Displaying publications 21 - 40 of 2007 in total

Abstract:
Sort:
  1. Abd Rahman MN, Abdul Rani MR, Rohani JM
    J Hum Ergol (Tokyo), 2011 Dec;40(1-2):19-36.
    PMID: 25665205 DOI: 10.11183/jhe.40.19
    This paper describes the development of the Workplace Ergonomic Risk Assessment (WERA) for investigating the physical risk factor associated with work-related musculoskeletal disorders (WMSDs). The initial development of WERA tool involved the following procedures: (1) first stage, development of WERA prototype from literature review, (2) second stage, evaluation of the psychometric properties including (a) validity trials and (b) reliability and usability trials. In the validity trials, the relationship of the individual WERA body part scores to the development of pain or discomfort is statistically significant for the wrist, shoulder and back regions. It shows that the WERA assessment provided a good indication of work-related musculoskeletal disorders which might be reported as pain, ache or discomfort in the relevant body regions. In the reliability trials, the results of inter-observer reliability shows that moderate agreement among the observers while from the feedback questionnaire survey about the usability of WERA tool, all participants including expert and management teams agreed that the prototype of WERA tool was easy and quick to use, applicable to workplace assessment for the wide range of job/task and valuable at work. It was confirmed that there was no need of training required to do WERA assessment. Therefore, the WERA assessment has been designed for easy and quick use, and for those who are trained to use it do not need previous skills in observation techniques although this would be an advantage. As WERA is a pen and paper technique that can be used without any special equipment, WERA assessment can be done in any space of workplaces without disruption to the task that have been observed.
    Matched MeSH terms: Reproducibility of Results
  2. Shalash M, Makahleh A, Salhimi SM, Saad B
    Talanta, 2017 Nov 01;174:428-435.
    PMID: 28738603 DOI: 10.1016/j.talanta.2017.06.039
    A vortex-assisted liquid-liquid-liquid microextraction method followed by high performance liquid chromatography-diode array detection for the determination of fourteen phenolic acids (cinnamic, m-coumaric, chlorogenic, syringic, ferulic, o-coumaric, p-coumaric, vanillic, p-hydroxybenzoic, caffeic, 2, 4-dihydroxybenzoic, sinapic, gentisic and gallic acids) in honey, iced tea and canned coffee drink samples has been developed. The separation was achieved using a Poroshell 120-EC-C18 column under a gradient elution at a flow rate of 0.6mLmin-1 and mobile phase composed of methanol and acetic acid (1%, v/v). Under the optimum chromatographic conditions, the fourteen phenolic acids were separated in less than 32min. The extraction was performed using a small volume (400µL) of ternary organic solvents (1-pentanol, propyl acetate and 1-hexanol) dispersed into the aqueous sample (10mL) and assisted by vortex agitation (2500rpm for 45s), the analytes were next back-extracted from the organic solvent using 0.02M KOH (40µL) with vortex speed and time of 2500rpm and 60s, respectively. Under these conditions, enrichment factors of 30-193-fold were achieved. The limits of detection (LODs) were 0.05-0.68µgL-1. Recoveries in honey, iced tea and canned coffee drinks were in the range 72.2-112%. The method was successfully applied for the determination of the phenolic acids in honey, iced tea and canned coffee drinks.
    Matched MeSH terms: Reproducibility of Results
  3. Ahmad K, Yan Y, Bless D
    J Voice, 2012 Nov;26(6):751-9.
    PMID: 22633334 DOI: 10.1016/j.jvoice.2011.12.002
    A high proportion of the geriatric population suffers from presbylaryngis and presbyphonia; however, our knowledge of vibratory patterns in this population is almost nonexistent. In this study, we investigate the vocal fold vibratory patterns of healthy elderly females to determine which features or combination of them could best describe the geriatric voices.
    Matched MeSH terms: Reproducibility of Results
  4. Sui CF, Ming LC, Neoh CF, Ibrahim B
    PMID: 26316735 DOI: 10.2147/COPD.S84618
    Background: This study utilized a validated combination of a COPD Population Screener
    (COPD-PS) questionnaire and a handheld spirometric device as a screening tool for patients at high risk of COPD, such as smokers. The study aimed to investigate and pilot the feasibility and application of this combined assessment, which we termed the “VitalQPlus”, as a screening tool for the early detection of COPD, especially in primary care settings.
    Methods: This was a cross-sectional study screening potentially undiagnosed COPD patients using a validated five-item COPD-PS questionnaire together with a handheld spirometric device. Patients were recruited from selected Malaysian government primary care health centers.
    Results: Of the total of 83 final participants, only 24.1% (20/83) were recruited from Perak and Penang (peninsular Malaysia) compared to 75.9% (63/83) from Sabah (Borneo region). Our dual assessment approach identified 8.4% of the surveyed patients as having potentially undiagnosed COPD. When only the Vitalograph COPD-6 screening tool was used, 15.8% of patients were detected with a forced expiratory volume in 1 second/forced expiratory volume in 6 seconds (FEV1/FEV6) ratio at <0.75, while 35.9% of patients were detected with the COPD-PS questionnaire. These findings suggested that this dual assessment approach has a greater chance of identifying potentially undiagnosed COPD patients compared to the Vitalograph COPD-6 or COPD-PS questionnaire when used alone. Our findings show that patients with more symptoms (scores of >=5) yielded twice the percentage of outcomes of FEV1/FEV6 <0.75 compared to patients with fewer COPD symptoms (scores <5).
    Conclusion: With the availability of a simple screening questionnaire and the COPD-6, there is an opportunity easily to make patients more aware of their lung symptoms and to encourage the provision of early treatment. The proposed dual assessment approach, which we termed the VitalQPlus, may play a profound role in the early diagnosis of COPD, which is crucial in improving the clinical management of the disease.
    Keywords: spirometry, pulmonary function test, chronic obstructive pulmonary disease,
    airway obstruction
    Matched MeSH terms: Reproducibility of Results
  5. Yap HJ, Taha Z, Dawal SZ, Chang SW
    PLoS One, 2014;9(10):e109692.
    PMID: 25360663 DOI: 10.1371/journal.pone.0109692
    Traditional robotic work cell design and programming are considered inefficient and outdated in current industrial and market demands. In this research, virtual reality (VR) technology is used to improve human-robot interface, whereby complicated commands or programming knowledge is not required. The proposed solution, known as VR-based Programming of a Robotic Work Cell (VR-Rocell), consists of two sub-programmes, which are VR-Robotic Work Cell Layout (VR-RoWL) and VR-based Robot Teaching System (VR-RoT). VR-RoWL is developed to assign the layout design for an industrial robotic work cell, whereby VR-RoT is developed to overcome safety issues and lack of trained personnel in robot programming. Simple and user-friendly interfaces are designed for inexperienced users to generate robot commands without damaging the robot or interrupting the production line. The user is able to attempt numerous times to attain an optimum solution. A case study is conducted in the Robotics Laboratory to assemble an electronics casing and it is found that the output models are compatible with commercial software without loss of information. Furthermore, the generated KUKA commands are workable when loaded into a commercial simulator. The operation of the actual robotic work cell shows that the errors may be due to the dynamics of the KUKA robot rather than the accuracy of the generated programme. Therefore, it is concluded that the virtual reality based solution approach can be implemented in an industrial robotic work cell.
    Matched MeSH terms: Reproducibility of Results
  6. Norhayati MN, Mofreh SAM, Azman YM
    PMID: 34066534 DOI: 10.3390/ijerph18094949
    Frontline healthcare providers are exposed to indirect trauma through dealing with traumatized patients. This puts them at risk of vicarious traumatization. In response to the COVID-19 pandemic, this study seeks to establish the psychometric properties of the Malay version of the Vicarious Traumatization Questionnaire among healthcare providers. A cross-sectional study was conducted. The translated Malay version of the Vicarious Traumatization Questionnaire was completed by 352 healthcare providers in Kelantan, Malaysia. The data was entered using IBM SPSS Statistics version 26.0 (SPSS Inc., Chicago, IL, USA, 2019), and descriptive analysis was performed. The psychometric properties of the scale were assessed in two phases. The Rasch model to assess the validity and reliability was performed using Winsteps version 3.72.3. The confirmatory factor analysis using the structural equation modeling was performed using AMOS version 23.0. The Rasch analysis showed that the 38 items, in two constructs, had high item reliability and item separation at 0.97 and item separation at 5.36, respectively, while good person reliability and person separation were at 0.95 and 4.58, respectively. The correlations of all persons and items are greater than 0.20. There are no misfitting or overfitting items in the outfit MNSQ. There are four items that are challenging in answering the scale. The final model of the confirmatory factor analysis shows two constructs with 38 items demonstrating acceptable factor loadings, domain to domain correlation, and best fit (Chi-squared/degree of freedom = 4.73; Tucker-Lewis index = 0.94; comparative fit index = 0.94; and root mean square error of approximation = 0.10). Composite reliability and average variance extracted of the domains were higher than 0.7 and 0.5, respectively. The Vicarious Traumatization Questionnaire tested among healthcare providers has been shown to valid and reliable to assess vicarious traumatization.
    Matched MeSH terms: Reproducibility of Results
  7. Bong CH, Lau TL, Ghani AA
    Water Sci Technol, 2013;67(2):395-403.
    PMID: 23168641 DOI: 10.2166/wst.2012.580
    The current study aims to verify the existing equations for incipient motion for a rigid rectangular channel. Data from experimental work on incipient motion from a rectangular flume with two different widths, namely 0.3 and 0.6 m, were compared with the critical velocity value predicted by the equations of Novak & Nalluri and El-Zaemey. The equation by El-Zaemey performed better with an average discrepancy ratio value of 1.06 compared with the equation by Novak & Nalluri with an average discrepancy ratio value of 0.87. However, as the sediment deposit thickness increased, the equation by El-Zaemey became less accurate. A plot on the Shields Diagram using the experimental data had shown the significant effect of the sediment deposit thickness where, as the deposit becomes thicker, the dimensionless shear stress θ value also increased. A new equation had been proposed by incorporating the sediment deposit thickness. The new equation gave improved prediction with an average discrepancy ratio value of 1.02.
    Matched MeSH terms: Reproducibility of Results
  8. Abd Razak RA, Ahmad Tarmizi AH, Abdul Hammid AN, Kuntom A, Ismail IS, Sanny M
    PMID: 31437078 DOI: 10.1080/19440049.2019.1654139
    This study was conducted to investigate on the effect of different sampling regions of palm-refined oils and fats on the 2- and 3-monochloropropanediol fatty acid esters (MCPDE) and glycidol fatty acid esters (GE) levels. The American Oil Chemists' Society (AOCS) Official Method Cd 29a-13 on the determination of MCPDE and GE in edible oils and fats by acid transesterification was successfully verified and optimised, with slight modification using 7890A Agilent GC system equipped with 5975C quadrupole detector. The determined limits of detection (LOD) for MCPDE were 0.02 mg kg-1 and 0.05 mg kg-1 for GE. The method performance has showed good recovery between 80% and 120% for all pertinent compounds with seven replicates assayed in three separate days. Round robin test with two European laboratories, i.e. Eurofins and SGS, has shown compliance results with those of the present study. Among the sampling regions, only one refinery located in the central region of Malaysia showed a significant increment of the MCPDE and GE levels after refining process. The GE level averaging at 2.5 mg kg-1 was slightly higher than that of 3-MCPDE averaging at 1.3 mg kg-1. Both esters were preferentially partitioned into the liquid phase rather than the solid phase after fractionation. However, the overall results exhibited no direct correlation between the esters content and the different sampling locations of the palm oil products in Malaysia. Analysis of total chlorine content also displayed significant variations between sampling locations which clearly show its effect on the chlorine content in the CPO samples.
    Matched MeSH terms: Reproducibility of Results
  9. Farook TH, Rashid F, Alam MK, Dudley J
    Clin Oral Investig, 2023 Feb;27(2):489-504.
    PMID: 36577849 DOI: 10.1007/s00784-022-04835-w
    BACKGROUND: To explore the digitisation of jaw movement trajectories through devices and discuss the physiological factors and device-dependent variables with their subsequent effects on the jaw movement analyses.

    METHODS: Based on predefined eligibility criteria, the search was conducted following PRISMA-P 2015 guidelines on MEDLINE, EBSCO Host, Scopus, PubMed, and Web of Science databases in 2022 by 2 reviewers. Articles then underwent Cochrane GRADE approach and JBI critical appraisal for certainty of evidence and bias evaluation.

    RESULTS: Thirty articles were included following eligibility screening. Both in vitro experiments (20%) and in vivo (80%) devices ranging from electronic axiography, electromyography, optoelectronic and ultrasonic, oral or extra-oral tracking, photogrammetry, sirognathography, digital pressure sensors, electrognathography, and computerised medical-image tracing were documented. 53.53% of the studies were rated below "moderate" certainty of evidence. Critical appraisal showed 80% case-control investigations failed to address confounding variables while 90% of the included non-randomised experimental studies failed to establish control reference.

    CONCLUSION: Mandibular and condylar growth, kinematic dysfunction of the neuromuscular system, shortened dental arches, previous orthodontic treatment, variations in habitual head posture, temporomandibular joint disorders, fricative phonetics, and to a limited extent parafunctional habits and unbalanced occlusal contact were identified confounding variables that shaped jaw movement trajectories but were not highly dependent on age, gender, or diet. Realistic variations in device accuracy were found between 50 and 330 µm across the digital systems with very low interrater reliability for motion tracing from photographs. Forensic and in vitro simulation devices could not accurately recreate variations in jaw motion and muscle contractions.

    Matched MeSH terms: Reproducibility of Results
  10. Saad MA, Jaafar R, Chellappan K
    Sensors (Basel), 2023 Jun 12;23(12).
    PMID: 37420692 DOI: 10.3390/s23125526
    Data gathering in wireless sensor networks (WSNs) is vital for deploying and enabling WSNs with the Internet of Things (IoTs). In various applications, the network is deployed in a large-scale area, which affects the efficiency of the data collection, and the network is subject to multiple attacks that impact the reliability of the collected data. Hence, data collection should consider trust in sources and routing nodes. This makes trust an additional optimization objective of the data gathering in addition to energy consumption, traveling time, and cost. Joint optimization of the goals requires conducting multiobjective optimization. This article proposes a modified social class multiobjective particle swarm optimization (SC-MOPSO) method. The modified SC-MOPSO method is featured by application-dependent operators named interclass operators. In addition, it includes solution generation, adding and deleting rendezvous points, and moving to the upper and lower class. Considering that SC-MOPSO provides a set of nondominated solutions as a Pareto front, we employed one of the multicriteria decision-making (MCDM) methods, i.e., simple additive sum (SAW), for selecting one of the solutions from the Pareto front. The results show that both SC-MOPSO and SAW are superior in terms of domination. The set coverage of SC-MOPSO is 0.06 dominant over NSGA-II compared with only a mastery of 0.04 of NSGA-II over SC-MOPSO. At the same time, it showed competitive performance with NSGA-III.
    Matched MeSH terms: Reproducibility of Results
  11. Tayyari F, Yusof F, Vymyslicky M, Tan O, Huang D, Flanagan JG, et al.
    Invest Ophthalmol Vis Sci, 2014 Dec;55(12):7716-25.
    PMID: 25335983 DOI: 10.1167/iovs.14-14430
    The purpose of this study was to determine the within-session variability and between-session repeatability of spectral Fourier-domain optical coherence tomography (Doppler FD-OCT) Doppler retinal blood flow measurements in young and elderly subjects.
    Matched MeSH terms: Reproducibility of Results
  12. Lim R, Liong ML, Lau YK, Yuen KH
    Neurourol Urodyn, 2017 02;36(2):438-442.
    PMID: 26693962 DOI: 10.1002/nau.22950
    AIMS: To enable the use of the International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form (ICIQ-UI SF) and ICIQ-Lower Urinary Tract Symptoms Quality of Life (ICIQ-LUTSqol) in Southeast Asia, we translated and subsequently evaluated their validity (content and discriminant validity), reliability (internal consistency and test-retest reliability), and responsiveness in female patients with stress urinary incontinence.

    METHODS: Permission was obtained to translate the English versions into Malay and subsequently validate them, and to validate the existing Chinese versions. The translated questionnaires were taken for pilot testing. Validation was carried out for the face/content and discriminant validity. Reliability was assessed for test-retest and internal consistency using Cronbach's alpha and intraclass correlation coefficient respectively. The responsiveness was calculated via effect size and standardized response mean.

    RESULTS: Ten patients were recruited for the pilot testing. The English and Chinese versions had "substantial" or "almost perfect" agreement as measured by weighted Kappa. 284 participants (139 patients with stress urinary incontinence and 145 healthy volunteers) were included in the subsequent phases. The ICIQ-UI SF and ICIQ-LUTSqol had good discriminant validity. The ICIQ-UI SF had moderate internal consistency although the ICIQ-LUTSqol had good internal consistency. Both questionnaires had high test-retest reliability. Responsiveness was established with a moderate to large effect size and a standardized response mean.

    CONCLUSIONS: The English, Chinese, and Malay versions each proved to be valid and reliable in our Malaysian population, thereby enabling more cross-cultural research in this region. Neurourol. Neurourol. Urodynam. 36:438-442, 2017. © 2015 Wiley Periodicals, Inc.

    Matched MeSH terms: Reproducibility of Results
  13. Guan NC, Isa SM, Hashim AH, Pillai SK, Harbajan Singh MK
    Asia Pac J Public Health, 2015 Mar;27(2):NP2210-9.
    PMID: 22652253 DOI: 10.1177/1010539512447808
    The use of the Internet has been increasing dramatically over the decade in Malaysia. Excessive usage of the Internet has lead to a phenomenon called Internet addiction. There is a need for a reliable, valid, and simple-to-use scale to measure Internet addiction in the Malaysian population for clinical practice and research purposes. The aim of this study was to validate the Malay version of the Internet Addiction Test, using a sample of 162 medical students. The instrument displayed good internal consistency (Cronbach's α = .91), parallel reliability (intraclass coefficient = .88, P < .001), and concurrent validity with the Compulsive Internet Use Scale (Pearson's correlation = .84, P < .001). Receiver operating characteristic analysis showed that 43 was the optimal cutoff score to discriminate students with and without Internet dependence. Principal component analysis with varimax rotation identified a 5-factor model. The Malay version of the Internet Addiction Test appeared to be a valid instrument for assessing Internet addiction in Malaysian university students.
    Matched MeSH terms: Reproducibility of Results
  14. Shafie AA, Chhabra IK, Hui Yi JW, Mohammed NS, Ibrahim HM
    Value Health Reg Issues, 2021 May;24:47-56.
    PMID: 33508751 DOI: 10.1016/j.vhri.2020.08.003
    OBJECTIVE: The objective of this study was to examine the cross-sectional convergent and known-group validity of the Malay-language EQ-5D-3L instrument in children and adults with transfusion-dependent thalassemia (TDT).

    METHODS: A cross-sectional health-related quality of life survey involving TDT patients from 12 different treatment centers across Malaysia was conducted using the Malay PedsQL 4.0 Generic Core Scales and the Malay EQ-5D-3L questionnaire. Patients with non-TDT and other hemoglobinopathies were excluded. Convergent, discriminant, and known-group validity of the EQ-5D-3L was assessed against the PedsQL 4.0 Generic Core Scales in children. In the adult population, known-group validity of the EQ-5D-3L was assessed using an a priori hypothesis between patients' demographic characteristics and health outcomes obtained from literature.

    RESULTS: A total of 370 children and 225 adults were sampled. The mean (standard deviation) EQ-5D-3L scores of the children were 0.892 (0.082) and the adults were 0.887 (0.085). Convergent and discriminant validity was identified when correlated with the PedsQL domain in children. In both groups, known-group validity was evident when comparing groups of patients with reported problems to the group of patients with no reported problems on the EQ-5D-3L domains based on the a priori hypothesis derived from literature.

    CONCLUSION: This study found convergent, discriminant, and known-group validity of the Malay EQ-5D-3L in a population-based sample of patients with TDT. Hence, the instrument is valid for the assessment of health-related quality of life in children and adults with TDT in Malaysia.

    Matched MeSH terms: Reproducibility of Results
  15. Doss JG, Thomson WM, Drummond BK, Raja Latifah RJ
    Oral Oncol, 2011 Jul;47(7):648-52.
    PMID: 21602094 DOI: 10.1016/j.oraloncology.2011.04.023
    To assess the cross-sectional construct validity of the Malay-translated and cross-culturally adapted FACT-H&N (v 4.0) for discriminative use in a sample of Malaysian oral cancer patients. A cross-sectional study of adults newly diagnosed with oral cancer. HRQOL data were collected using the FACT-H&N (v 4.0), a global question and a supplementary set of eight questions ('MAQ') obtained earlier in pilot work. Of the 76 participants (61.8% female; 23.7% younger than 50), most (96.1%) had oral squamous cell carcinoma; two-thirds were in Stages III or IV. At baseline, patients' mean FACT summary (FACT-G, FACT-H&N, FACT-H&N TOI, and FHNSI) and subscale (pwb, swb, ewb, fwb, and hnsc) scores were towards the higher end of the range. Equal proportions (36.8%) rated their overall HRQOL as 'good' or 'average'; fewer than one-quarter rated it as 'poor', and only two as 'very good'. All six FACT summary and most subscales had moderate-to-good internal consistency. For all summary scales, those with 'very poor/poor' self-rated HRQOL differed significantly from the 'good/very good' group. All FACT summary scales correlated strongly (r>0.75). Summary scales showed convergent validity (r>0.90) but little discriminant validity. The discriminant validity of the FHNSI improved with the addition of the MAQ. The FACT-H&N summary scales and most subscales demonstrated acceptable cross-sectional construct validity, reliability and discriminative ability, and thus appear appropriate for further use among Malaysian oral cancer patients.
    Matched MeSH terms: Reproducibility of Results
  16. Kee CC, Lim KH, Sumarni MG, Teh CH, Chan YY, Nuur Hafizah MI, et al.
    BMC Med Res Methodol, 2017 Jun 02;17(1):85.
    PMID: 28577547 DOI: 10.1186/s12874-017-0362-0
    BACKGROUND: Self-reported weight and height are commonly used in lieu of direct measurements of weight and height in large epidemiological surveys due to inevitable constraints such as budget and human resource. However, the validity of self-reported weight and height, particularly among adolescents, needs to be verified as misreporting could lead to misclassification of body mass index and therefore overestimation or underestimation of the burden of BMI-related diseases. The objective of this study was to determine the validity of self-reported weight and height among Malaysian secondary school children.

    METHODS: Both self-reported and directly measured weight and height of a subgroup of 663 apparently healthy schoolchildren from the Malaysian Adolescent Health Risk Behaviour (MyAHRB) survey 2013/2014 were analysed. Respondents were required to report their current body weight and height via a self-administrative questionnaire before they were measured by investigators. The validity of self-reported against directly measured weight and height was examined using intraclass correlation coefficient (ICC), the Bland-Altman plot and weighted Kappa statistics.

    RESULTS: There was very good intraclass correlation between self-reported and directly measured weight [r = 0.96, 95% confidence interval (CI): 0.93, 0.97] and height (r = 0.94, 95% CI: 0.90, 0.96). In addition the Bland-Altman plots indicated that the mean difference between self-reported and direct measurement was relatively small. The mean difference (self-reported minus direct measurements) was, for boys: weight, -2.1 kg; height, -1.6 cm; BMI, -0.44 kg/m2 and girls: weight, -1.2 kg; height, -0.9 cm; BMI, -0.3 kg/m2. However, 95% limits of agreement were wide which indicated substantial discrepancies between self-reported and direct measurements method at the individual level. Nonetheless, the weighted Kappa statistics demonstrated a substantial agreement between BMI status categorised based on self-reported weight and height and the direct measurements (kappa = 0.76, 95% CI: 0.67, 0.84).

    CONCLUSION: Our results show that the self-reported weight and height were consistent with direct measurements and therefore can be used in assessing the nutritional status of Malaysian school children from the age of 13 to 17 years old in epidemiological studies and for surveillance purposes when direct measurements are not feasible, but not for assessing nutritional status at the individual level.
    Matched MeSH terms: Reproducibility of Results
  17. Reidpath DD, Cheah JC, Lam FC, Yasin S, Soyiri I, Allotey P
    Nutr J, 2013;12:135.
    PMID: 24093886 DOI: 10.1186/1475-2891-12-135
    BACKGROUND: Measures of central adiposity are better predictors of adverse health events than BMI. Nonetheless, BMI is more widely used in health research. One reason for this may be the limited research supporting the self-measurement of waist and hip circumference. The lack of validity studies is particularly acute in Asia. The main objective was to establish the validity of self-measurement of waist and hip circumference in a community setting and the correlation of those measures with BMI, blood pressure, and blood glucose levels.
    METHODS: A community based, cross-sectional survey. A "healthy living expo" at a shopping mall in a rural town on peninsular Malaysia One hundred and thirty six (136) individuals volunteered to participate in the study, 125 of whom met the inclusion criteria. The ethnic distribution of the participants was 80% Chinese, 17% Malay and 3% Indian. Most participants were female (60%), with participants' ages ranging from 18 to 78 years (mean, 47.2). Self and assisted measurements of waist and hip were taken. Blood pressure, non-fasting blood glucose, height, and weight were also measured. Bland Altman plots and Lin's concordance coefficient were used to measure agreement between self and assisted measures. Pearson's correlation was used to examine the association of self and assisted measures with blood pressure, blood glucose, and BMI.
    RESULTS: There was a downwards bias in self measured waist (-0.81 cm) and hip (-1 cm) circumferences compared with assisted measures. The concordance for the self and assisted measures of waist, hip and the ratio of the two were, respectively, .96, .93 , and .84. The correlation between measures of central adiposity and BMI, blood pressure and blood glucose were similar for self and assisted measures.
    CONCLUSION: The results provide additional support for the use of self-measurement of waist and hip circumference studies of central adiposity, but is limited by the specificity of the setting.
    Matched MeSH terms: Reproducibility of Results
  18. Abd Razak MA, Ahmad NA, Chan YY, Mohamad Kasim N, Yusof M, Abdul Ghani MKA, et al.
    Public Health, 2019 Apr;169:84-92.
    PMID: 30826688 DOI: 10.1016/j.puhe.2019.01.001
    OBJECTIVES: This systematic review aims to provide updated and comprehensive evidence on the validity and feasibility of screening tools for mild cognitive impairment (MCI) and dementia among the elderly at primary healthcare level.

    STUDY DESIGN: A review of articles was performed.

    METHODS: A search strategy was used by using electronic bibliographic databases including PubMed, Embase and CENTRAL for published studies and reference list of published studies. The articles were exported to a bibliographic database for further screening process. Two reviewers worked independently to screen results and extract data from the included studies. Any discrepancies were resolved and confirmed by the consensus of all authors.

    RESULTS: There were three screening approaches for detecting MCI and dementia - screening by a healthcare provider, screening by a self-administered questionnaire and caretaker informant screening. Montreal Cognitive Assessment (MoCA) was the most common and preferable tool for MCI screening (sensitivity [Sn]: 81-97%; specificity [Sp]: 60-86%), whereas Addenbrooke's Cognitive Examination (ACE) was the preferable tool for dementia screening (Sn: 79-100%; Sp: 86%).

    CONCLUSION: This systematic review found that there are three screening approaches for detecting early dementia and MCI at primary health care. ACE and MoCA are recommended tools for screening of dementia and MCI, respectively.

    Matched MeSH terms: Reproducibility of Results
  19. Deurenberg P, Deurenberg-Yap M
    Acta Diabetol, 2003 Oct;40 Suppl 1:S246-9.
    PMID: 14618484
    Most in vivo body composition methods rely on assumptions that may vary among different population groups as well as within the same population group. The assumptions are based on in vitro body composition (carcass) analyses. The majority of body composition studies were performed on Caucasians and much of the information on validity methods and assumptions were available only for this ethnic group. It is assumed that these assumptions are also valid for other ethnic groups. However, if apparent differences across ethnic groups in body composition 'constants' and body composition 'rules' are not taken into account, biased information on body composition will be the result. This in turn may lead to misclassification of obesity or underweight at an individual as well as a population level. There is a need for more cross-ethnic population studies on body composition. Those studies should be carried out carefully, with adequate methodology and standardization for the obtained information to be valuable.
    Matched MeSH terms: Reproducibility of Results
  20. Nor Aini J, Poh BK, Chee WS
    Pediatr Int, 2013 Apr;55(2):223-8.
    PMID: 23253297 DOI: 10.1111/ped.12035
    BACKGROUND: The aim of this cross-sectional study was to examine the ability of a children's physical activity questionnaire (cPAQ) to assess physical activity levels and bone health status of school children.
    METHODS: Subjects consisted of 90 pre-pubertal and early pubertal children aged 9-10 years. Components of physical activity were assessed using metabolic intensity (METPA) scores and mechanical bone strain (MECHPA) scores. An Actical accelerometer was used to validate METPA scores among a sub-sample of 57 children. Reliability was assessed by test-retesting all children after a 7 day interval. Whole body bone mineral content (BMC) was measured using dual-energy X-ray absorptiometry.
    RESULTS: The reliability of cPAQ for assessment of various categories of physical activity was moderate to high (r ranged from 0.55 to 0.68, P < 0.001). Agreement was fair for repeated use of the cPAQ (Cohen's kappa = 0.32, P < 0.001). Bland-Altman plots show cPAQ had fair agreement only for moderate activity (mean difference 35.4 min/week; 95% limits of agreement -434.0 to +504.9 min/week). Approximately 69.6% of children were correctly classified (into the same or adjacent quartiles) according to the quartiles of BMC for METPA score, and 58.7% were correctly classified according to MECHPA score. Only 10.9% and 12.0% of children were grossly misclassified as compared to METPA and MECHPA scores, respectively.
    CONCLUSIONS: The cPAQ has reasonable validity in assessing moderate physical activity, and it demonstrates good ability to accurately classify children according to BMC. It fails, however, to assess other activity levels, suggesting that objective measurement is still a better method of assessment of physical activity among primary school children.
    Matched MeSH terms: Reproducibility of Results
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links