Displaying publications 21 - 40 of 102 in total

Abstract:
Sort:
  1. Kamalden TA, Lingam G, Sundar G
    Ocul Oncol Pathol, 2014 Oct;1(1):13-8.
    PMID: 27175357 DOI: 10.1159/000363454
    Choroidal osteoma is a benign ossifying tumor of the choroid, consisting of mature bone tissue. It has been described to enlarge and evolve at varying rates over time. Here, we report and quantify the progression of a unilateral choroidal osteoma in a 7-year-old boy by fundus photography, and document tumor remodeling by spectral domain optical coherence tomography images.
    Matched MeSH terms: Tomography, Optical Coherence
  2. Nurul Ain, S., Norshamsiah, M.D., Safinaz, M.K., Bastion, M.L.C.
    Medicine & Health, 2018;13(1):232-236.
    MyJurnal
    Spontaneous closure of idiopathic full thickness macular hole is a rare case as it occurs in only 3.5% while awaiting vitrectomy surgery. There are few pathologies associated with it such as vitreomacular traction (VMT) and posterior vitreous detachment. We report a case in a 74-year-old man who presented with right eye painless, progressive blurring of vision with idiopathic stage 4 full thickness macular hole which was confirmed on optical coherence tomography. It closed spontaneously after sometimes while waiting for surgery. It is important to monitor closely for the possibility of spontaneous closure based on the optical coherence tomography findings.
    Matched MeSH terms: Tomography, Optical Coherence
  3. Sahak H, Saqalain M, Lott PW, McKibbin M
    Ophthalmologica, 2021;244(2):159-164.
    PMID: 33120391 DOI: 10.1159/000512636
    AIMS: To investigate the prevalence of sickle cell maculopathy (SCM), and associations with age, sex, genotype, proliferative sickle cell retinopathy (PSR) stage, and the impact on visual acuity.

    METHODS: Age, sex, and visual acuity were recorded and spectral domain OCT and ultra-wide-field images of the macula and retina were reviewed in a consecutive series of 74 adults with sickle cell disease.

    RESULTS: The median age was 37 years (range 19-73 years) and 36 cases (48.6%) were male. SCM was present in at least 1 eye of 40 cases (54.1%) or in 67 of all eyes (42.3%). SCM prevalence was 54.8%, 62.5%, and 25% for the HbSS, HbSC, and HbS/BThal or other genotypes, respectively. SCM was observed in 41 (39.4%) of the eyes with PSR stages 0, 1, and 2, and in 21 (51.2%) of the eyes with PSR stages 3, 4, and 5, respectively. Mild visual impairment or worse was present in 3 eyes (4.8%) with SCM but this was secondary to other pathology.

    CONCLUSION: SCM is a frequent finding in the eyes of adults with sickle cell disease. The prevalence is similar for the HbSS and HbSC genotypes and is not related to the PSR stage. High-contrast distance visual acuity is typically preserved.

    Matched MeSH terms: Tomography, Optical Coherence
  4. Sidibé D, Sankar S, Lemaître G, Rastgoo M, Massich J, Cheung CY, et al.
    Comput Methods Programs Biomed, 2017 Feb;139:109-117.
    PMID: 28187882 DOI: 10.1016/j.cmpb.2016.11.001
    This paper proposes a method for automatic classification of spectral domain OCT data for the identification of patients with retinal diseases such as Diabetic Macular Edema (DME). We address this issue as an anomaly detection problem and propose a method that not only allows the classification of the OCT volume, but also allows the identification of the individual diseased B-scans inside the volume. Our approach is based on modeling the appearance of normal OCT images with a Gaussian Mixture Model (GMM) and detecting abnormal OCT images as outliers. The classification of an OCT volume is based on the number of detected outliers. Experimental results with two different datasets show that the proposed method achieves a sensitivity and a specificity of 80% and 93% on the first dataset, and 100% and 80% on the second one. Moreover, the experiments show that the proposed method achieves better classification performance than other recently published works.
    Matched MeSH terms: Tomography, Optical Coherence
  5. Rahim RA, Thiam CK, Rahiman MH
    Sensors (Basel), 2008 Mar 27;8(4):2082-2103.
    PMID: 27879811
    The use of a personal computer together with a Data Acquisition System (DAQ) as the processing tool in optical tomography systems has been the norm ever since the beginning of process tomography. However, advancements in silicon fabrication technology allow nowadays the fabrication of powerful Digital Signal Processors (DSP) at a reasonable cost. This allows this technology to be used in an optical tomography system since data acquisition and processing can be performed within the DSP. Thus, the dependency on a personal computer and a DAQ to sample and process the external signals can be reduced or even eliminated. The DSP system was customized to control the data acquisition process of 16x16 optical sensor array, arranged in parallel beam projection. The data collected was used to reconstruct the cross sectional image of the pipeline conveyor. For image display purposes, the reconstructed image was sent to a personal computer via serial communication. This allows the use of a laptop to display the tomogram image besides performing any other offline analysis.
    Matched MeSH terms: Tomography, Optical
  6. Wong BS, Sharanjeet-Kaur S, Ngah NF, Sawri RR
    PMID: 32369922 DOI: 10.3390/ijerph17093154
    Hyperreflective dots (HRD) are activated retinal microglial cells induced by retinal inflammation in diabetic patients. This study was conducted to compare the HRD count of normal and diabetic subjects; to determine the correlation between hemoglobin A1c (HbA1c) levels and HRD count; to determine HbA1c cut-off levels for the appearance of HRD in diabetic patients. A cross-sectional study was conducted among normal and diabetic patients. Fundus photos, SD-OCT images and HbA1c levels were taken. A total of 25 normal subjects, 32 diabetics without retinopathy and 26 mild-to-moderate nonproliferative diabetic retinopathy (NPDR) diabetics were recruited. There was a statistically significant difference between the mean count of HRD among the normal group, the diabetic without retinopathy group and the mild-to-moderate NPRD group. The mean HRD count in the inner retina layer was significantly higher compared to the outer retina layer. There was a significant linear relationship between the HbA1c levels and HRD count. Using the receiver operating curve, the HbA1c level of 5.4% was chosen as the cut-off point for the appearance of HRD. The positive linear correlation between the HbA1c levels and the appearance of HRD may indicate that hyperglycemia could activate retina microglial cells in diabetic patients.
    Matched MeSH terms: Tomography, Optical Coherence
  7. Ngoo QZ, A NF, A B, Wh WH
    Korean J Ophthalmol, 2021 06;35(3):223-230.
    PMID: 34120421 DOI: 10.3341/kjo.2020.0019
    PURPOSE: To study the retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters in obstructive sleep apnoea (OSA) patients and their relationship with severity of the disease.

    METHODS: A cross-sectional, hospital-based study. Fifty-four OSA subjects and 54 controls were recruited. Candidate that fulfil the criteria with normal ocular examinations then proceed with spectrum domain Cirrus optical coherence tomography examinations. ONH parameters and RNFL thickness were evaluated. Apnoea-hypopnoea index (AHI) of the OSA group were obtained from the medical record.

    RESULTS: In OSA, mean of average RNFL thickness was 93.87 µm, standard deviation (SD) = 9.17, p = 0.008 (p < 0.05) while superior RNFL thickness was 113.59 µm, SD = 16.29, p ≤ 0.001 (p < 0.05). RNFL thickness fairly correlate with severity of the disease (AHI), superior RNFL with R = 0.293, R2 = 0.087, p = 0.030 (p < 0.05), and nasal RNFL R = 0.292, R2 = 0.085, p = 0.032. No significant difference and correlation observed on ONH parameters. In control group, mean of average RNFL thickness was 98.96 µm, SD = 10.50, p = 0.008 (p < 0.05) while superior RNFL thickness was 125.76 µm, SD = 14.93, p ≤ 0.001 (p < 0.05).

    CONCLUSIONS: The mean of the average and superior RNFL thickness were significantly lower in the OSA group compare to control. Regression analysis showed RNFL thickness having significantly linear relationship with the AHI, specifically involving the superior and nasal quadrant.

    Matched MeSH terms: Tomography, Optical Coherence
  8. Mohmad Z, Kah TA, Yong KC, Abdul Halim WH, Kong Yong T
    Clin Pract, 2011 Jul 01;1(3):e60.
    PMID: 24765321 DOI: 10.4081/cp.2011.e60
    The clinical features, autofluorescence, B-scan ultrasonography, optical coherence tomography and fluorescein angiography of the lesion were described. Multiple investigation modalities are needed to confirm the benign nature of the lesion. Careful evaluation and follow-up is crucial to avoid misdiagnosis and erroneous management.
    Matched MeSH terms: Tomography, Optical Coherence
  9. Ng DS, Ho M, Chen LJ, Yip FL, Teh WM, Zhou L, et al.
    Am J Ophthalmol, 2021 12;232:70-82.
    PMID: 34116008 DOI: 10.1016/j.ajo.2021.05.029
    PURPOSE: To assess the diagnostic accuracy of optical coherence tomography angiography (OCTA) compared with multimodal imaging for choroidal neovascularization (CNV) in central serous chorioretinopathy (CSC) eyes and to determine the features that predicted CNV.

    DESIGN: Prospective cross-sectional study.

    METHODS: Consecutive CSC patients were recruited from retina clinic. The reference standard for CNV was determined by interpretation of multimodal imaging with OCTA, structural OCT line scan, fluorescein angiography (FA), indocyanine green angiography (ICGA), ultra-widefield fundus photography and fundus autofluorescence (FAF). Two independent masked graders examined OCTA without FA and ICGA to diagnose CNV. Univariate and multivariate analyses were performed to evaluate factors associated with CNV.

    RESULTS: CNV was detected in 69 eyes in 64 out of 277 CSC patients according to reference standard. The two masked graders who examined OCTA had sensitivity of 81.2% (95% Confidence Interval [CI], 71.9%-90.4%) and 78.3% (95% CI, 68.5%-88.0%), specificity of 97.3% (95% CI, 95.9%-98.8%) and 96.2% (95% CI, 94.5%-98.0%), positive predictive values of 82.4% (95% CI, 73.3%-91.4%) and 76.1% (95% CI, 66.1%-86.0%), and negative predictive values of 97.1% (95% CI, 95.6%-98.7%) and 96.7% (95% CI, 95.0%-98.3%). Their mean area under the receiver operating characteristic curve (AUC) was 0.88 with good agreement (Kappa coefficient 0.80 [95% CI, 0.72-0.89]). Flat irregular pigment epithelial detachment on structural OCT, neovascular network on OCTA and ill-defined late leakage on FA significantly correlated with CNV in CSC from multiple regression (P < 0.001, P < 0.001 and P = 0.005, respectively).

    CONCLUSIONS: There is discordance between OCTA and multimodal imaging in diagnosing CNV in CSC. This study demonstrated the caveats in OCTA interpretation, such as small extrafoveal lesions and retinal pigment epithelial alterations. Comprehensive interpretation of OCTA with dye angiography and structural OCT is recommended.

    Matched MeSH terms: Tomography, Optical Coherence
  10. Weller JM, Bergua A, Mardin CY
    Retin Cases Brief Rep, 2015;9(1):72-7.
    PMID: 25383851 DOI: 10.1097/ICB.0000000000000087
    To describe the clinical findings, diagnostics, and differential diagnosis in a patient with retinopathy in acute systemic Epstein-Barr virus (EBV) infection.
    Matched MeSH terms: Tomography, Optical Coherence/methods
  11. Bastion ML
    BMJ Case Rep, 2010;2010.
    PMID: 22791576 DOI: 10.1136/bcr.03.2010.2867
    To describe an unusual case of vitreomacular traction syndrome spontaneously resolving prior to elective pars planar vitrectomy demonstrated on optical coherence tomography.
    Matched MeSH terms: Tomography, Optical Coherence*
  12. Abdul Rahim R, Pang JF, Chan KS, Leong LC, Sulaiman S, Abdul Manaf MS
    ISA Trans, 2007 Apr;46(2):131-45.
    PMID: 17367791
    The data distribution system of this project is divided into two types, which are a Two-PC Image Reconstruction System and a Two-PC Velocity Measurement System. Each data distribution system is investigated to see whether the results' refreshing rate of the corresponding measurement can be greater than the rate obtained by using a single computer in the same measurement system for each application. Each system has its own flow control protocol for controlling how data is distributed within the system in order to speed up the data processing time. This can be done if two PCs work in parallel. The challenge of this project is to define the data flow process and critical timing during data packaging, transferring and extracting in between PCs. If a single computer is used as a data processing unit, a longer time is needed to produce a measurement result. This insufficient real-time result will cause problems in a feedback control process when applying the system in industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit.
    Matched MeSH terms: Tomography, Optical/methods*
  13. Lim CW, Cheng J, Tay ELT, Teo HY, Wong EPY, Yong VKY, et al.
    BMC Ophthalmol, 2018 Dec 10;18(1):315.
    PMID: 30526537 DOI: 10.1186/s12886-018-0976-y
    BACKGROUND: Despite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements.

    METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability.

    RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%.

    CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system.

    TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.

    Matched MeSH terms: Tomography, Optical Coherence/methods
  14. Raghavendra U, Gudigar A, Bhandary SV, Rao TN, Ciaccio EJ, Acharya UR
    J Med Syst, 2019 Jul 30;43(9):299.
    PMID: 31359230 DOI: 10.1007/s10916-019-1427-x
    Glaucoma is a type of eye condition which may result in partial or consummate vision loss. Higher intraocular pressure is the leading cause for this condition. Screening for glaucoma and early detection can avert vision loss. Computer aided diagnosis (CAD) is an automated process with the potential to identify glaucoma early through quantitative analysis of digital fundus images. Preparing an effective model for CAD requires a large database. This study presents a CAD tool for the precise detection of glaucoma using a machine learning approach. An autoencoder is trained to determine effective and important features from fundus images. These features are used to develop classes of glaucoma for testing. The method achieved an F - measure value of 0.95 utilizing 1426 digital fundus images (589 control and 837 glaucoma). The efficacy of the system is evident, and is suggestive of its possible utility as an additional tool for verification of clinical decisions.
    Matched MeSH terms: Tomography, Optical Coherence/methods*
  15. Ghoshal R, Sharanjeet-Kaur S, Fadzil NM, Ghosh S, Ngah N, Aziz RAA
    PMID: 34070071 DOI: 10.3390/ijerph18105378
    Although optical coherence tomography (OCT) parameters have assisted in the diagnosis of polypoidal choroidal vasculopathy (PCV), its potential to evaluate treatment outcomes has not been established. The purpose of this pilot study was to evaluate baseline OCT parameters that may influence treatment outcome in PCV eyes with combination therapy. In this single-centered, prospective study, patients were recruited with at least one treatment-naïve PCV eye and treated with combination therapy of intravitreal anti-vascular endothelial growth factor and photodynamic therapy. Best-corrected distance and near visual acuity (DVA and NVA), and contrast sensitivity (CS) were recorded at baseline and six months after treatment. OCT parameters were determined. Twenty-six eyes of 26 patients aged between 51 to 83 years were evaluated. In eyes that had disrupted external limiting membrane (ELM), photoreceptors inner and outer segment (IS-OS) junction at 1000 micron of fovea at baseline showed low mean visual functions after 6 months of treatment. Eyes with foveal sub-retinal fluid (SRF) and polyp at central 1000 micron of fovea at baseline showed significantly worse DVA and CS after six months. Thus, the presence of foveal SRF, foveal polyp, disrupted ELM, and IS-OS junction at baseline significantly influenced the six months' visual outcome in PCV eyes treated with combination therapy.
    Matched MeSH terms: Tomography, Optical Coherence*
  16. Othman SF, Sharanjeet-Kaur, Manan FA, Zulkarnain AI, Mohamad Z, Ariffin AE
    Clin Exp Optom, 2012 Sep;95(5):484-91.
    PMID: 22716100 DOI: 10.1111/j.1444-0938.2012.00752.x
    PURPOSE:This study aimed to determine the relationship between macular thickness and spherical equivalent refraction (SER), axial length (AL) and vitreous chamber depth (VCD) in Malay subjects.
    METHODS: Sixty-three subjects (aged 19-24 years) with a mean SER of -1.79 ± 2.24 D, mean axial length of 24.26 ± 1.35 mm and mean vitreous chamber depth of 17.02 ± 1.33 mm were included in this clinical cross-sectional study. Stratus optical coherence tomography (Time Domain optical coherence tomography) was used to determine the thickness of the outer macular (perifovea) and inner macular (parafovea) at four different locations, that is, temporal, superior, nasal and inferior quadrants and also the fovea itself.
    RESULTS: Positive correlations were found between the outer macular (perifovea) thickness and SER at the temporal (R = 0.47, p < 0.05), superior (R = 0.36, p < 0.05) and inferior (R = 0.31, p < 0.05) quadrants. Foveal thickness was also positively correlated with AL (R = 0.34, p < 0.05) and VCD (R = 0.32, p < 0.05). Negative correlations were found between outer macular thickness and axial length at the temporal (R = -0.46, p < 0.05), superior (R = -0.27, p < 0.05), nasal (R = -0.25, p < 0.05) and inferior (R = -0.36, p < 0.05) quadrants. Negative correlations were also found between outer macular thickness and VCD at the temporal (R = -0.51, p < 0.05), superior (R = -0.32, p < 0.05), nasal (R = -0.31, p < 0.05) and inferior (R = -0.40, p < 0.05) quadrants.
    CONCLUSIONS: This study shows that the degree of myopia and elongation of the globe are associated with thinning of most areas of the perifovea. A trend for foveal thickening in the high myopia group is also inferred, although this does not apply to the low and moderate myopia groups.
    Study site: Optometry and ophthalmology clinics, National Institute of Ophthalmic Sciences, Tun Hussein Onn National Eye Hospital (THONEH), Petaling Jaya
    Matched MeSH terms: Tomography, Optical Coherence/methods*
  17. Koay CL, Quo MJ, Subrayan V
    Int Ophthalmol, 2017 Jun;37(3):655-671.
    PMID: 27558260 DOI: 10.1007/s10792-016-0306-4
    The purpose of this study was to investigate the reproducibility of choroidal thickness measurements in normal subjects on 3 spectral domain optical coherence tomography instruments, namely: Zeiss Cirrus HD-OCT (Carl Zeiss Meditec Inc., Dublin, CA), Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany), and Optovue RTVue (Optovue Inc., Fremont, CA). This cross-sectional non-interventional study was performed in a single institution. Images were obtained in 47 eyes of 47 healthy volunteers which age ranged between 23 and 72 without ocular pathology. All subjects were imaged on the fovea using Cirrus HD 1-line raster, Spectralis enhanced depth imaging, and RTVue retina-cross. The choroid was measured subfoveally and at intervals of 500 µm from the fovea nasally and temporally up to 2500 µm. Paired t test, modified Bland-Altman plot, and Pearson's correlation were used to compare the results. There is no significant difference between the systems for any measurement within 2500 µm either side of the fovea for most points. Inter-observer correlation was strong for RTVue, and moderate in both Cirrus and Spectralis.
    Matched MeSH terms: Tomography, Optical Coherence/instrumentation*
  18. Chen KJ, Chou HD, Teh WM
    Ophthalmol Retina, 2019 10;3(10):887.
    PMID: 31585711 DOI: 10.1016/j.oret.2019.05.023
    Matched MeSH terms: Tomography, Optical Coherence/methods*
  19. Ling KP, Mangalesh S, Tran-Viet D, Gunther R, Toth CA, Vajzovic L
    Retina, 2020 Oct;40(10):1996-2003.
    PMID: 31764609 DOI: 10.1097/IAE.0000000000002688
    BACKGROUND/PURPOSE: Using handheld spectral domain optical coherence tomography (SDOCT) imaging to investigate in vivo microanatomic retinal changes and their progression over time in young children with juvenile X-linked retinoschisis (XLRS).

    METHODS: This retrospective analysis was of handheld SD OCT images obtained under a prospective research protocol in children who had established XLRS diagnosis based on genetic testing or clinical history. Three OCT graders performed standardized qualitative and quantitative assessment of retinal volume scans, which were divided into foveal, parafoveal, and extrafoveal regions. Visual acuity data were obtained when possible.

    RESULTS: Spectral domain OCT images were available of both eyes in 8 pediatric patients with ages 7 months to 10 years. The schisis cavities involved inner nuclear layer in over 90% (15/16) of eyes in all 3 regions. Retinal nerve fiber and ganglion cell layer involvement was present only in the extrafoveal region in 63% (10/16) eyes and outer nuclear and plexiform layer in few others. In 7 children followed over 2 months to 15 months, the location of schisis remained consistent. Central foveal thickness decreased from the baseline to final available visit in 4/6 eyes. Ellipsoid zone disruption seemed to accompany lower visual acuity in 1/4 eyes.

    CONCLUSION: Early in life, the SD OCT findings in XLRS demonstrate differences in schisis location in fovea-parafoveal versus extrafoveal region, possible association between poor visual acuity and degree of ellipsoid zone disruption and decrease in central foveal thickness over time in this group. Furthermore, they illustrates that the pattern of XLRS in adults is already present in very young children, and unlike in older children and adults, those presenting with earlier disease may have a more aggressive course. Further studies in this early age group may provide more insights into treatment and prevention of progressive visual impairment in children with XLRS.

    Matched MeSH terms: Tomography, Optical Coherence*
  20. Zain E, Zakian CM, Chew HP
    J Dent, 2018 04;71:31-37.
    PMID: 29378225 DOI: 10.1016/j.jdent.2018.01.009
    OBJECTIVE: The main objective of this study was to evaluate the accuracy of optical coherence tomography (OCT) in detecting naturally occurring non-cavitated fissure caries (NCFC) in totality and at different loci by visually assessing cross-sectional OCT scans (B-scan) with an interpretation criterion. The secondary objective was to evaluate the agreement between dimensions of NCFC measured with OCT and polarized light microscopy (PLM).

    METHODS: 71 investigation sites of sound fissure and naturally occurring NCFC on human extracted premolars were identified and scanned with a swept-source OCT. The teeth were then sectioned bucco-lingually at the investigation sites and imaged using PLM. Two calibrated examiners trained on the B-scan NCFC visual interpretation criteria established for this study, assessed the investigation sites and results were validated against PLM.

    RESULTS: Detection sensitivity of B-scan for NCFC when fissures were assessed in totality, or on the slopes or walls separately are 0.98, 0.95, 0.94 and specificity are 0.95, 0.90, and 0.95. One-way ANOVA showed that width measurements of wall loci done with OCT and PLM were not statistically different. However, OCT height measurements of slope loci were statistically bigger with a constant bias of 0.08 mm (of which is not clinically significant) and OCT height measurements of wall loci were statistically smaller (0.57 mm) and Bland-Altman plots indicated presence of proportionate bias.

    CONCLUSION: Visual assessment of B-scans with the interpretation criteria resulted in both high specificity and sensitivity and were not affected by loci location. OCT width measurement of wall loci is in agreement with PLM.

    CLINICAL SIGNIFICANCE: Unanimous high sensitivity in this and previous studies indicate that visual assessment of B-scans reliably rule out NCFC. Detection accuracy was not affected by loci location. Width of wall loci and/or height of slope loci in OCT B-scan are to be used for monitoring NCFC but not height of wall loci.

    Matched MeSH terms: Tomography, Optical Coherence/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links