A capillary electrophoretic method for the separation of the enantiomers of both ofloxacin and ornidazole is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixtures was achieved in less than 16 min with resolution factors Rs=5.45 and 6.28 for ofloxacin and ornidazole enantiomers, respectively. Separation was conducted using a bare fused-silica capillary and a background electrolyte (BGE) of 50 mM H(3)PO(4)-1 M tris solution; pH 1.85; containing 30 mg mL(-1) of sulfated-beta-cyclodextrin (S-beta-CD). The separation was carried out in reversed polarity mode at 25 degrees C, 18 kV, detection wavelength at 230 nm and using hydrodynamic injection for 15 s. Acceptable validation criteria for selectivity, linearity, precision, and accuracy were studied. The limits of detection (LOD) and limits of quantitation (LOQ) of the enantiomers (ofloxacin enantiomer 1 (OF-E1), ofloxacin enantiomer 2 (OF-E2), ornidazole enantiomer 1 (OR-E1) and ornidazole enantiomer 2 (OR-E2)) were (0.52, 0.46, 0.54, 0.89) and (1.59, 1.40, 3.07, 2.70) microg mL(-1), respectively. The proposed method was successfully applied to the assay of enantiomers of both ofloxacin and ornidazole in pharmaceutical formulations. The computational calculations for the enantiomeric inclusion complexes rationalized the reasons for the different migration times between the ofloxacin and ornidazole enantiomers.
A simple, rapid and validated capillary electrophoretic method has been developed for the separation and determination of ofloxacin and ornidazole in pharmaceutical formulations with detection at 230 nm. Optimal conditions for the quantitative separations were investigated. Analysis times shorter than 4 min were obtained using a background electrolyte solution consisting of 25 mmol/L phosphoric acid adjusted with 1 M Tris buffer to pH 8.5, with hydrodynamic injection of 5 s and 20 kV separation voltage. The validation criteria for accuracy, precision, linearity and limits of detection and quantitation were examined and discussed. An excellent linearity was obtained in concentration range 25-250 microg/mL. The detection limits for ofloxacin and ornidazole were 1.03 +/- 0.11 and 1.80 +/- 0.06 microg/mL, respectively. The proposed method has been applied for the analysis of ofloxacin and ornidazole both individually and in a combined dosage tablet formulation. The proposed validated method showed recoveries between 96.16 and 105.23% of the nominal contents.
Rapid and direct online preconcentration followed by CE with capacitively coupled contactless conductivity detection (CE-C(4)D) is evaluated as a new approach for the determination of glyphosate, glufosinate (GLUF), and aminophosphonic acid (AMPA) in drinking water. Two online preconcentration techniques, namely large volume sample stacking without polarity switching and field-enhanced sample injection, coupled with CE-C(4)D were successfully developed and optimized. Under optimized conditions, LODs in the range of 0.01-0.1 microM (1.7-11.1 microg/L) and sensitivity enhancements of 48- to 53-fold were achieved with the large volume sample stacking-CE-C(4)D method. By performing the field-enhanced sample injection-CE-C(4)D procedure, excellent LODs down to 0.0005-0.02 microM (0.1-2.2 microg/L) as well as sensitivity enhancements of up to 245- to 1002-fold were obtained. Both techniques showed satisfactory reproducibility with RSDs of peak height of better than 10%. The newly established approaches were successfully applied to the analysis of glyphosate, glufosinate, and aminophosphonic acid in spiked tap drinking water.
Capillary zone electrophoresis methods for the simultaneous determination of the beta-blocker drugs, atenolol, chlorthalidone and amiloride, in pharmaceutical formulations have been developed. The influences of several factors (buffer pH, concentration, applied voltage, capillary temperature and injection time) were studied. Using phenobarbital as internal standard, the analytes were all separated in less than 4 min. The separation was carried out in normal polarity mode at 25 degrees C, 25 kV and using hydrodynamic injection (10 s). The separation was effected in an uncoated fused-silica capillary (75 mum i.d. x 52 cm) and a background electrolyte of 25 mm H(3)PO(4) adjusted with 1 m NaOH solution (pH 9.0) and detection at 198 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 1-250 microg/mL for atenolol and chlorthalidone and from 2.5-250 microg/mL for amiloride. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol, chlorthalidone and amiloride in various pharmaceutical tablets formulations.
A capillary electrophoretic method for the separation of the aminoglutethimide (AGT) enantiomers using methylated-beta-cyclodextrin (M-beta-CD) as chiral selector is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixture was achieved in less than 9 min with resolution factor Rs=2.1, using a fused-silica capillary and a background electrolyte (BGE) of tris-phosphate buffer solution (50 mmol L(-1), pH 3.0) containing 30 mgm L(-1) of M-beta-CD. The separation was carried out in normal polarity mode at 25 degrees C, 16 kV and using hydrostatic injection. Acceptable validation criteria for selectivity, linearity, precision, and accuracy/recovery were included. The proposed method was successfully applied to the assay of AGT enantiomers in pharmaceutical formulations. The computational calculations for the inclusion complexes of the R- and S-AGT-M-beta-CD rationalized the reasons for the different migration times between the AGT enantiomers.
A fast and simple capillary zone electrophoresis method was developed and validated for the determination of lidocaine in skin using tape samples. Separation was performed in a 350 mm (265 mm to window) x 50 microm i.d. fused silica capillary using a background electrolyte of phosphoric acid-Tris pH 2.5. The extraction of lidocaine from tape samples was achieved using methanol, which was diluted to 50% with water before injection. Procaine was the internal standard. The migration times for procaine and lidocaine were 2.9 and 3.2 min, respectively. The limit of quantification for lidocaine was 50 microg, with signal to noise ratio greater than 10. The calibration curve was linear from 50 to 1000 microg with r(2) greater than 0.99. The CV for both within- and between-assay imprecision and the percentage of inaccuracy for the quality control samples including lower and upper limits of quantitation were 97%. The accuracy and selectivity of this method allowed the measurement of lidocaine in tape samples obtained from a skin tape stripping study of local anesthetics in healthy subjects.
Online preconcentration using electrokinetic supercharging (EKS) was proposed to enhance the sensitivity of separation for endocrine disrupting chemical (methylparaben (MP)) and phenolic pollutants (2-nitrophenol (NP) and 4-chlorophenol (CP)) in water sample. Important EKS and separation conditions such as the concentration of BGE; the choice of terminating electrolyte (TE); and the injection time of leading electrolyte (LE), sample, and TE were optimized. The optimum EKS-CE conditions were as follows: BGE comprising of 12 mM sodium tetraborate pH 10.1, 100 mM sodium chloride as LE hydrodynamically injected at 50 mbar for 30 s, electrokinetic injection (EKI) of sample at -3 kV for 200 s, and 100 mM CHES as TE hydrodynamically injected at 50 mbar for 40 s. The separation was conducted at negative polarity mode and UV detection at 214 nm. Under these conditions, the sensitivity of analytes was enhanced from 100- to 737-fold as compared to normal CZE with hydrodynamic injection, giving LOD of 4.89, 5.29, and 53 μg/L for MP, NP and CP, respectively. The LODs were adequate for the analysis of NP and CP in environmental water sample having concentration at or lower than their maximum admissible concentration limit (240 and 2000 μg/L for NP and CP). The LOD of MP can be suitable for the analysis of MP exists at mid-microgram per liter level, even though the LOD was slightly higher than the concentration usually found in water samples (from ng/L to 1 μg/L). The method repeatabilities (%RSD) were in the range of 1.07-2.39% (migration time) and 8.28-14.0% (peak area).
One of the most cited limitations of capillary (and microchip) electrophoresis is the poor sensitivity. This review continues to update this series of biennial reviews, first published in Electrophoresis in 2007, on developments in the field of on-line/in-line concentration methods in capillaries and microchips, covering the period July 2014-June 2016. It includes developments in the field of stacking, covering all methods from field amplified sample stacking and large volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.
A new approach based on the integration of the free liquid membrane (FLM) into electrokinetic supercharging (EKS) was demonstrated to be a new powerful tool used in order to enhance online preconcentration efficiency in capillary electrophoresis (CE). A small plug of water immiscible organic solvent was used as a membrane interface during the electrokinetic sample injection step in EKS in order to significantly enhance the analyte stacking efficiency. The new online preconcentration strategy was evaluated for the determination of paraquat and diquat present in the environmental water samples. The optimised FLM-EKS conditions employed were as follows: hydrodynamic injection (HI) of 20mM potassium chloride as leading electrolyte at 50mbar for 75s (3% of the total capillary volume) followed by the HI of tris(2-ethylhexyl) phosphate (TEHP) as FLM at a 1mm length (0.1% of the capillary volume). The sample was injected at 10kV for 360s, followed by the HI of 20mM cetyl trimethylammonium bromide (CTAB) as terminating electrolyte at 50mbar for 50s (2% of the total capillary volume). The separation was performed in 12mM ammonium acetate and 30mM NaCl containing 20% MeOH at +25kV with UV detection at 205nm. Under optimised conditions, the sensitivity was enhanced between 1500- and 1866-fold when compared with the typical HI at 50mbar for 50s. The detection limit of the method for paraquat and diquat was 0.15-0.20ng/mL, with RSDs below 5.5%. Relative recoveries in spiked river water were in the range of 95.4-97.5%. A comparison was also made between the proposed approach with sole preconcentration of the field-enhanced sample injection (FASI) and EKS in the absence of the FLM.
The SNPforID consortium identified a panel of 52 SNPs for forensic analysis that has been used by several laboratories worldwide. The original analysis of the 52 SNPs was based on a single multiplex reaction followed by two single-base-extension (SBE) reactions each of which was analyzed using capillary electrophoresis. The SBE assays were designed for high throughput genetic analyzers and were difficult to use on the single capillary ABI PRISM 310 Genetic Analyzer and the latest generation 3500 Genetic Analyzer, as sensitivity on the 310 was low and separation of products on the 3500 with POP-7™ was poor. We have modified the original assay and split it into four multiplex reactions, each followed by an SBE assay. These multiplex assays were analyzed using polymer POP-4™ on ABI 310 PRISM® and polymers POP-4™, POP-6™ and POP-7™ on the 3500 Genetic Analyzer. The assays were sensitive and reproducible with input DNA as low as 60 pg using both the ABI 310 and 3500. In addition, we found that POP-6™ was most effective with the 3500, based on the parameters that we assessed, achieving better separation of the small SBE products; this conflicted with the recommended use of POP-7™ by the instrument manufacturer. To support the use of the SNP panel in casework in Malaysia we have created an allele frequency database from 325 individuals, representing the major population groups within Malaysia. Population and forensic parameters were estimated for all populations and its efficacy evaluated using 51 forensic samples from challenging casework.
A dynamic supported liquid membrane tip extraction (SLMTE) procedure for the effective extraction and preconcentration of glyphosate (GLYP) and its metabolite aminomethylphosphonic acid (AMPA) in water has been investigated. The SLMTE procedure was performed in a semi-automated dynamic mode and demonstrated a greater performance against a static extraction. Several important extraction parameters such as donor phase pH, cationic carrier concentration, type of membrane solvent, type of acceptor stripping phase, agitation and extraction time were comprehensively optimized. A solution of Aliquat-336, a cationic carrier, in dihexyl ether was selected as the supported liquid incorporated into the membrane phase. Quantification of GLYP and AMPA was carried out using capillary electrophoresis with contactless conductivity detection. An electrolyte solution consisting of 12 mM histidine (His), 8 mM 2-(N-morpholino)ethanesulfonic acid (MES), 75 microM cetyltrimethylammonium bromide (CTAB), 3% methanol, pH 6.3, was used as running buffer. Under the optimum extraction conditions, the method showed good linearity in the range of 0.01-200 microg/L (GLYP) and 0.1-400 microg/L (AMPA), acceptable reproducibility (RSD 5-7%, n=5), low limits of detection of 0.005 microg/L for GLYP and 0.06 microg/L for AMPA, and satisfactory relative recoveries (90-94%). Due to the low cost, the SLMTE device was disposed after each run which additionally eliminated the possibility of carry-over between runs. The validated method was tested for the analysis of both analytes in spiked tap water and river water with good success.
Insertion/deletion polymorphisms (INDELs) are a relatively new class of a DNA marker to be used in forensic casework; used most commonly as a supplementary method to STR-based typing. INDELs, like SNPs, are particularly useful for the analysis of highly degraded DNA as the amplicon sizes are typically below 160 bp; they can also be valuable as an additional tool to help resolve kinship cases, with the advantage over STRs that they do not have high mutation rates. INDELs have an advantage over SNPs in that they are length polymorphisms and so can be analyzed by simply measuring the length of the allele(s). The Qiagen Investigator(®) DIPplex Kit is currently only one of two commercially available kits for the amplification of INDEL polymorphisms; it amplifies 30 biallelic INDEL loci and the amelogenin locus. The primers used are fluorescence labeled with 6-FAM, BTG, BTY, and BTR. This technique is robust, relatively simple, and the results are analyzed using the same capillary electrophoresis equipment and software as used for STR typing.
Cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) method was developed for simultaneous enantioseparation of three imidazole drugs namely tioconazole, isoconazole and fenticonazole. Three easily available and inexpensive cyclodextrins namely 2-hydroxypropyl-β-cyclodextrin (HP-β-CD), 2-hydroxypropyl-γ-cyclodextrin (HP-γ-CD) and heptakis(2,6-di-O-methyl)-β-cyclodextrin (DM-β-CD) were evaluated to discriminate the six stereoisomers of the drugs. However, none of the three CDs gave a complete enantioseparation of the drugs. Effective enantioseparation of tioconazole, isoconazole and fenticonazole was achieved using a combination of 35 mM HP-γ-CD and 10 mM DM-β-CD as chiral selectors. The best separation using both HP-γ-CD and DM-β-CD (35 mM:10 mM) as chiral selectors were accomplished in background electrolyte (BGE) containing 35 mM phosphate buffer (pH 7.0), 50 mM sodium dodecyl sulfate (SDS) and 15% (v/v) acetonitrile at 27 kV and 30 °C with all peaks resolved in less than 15 min with resolutions, Rs 1.90-27.22 and peak efficiencies, N > 180 000. The developed method was linear over the concentration range of 25-200 mg l(-1) (r(2) > 0.998) and the detection limits (S/N = 3) of the three imidazole drugs were found to be 2.7-7.7 mg l(-1). The CD-MEKC method was successfully applied to the determination of the three imidazole drugs in spiked human urine sample and commercial cream formulation of tioconazole and isoconazole with good recovery (93.6-106.2%) and good RSDs ranging from 2.30-6.8%.
For the rapid simultaneous determination of monosodium glutamate (MSG), benzoic acid (BA), and sorbic acid (SA) in canned food and other processed food samples, we developed a method that combines in-capillary derivatization with separation by capillary electrophoresis. This method employs the rapid derivatization of MSG with o-phthalaldehyde (OPA) in the presence of 3-mercaptopropionic acid (3-MPA) and enables the detection of the resulting OPA-MSG derivative and of non-derivatized BA and SA at 230nm. The composition of the background electrolyte and the parameters of derivatization and separation are as follows: 25mM borax containing 5mM OPA and 6mM 3-MPA, separation voltage 25mV, injection at 30mbar for 20s, and column temperature 25°C. Because of the high reaction rate and suitably adapted effective electrophoretic mobilities, band broadening due to the derivatization reaction at the start of the separation process is kept to a minimum. The optimized method is validated with respect to LOD, LOQ, linearity, recovery, and precision. This method can be applied to real samples such as soy, fish, oyster and sweet and sour chili sauces after application of appropriate clean-up steps. Mechanisms of zone broadening and zone focusing are discussed showing the validity of the employed theoretical approach regarding the dependence of the peak shape for OPA-MSG on the concentration of MSG in the sample.
A new, rapid and sensitive microextraction technique named vortex-assisted liquid-liquid-liquid microextraction (VALLLME) is proposed. The complete extraction process involves two steps. First, a vortex-assisted liquid-liquid microextraction (VALLME) procedure was used to extract the analytes from a relatively large volume of sample (donor phase) to a small volume of organic solvent (intermediate phase). Next, a micro-vortex-assisted liquid-liquid extraction (µ-VALLE) was used to extract the target analytes from the intermediate phase to a smaller volume of aqueous solution (acceptor phase). The final extract (acceptor phase) can be directly injected into the high performance liquid chromatography or capillary electrophoresis units without any further treatments. The selection of the intermediate phase and the manipulation of pH are key parameters that ensure good extraction efficiency of the technique. The proposed technique has been successfully applied for the determination of carvedilol (used as model analyte) in biological fluid samples. The optimum extraction conditions were: toluene as intermediate phase (150 μL); pH of the donor phase, 9.5; vortex time of the VALLME, 45 s (maximum speed, 2500 rpm); 0.1M HCl (15 μL) as acceptor phase; vortexing time of the µ-VALLME, 75 s (maximum stirring speed, 2500 rpm) and salt concentration in the donor phase, 5% (w/v). Under these conditions, enrichment factors of 51- and 418-fold for VALLME step and VALLLME procedure, respectively, were achieved.
A chiral separation method coupled with capillary electrophoresis (CE) analysis for ketoconazole and miconazole enantiomers using chiral selectors such as β-cyclodextrin (β-CD) and hydroxypropyl-β-CD (HP-β-CD) was developed in this study, which included the optimisation, validation and application of the method on the antifungal cream samples. The formation of inclusion complex between the hosts (β-CD and HP-β-CD) and guests (ketoconazole and miconazole) were compared and analysed using ultraviolet-visible spectrophotometry, nuclear magnetic resonance (NMR) spectroscopy and molecular docking methods. Results from the study showed that in a concentration that ranged between 0.25 and 50 mg L-1 , the linear calibration curves of each enantiomer had a high coefficient of regression (R2 > 0.999), low limit of detection (0.075 mg L-1 ) and low limit of quantification (0.25 mg L-1 ). The relative standard deviation (RSD) of the intraday and interday analyses ranged from 0.79% to 8.01% and 3.30% to 11.43%, respectively, while the recoveries ranged from 82.0% to 105.7% (RSD < 7%, n = 3). The most probable structure of the inclusion complexes was proposed based on the findings from the molecular docking studies conducted using the PatchDock server.
The translation of stacking techniques used in capillary electrophoresis (CE) to microchip CE (MCE) in order to improve concentration sensitivity is an important area of study. The success in stacking relies on the generation and control of the stacking boundaries which is a challenge in MCE because the manipulation of solutions is not as straightforward as in CE with a single channel. Here, a simple and rapid on-line sample concentration (stacking strategy) in a battery operated nonaqueous MCE device with a commercially available double T-junction glass chip is presented. A multi-stacking approach was developed in order to circumvent the issues for stacking in nonaqueous MCE. The cationic analytes from the two loading channels were injected under field-enhanced conditions and were focused by micelle-to-solvent stacking. This was achieved by the application of high electric fields along the two loading channels and a low electric field in the separation channel, with one ground electrode in the reservoir closest to the junction. At the junction, the stacked zones were re-stacked under field-enhanced conditions and then injected into the separation channels. The multi-stacking was verified under a fluorescence microscope using Rhodamine 6G as the analyte, revealing a sensitivity enhancement factor (SEF) of 110. The stacking approach was also implemented in the nonaqueous MCE with contactless conductivity detection of the anticancer drug tamoxifen as well as its metabolites. The multi-stacking and analysis time was 40 s and 110 s, respectively, the limit of detections was from 10 to 35 ng/mL, and the SEFs were 20 to 50. The method was able to quantify the target analytes from breast cancer patients.
A rapid and green analytical method based on capillary electrophoresis with capacitively coupled contactless conductivity detection (C⁴D) for the determination of eight environmental pollutants, the biogenic amines (putrescine, cadaverine, spermidine, spermine, tyramine, 2-phenylamine, histamine and tryptamine), is described. The separation was achieved under normal polarity mode at 24 °C and 25 kV with a hydrodynamic injection (50 mbar for 5 s) and using a bare fused-silica capillary (95 cm length × 50 µm i.d.) (detection length of 10.5 cm from the outlet end of the capillary). The optimized background electrolyte consisted of 400 mM malic acid. C⁴D parameters were set at a fixed amplitude (50 V) and frequency (600 kHz). Under the optimum conditions, the method exhibited good linearity over the range of 1.0⁻100 µg mL−1 (R² ≥ 0.981). The limits of detection based on signal to noise (S/N) ratios of 3 and 10 were ≤0.029 µg mL−1. The method was used for the determination of seawater samples that were spiked with biogenic amines. Good recoveries (77⁻93%) were found.
Haemoglobin E (Hb E) is a variant of structurally abnormal haemoglobin that can be found very commonly in the Asian countries particularly the Southeast Asian [1]. [H1] Alpha thalassaemia is a red cell disorder which is caused by deletion or mutation of one or more of the four alpha globin genes leading to absence or decrease in production of alpha globin peptides [2]. This disorder is far more common in South East Asian regions and in Malaysia itself, and the gene frequency is about 4.1% [2]. The interactions of Hb E and alpha thalassaemia are evident in Kelantan which is bordered by southern Thailand. Using capillary electrophoresis (CE), a reduction of Hb E level is noticed as compared to Hb E heterozygotes. DNA analysis should be done to determine the presence of concurrent alpha thalassaemia variant. This study was done to evaluate haematological parameters using automated blood counters, morphology of red cells, Hb separation and quantitation of Hb fractions using CE and molecular analysis for alpha thalassemia. The study also aimed to discover cut off point of Hb E level in heterozygous Hb E patients with concurrent deletional alpha thalassaemia by CE.
The low conductivity of separation electrolytes employed in nonaqueous capillary electrophoresis (NACE) limits the use of on-line sample concentration or stacking by field enhancement. Herein, micelle-to-solvent stacking (MSS) was performed by the simple injection of a micellar solution plug prior to electrokinetic injection of sample prepared under field-enhanced stacking conditions (known as field-enhanced sample injection, FESI). The proposed approach allowed a 214-625-fold improvement in peak signals for targeted anticancer drugs (e.g., tamoxifen) and its major metabolites in NACE using 100% methanol-based separation electrolyte that comprised of 7.5mM deoxycholic acid sodium salt, 15mM acetic acid and 1mM 18-crown-6. These improvements yielded tamoxifen and its metabolites with 2-5 times better stacking efficiency as compared to those obtained without micellar solution injection or FESI only. This is comparable to the results typically achieved when FESI is combined with isotachophoresis (electrokinetic supercharging). The FESI-MSS-NACE was tested for the measuring levels of target drugs in plasma. The analytical figures of merit are also reported.