OBJECTIVE: To examine the feasibility of TV-NOSE in live donor nephrectomy.
MATERIALS AND METHODS: 53 patients received LDN surgery at our hospital from September 2017 to December 2021. Retrospectively, living donor nephrectomy with TV-NOSE was compared to three different surgical procedures with standard specimen extraction.
RESULTS: 53 donor patients were included: 15 open (OLDN), 12 retroperitoneoscopic living donor nephrectomy (RPLDN), 10 transperitoneal living donor nephrectomy (TPLDN), and 16 standard laparoscopic living donor nephrectomy with transvaginal extraction (SLLDN TV-NOSE). SLLDN TVNOSE's longer operating time (p<0.0041) did not affect graft function. SLLDN TV-NOSE and RPLDN had shorter lengths of stay and better VAS trends than open LDN and TPLDN (p<0.05). SLLDN TV-NOSE donors reported acceptable surgical outcomes and unchanged sexual function. All patients had similar discharge creatinine levels, with 1-year transplant survival of 98% and just 1 graft loss in the TPLDN group.
CONCLUSION: SLLDN TV-NOSE is equivalent to RPLDN and better than open LDN and TPLDN in terms of duration of stay, VAS score, surgical outcomes, and sexual function. TVNOSE is a safe surgical procedure with an acceptable donor complication. TV-NOSE may be safely conducted in both developed and developing countries with proper patient selection.
MATERIALS AND METHODS: A retrospective repeated crosssectional study was conducted by recruiting patients with cochlear implants presenting to the Dr. Cipto Mangunkusumo National General Hospital, Jakarta, Indonesia between 2017 and 2021. Basal (b1, b2) and apical (a1, a2) electrodes, representing the outermost and innermost parts of the cochlear implant electrodes, were measured at switch on and at 1 year post-implantation.
RESULTS: A total of 123 patients, with a total of 123 cochlear implant samples, were included in the analysis. We found a substantial change in electrical impedance between switch on and follow-up periods, where the impedance levels of basal electrodes decreased (b1: mean difference (MD) -1.13 [95% confidence interval (CI): -1.71, -0.54], p<0.001; b2: MD -0.60 [95%CI: -1.17, -0.03], p=0.041) and those of apical electrodes increased (a1: MD 0.48 [95%CI: -0.28, 0.99], p=0.064; a2: MD 0.67 [95%CI: 0.12, 1.22], p=0.017). We also found that the choice of surgical approaches for implant insertion may affect the electrode impedance. Cochleostomy approach resulted in a higher impedance than round window in basal (b1) and apical (a2) electrodes both at switch on and follow-up (b1 at switch on and at follow-up: p=0.019 and p=0.004; a2 at follow-up: p=0.012). Extended round window approach also resulted in a higher impedance than round window in basal (b1) and apical (a2) electrodes at follow-up (p=0.013 and p=0.003, respectively).
CONCLUSION: Electrical impedance of cochlear implant electrodes may change over time, highlighting the importance of regular impedance assessments for cochlear implant users to ensure optimal device function. The round window approach resulted in better initial and long-term impedance levels compared to cochleostomy, and better long-term impedance levels than extended round window. Extended round window approach also gives better impedance level than cochleostomy. Further research should investigate the potential interplay between surgical approach and other factors that may impact impedance levels to confirm our findings.