  1. Chainchel Singh MK, Abdul Rashid SN, Abdul Hamid S, Mahmood MS, Feng SS, Mohd Nawawi H, et al.
    Forensic Sci Int, 2020 Mar;308:110171.
    PMID: 32032870 DOI: 10.1016/j.forsciint.2020.110171
    BACKGROUND: Post-mortem Computed Tomography (PMCT) allows non-invasive or minimally invasive detection of findings that may or may not be visible during conventional autopsy, however, it does not allow the investigator to draw any conclusions regarding patency of the vessel's lumen. To address this deficiency, Post-mortem Computed Tomography Angiography (PMCTA) utilizing different contrast media and techniques have been introduced with various studies looking at the correlation between PMCTA, autopsy (gross) findings and coronary artery histology in diagnosing coronary artery disease.

    OBJECTIVES: The aim of this study is to investigate the sensitivity and specificity of PMCTA in diagnosing coronary artery stenosis using water-based contrast media introduced though the vessels of the neck, compared to the gold standard of diagnosis i.e. gross and histological evaluation of the coronary artery.

    METHOD: This was a cross sectional study of 158 arterial sections involving 37 subjects recruited from the National Institute of Forensic Medicine (IPFN), Hospital Kuala Lumpur (HKL). An unenhanced PMCT was performed followed by PMCTA using water-based contrast media introduced though the vessels of the neck. Coronary artery stenosis was determined using multiplanar reconstructionD while the degree of stenosis was determined by calculating the percentage of luminal diameter divided by the diameter of the vessel internal elastic.

    RESULTS: The analysis of PMCTA and histopathology examinations revealed a sensitivity of 61.5%, specificity of 91.7%; positive predictive value (PPV) of 40.0% and negative predictive value (NPV) of 96.4%.

    CONCLUSION: PMCTA utilizing water-based contrast introduced though the vessels of the neck yielded similar results as other methods and techniques of PMCTA. We would therefore conclude that PMCTA utilizing this technique could be used to assess the degree of calcification and the presence of significant stenosis.

    Matched MeSH terms: Computed Tomography Angiography/methods*
  2. Harun HH, Karim MKA, Abbas Z, Sabarudin A, Muniandy SC, Ibahim MJ
    J Xray Sci Technol, 2020;28(5):893-903.
    PMID: 32741801 DOI: 10.3233/XST-200699
    PURPOSE: To evaluate the influence of iterative reconstruction (IR) levels on Computed Tomography (CT) image quality and to establish Figure of Merit (FOM) value for CT Pulmonary Angiography (CTPA) examinations.

    METHODS: Images of 31 adult patients who underwent CTPA examinations in our institution from March to April 2019 were retrospectively collected. Other data, such as scanning parameters, radiation dose and body habitus information from the subjects were also recorded. Six different levels of IR were applied to the volume data of the subjects. Five circles of the region of interest (ROI) were drawn in five different arteries namely, pulmonary trunk, right pulmonary artery, left pulmonary artery, ascending aorta and descending aorta. The mean Signal-to-noise ratio (SNR) was obtained, and the FOM was calculated in a fraction of the SNR2 divided by volume-weighted CT dose index (CTDIvol) and SNR2 divided by the size-specific dose estimates (SSDE).

    RESULTS: Overall, we observed that the mean value of CTDIvol and SSDE were 13.79±7.72 mGy and 17.25±8.92 mGy, respectively. Notably, SNR values significantly increase with increase of the IR level (p 

    Matched MeSH terms: Computed Tomography Angiography/methods*
  3. Liew YH, Ong SCL, Balasingam V
    BMJ Case Rep, 2017 Nov 14;2017.
    PMID: 29141933 DOI: 10.1136/bcr-2017-222821
    Matched MeSH terms: Computed Tomography Angiography*
  4. Baradaran H, Ng CR, Gupta A, Noor NM, Al-Dasuqi KW, Mtui EE, et al.
    Int Angiol, 2017 Oct;36(5):445-461.
    PMID: 28541017 DOI: 10.23736/S0392-9590.17.03811-1
    BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of calcium in the CT slices, it is therefore necessary to identify these slices before the corrected volume can be estimated.

    METHODS: The system typically consists of segmenting the calcium region from the CT scan into slices based on Hounsfield Unit-based threshold, and subsequently computing the summation of the calcium areas in each slice. However, when the carotid volume has intermittently higher concentration of contrast agent, a dependable approach is adapted to correct the calcium region using the neighboring slices, thereby estimating the correct volume. Furthermore, mitigation is provided following the regulatory constraints by changing the system to semi-automated criteria as a fall back solution. We evaluate the automated and semi-automated techniques using completely manual calcium volumes computed based on the manual tracings by the neuroradiologist.

    RESULTS: A total of 64 patients with calcified plaque in the internal carotid artery were analyzed. Using the above algorithm, our automated and semi-automated system yields correlation coefficients (CC) of 0.89 and 0.96 against first manual readings and 0.90 and 0.96 against second manual readings, respectively. Using the t-test, there was no significant difference between the automated and semi-automated methods against manual. The intra-observer reliability was excellent with CC 0.98.

    CONCLUSIONS: Compared to automated method, the semi-automated method for calcium volume is acceptable and closer to manual strategy for calcium volume. Further work evaluating and confirming the performance of our semi-automated protocol is now warranted.

    Matched MeSH terms: Computed Tomography Angiography*
  5. Borhanuddin BK, Abdul Latiff H, Mohamed Yusof AK
    Cardiol Young, 2022 Dec;32(12):1994-1998.
    PMID: 35707919 DOI: 10.1017/S1047951122000154
    BACKGROUND: CT is an accepted non-invasive imaging tool to assess the coronary arteries in adults; however, its utilisation in children is limited by high heart rate and lack of standardised protocol. We sought to assess diagnostic quality and factors that affect image quality of CT in assessing coronary artery lesions in Kawasaki patients less than 18 years of age.

    METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.

    RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).

    CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.

    Matched MeSH terms: Computed Tomography Angiography/methods
  6. Abdullah KA, McEntee MF, Reed W, Kench PL
    J Med Radiat Sci, 2020 Sep;67(3):170-176.
    PMID: 32219989 DOI: 10.1002/jmrs.387
    INTRODUCTION: 3D-printed imaging phantoms are now increasingly available and used for computed tomography (CT) dose optimisation study and image quality analysis. The aim of this study was to evaluate the integrated 3D-printed cardiac insert phantom when evaluating iterative reconstruction (IR) algorithm in coronary CT angiography (CCTA) protocols.

    METHODS: The 3D-printed cardiac insert phantom was positioned into a chest phantom and scanned with a 16-slice CT scanner. Acquisitions were performed with CCTA protocols using 120 kVp at four different tube currents, 300, 200, 100 and 50 mA (protocols A, B, C and D, respectively). The image data sets were reconstructed with a filtered back projection (FBP) and three different IR algorithm strengths. The image quality metrics of image noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were calculated for each protocol.

    RESULTS: Decrease in dose levels has significantly increased the image noise, compared to FBP of protocol A (P 

    Matched MeSH terms: Computed Tomography Angiography*
  7. Dk Yeak R, Liew SK
    Acta Orthop Traumatol Turc, 2020 Jul;54(4):465-468.
    PMID: 32812879 DOI: 10.5152/j.aott.2020.20035
    We present a rare case of a patient with concurrent fat embolism and pulmonary embolism, in a closed femur fracture with patent foramen ovale (PFO). A 24-year-old man was involved in a motor vehicle accident with a closed left midshaft femur fracture. He developed fat embolism syndrome (FES) on day 3 of admission, and plating was performed. The D-dimer concentration was also high, which raised the suspicion of pulmonary artery embolism. Computed tomography pulmonary angiography (CTPA) revealed right inferior lobar pulmonary artery embolism and FES. A transthoracic echocardiogram (TEE) was performed, which showed a PFO. The presence of a PFO in patients with pulmonary embolism increases the risk of systemic embolism. Therefore, we recommend the routine echocardiogram for patients with pulmonary embolism to exclude any cardiac defect in causing right-to-left shunts, which predisposes the patient to paradoxical embolism.
    Matched MeSH terms: Computed Tomography Angiography/methods
  8. Sakai K, Storozhenko T, Mizukami T, Ohashi H, Bouisset F, Tajima A, et al.
    Catheter Cardiovasc Interv, 2024 May;103(6):885-896.
    PMID: 38566527 DOI: 10.1002/ccd.31020
    BACKGROUND: Two invasive methods are available to estimate microvascular resistance: bolus and continuous thermodilution. Comparative studies have revealed a lack of concordance between measurements of microvascular resistance obtained through these techniques.

    AIMS: This study aimed to examine the influence of vessel volume on bolus thermodilution measurements.

    METHODS: We prospectively included patients with angina with non-obstructive coronary arteries (ANOCA) undergoing bolus and continuous thermodilution assessments. All patients underwent coronary CT angiography to extract vessel volume. Coronary microvascular dysfunction was defined as coronary flow reserve (CFR) 

    Matched MeSH terms: Computed Tomography Angiography*
  9. Alkhorayef M, Sulieman A, Alzahrani K, Abuzaid M, Alomair OI, Almuwannis M, et al.
    Appl Radiat Isot, 2021 Feb;168:109520.
    PMID: 33307438 DOI: 10.1016/j.apradiso.2020.109520
    The various technological advancements in computed tomography (CT) have resulted in remarkable growth in the use of CT imaging in clinical practice, not the least of which has been its establishment as the most valuable imaging examination for the assessment of cardiovascular system disorders. The objective of this study was to assess the effective radiation dose and radiation risk for patients during cardiac CT procedures, based on studies from four different hospitals equipped with 128 slice CT equipment. A total of eighty-three patients were investigated in this study with different clinical indications. Effective doses were also calculated using software based on Monte Carlo simulation. The mean patient age (years), weight (kg), and body mass index (BMI (kg/m2)) were 49 ± 11, 82 ± 12, and 31 ± 6, respectively. The results of the study revealed that the tube voltage (kVp) and tube current-exposure time product (mAs) ranged between 100 to 140 and 50 to 840 respectively. The overall average patient dose values for the volume CT dose index [(CTDIvol), in mGy)] and dose length product (DLP) (in mGy·cm) were 34.8 ± 15 (3.7-117.0) and 383.8 ± 354 (46.0-3277.0) respectively. The average effective dose (mSv) was 15.2 ± 8 (1.2-61.8). The radiation dose values showed wide variation between different hospitals and even within the same hospital. The results indicate the need to optimize radiation dose and to establish diagnostic reference levels (DRLs) for patients undergoing coronary computed tomography angiography (CCTA), also to harmonize the imaging protocols to ensure reduced radiation risk.
    Matched MeSH terms: Computed Tomography Angiography
  10. Harun HH, Abdul Karim MK, Abd Rahman MA, Abdul Razak HR, Che Isa IN, Harun F
    Diagnostics (Basel), 2020 Sep 09;10(9).
    PMID: 32916913 DOI: 10.3390/diagnostics10090680
    This study aimed to establish the local diagnostic reference levels (LDRLs) of computed tomography pulmonary angiography (CTPA) examinations based on body size with regard to noise magnitude as a quality indicator. The records of 127 patients (55 males and 72 females) who had undergone CTPAs using a 128-slice CT scanner were retrieved. The dose information, scanning acquisition parameters, and patient demographics were recorded in standardized forms. The body size of patients was categorized into three groups based on their anteroposterior body length: P1 (14-19 cm), P2 (19-24 cm), and P3 (24-31 cm), and the radiation dose exposure was statistically compared. The image noise was determined quantitatively by measuring the standard deviation of the region of interest (ROI) at five different arteries-the ascending and descending aorta, pulmonary trunk, and the left and right main pulmonary arteries. We observed that the LDRL values were significantly different between body sizes (p < 0.05), and the median values of the CT dose index volume (CTDIvol) for P1, P2, and P3 were 6.13, 8.3, and 21.40 mGy, respectively. It was noted that the noise reference values were 23.78, 24.26, and 23.97 HU for P1, P2, and P3, respectively, which were not significantly different from each other (p > 0.05). The CTDIvol of 9 mGy and dose length product (DLP) of 329 mGy∙cm in this study were lower than those reported by other studies conducted elsewhere. This study successfully established the LDRLs of a local healthcare institution with the inclusion of the noise magnitude, which is comparable with other established references.
    Matched MeSH terms: Computed Tomography Angiography
  11. Noorlaila B., Zunaina E., Raja Norliza R.O., Nor Fadzillah A.J., Alice, G.K.C.
    MyJurnal
    We report a case of dural carotid cavernous fistula (CCF) pose a diagnostic dilemma with initial symptoms of the arteriovenous shunt. A 56 year-old man presented with right eye diplopia, thensubsequently developed ptosis, congestion of conjunctiva, dilated episcleral vessels, and gradual rise in intraocular pressure. Initial diagnosis of pseudotumour was made based on negative finding of CCF by computed tomography angiography (CTA). In view of persistent clinical manifestations in spite of steroid therapy, and with the presence of new ocular signs; cock-screw conjunctival vessels, dilated retinal veins, and proptosis, digital subtraction angiography (DSA) was performed and confirmed the diagnosis of dural CCF.The ocular symptoms resolved completely post embolization of the fistula.
    Matched MeSH terms: Computed Tomography Angiography
  12. Shahril Shamsul, Akmal Sabarudin, Hamzaini Abdul Hamid, Norzailin Abu Bakar, Oteh Maskon, Muhammad Khalis Abdul Karim
    MyJurnal
    The purpose of this study was to evaluate the image quality and diagnostic accuracy of coronary computed tomography angiography (CCTA) using 640-slice scanner. Advancement of multidetector computed tomography (MDCT) technology with higher spatial, temporal resolution, and increasing detector array have improved the image quality and diagnostic accuracy of CCTA. A total of 25 patients (12 men and 13 women) underwent CCTA examination was chosen and data was acquired by 640-slice scanner. All 16 segments of coronary arteries were evaluated by two reviewers using a 4-likert scale for qualitative assessment. In quantitative assessment, the evaluation of 4 main coronary arteries were analysed in terms of signal intensity (SI), image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). All 25 patients with a mean age of 52.88 ± 14.75 years old and body mass index (BMI) of 24.24 ± 3.28 kg/m2 were analysed. In qualitative assessment, from the total of 400 segments, 379 segments (95%) had diagnostic value while 21 segments did not have diagnostic value, which means 5% artefact was detected. In quantitative assessment, there was no statistical differences in gender, race, and BMI (p>0.05). Overall evaluation showed that higher SI at the left main artery (LM) at 393.7 ± 47.19. Image noise was higher at right coronary artery (RCA) at 39.01 ± 13.97. SNR and CNR showed higher at left anterior descending (LAD) with 12.73 ± 5.17 and LM 9.14 ± 4.2, respectively. In conclusion, this study indicates that 640-slice MDCT has higher diagnostic value in CCTA examination with 95% vessel visibility with 5% artefact detection.
    Matched MeSH terms: Computed Tomography Angiography
  13. Sabarudin A, Subramaniam C, Sun Z
    Quant Imaging Med Surg, 2014 Aug;4(4):282-90.
    PMID: 25202664 DOI: 10.3978/j.issn.2223-4292.2014.07.10
    The purpose of this study was to analyse the diagnostic value of cerebral CT angiography (CTA) and CT perfusion (CTP) examinations in the detection of acute stroke based on a systematic review of the current literature. The review was conducted based on searching of seven databases for articles published between 1993 and 2013. Diagnostic value in terms of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy was analysed from 21 articles which were found to meet selection criteria. The mean sensitivity, specificity, PPV, NPV and accuracy for CTA were significantly higher than those for CTP with 83.2% (95% CI: 57.9-100.0%), 95.0% (95% CI: 74.4-100%), 84.1% (95% CI: 50.0-100%), 97.1 (95% CI: 94.0-100%) and 94.0% (95% CI: 83.0-99.0) versus 69.9% (95% CI: 20.0-97.0%), 87.4 (95% CI: 61.0-100.0%), 76.4% (95% CI: 48.0-95.4%), 78.2% (95% CI: 55.8-93.9%) and 89.8% (95% CI: 75.7-97.1%), respectively. This analysis shows that CTA has high diagnostic value in detecting high degree of cerebral arterial stenosis (>70%) whereas CTP provides high specificity in the detection of ischemia and infarct tissue of brain.
    Matched MeSH terms: Computed Tomography Angiography
  14. Chian TC, Nassir NM, Ibrahim MI, Yusof AK, Sabarudin A
    Quant Imaging Med Surg, 2017 Feb;7(1):48-58.
    PMID: 28275559 DOI: 10.21037/qims.2017.02.02
    BACKGROUND: This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols.

    METHODS: Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software.

    RESULTS: Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp.

    CONCLUSIONS: There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.

    Matched MeSH terms: Computed Tomography Angiography
  15. Tan SK, Ng KH, Yeong CH, Raja Aman RRA, Mohamed Sani F, Abdul Aziz YF, et al.
    Quant Imaging Med Surg, 2019 Apr;9(4):552-564.
    PMID: 31143647 DOI: 10.21037/qims.2019.03.13
    Background: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol.

    Methods: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.

    Results: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).

    Conclusions: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

    Matched MeSH terms: Computed Tomography Angiography
  16. Tunku-Naziha TZ, Wan-Yuhana W, Hadizie D, Muhammad-Paiman, Abdul-Nawfar S, Wan-Azman WS, et al.
    Malays Orthop J, 2017 Mar;11(1):12-17.
    PMID: 28435568 MyJurnal DOI: 10.5704/MOJ.1703.005
    The management of pink pulseless limbs in supracondylar fractures has remained controversial, especially with regards to the indication for exploration in a clinically well-perfused hand. We reviewed a series of seven patients who underwent surgical exploration of the brachial artery following supracondylar fracture. All patients had a non-palpable radial artery, which was confirmed by Doppler ultrasound. CT angiography revealed complete blockage of the artery with good collateral and distal run-off. Two patients were more complicated with peripheral nerve injuries, one median nerve and one ulnar nerve. Only one patient had persistent arterial constriction which required reverse saphenous graft. The brachial arteries were found to be compressed by fracture fragments, but were in continuity. The vessels were patent after the release of obstruction and the stabilization of the fracture. There was no transection of major nerves. The radial pulse was persistently present after 12 weeks, and the nerve activity returned to full function.
    Matched MeSH terms: Computed Tomography Angiography
  17. Chan PL, Tan FHS
    Clin Hypertens, 2018;24:15.
    PMID: 30410790 DOI: 10.1186/s40885-018-0100-x
    Background: Hypokalemia in the presence of hypertension is often attributed to primary hyperaldosteronism as a cause of secondary hypertension, however secondary hyperaldosteronism may present similarly. Accessory renal arteries are variants in the vascular anatomy which are often thought to be innocuous but in some circumstances can cause renovascular hypertension leading to secondary hyperaldosteronism.

    Case presentation: We report 2 cases of hypertension with secondary hyperaldosteronism associated with accessory renal arteries. Both patients presented with hypokalemia and further investigations revealed hyperaldosteronism with unsuppressed renin levels. Imaging studies showed the presence of accessory renal artery.

    Conclusion: Accessory renal arteries are a potential cause renovascular hypertension which can be detected via CT angiography or magnetic resonance angiography. Hormonal evaluation should be undertaken to determine whether its presence contributes to hypertension in the patient as targeted treatment such as aldosterone antagonist can be initiated. Surgical intervention or renal denervation may be considered in resistant cases.

    Matched MeSH terms: Computed Tomography Angiography
  18. Anwar A, Chan KMJ, Awang Y, Ping DC
    Med J Malaysia, 2019 Oct;74(5):436-438.
    PMID: 31649223
    Anomalous Aortic Origin of a Coronary Artery (AAOCA) is a rare anomaly of the coronary artery with a considerable risk of sudden cardiac death due to ischaemia of the heart. Symptoms may include chest pain on exertion, breathlessness or dizziness. We encountered a case of a 46- year-old female who complained of exertional chest pain with a positive-stress test and subsequently diagnosed with AAOCA through CT angiography (CTA). She successfully underwent a coronary artery bypass graft (CABG) surgery using a saphenous vein graft with uneventful recovery. Right internal mammary artery (RIMA) was not used as it was flimsy and the flow was very poor.
    Matched MeSH terms: Computed Tomography Angiography
  19. Kow RY, Yuen JC, Low CL, Mohd-Daud KN
    Malays Orthop J, 2019 Nov;13(3):77-79.
    PMID: 31890116 DOI: 10.5704/MOJ.1911.014
    Supracondylar humeral fracture is the most common elbow injury in children. It may be associated with a vascular injury in nearly 20% of the cases with a pink pulseless limb. We present a unique case of a paediatric pink pulseless supracondylar humeral fracture, seen late, on the 16th-day post-trauma. Open reduction, cross Kirschner wiring, and brachial artery exploration and repair were performed, and the patient recovered well. Early open reduction and exploration of the brachial artery with or without prior CT angiography was a safe approach in treating patients who presented at 16 days.
    Matched MeSH terms: Computed Tomography Angiography
  20. Cheong, Chee Yen, Rashidi Ahmad, Nesarajah, Kiran, Aida Bustam, Muhaimin Noor Azhar
    MyJurnal
    Diagnosis of pulmonary embolism (PE) remains a challenge in clinical practice, especially in emergency setting despite availability of various diagnostic tools. It is desirable to have a rapid and accurate bedside test to rule out PE.The aim of this study is to evaluate the diagnostic accuracyof CUEPED, a novel method of ruling out pulmonary embolism using a combination of end-tidal CO2(ETCO2), Compression Ultrasonography (CUS) and Transthoracic Echocardiography (TTE).In this pilot study, patients who presented to the Emergency Department at Univers it y Malaya Medical Centre with suspected acute PE from December 2013 to October 2014,who fulfilled the inclusion and exclusion criteria, were assessed using CUEPED. CUEPED was considered positive if the measured ETCO2 was less than 35 mmHg, or if there was presence of venous incompressibility in lower limb ultrasonography orif tricuspid annular plane systolic excursion (TAPSE) in transthoracic echocardiography was less than 1.6. All patients received a computed tomography pulmonary angiography (CTPA) for confirmation of diagnosis. Data obtained was analyzed to determine if a negative CUEPED has the potential to accurately rule out a PE. 30 patients (mean age = 48 years [SD = 13.6]) were involved with an equal distribut io nbetween gender. The incidence of PE was 56.7%. CUEPED had a sensitivity of 100% for PE. Negative CUEPED ruled out PE with a negative predictive value of 100%. Positive CUEPED ruled in PE with a low specificity of 53.8% and moderate positive predictive value of 73.9%. This diagnostic study showedthat a negative CUEPED is potentially accurate in ruling out PE.
    Matched MeSH terms: Computed Tomography Angiography