Displaying publications 21 - 40 of 46 in total

Abstract:
Sort:
  1. Jahan I, Begum M, Akhter S, Islam Z, Haque M, Jahan N
    J Popul Ther Clin Pharmacol, 2020 06 11;27(2):e68-e77.
    PMID: 32543162 DOI: 10.15586/jptcp.v27i2.675
    Alternate nostril breathing (ANB) is one of the best and easiest breathing exercises. ANB exercise has beneficial effects on cardiac function in healthy and diseased people. The objectives of this study were to assess the effects of ANB exercise on cardiac physiology among healthy medical students. This was a prospective interventional study that was conducted in the Department of Physiology, Chittagong Medical College (CMC), Chattogram, Bangladesh, from July 2017 to June 2018. A total of 100 research participants (RPs) aged 18-20 years, Year-I medical students of CMC, were selected. A simple random sampling method was adopted. The selection was done after the inclusion and exclusion criteria were applied. The age and body mass index (BMI) of the RPs were analogous in both the control and experimental groups. Cardiac parameters, like pulse and blood pressure (BP), were measured. The initial baseline data were recorded for both groups and after 4 weeks. The research respondents of the experimental group performed ANB exercise for 4 weeks. The mean value pulse and BP were significantly (p < 0.001) changed after breathing exercise, compared to the values before the breathing exercise. The results of this study suggest that cardiac function significantly improves after the breathing exercise. Therefore, ANB can be recommended for increasing cardiac efficiency.
    Matched MeSH terms: Heart Rate/physiology
  2. Jahan I, Begum M, Akhter S, Islam MZ, Jahan N, Samad N, et al.
    Ann Afr Med, 2021 7 3;20(2):69-77.
    PMID: 34213471 DOI: 10.4103/aam.aam_114_20
    Introduction: Alternate nostril breathing (ANB) is an effective breathing exercise with therapeutic benefits on cardiorespiratory functions for healthy and diseased individuals. This study was conducted to assess the effects of ANB exercise on cardiorespiratory tasks in healthy adults.

    Materials and Methods: This randomized experimental study was conducted in the Department of Physiology, Chittagong Medical College, Chattogram, from July 2017 to June 2018. A total of 100 1st-year students, aged between 18 and 20 years, were included by a random sampling method. Fifty participants (25 males and 25 females) were enrolled in the experimental group, while age- and body mass index-matched another 50 participants (25 males and 25 females) served as the control group. Experimental group participants performed ANB exercise for 4 weeks. Cardiorespiratory parameters (pulse rate, blood pressure, forced vital capacity, forced expiratory volume in 1st s [FEV1], and peak expiratory flow rate [PEFR] were measured. Data were taken at the start and after 4 weeks in both groups.

    Results: Independent t-test showed no significant differences in the cardiorespiratory functions between the experimental and control groups among the male and female participants, except for the females' PEFR which showed small differences. On the other hand, repeated measure ANOVA shows significant improvement in the experimental groups among males (P < 0.001-0.028) and females (P < 0.001-0.001) in all the cardiorespiratory functions measured, except for the FEV1 and PEFR among males.

    Conclusion: The results of this study suggest that cardiorespiratory functions were improved after breathing exercise, and therefore, ANB can be recommended for increasing cardiorespiratory efficiency.

    Matched MeSH terms: Heart Rate/physiology*
  3. Abdul-Kadir NA, Mat Safri N, Othman MA
    Int J Cardiol, 2016 Nov 01;222:504-8.
    PMID: 27505342 DOI: 10.1016/j.ijcard.2016.07.196
    BACKGROUND: The feasibility study of the natural frequency (ω) obtained from a second-order dynamic system applied to an ECG signal was discovered recently. The heart rate for different ECG signals generates different ω values. The heart rate variability (HRV) and autonomic nervous system (ANS) have an association to represent cardiovascular variations for each individual. This study further analyzed the ω for different ECG signals with HRV for atrial fibrillation classification.

    METHODS: This study used the MIT-BIH Normal Sinus Rhythm (nsrdb) and MIT-BIH Atrial Fibrillation (afdb) databases for healthy human (NSR) and atrial fibrillation patient (N and AF) ECG signals, respectively. The extraction of features was based on the dynamic system concept to determine the ω of the ECG signals. There were 35,031 samples used for classification.

    RESULTS: There were significant differences between the N & NSR, N & AF, and NSR & AF groups as determined by the statistical t-test (p<0.0001). There was a linear separation at 0.4s(-1) for ω of both databases upon using the thresholding method. The feature ω for afdb and nsrdb falls within the high frequency (HF) and above the HF band, respectively. The feature classification between the nsrdb and afdb ECG signals was 96.53% accurate.

    CONCLUSIONS: This study found that features of the ω of atrial fibrillation patients and healthy humans were associated with the frequency analysis of the ANS during parasympathetic activity. The feature ω is significant for different databases, and the classification between afdb and nsrdb was determined.

    Matched MeSH terms: Heart Rate/physiology*
  4. Shariat A, Cleland JA, Danaee M, Alizadeh R, Sangelaji B, Kargarfard M, et al.
    Work, 2018;60(4):549-554.
    PMID: 30103362 DOI: 10.3233/WOR-182762
    BACKGROUND: There are many potential training exercises for office workers in an attempt to prevent musculoskeletal disorders. However, to date a suitable tool to monitor the perceived exertion of those exercises does not exist.

    OBJECTIVE: The primary objective of this study was to examine the validity and reliability of the Borg CR-10 scale to monitor the perceived exertion of office exercise training.

    METHODS: The study involved 105 staff members employed in a government office with an age range from 25 to 50 years. The Borg CR-10 scale was self-administered two times, with an interval of two weeks in order to evaluate the accuracy of the original findings with a retest. Face validity and content validity were also examined.

    RESULTS: Reliability was found to be high for the Borg CR-10 scale (0.898). Additionally a high correlation between the Borg CR-10 scale and Visual Analog Scale (VAS) was identified (rs = 0.754, P 

    Matched MeSH terms: Heart Rate/physiology
  5. Aimie-Salleh N, Malarvili MB, Whittaker AC
    Med Biol Eng Comput, 2019 Jun;57(6):1229-1245.
    PMID: 30734153 DOI: 10.1007/s11517-019-01958-3
    Adverse childhood experiences have been suggested to cause changes in physiological processes and can determine the magnitude of the stress response which might have a significant impact on health later in life. To detect the stress response, biomarkers that represent both the Autonomic Nervous System (ANS) and Hypothalamic-Pituitary-Adrenal (HPA) axis are proposed. Among the available biomarkers, Heart Rate Variability (HRV) has been proven as a powerful biomarker that represents ANS. Meanwhile, salivary cortisol has been suggested as a biomarker that reflects the HPA axis. Even though many studies used multiple biomarkers to measure the stress response, the results for each biomarker were analyzed separately. Therefore, the objective of this study is to propose a fusion of ANS and HPA axis biomarkers in order to classify the stress response based on adverse childhood experience. Electrocardiograph, blood pressure (BP), pulse rate (PR), and salivary cortisol (SCort) measures were collected from 23 healthy participants; 11 participants had adverse childhood experience while the remaining 12 acted as the no adversity control group. HRV was then computed from the ECG and the HRV features were extracted. Next, the selected HRV features were combined with the other biomarkers using Euclidean distance (ed) and serial fusion, and the performance of the fused features was compared using Support Vector Machine. From the result, HRV-SCort using Euclidean distance achieved the most satisfactory performance with 80.0% accuracy, 83.3% sensitivity, and 78.3% specificity. Furthermore, the performance of the stress response classification of the fused biomarker, HRV-SCort, outperformed that of the single biomarkers: HRV (61% Accuracy), Cort (59.4% Accuracy), BP (78.3% accuracy), and PR (53.3% accuracy). From this study, it was proven that the fused biomarkers that represent both ANS and HPA (HRV-SCort) able to demonstrate a better classification performance in discriminating the stress response. Furthermore, a new approach for classification of stress response using Euclidean distance and SVM named as ed-SVM was proven to be an effective method for the HRV-SCort in classifying the stress response from PASAT. The robustness of this method is crucial in contributing to the effectiveness of the stress response measures and could further be used as an indicator for future health. Graphical abstract ᅟ.
    Matched MeSH terms: Heart Rate/physiology*
  6. Md Lazin Md Lazim MR, Aminuddin A, Chellappan K, Ugusman A, Hamid AA, Wan Ahmad WAN, et al.
    PMID: 32290168 DOI: 10.3390/ijerph17072591
    Finger photoplethysmography (PPG) waveform is blood volume change of finger microcirculation that reflects vascular function. Reflection index (RI), stiffness index (SI) and second derivative of photoplethysmogram (SDPPG) are derived from PPG waveforms proposed as cardiovascular disease (CVD) markers. Heart rate (HR) is a known factor that affects vascular function. Individual resting HR variation may affect RI, SI and SDPPG. This review aims to identify studies about the relationship between HR with RI, SI and SDPPG among humans. A literature search was conducted in Medline via the Ebscohost and Scopus databases to find relevant articles published within 11 years. The main inclusion criteria were articles in the English language that discuss the relationship between HR with RI, SI and SDPPG using PPG among humans. The search found 1960 relevant articles but only six articles that met the inclusion criteria. SI and RI showed an association with HR. SDPPG (SDPPG-b/SDPPG-a ratio, SDPPG-d/SDPPG-a ratio, aging index (AGI) and revised aging index (RAGI)) also had an association with HR. Only RI had a considerable association with HR, the association between SI and HR was non-considerable and the association between HR and SDPPG was inconclusive. Further interventional studies should be conducted to investigate this issue, as a variation in resting HR may challenge the validity of PPG-based CVD markers.
    Matched MeSH terms: Heart Rate/physiology*
  7. Borhanuddin BK, Abdul Latiff H, Mohamed Yusof AK
    Cardiol Young, 2022 Dec;32(12):1994-1998.
    PMID: 35707919 DOI: 10.1017/S1047951122000154
    BACKGROUND: CT is an accepted non-invasive imaging tool to assess the coronary arteries in adults; however, its utilisation in children is limited by high heart rate and lack of standardised protocol. We sought to assess diagnostic quality and factors that affect image quality of CT in assessing coronary artery lesions in Kawasaki patients less than 18 years of age.

    METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.

    RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).

    CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.

    Matched MeSH terms: Heart Rate/physiology
  8. Husain R, Cheah SH, Duncan MT
    Singapore Med J, 1996 Aug;37(4):398-401.
    PMID: 8993142
    The investigation examined the possibility that observance of Ramadan by Moslems in Malaysia is associated with modification of circulatory parameters. Cardiovascular reactivity was investigated employing the cold hand immersion test as the stressor stimulus. Resultant data showed increased blood pressures and vascular resistance during Ramadan in the absence of cold stimulus while the magnitude of the maximal cardiac and vascular response to the applied stressor which served as indicators of reactivity was not affected by the Ramadan situation.
    Matched MeSH terms: Heart Rate/physiology
  9. Poznanski RR, Cacha LA, Al-Wesabi YMS, Ali J, Bahadoran M, Yupapin PP, et al.
    Sci Rep, 2017 May 31;7(1):2746.
    PMID: 28566682 DOI: 10.1038/s41598-017-01849-3
    A model of solitonic conduction in neuronal branchlets with microstructure is presented. The application of cable theory to neurons with microstructure results in a nonlinear cable equation that is solved using a direct method to obtain analytical approximations of traveling wave solutions. It is shown that a linear superposition of two oppositely directed traveling waves demonstrate solitonic interaction: colliding waves can penetrate through each other, and continue fully intact as the exact pulses that entered the collision. These findings indicate that microstructure when polarized can sustain solitary waves that propagate at a constant velocity without attenuation or distortion in the absence of synaptic transmission. Solitonic conduction in a neuronal branchlet arising from polarizability of its microstructure is a novel signaling mode of electrotonic signals in thin processes (<0.5 μm diameter).
    Matched MeSH terms: Heart Rate/physiology
  10. Deuchars SA, Lall VK, Clancy J, Mahadi M, Murray A, Peers L, et al.
    Exp Physiol, 2018 Mar 01;103(3):326-331.
    PMID: 29205954 DOI: 10.1113/EP086433
    What is the topic of this review? This review briefly considers what modulates sympathetic nerve activity and how it may change as we age or in pathological conditions. It then focuses on transcutaneous vagus nerve stimulation, a method of neuromodulation in autonomic cardiovascular control. What advances does it highlight? The review considers the pathways involved in eliciting the changes in autonomic balance seen with transcutaneous vagus nerve stimulation in relationship to other neuromodulatory techniques. The autonomic nervous system, consisting of the sympathetic and parasympathetic branches, is a major contributor to the maintenance of cardiovascular variables within homeostatic limits. As we age or in certain pathological conditions, the balance between the two branches changes such that sympathetic activity is more dominant, and this change in dominance is negatively correlated with prognosis in conditions such as heart failure. We have shown that non-invasive stimulation of the tragus of the ear increases parasympathetic activity and reduces sympathetic activity and that the extent of this effect is correlated with the baseline cardiovascular parameters of different subjects. The effects could be attributable to activation of the afferent branch of the vagus and, potentially, other sensory nerves in that region. This indicates that tragus stimulation may be a viable treatment in disorders where autonomic activity to the heart is compromised.
    Matched MeSH terms: Heart Rate/physiology
  11. Hamzaid NA, Tean LT, Davis GM, Suhaimi A, Hasnan N
    Spinal Cord, 2015 May;53(5):375-9.
    PMID: 25366533 DOI: 10.1038/sc.2014.187
    STUDY DESIGN: Prospective study of two cases.

    OBJECTIVES: To describe the effects of electrical stimulation (ES) therapy in the 4-week management of two sub-acute spinal cord-injured (SCI) individuals (C7 American Spinal Injury Association Impairment Scale (AIS) B and T9 AIS (B)).

    SETTING: University Malaya Medical Centre, Kuala Lumpur, Malaysia.

    METHODS: A diagnostic tilt-table test was conducted to confirm the presence of orthostatic hypotension (OH) based on the current clinical definitions. Following initial assessment, subjects underwent 4 weeks of ES therapy 4 times weekly for 1 h per day. Post-tests tilt table challenge, both with and without ES on their rectus abdominis, quadriceps, hamstrings and gastrocnemius muscles, was conducted at the end of the study (week 5). Subjects' blood pressures (BP) and heart rates (HR) were recorded every minute during pre-test and post-tests. Orthostatic symptoms, as well as the maximum tolerance time that the subjects could withstand head up tilt at 60°, were recorded.

    RESULTS: Subject A improved his orthostatic symptoms, but did not recover from clinically defined OH based on the 20-min duration requirement. With concurrent ES therapy, 60° head up tilt BP was 89/62 mm Hg compared with baseline BP of 115/71 mm Hg. Subject B fully recovered from OH demonstrated by BP of 105/71 mm Hg during the 60° head up tilt compared with baseline BP of 124/77 mm Hg. Both patients demonstrated longer tolerance time during head up tilt with concomitant ES (subject A: pre-test 4 min, post-test without ES 6 min, post-test with ES 12 min; subject B: pre-test 4 min, post-test without ES 28 min, post-test with ES 60 min).

    CONCLUSIONS: Weekly ES therapy had positive effect on OH management in sub-acute SCI individuals.

    Matched MeSH terms: Heart Rate/physiology
  12. Khan SA, Sattar MA, Rathore HA, Abdulla MH, Ud Din Ahmad F, Ahmad A, et al.
    Acta Physiol (Oxf), 2014 Mar;210(3):690-700.
    PMID: 24438102 DOI: 10.1111/apha.12237
    There is evidence that in chronic renal failure, the sympathetic nervous system is activated. This study investigated the role of the renal innervation in suppressing high- and low-pressure baroreflex control of renal sympathetic nerve activity and heart rate in cisplatin-induced renal failure.
    Matched MeSH terms: Heart Rate/physiology*
  13. Sahayadhas A, Sundaraj K, Murugappan M
    Australas Phys Eng Sci Med, 2013 Jun;36(2):243-50.
    PMID: 23719977 DOI: 10.1007/s13246-013-0200-6
    Driver drowsiness has been one of the major causes of road accidents that lead to severe trauma, such as physical injury, death, and economic loss, which highlights the need to develop a system that can alert drivers of their drowsy state prior to accidents. Researchers have therefore attempted to develop systems that can determine driver drowsiness using the following four measures: (1) subjective ratings from drivers, (2) vehicle-based measures, (3) behavioral measures and (4) physiological measures. In this study, we analyzed the various factors that contribute towards drowsiness. A total of 15 male subjects were asked to drive for 2 h at three different times of the day (00:00-02:00, 03:00-05:00 and 15:00-17:00 h) when the circadian rhythm is low. The less intrusive physiological signal measurements, ECG and EMG, are analyzed during this driving task. Statistically significant differences in the features of ECG and sEMG signals were observed between the alert and drowsy states of the drivers during different times of day. In the future, these physiological measures can be fused with vision-based measures for the development of an efficient drowsiness detection system.
    Matched MeSH terms: Heart Rate/physiology*
  14. Kulur AB, Haleagrahara N, Adhikary P, Jeganathan PS
    Arq. Bras. Cardiol., 2009 Jun;92(6):423-9, 440-7, 457-63.
    PMID: 19629309
    BACKGROUND: Reduced heart rate variability is associated with an unfavorable prognosis in patients with ischemic heart disease and diabetes. Whether change in breathing pattern can modify the risk factor in these patients has not been definitely proved.
    OBJECTIVE: To evaluate the effect of diaphragmatic breathing on heart rate variability (HRV) in ischemic heart disease patients with diabetes.
    METHODS: Study population consisted of 145 randomly selected male patients of which 45 had ischemic heart disease (IHD), 52 had IHD and diabetes (IHD-DM) and the remaining 48 had IHD and diabetic neuropathy (IHD-DN). HRV was assessed by 5 minute-electrocardiogram using the time domain method. The intervention group was divided into compliant and non-compliant groups and follow-up recording was carried out after three months and one year.
    RESULTS: Baseline recordings showed a significant decrease in HRV in ischemic heart disease (IHD) patients with or without diabetes (p<0.01). IHD patients had higher HRV than IHD patients with diabetes (p<0.01) or diabetic neuropathy (p<0.01). Increase in HRV was observed in patients who practiced diaphragmatic breathing for three months (IHD-DM: p<0.01; IHD-DN: p<0.05) and for one year (IHD-DM: p<0.01; IHD-DN: p<0.01). The HRV significantly decreased after one year in non-compliant patients. The regular practice of diaphragmatic breathing also improved the glycemic index in these patients.
    CONCLUSION: The regular practice of diaphragmatic breathing significantly improves heart rate variability with a favorable prognostic picture in ischemic heart disease patients who have diabetes. These effects seem to be potentially beneficial in the management of IHD patients with diabetes.
    Matched MeSH terms: Heart Rate/physiology*
  15. Ibrahimy MI, Ahmed F, Mohd Ali MA, Zahedi E
    IEEE Trans Biomed Eng, 2003 Feb;50(2):258-62.
    PMID: 12665042
    An algorithm based on digital filtering, adaptive thresholding, statistical properties in the time domain, and differencing of local maxima and minima has been developed for the simultaneous measurement of the fetal and maternal heart rates from the maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. A microcontroller-based system has been used to implement the algorithm in real-time. A Doppler ultrasound fetal monitor was used for statistical comparison on five volunteers with low risk pregnancies, between 35 and 40 weeks of gestation. Results showed an average percent root mean square difference of 5.32% and linear correlation coefficient from 0.84 to 0.93. The fetal heart rate curves remained inside a +/- 5-beats-per-minute limit relative to the reference ultrasound method for 84.1% of the time.
    Matched MeSH terms: Heart Rate/physiology
  16. Goh CH, Ng SC, Kamaruzzaman SB, Chin AV, Tan MP
    Medicine (Baltimore), 2017 Oct;96(42):e8193.
    PMID: 29049203 DOI: 10.1097/MD.0000000000008193
    The aim of this study was to determine the relationship between falls and beat-to-beat blood pressure (BP) variability.Continuous noninvasive BP measurement is as accurate as invasive techniques. We evaluated beat-to-beat supine and standing BP variability (BPV) using time and frequency domain analysis from noninvasive continuous BP recordings.A total of 1218 older adults were selected. Continuous BP recordings obtained were analyzed to determine standard deviation (SD) and root mean square of real variability (RMSRV) for time domain BPV and fast-Fourier transform low frequency (LF), high frequency (HF), total power spectral density (PSD), and LF:HF ratio for frequency domain BPV.Comparisons were performed between 256 (21%) individuals with at least 1 fall in the past 12 months and nonfallers. Fallers were significantly older (P = .007), more likely to be female (P = .006), and required a longer time to complete the Timed-Up and Go test (TUG) and frailty walk test (P ≤ .001). Standing systolic BPV (SBPV) was significantly lower in fallers compared to nonfallers (SBPV-SD, P = .016; SBPV-RMSRV, P = .033; SBPV-LF, P = .003; SBPV-total PSD, P = .012). Nonfallers had significantly higher supine to standing ratio (SSR) for SBPV-SD, SBPV-RMSRV, and SBPV-total PSD (P = .017, P = .013, and P = .009). In multivariate analyses, standing BPV remained significantly lower in fallers compared to nonfallers after adjustment for age, sex, diabetes, frailty walk, and supine systolic BP. The reduction in frequency-domain SSR among fallers was attenuated by supine systolic BP, TUG, and frailty walk.In conclusion, reduced beat-to-beat BPV while standing is independently associated with increased risk of falls. Changes between supine and standing BPV are confounded by supine BP and walking speed.
    Matched MeSH terms: Heart Rate/physiology
  17. Müller AM, Wang NX, Yao J, Tan CS, Low ICC, Lim N, et al.
    JMIR Mhealth Uhealth, 2019 10 02;7(10):e14120.
    PMID: 31579026 DOI: 10.2196/14120
    BACKGROUND: Wrist-worn activity trackers are popular, and an increasing number of these devices are equipped with heart rate (HR) measurement capabilities. However, the validity of HR data obtained from such trackers has not been thoroughly assessed outside the laboratory setting.

    OBJECTIVE: This study aimed to investigate the validity of HR measures of a high-cost consumer-based tracker (Polar A370) and a low-cost tracker (Tempo HR) in the laboratory and free-living settings.

    METHODS: Participants underwent a laboratory-based cycling protocol while wearing the two trackers and the chest-strapped Polar H10, which acted as criterion. Participants also wore the devices throughout the waking hours of the following day during which they were required to conduct at least one 10-min bout of moderate-to-vigorous physical activity (MVPA) to ensure variability in the HR signal. We extracted 10-second values from all devices and time-matched HR data from the trackers with those from the Polar H10. We calculated intraclass correlation coefficients (ICCs), mean absolute errors, and mean absolute percentage errors (MAPEs) between the criterion and the trackers. We constructed decile plots that compared HR data from Tempo HR and Polar A370 with criterion measures across intensity deciles. We investigated how many HR data points within the MVPA zone (≥64% of maximum HR) were detected by the trackers.

    RESULTS: Of the 57 people screened, 55 joined the study (mean age 30.5 [SD 9.8] years). Tempo HR showed moderate agreement and large errors (laboratory: ICC 0.51 and MAPE 13.00%; free-living: ICC 0.71 and MAPE 10.20%). Polar A370 showed moderate-to-strong agreement and small errors (laboratory: ICC 0.73 and MAPE 6.40%; free-living: ICC 0.83 and MAPE 7.10%). Decile plots indicated increasing differences between Tempo HR and the criterion as HRs increased. Such trend was less pronounced when considering the Polar A370 HR data. Tempo HR identified 62.13% (1872/3013) and 54.27% (5717/10,535) of all MVPA time points in the laboratory phase and free-living phase, respectively. Polar A370 detected 81.09% (2273/2803) and 83.55% (9323/11,158) of all MVPA time points in the laboratory phase and free-living phase, respectively.

    CONCLUSIONS: HR data from the examined wrist-worn trackers were reasonably accurate in both the settings, with the Polar A370 showing stronger agreement with the Polar H10 and smaller errors. Inaccuracies increased with increasing HRs; this was pronounced for Tempo HR.

    Matched MeSH terms: Heart Rate/physiology*
  18. Sharifah Maimunah SM, Hashim HA
    Percept Mot Skills, 2016 Feb;122(1):227-37.
    PMID: 27420318 DOI: 10.1177/0031512515625383
    This study compares two versions of progressive muscle relaxation (PMR) training (7 and 16 muscle groups) on oxygen consumption (VO2), heart rates, rating of perceived exertion and choice reaction time. Football (soccer) players (N = 26; M age = 13.4 yr., SD = 0.5) were randomly assigned to either 7 muscle groups PMR, 16 muscle groups PMR, or a control group. PMR training requires the participants to tense a muscle, hold the muscle contraction, and then relax it. Measurement was conducted prior to and after the completion of 12 sessions of PMR. The dependent variables were measured following four bouts of intermittent exercise consisting of 12 min. of running at 60% VO2max for 10 min. followed by running at 90% VO2max for 2 min. with a 3-min. rest for each bout. Lower VO2, heart rate, perceived exertion, and quicker reaction time were expected in both relaxation groups compared to the control group. The results revealed a significant reduction in heart rates and choice reaction time for both relaxation groups, but the longer version produced significantly quicker choice reaction time.
    Matched MeSH terms: Heart Rate/physiology*
  19. Lim E, Chan GS, Dokos S, Ng SC, Latif LA, Vandenberghe S, et al.
    PLoS One, 2013;8(10):e77357.
    PMID: 24204817 DOI: 10.1371/journal.pone.0077357
    A lumped parameter model of the cardiovascular system has been developed and optimized using experimental data obtained from 13 healthy subjects during graded head-up tilt (HUT) from the supine position to [Formula: see text]. The model includes descriptions of the left and right heart, direct ventricular interaction through the septum and pericardium, the systemic and pulmonary circulations, nonlinear pressure volume relationship of the lower body compartment, arterial and cardiopulmonary baroreceptors, as well as autoregulatory mechanisms. A number of important features, including the separate effects of arterial and cardiopulmonary baroreflexes, and autoregulation in the lower body, as well as diastolic ventricular interaction through the pericardium have been included and tested for their significance. Furthermore, the individual effect of parameter associated with heart failure, including LV and RV contractility, baseline systemic vascular resistance, pulmonary vascular resistance, total blood volume, LV diastolic stiffness and reflex gain on HUT response have also been investigated. Our fitted model compares favorably with our experimental measurements and published literature at a range of tilt angles, in terms of both global and regional hemodynamic variables. Compared to the normal condition, a simulated congestive heart failure condition produced a blunted response to HUT with regards to the percentage changes in cardiac output, stroke volume, end diastolic volume and effector response (i.e., heart contractility, venous unstressed volume, systemic vascular resistance and heart rate) with progressive tilting.
    Matched MeSH terms: Heart Rate/physiology
  20. Yusof AP, Yusoff NH, Suhaimi FW, Coote JH
    Auton Neurosci, 2009 Jun 15;148(1-2):50-4.
    PMID: 19349212 DOI: 10.1016/j.autneu.2009.03.005
    The aim of the present study was to determine if paraventricular-spinal vasopressin neurones participate in the sympatho-inhibitory effects of systemically administered atrial natriuretic peptide (ANP) on renal sympathetic nerve activity (RSNA). Experiments were carried out on male Sprague-Dawley rats anesthetized with 1.3 g/kg urethane. Changes in mean arterial pressure (mm Hg), heart rate (beats per minute) and RSNA (%) were measured following intravenous bolus administration of ANP (250 ng, 500 ng and 5 microg). Intrathecal application of selective V 1a receptor antagonist was performed to test for the involvement of supraspinal vasopressin pathways in mediating the effect on sympathetic outflow evoked by intravenous ANP administration. The results obtained demonstrated that both low and high doses of ANP caused renal sympathoinhibition (250 ng; - 7.5 +/- 1%, 500 ng; - 14.2 +/- 1%, 5 microg; - 16.4 +/- 2%), concomitant with vasodilation and bradycardia. After spinal vasopressin receptor blockade, the inhibitory effects of ANP were prevented and there was a small renal sympatho-excitation (250 ng; + 1.7 +/- 0.2%, 500 ng; + 6.1 +/- 0.03%, 5 microg; + 8.0 +/- 0.03%, P < 0.05). Therefore, the renal sympathetic nerve inhibition elicited by circulating ANP is dependent on the efficacy of a well established supraspinal vasopressin pathway. Since supraspinal vasopressin neurones without exception excite renal sympathetic neurones, it is suggested that ANP elicits this effect by activating cardiac vagal afferents that inhibit the spinally projecting vasopressin neurones at their origin in the paraventricular nucleus of the hypothalamus.
    Matched MeSH terms: Heart Rate/physiology
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links