evaluated using the modified evaluation criteria for PA chest established by the Commission of European Communities, 1996 whilst the dose area product (DAP) was determined using the Dose Area Product (DAP) meter. The value obtained from the DAP meter was converted to entrance surface dose (ESD) usingCALDOSE_X5.0 software and mathematical formula. Results: The Wilcoxon Signed-Rank Test indicated a significant difference in ESD when using medium and high kVp; Z= -2.666, p
    Matched MeSH terms: Radiation Dosage
  15. Abu Bakar H, Abd Rahim R, Soh PJ, Akkaraekthalin P
    Sensors (Basel), 2021 Jan 26;21(3).
    PMID: 33530534 DOI: 10.3390/s21030827
    Advances in reconfigurable liquid-based reconfigurable antennas are enabling new possibilities to fulfil the requirements of more advanced wireless communication systems. In this review, a comparative analysis of various state-of-the-art concepts and techniques for designing reconfigurable antennas using liquid is presented. First, the electrical properties of different liquids at room temperature commonly used in reconfigurable antennas are identified. This is followed by a discussion of various liquid actuation techniques in enabling high frequency reconfigurability. Next, the liquid-based reconfigurable antennas in literature used to achieve the different types of reconfiguration will be critically reviewed. These include frequency-, polarization-, radiation pattern-, and compound reconfigurability. The current concepts of liquid-based reconfigurable antennas can be classified broadly into three basic approaches: altering the physical (and electrical) dimensions of antennas using liquid; applying liquid-based sections as reactive loads; implementation of liquids as dielectric resonators. Each concept and their design approaches will be examined, outlining their benefits, limitations, and possible future improvements.
    Matched MeSH terms: Radiation
  16. Ahamed E, Faruque MRI, Alam MJ, Mansor MFB, Islam MT
    Sci Rep, 2020 Feb 24;10(1):3289.
    PMID: 32094436 DOI: 10.1038/s41598-020-60170-8
    A new approach to controlling the flow of a plasmatic electron packet at the interface between metallic and dielectric layers is described. The proposed metamaterial structure operates in the optical frequency range and can be used as a digital processing filter. It exhibits two double negative resonances and one special passband region, while the existence of a metal-dielectric nano-tunnel enhances electromagnetic wave-metal interactions. The structural arrangement of this metamaterial coupled with the tunnel layer can effectively control the electric field and allows digital encoding of electron packets.
    Matched MeSH terms: Electromagnetic Radiation
  17. Mahendra CK, Tan LTH, Pusparajah P, Htar TT, Chuah LH, Lee VS, et al.
    Oxid Med Cell Longev, 2020;2020:1904178.
    PMID: 32855763 DOI: 10.1155/2020/1904178
    Retinal pigment epithelial (RPE) cells are an essential part of the human eye because they not only mediate and control the transfer of fluids and solutes but also protect the retina against photooxidative damage and renew photoreceptor cells through phagocytosis. However, their function necessitates cumulative exposure to the sun resulting in UV damage, which may lead to the development of age-related macular degeneration (AMD). Several studies have shown that UVB induces direct DNA damage and oxidative stress in RPE cells by increasing ROS and dysregulating endogenous antioxidants. Activation of different signaling pathways connected to inflammation, cell cycle arrest, and intrinsic apoptosis was reported as well. Besides that, essential functions like phagocytosis, osmoregulation, and water permeability of RPE cells were also affected. Although the melanin within RPE cells can act as a photoprotectant, this photoprotection decreases with age. Nevertheless, the changes in lens epithelium-derived growth factor (LEDGF) and autophagic activity or application of bioactive compounds from natural products can reverse the detrimental effect of UVB. Additionally, in vivo studies on the whole retina demonstrated that UVB irradiation induces gene and protein level dysregulation, indicating cellular stress and aberrations in the chromosome level. Morphological changes like retinal depigmentation and drusen formation were noted as well which is similar to the etiology of AMD, suggesting the connection of UVB damage with AMD. Therefore, future studies, which include mechanism studies via in vitro or in vivo and other potential bioactive compounds, should be pursued for a better understanding of the involvement of UVB in AMD.
    Matched MeSH terms: Epithelial Cells/radiation effects*; Apoptosis/radiation effects; Retinal Pigment Epithelium/radiation effects*
  18. Chen CD, Azahari AH, Saadiyah I, Lee HL
    Trop Biomed, 2007 Dec;24(2):89-91.
    PMID: 18209714 MyJurnal
    Photon (light) technology has already been widely used in make-up, medical treatment etc, but repelling mosquitoes by photon technology is an innovation. The objective of this study was to determine the efficacy of a mosquito repelling lamp, E Da under indoor conditions. E Da lamp is a lamp coated with yellow luminous pigment on the inner part of the glass bulb of the lamp which is used to screen out the UV radiation, and when it is turned on, the yellow illuminating wavelength will drive the mosquitoes away. The tests were conducted inside 2 cabins measuring 8' X 8' X 20'. The mosquito population was estimated by using the Bare Leg Catch (BLC) techniques. For treated test, E Da lamp was placed indoor 2 - 3 meters away from a human bait. Another cabin without the lamp was used as untreated control. BLC was conducted in both sites simultaneously. The mosquitoes collected in this study were solely those of Culex quinquefasciatus and Aedes albopictus. There was an 91.34% reduction of Cx. quinquefasciatus population in the treated test compared with the untreated cabin during the 4 hours catches (p < 0.05). E Da mosquito repelling lamp used in this study exerted repellency effect against the mosquitoes especially Cx. quinquefasciatus.
    Matched MeSH terms: Aedes/radiation effects*; Culex/radiation effects*; Insect Vectors/radiation effects
  19. M. Fahmi M. Yusof, Nornashriah A. Rashid, Reduan Abdullah
    MyJurnal
    The glow curve in TLD-100 was compared by applying long preheat time, short preheat time
    techniques and without preheat technique before the TLD readout. Fading effect of the TLD signal
    upon certain storage time with long preheat time (100°C, 10 minutes using the oven) and short
    preheat time techniques (100°C, 10 seconds using the reader) were also studied. 15 TLD-100 chips
    were used with 3 of the TLD chips were used for measuring background radiation. 12 TLD chips
    were annealed, irradiated, preheated long and short preheat time techniques) and analyzed. The TL
    signals output from TLD chips of without preheated were used as the control. Two sets of data were
    taken using TLD chips irradiated with 6 MV and 10 MV photon beams. TL signal output was
    recorded the highest for short preheat time, followed by long preheat time and no preheating. The
    TL signal loss upon certain storage time was also reduced when short preheat time technique was
    applied. By applying long preheat time technique the low temperature peak in the glow curve was
    completely removed for both energies. Whereas, TLD chips exposed to 6 MV and with short preheat
    time technique the low temperature peak did not disappear completely but decreased in intensity as
    compared to the control data by 19.80%, 37.69%, 48.19% and 100% at 24, 48, 72 and 96 hours
    after exposure prior to readout, respectively. Meanwhile, for 10 MV photon beam with short
    preheat time, the small peak intensity was reduced by 19.58% for readout at 24 hours after
    irradiation and 100% for 48,72 and 96 hours delayed time prior to readout. It was observed that
    the TLD-100 was highly dependent on preheat heating time before readout. Short preheat time
    technique was able to reduce post irradiation fading of TLD-100 dosimeters
    Matched MeSH terms: Background Radiation
  20. Islam SS, Faruque MR, Islam MT
    Sci Rep, 2016 09 16;6:33624.
    PMID: 27634456 DOI: 10.1038/srep33624
    A new, metamaterial-based electromagnetic cloaking operation is proposed in this study. The metamaterial exhibits a sharp transmittance in the C-band of the microwave spectrum with negative effective property of permittivity at that frequency. Two metal arms were placed on an FR-4 substrate to construct a double-split-square shape structure. The size of the resonator was maintained to achieve the effective medium property of the metamaterial. Full wave numerical simulation was performed to extract the reflection and transmission coefficients for the unit cell. Later on, a single layer square-shaped cloak was designed using the proposed metamaterial unit cell. The cloak hides a metal cylinder electromagnetically, where the material exhibits epsilon-near-zero (ENZ) property. Cloaking operation was demonstrated adopting the scattering-reduction technique. The measured result was provided to validate the characteristics of the metamaterial and the cloak. Some object size- and shape-based analyses were performed with the cloak, and a common cloaking region was revealed over more than 900 MHz in the C-band for the different objects.
    Matched MeSH terms: Radiation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links