Displaying publications 21 - 39 of 39 in total

Abstract:
Sort:
  1. Nam HY, Murali MR, Ahmad RE, Pingguan-Murphy B, Raghavendran HRB, Kamarul T
    Stem Cells Int, 2020;2020:5385960.
    PMID: 32908542 DOI: 10.1155/2020/5385960
    It has been suggested that mechanical strain may elicit cell differentiation in adult somatic cells through activation of epithelial sodium channels (ENaC). However, such phenomenon has not been previously demonstrated in mesenchymal stromal cells (MSCs). The present study was thus conducted to investigate the role of ENaC in human bone marrow-derived MSCs (hMSCs) tenogenic differentiation during uniaxial tensile loading. Passaged-2 hMSCs were seeded onto silicone chambers coated with collagen I and subjected to stretching at 1 Hz frequency and 8% strain for 6, 24, 48, and 72 hours. Analyses at these time points included cell morphology and alignment observation, immunocytochemistry and immunofluorescence staining (collagen I, collagen III, fibronectin, and N-cadherin), and gene expression (ENaC subunits, and tenogenic markers). Unstrained cells at similar time points served as the control group. To demonstrate the involvement of ENaC in the differentiation process, an ENaC blocker (benzamil) was used and the results were compared to the noninhibited hMSCs. ENaC subunits' (α, β, γ, and δ) expression was observed in hMSCs, although only α subunit was significantly increased during stretching. An increase in tenogenic genes' (collagen1, collagen3, decorin, tenascin-c, scleraxis, and tenomodulin) and proteins' (collagen I, collagen III, fibronectin, and N-cadherin) expression suggests that hMSCs underwent tenogenic differentiation when subjected to uniaxial loading. Inhibition of ENaC function resulted in decreased expression of these markers, thereby suggesting that ENaC plays a vital role in tenogenic differentiation of hMSCs during mechanical loading.
    Matched MeSH terms: Silicones
  2. Aiemeeza Rajali, Siti Fauzza Ahmad
    MyJurnal
    Introduction: The compatibility of denture cleanser is crucial in the prevention of failure of adhesion between silicone soft liner and acrylic denture base, thus ensuring the durability of the prosthesis. This scanning electron microscope (SEM) study was to determine the mode of failure and measured the gap formation between silicone soft liners and Polymethylmethacrylate (PMMA) denture base after immersion in denture cleansers. Methods: A total of 135 specimens of PMMA denture base lined with three different silicone soft liners (GC Reline Soft, Mollosil and Tokuyama Sofreliner Tough) were immersed into denture cleansers (Polident® and Stearadent) daily and stored in distilled water at 37±1°C. Specimens were examined and sectioned at 2.5mm and 5.0mm from the margin after 1 day, 30 days and 90 days before analyzed. Results: No significant difference detected in the mode of failure and gap formation after one-day immersion. Adhesive failure was the commonest failure at the margin after 30 days (71.11%) and after 90 days (95.56%). However, 33.33% of specimens showed mixed failure at 5.0mm sectioned after 90 days. A significant difference of gap formation was demonstrated from Mollosil in Steradent at the margin and at 2.5 mm sectioned after 30 days and after 90 days (p
    Matched MeSH terms: Silicones
  3. Goh, W.N., Rosma, A., Kaur, B., Fazilah, A., Karim, A.A., Rajeev Bhat
    MyJurnal
    In this study, we evaluated and characterized microbial cellulose produced from Kombucha after eighth day of fermentation by employing SEM, FTIR, X-ray diffractometry, adsorption isotherm, and by measuring the swelling properties. Results on SEM revealed microbial cellulose layer to be composed of a compact cellulose ultrafine network like structure. FTIR spectra showed the presence of a characteristic region of anomeric carbons (960 – 730 cm-1), wherein a band at 891.59 cm-1 confirmed the presence of β, 1-4 linkages. Results of FTIR spectra also showed microbial cellulose to be free from contaminants such as lignin or hemicellulose, which are often present in plant cellulose. X-ray diffraction studies exhibited the overall degree of crystallinity index for MCC to be slightly lower than that of microbial cellulose. Results on swelling properties indicated microbial cellulose to possess higher fiber liquid retention values (10-160%) compared to commercial MCC (5-70%). The adsorption isotherm curves showed similarities between microbial cellulose with that of pure crystalline substance. Overall, results obtained in this study were comparable with the commercial microcrystalline cellulose, indicating that the process developed by us can be explored industrially on a pilot scale.
    Matched MeSH terms: Silicones
  4. Bastion, M.L.C., Siti Aishah, S., Aida Zairani, M.Z., Barkeh, H.J.
    Medicine & Health, 2010;5(2):93-102.
    MyJurnal
    A retrospective case series review was conducted to determine the pre-operative role and safety of pre-operative adjunctive anti-vascular endothelial growth factor (anti- VEGF) agent ranibizumab “LUCENTISTM” in patients with diabetic retinopathy requiring vitrectomy. The study involved twenty consecutive eyes of sixteen patients (age range: 46-72 years; mean 57.5 years) which received intravitreal injection of 0.5 - 1 mg of ranibizumab 3 to 8 days (mean 4.4 days) prior to vitrectomy for diabetic retinopathy. There were no local or systemic post-injection complications. Indications for vitrectomy were retinal detachment (RD) [n=11; 3 combined tractional (TRD) - rhegmatogenous RD (RRD), 8 TRD], TRD with vitreous haemorrhage (VH) (n=3) ,VH (n=8) and vitreomacular traction syndrome (n=1). Inclusion criteria include all consecutive eyes of diabetic patients requiring vitrectomy receiving a first pre-operative injection of anti- VEGF. Pre-operative visual acuity (VA) ranged from 6/36 to light perception. All eyes had minimal to moderate intraoperative bleeding. Post-operative VH in eyes without tamponade or gas tamponade was nil (n=1), mild (n=13) or moderate (n=1). Silicone filled eyes had nil (n=1), moderate (n=3) or severe haemorrhages (n=1). Post-operative VA was unchanged (n=2) (10%), improved (n = 14) (70%) or worsened (n=4). VA was 2/60 or better (n=15) to no light perception (n=1). Two eyes achieved 6/12 or better vision (10%). Ten eyes (50%) had 6/36 or better vision. In conclusion, pre-operative intravitreal ranibizumab is safe and useful in diabetic vitrectomy and appears to help with perioperative bleeding leading to improvement in vision.
    Matched MeSH terms: Silicones
  5. Mohd NI, Zain NNM, Raoov M, Mohamad S
    R Soc Open Sci, 2018 Apr;5(4):171500.
    PMID: 29765632 DOI: 10.1098/rsos.171500
    A new cloud point methodology was successfully used for the extraction of carcinogenic pesticides in milk samples as a prior step to their determination by spectrophotometry. In this work, non-ionic silicone surfactant, also known as 3-(3-hydroxypropyl-heptatrimethylxyloxane), was chosen as a green extraction solvent because of its structure and properties. The effect of different parameters, such as the type of surfactant, concentration and volume of surfactant, pH, salt, temperature, incubation time and water content on the cloud point extraction of carcinogenic pesticides such as atrazine and propazine, was studied in detail and a set of optimum conditions was established. A good correlation coefficient (R2 ) in the range of 0.991-0.997 for all calibration curves was obtained. The limit of detection was 1.06 µg l-1 (atrazine) and 1.22 µg l-1 (propazine), and the limit of quantitation was 3.54 µg l-1 (atrazine) and 4.07 µg l-1 (propazine). Satisfactory recoveries in the range of 81-108% were determined in milk samples at 5 and 1000 µg l-1, respectively, with low relative standard deviation, n = 3 of 0.301-7.45% in milk matrices. The proposed method is very convenient, rapid, cost-effective and environmentally friendly for food analysis.
    Matched MeSH terms: Silicones
  6. Bin Sahadan MY, Tong WY, Tan WN, Leong CR, Bin Misri MN, Chan M, et al.
    Exp Eye Res, 2019 01;178:10-14.
    PMID: 30243569 DOI: 10.1016/j.exer.2018.09.011
    Microbial keratitis is the infection caused by pathogenic microorganisms that commonly occurs among the contact lens users. Various antimicrobial compounds were coated on contact lenses to kill keratitis causing microorganisms, however these compounds caused several adverse side effects. Hence, the aim of this study is to develop a silicone hydrogel contact lens coated with phomopsidione nanoparticle that inhibit keratitis causing clinical isolates. Phomopsidione nanoparticles were synthesized using polyvinyl alcohol as encapsulant. The nanoparticles showed an average size of 77.45 nm, with neutral surface charge. Two drug release patterns were observed in the drug release profile, which are the initial slow release phase with extended drug release (release rate 46.65 μg/h), and the burst release phase observed on Day 2 (release rate 2224.49 μg/h). This well-regulated drug delivery system enables the control of drug release to meet the therapeutic requirements. On agar diffusion assay, 3 out of 5 test microorganisms were inhibited by phomopsidione nanoparticle coated contact lenses, including two Gram negative bacteria. Besides, all test microorganisms showed at least 99% of growth reduction, with the treatment of the contact lens model. The drug loaded onto the nanoparticles is sufficient to prevent the bacterial growth. In conclusion, this study provides an effective alternative to combat keratitis-causing microorganisms among contact wearers.
    Matched MeSH terms: Silicones
  7. Xue Y, Zhang W, Lei Y, Dang M
    J Pharm Sci, 2020 05;109(5):1714-1724.
    PMID: 32007507 DOI: 10.1016/j.xphs.2020.01.022
    Olopatadine HCl is an antiallergic drug used for the management of allergic conjunctivitis. Currently, it is delivered via eye drop solution, which is highly inefficient due to low bioavailability. Silicone contact lenses can be used to sustain the release of ophthalmic drugs. However, the presence of drug alters the optical transmittance and physical properties of the contact lens. The objective was to design a novel polyvinyl pyrrolidone (PVP)-coated olopatadine-ethyl cellulose microparticles-laden doughnut contact lens to sustained ocular delivery with limited alteration to the optical and swelling properties of the contact lens. The doughnut was implanted within the periphery of the lens using modified casting technique. Olopatadine HCl was loaded by soaking (SM-OL), direct loading (DL-OL), and doughnut casting method (DNT-OL). PVP (comfort agent) was loaded on the surface of contact lens for all the batches via novel curing technique. The in vitro olopatadine HCl release data of SM-OL (up to 48-72 h) and DL-OL batches (up to 72 h) showed high burst release, whereas DNT-OL batch showed sustained release up to 120 h without significant (p > 0.05) alteration in the optical and swelling properties of contact lens. All the batches showed sustained release of PVP up to 120 h. The in vivo studies in the rabbit tear fluid showed improvement in the olopatadine HCl and PVP retention time in comparison to eye drop solution. The PVP-loaded DNT-OL-500 lens showed tear stabilization (comfort wear) in Schirmer strip test (rabbits) with no protein adherence in comparison to DNT-OL-500 lens without PVP. The study demonstrated the successful delivery of olopatadine HCl and PVP-K30 from the doughnut contact lens for the extended period with limited alteration to the optical and swelling properties of contact lens.
    Matched MeSH terms: Silicones
  8. Salauddin SA, Ghazali H
    Malays J Med Sci, 2019 Nov;26(6):137-142.
    PMID: 31908595 MyJurnal DOI: 10.21315/mjms2019.26.6.14
    Background: Penile augmentation using injection of a foreign body into penile skin was mainly performed by non-medical personnel. Majority of these patients end up with complication of an abnormal mass formation known as penile paraffinoma.

    Methods: We described three different surgical techniques for correction of penile paraffinoma based on our single-centre experience. Informed consents were obtained from patients whose photographs were taken during the operation step.

    Results: In general, three patients had simple excision biopsy with primary suturing, four patients underwent single stage excision of circumferential granuloma with bilateral scrotal skin flap reconstruction and one patient experienced dual stage procedure. Three of them were injected with paraffin, one with silicone and the remaining four were unable to identify the substance used. All patients successfully underwent the surgical procedure and four of them had minor post-operative surgical site infection and wound gapping.

    Conclusion: All patients recovered well and the mean International Index of Erectile Function (IIEF-5) score obtained was 24.25. In our experience, excision biopsy was adequate for focal mass and reconstructive surgery using bilateral scrotal flap was suitable for circumferential mass.

    Matched MeSH terms: Silicones
  9. Inn FX, Imran FH, Ali MF, Ih R, Z Z
    Malays J Med Sci, 2012 Oct;19(4):81-3.
    PMID: 23613653 MyJurnal
    Throughout history, a proportion of men appear to correlate penis size and dimensions directly with physical fitness and sexual prowess. Foreign materials, such as paraffin oil, paraffin balm, mineral oils, and silicone, have been used to promise an improvement in penile shaft contour and dimensions. These materials are injected directly into the penis; inducing granuloma formation to achieve increased penis length and girth. However, the result is a severely disfigured and swollen penis, which cannot achieve erection. Local complications of penile lipogranuloma include infection, ulceration, local migration, and cavernosal invasion; leading to functional impairment. Meanwhile, systemic complications include foreign body embolization, organ infarct, and death. Penile lipogranuloma is best treated surgically. Granulomatous skin needs to be completely excised; wound closure with a scrotal skin flap, Cecil's inlay operation and split thickness skin graft commonly used options. Our case series has shown that penile lipogranuloma, induced by subcutaneous foreign body injections into the penile shaft, and its subsequent adverse outcomes to patients and their partners.
    Matched MeSH terms: Silicones
  10. Soh SC, Abdullah MP
    Environ Monit Assess, 2007 Jan;124(1-3):39-50.
    PMID: 16967208
    A field investigation was conducted at all water treatment plants throughout 11 states and Federal Territory in Peninsular Malaysia. The sampling points in this study include treatment plant operation, service reservoir outlet and auxiliary outlet point at the water pipelines. Analysis was performed by solid phase micro-extraction technique with a 100 microm polydimethylsiloxane fibre using gas chromatography with mass spectrometry detection to analyse 54 volatile organic compounds (VOCs) of different chemical families in drinking water. The concentration of VOCs ranged from undetectable to 230.2 microg/l. Among all of the VOCs species, chloroform has the highest concentration and was detected in all drinking water samples. Average concentrations of total trihalomethanes (THMs) were almost similar among all states which were in the range of 28.4--33.0 microg/l. Apart from THMs, other abundant compounds detected were cis and trans-1,2-dichloroethylene, trichloroethylene, 1,2-dibromoethane, benzene, toluene, ethylbenzene, chlorobenzene, 1,4-dichlorobenzene and 1,2-dichloro - benzene. Principal component analysis (PCA) with the aid of varimax rotation, and parallel factor analysis (PARAFAC) method were used to statistically verify the correlation between VOCs and the source of pollution. The multivariate analysis pointed out that the maintenance of auxiliary pipelines in the distribution systems is vital as it can become significant point source pollution to Malaysian drinking water.
    Matched MeSH terms: Silicones/chemistry
  11. Mohd NI, Gopal K, Raoov M, Mohamad S, Yahaya N, Lim V, et al.
    Talanta, 2019 May 01;196:217-225.
    PMID: 30683354 DOI: 10.1016/j.talanta.2018.12.043
    The non-ionic silicone surfactant (OFX 0309) has been applied in cloud point extraction for the extraction of triazine herbicides in food samples. Evidence has shown that the non-ionic silicone surfactant demonstrated a good performance as an extractor toward triazine herbicides. In this present study, OFX 0309 surfactant was combined with activated charcoal (AC) due to their valuable properties. Activated charcoal modified with non-ionic silicone surfactant coated with magnetic nanoparticles (AC-OFX MNPs) was synthesized and characterized by FT-IR, VSM, SEM, TEM and BET. This novel material was applied as a magnetic adsorbent for the pre-concentration and separation of triazine herbicides due to hydrophobic interaction between polysiloxane polyether of OFX 0309 surfactant and triazine herbicides. Under optimal conditions, the proposed magnetic solid phase extraction method using AC-OFX MNPs adsorbent was applied to extract triazine herbicides from selected milk and rice samples using high performance liquid chromatography coupled with diode array detector. The validation method revealed a good linearity (1 - 500 μg L-1) with the coefficient of determination (R2) in the range of 0.992-0.998 for the samples. The limits of detection (LOD) of the developed method were 0.04 - 0.05 µg L-1 (milk sample) and 0.02 - 0.05 µg L-1 (rice sample). The limits of quantification (LOQ) were 0.134 - 0.176 µg L-1 (milk sample) and 0.075 - 0.159 µg L-1 (rice sample). The recoveries of the triazine compounds ranged from 81% to 109% in spiked milk samples and from 81% to 111% in spiked rice samples, with relative standard deviations (RSD) values lower than 13.5% and 12.1% for milk and rice samples, respectively. To the best of our knowledge, this is the first study that have investigated the use of magnetic nanoparticles coated activated charcoal modified with OFX 0309 surfactant for pretreatment of triazine herbicides in food samples analysis for simultaneous separation of organic pollutants.
    Matched MeSH terms: Silicones/chemistry*
  12. Chai M, Tan G, Lal A
    Anal Sci, 2008 Feb;24(2):273-6.
    PMID: 18270422
    A headspace solid-phase microextraction method has been developed for the determination of 8 pesticides in vegetables and fruits by using gas chromatography with an electron capture detector. Two types of fibers (polyacrylate, 85 microm and polydimethylsiloxane, 100 microm) have been assayed and compared. The main factors: extraction and desorption parameters, ionic strength, and the effects of dilution and organic solvents, were studied and optimized. The optimized procedures resulted in more than 80% recovery for all the investigated vegetable and fruit samples with RSD values below 10%.
    Matched MeSH terms: Silicones/chemistry
  13. Mustafa NA, Lope RJ, Cheah FC
    PMID: 16790731
    Matched MeSH terms: Silicones
  14. Foo LC, Zainab T, Goh SY, Letchuman GR, Nafikudin M, Doraisingam P, et al.
    Biomed Environ Sci, 1996 Sep;9(2-3):236-41.
    PMID: 8886337
    A simple water iodizing system, which incorporates the Venturi principle in combination with the controlled release mechanism of a silicone-sodium iodide elastomer, for the iodization of rural piped-water supply in the control of endemic iodine deficiency has been developed and its effectiveness evaluated in three Iban longhouse villages in the iodine-deficient district of Lubok Antu, Sarawak. Urines were collected for iodine assays from women aged 15-40 years before and at 6 and 12 months after the connection of the iodinating device; goiter assessment was performed on the women at the start and end of the 1-year study. Water samples were collected for iodine assays at 2-weekly intervals. In all three villages, significant and sustained increases in median urinary iodine excretions, reaching levels recommended for an iodine-sufficient population, were observed; goitre prevalences were reduced in all the villages (by 22.6% to 35.8%). The iodine levels in the water ranged from 34 micrograms/l to 212 micrograms/L. In the control village, median urinary iodine excretions remained essentially unchanged but a small increase in goiter prevalence was observed. The iodized water was well received by the villagers and no adverse effects of water iodization were observed. The system functioned unattended throughout the one year period. The cost of providing supplemental iodine via the iodizing device is approximately 60 cents (U.S.) per family per year which is affordable by either the Government or the villagers. It is concluded that the iodizing system offers a new cost-effective strategy for the control of endemic iodine deficiency in Sarawak and may have applications in other areas with similar water sources.
    Matched MeSH terms: Silicones
  15. Nor NM, Ismail R, Jamil A, Shah SA, Imran FH
    Clin Drug Investig, 2017 Mar;37(3):295-301.
    PMID: 27888448 DOI: 10.1007/s40261-016-0484-x
    BACKGROUND AND OBJECTIVE: Keloid is conventionally treated with intra-lesional (IL) triamcinolone, which is highly operator dependent and has its own adverse effects. Topical steroid and silicone dressings are a patient friendly and non-invasive treatment alternative. We therefore sought to determine the efficacy and safety of topical clobetasol propionate (Dermovate(®)) 0.05% cream under occlusion with Mepiform(®) silicone dressing compared to IL triamcinolone in the treatment of keloid.

    METHODS: This was a prospective, randomised, observer-blinded study. Two keloids on the same site were randomly assigned to receive either daily topical clobetasol propionate 0.05% cream under occlusion with silicone dressing (Scar 1) or monthly IL triamcinolone injection (Scar 2). Efficacy was assessed using patient and observer scar assessment scale (POSAS) at 4-weekly intervals up to 12 weeks. Dimension of keloid and adverse effects were also assessed.

    RESULTS: A total of 34 scars from 17 patients completed the study. There was significant improvement of POSAS at 12 weeks compared to baseline within each treatment group. However, there was no statistically significant difference in POSAS at 12 weeks between the two treatments. Keloid dimensions showed a similar trend of improvement by week 12 with either treatment (p = 0.002 in Scar 1, p = 0.005 for Scar 2). However, there was no significant difference between the treatment. In the IL triamcinolone group, all patients reported pain and 70.6% observed necrotic skin reaction. There was a significantly higher rate of adverse effects such as erythema (41.2 vs. 17.6%), hypopigmentation (35.3 vs. 23.5%), telangiectasia (41.2 vs. 17.6%) and skin atrophy (23.5 vs. 5.9%) documented in the IL triamcinolone group when compared to clobetasol propionate 0.05% cream under occlusion with silicone dressing.

    CONCLUSION: Clobetasol propionate 0.05% cream under occlusion with silicone dressing is equally effective and has fewer adverse effects compared to IL triamcinolone. Hence, it may be used as an alternative treatment for keloid particularly in patients with low pain threshold, needle phobia and those who prefers home-based treatment.

    Matched MeSH terms: Silicones
  16. Norshamsiah, M.D., Muhaya, M., Bastion, M.L.C.
    MyJurnal
    A 24-year-old Chinese gentleman presented with two weeks history of sudden floaters in his right temporal visual field associated with blurring of vision. This ex-smoker also reported chronic, bloody cough for two years and recent pleuritic chest pain. Examination revealed a thin patient with right eye visual acuity of 6/18 associated with optic nerve dysfunction, optic disc swelling and macula star, retinal vasculitis and retinitis. Despite anti-tuberculosis medication and corticosteroids, he developed neovascularisation. Subsequent vitreous haemorrhage necessitated trans pars plana vitrectomy, membrane peeling, endolaser and silicone oil injection. Final visual acuity was 6/9 with quiescent retinopathy.
    Matched MeSH terms: Silicones
  17. Abu Osman NA, Gholizadeh H, Eshraghi A, Wan Abas WAB
    Prosthet Orthot Int, 2017 Oct;41(5):476-483.
    PMID: 28946824 DOI: 10.1177/0309364616670396
    OBJECTIVES: This study aimed to evaluate and compare a newly designed suspension system with a common suspension in the market.

    STUDY DESIGN: Prospective study.

    METHODS: Looped liners with hook fastener and Iceross Dermo Liner with pin/lock system were mechanically tested using a tensile testing machine in terms of system safety. A total of 10 transtibial amputees participated in this study and were asked to use these two different suspension systems. The pistoning was measured between the liner and socket through a photographic method. Three static axial loading conditions were implemented, namely, 30, 60, and 90 N. Furthermore, subjective feedback was obtained.

    RESULTS: Tensile test results showed that both systems could safely tolerate the load applied to the prosthesis during ambulation. Clinical evaluation confirmed extremely low pistoning in both systems (i.e. less than 0.4 cm after adding 90 N traction load to the prosthesis). Subjective feedback also showed satisfaction with both systems. However, less traction at the end of the residual limb was reported while looped liner was used.

    CONCLUSION: The looped liner with hook fastener is safe and a good alternative for individuals with transtibial amputation as this system could solve some problems with the current systems. Clinical relevance The looped liner and hook fastener were shown to be good alternative suspension for people with lower limb amputation especially those who have difficulty to use and align the pin/lock systems. This system could safely tolerate centrifugal forces applied to the prosthesis during normal and fast walking.

    Matched MeSH terms: Silicones
  18. Seluakumaran K, Kamal Azizi A, Kulasegarah J
    Int J Audiol, 2024 Jul;63(7):551-559.
    PMID: 37139683 DOI: 10.1080/14992027.2023.2205008
    OBJECTIVE: Consumer-grade insert earphones (IEs) can be utilised for audiometry, but their calibration values and threshold reliability may differ from the audiometric IE. This study measured the equivalent threshold sound pressure levels (ETSPLs), and the test-retest threshold variation when a consumer IE (Sennheiser CX100) was fitted with: (1) silicone stock ear tips that came along with the earphone, (2) replacement foam ear tips (KZ acoustics) and (3) silicone otoacoustic emission (OAE) probe ear tips.

    DESIGN AND STUDY SAMPLE: Study 1 determined ETSPL values in 25 normal-hearing subjects aged 18-25 years at seven test frequencies (500-8000 Hz). Study 2 assessed the intra- and inter-session test-retest threshold reliability in a separate group of 50 adult subjects.

    RESULTS: The ETSPL values for the consumer IE deviated from the reference values for audiometric IEs, with the largest differences (7-9 dB) observed at 500 Hz across ear tips. This is likely related to shallow tip insertions. However, test-retest threshold variations were comparable to those reported for audiometric transducers.

    CONCLUSIONS: Ear tip-specific corrections to the reference thresholds in the standards are required for calibration of consumer IEs used in low-cost audiometry when their ear tips only allow superficial insertion into the ear canal.

    Matched MeSH terms: Silicones
  19. Tan JH, Sivadurai G, Tan HCL, Tan YR, Jahit S, Hans Alexander M
    Surg Laparosc Endosc Percutan Tech, 2020 Apr;30(2):106-110.
    PMID: 31923160 DOI: 10.1097/SLE.0000000000000754
    BACKGROUND: Provision of enteral nutrition with jejunal feeding in upper gastrointestinal obstruction is highly recommended. Access to jejunum can be obtained surgically, percutaneously, or endoscopically. Our institution routinely and preferentially utilizes a silicone nasojejunal tube that is inserted past the obstruction endoscopically. We use a custom dual channel tube that allows feeding at the distal tip and another channel 40 cm from the tip that enables decompression proximally. This is a report of our experience with this custom nasojejunal tube.

    METHODS: This is a prospective observational study of 201 patients who underwent endoscopic nasojejunal wire-guided feeding tube insertions for obstruction of either the esophagus or the stomach including both benign and malignant pathologies between January 2015 to June 2018 in Hospital Sungai Buloh and Hospital Sultanah Aminah, Malaysia. The indications for tube insertion, insertion technique, and tube-related problems were described.

    RESULTS: The nasojejunal tube was used to establish enteral feeding in patients with obstructing tumors of the distal esophagus in 65 patients (32.3%) and gastric outlet obstruction in 72 patients (35.8%). There were 54 patients (26.9%) who required reinsertion. The most common reason for reinsertion was unintentional dislodgement, where 32 patients (15.9%) followed by tube blockage 20 patients (10.0%). Using our method of advancement under direct vision, we had only 2 cases of malposition due to severely deformed anatomy. We had no incidence of aspiration in this group of patients and overall, the patients tolerated the tube well.

    CONCLUSIONS: The novel nasojejunal feeding tube with gastric decompression function is a safe and effective method of delivery of enteral nutrition in patients with upper gastrointestinal obstruction. These tubes if inserted properly are well tolerated with almost no risk of malposition and are tolerated well even for prolonged periods of time until definitive surgery could be performed.

    Matched MeSH terms: Silicones
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links