RESULTS: Two predictive models were constructed. Both models revealed that being female (OR=1.578, 95 % CI: 1.191, 2.092, p=0.001), having Malay ethnicity (OR=1.733, 95 % CI: 1.236, 2.429, p=0.001) and having a disease significantly increased the risk of suicide (OR=1.895, 95 % CI: 1.221, 2.942, p=0.004). In particular, Model 2, which showed a better fit, found that occasional religious practice (OR=1.610, 95 % CI: 1.126, 2.303, p=0.009), poor parental relationships (OR=1.739, 95 % CI: 1.035, 2.922, p=0.037) and higher addiction (OR=1.015, 95 % CI: 1.008, 1.022, p=0.001), depression (OR=1.919, 95 % CI: 1.241, 2.968, p=0.003), and stress (OR=2.707, 95 % CI: 1.689, 4.340, p=0.001) scores were significantly associated with an increased risk of suicide.
CONCLUSIONS: This study sheds light on multiple factors that contribute to the risk of suicide among adolescents in Sarawak. These findings underscore the importance of holistic prevention strategies, including psychological and social dimensions, to mitigate the risk of suicide in this population. Further research is warranted to understand the complex interplay of these factors and guide the development of targeted interventions.
DESIGN: A cross-sectional, non-interventional study.
METHODS: The IOP measurements by handheld Icare rebound tonometer (Finland) were first performed by a primary care physician. Then the IOP was measured using Perkins Mk3 applanation tonometer (Haag-Streit, UK) by an ophthalmologist who was masked to previous readings from the Icare rebound tonometer. The mean IOP measured by each tonometer was compared. Pearson correlation coefficient was used to explore the correlation between the IOP measurements of the 2 instruments. The level of agreement between them was assessed using the Bland and Altman method.
RESULTS: A total of 420 left eyes were examined. The mean age of subjects was 38.6 ± 18.2 years. Approximately 67% of subjects were female. The mean IOP was 16.3 ± 4.0 mm Hg using Icare and 13.4 ± 2.3 mm Hg using PAT. Pearson correlation coefficient showed a moderate positive correlation between the 2 methods (r = +0.524, P < 0.001). Linear regression analysis revealed a slope of 0.28 with R² of 0.255. The mean difference between the 2 methods was 2.90 ± 3.5 mm Hg and the sample t-test revealed a statistically significant mean difference from 0 (P < 0.001). The 95% limits of agreement between the 2 methods were between -9.73 and 3.93 mm Hg.
CONCLUSIONS: The handheld Icare rebound tonometer is a reasonably acceptable screening tool in community practices. However, Icare overestimated IOP with a mean of 2.90 mm Hg higher than the PAT. Thus, using Goldmann applanation tonometer as a confirmatory measurement tool of IOP is suggested.