Displaying publications 41 - 60 of 162 in total

Abstract:
Sort:
  1. Alwi M, Kang LM, Samion H, Latiff HA, Kandavel G, Zambahari R
    Am J Cardiol, 1997 May 15;79(10):1430-2.
    PMID: 9165178 DOI: 10.1016/s0002-9149(97)00160-4
    Two hundred eleven patients with small- to moderate-sized native patent ductus arteriosus underwent closure using Gianturco coils, employing the transvenous multiple catheter approach. Short-term results showed a high rate of complete occlusion and a potential long-term complication of mild left pulmonary artery stenosis in a small number of patients.
    Matched MeSH terms: Cardiac Catheterization*
  2. Goh BL
    Contrib Nephrol, 2017;189:79-84.
    PMID: 27951553
    BACKGROUND: The success rate of peritoneal dialysis (PD) catheter insertion is known to vary among different operators and may be influenced by many factors such as patient and various situational factors. Traditionally, surgeons have inserted Tenckhoff catheters by mini-laparotomy or an open technique. However, with recent advances in endoscopic instrumentation and video capabilities, peritoneoscope Tenckhoff catheter insertion has become a viable approach in interventional nephrologist-initiated PD access programmes.

    SUMMARY: Nephrologist-initiated peritoneoscopic PD access programs have had a positive impact on PD penetration. The technique has been associated with a better primary success rate, superior catheter survival, less postoperative pain, shorter hospital stay, and shorter catheter break-in time compared with the conventional surgical technique. The role of interventional nephrologists in peritoneoscope Tenckhoff catheter placement is still perceived to be a relatively new advance, investigational by some, and many nephrologists and surgeons alike remain sceptical of the value of this recent option. Crucial questions often raised are how many procedures one needs to perform before being considered competent and who should be credentialed to perform the procedure or supervise trainees performing it. The evaluation of technical proficiency in a specific operation is difficult and complex. Cumulative summation (CUSUM) analysis is one option for tracking the success and failure of technical skill and examining trends over time. Key Messages: The author's facility has had good outcomes with a nephrologist-initiated peritoneoscopic PD access programme. Quality control of PD catheter insertion can be performed using CUSUM charting to monitor for primary catheter dysfunction, primary leak, and primary peritonitis.

    Matched MeSH terms: Catheterization/methods*
  3. Abrahamyan L, Barker M, Dharma C, Lee DS, Austin PC, Asghar A, et al.
    Int J Cardiol, 2023 Jan 15;371:109-115.
    PMID: 36165815 DOI: 10.1016/j.ijcard.2022.09.033
    BACKGROUND: Patent foramen ovale (PFO) is a congenital heart defect associated with an increased risk of cryptogenic stroke. We aimed to evaluate real-world outcomes of adult patients undergoing transcatheter PFO closure with the Amplatzer PFO Occluder.

    METHODS: In this single centre, retrospective cohort study, we linked a detailed clinical registry with provincial administrative databases to obtain short and long-term outcomes. Validated algorithms were used to established baseline comorbidities and adverse outcomes.

    RESULTS: Between 1999 and 2017, 479 patients had PFO closure with an Amplatzer PFO Occluder. The average age of the patients was 47.3 years (standard deviation (SD) = 12.4), and 54.7% were males. The procedural success was 100%, and 96% of patients were discharged on the same day. Any in-hospital complication was observed in 2.5% (n = 12) of patients. At 30 days post-discharge, 18% of patients had an ED visit and 5% a hospitalization. Over a mean follow-up of 9.1 (SD = 3.8) years, 4% experienced TIA, 1.5% stroke, and 7.6% atrial fibrillation. The composite outcome of stroke/TIA/death was observed in 10.9% of patients (1.22 events per 100 person-years). Patients >60 years old experienced higher rates of adverse events than younger patients.

    CONCLUSIONS: In this large real-world cohort of patients with cryptogenic stroke, we observed excellent safety and effectiveness outcomes for PFO closure conducted with Amplatzer PFO Occluder, similar to randomized controlled trials or other long-term cohort studies. New onset atrial fibrillation was one of the most commonly adverse events. Future studies should investigate early post-discharge management of patients to prevent readmissions.

    Matched MeSH terms: Cardiac Catheterization/adverse effects
  4. Engkasan JP, Shun CL, Rathore FA
    J Pak Med Assoc, 2023 Oct;73(10):2123-2125.
    PMID: 37876089 DOI: 10.47391/JPMA.23-77
    Neurogenic bladder is one of the negative consequences following a spinal cord injury (SCI). SCI patients who have neurogenic bladder depend on alternative methods to drain urine from their bladder. These include indwelling catheters, reflex voiding , suprapubic tapping and intermittent catheterisation. This review summarizes evidence from the literature of five selected complications (renal failure, urinary tract infections, calculi, urethral stricture, and bladder cancer) that could result from use of the different bladder drainage methods. There is inconsistent evidence to support the superiority of intermittent over indwelling catheterisation on risk of renal impairment, urethral stricture, and renal calculi. Indwelling catheterisations are associated with higher risk of bladder calculi and cancer. Caution needs to be taken when interpreting this review, as many of its findings are from retrospective studies, and more than a decade old. Clinicians need to communicate the evidence to their patients when making the decision on method of bladder drainage.
    Matched MeSH terms: Urinary Catheterization/adverse effects
  5. Abdullah BJ, Mohammad N, Sangkar JV, Abd Aziz YF, Gan GG, Goh KY, et al.
    Br J Radiol, 2005 Jul;78(931):596-600.
    PMID: 15961840
    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).
    Matched MeSH terms: Catheterization, Central Venous/adverse effects*; Catheterization, Central Venous/instrumentation; Catheterization, Central Venous/methods
  6. Abdul Aziz B, Alwi M
    Catheter Cardiovasc Interv, 1999 Oct;48(2):191-3.
    PMID: 10506777
    We report a case of a 14-month-old-infant with severe congenital mitral stenosis who presented with pulmonary oedema, acute renal failure and haemodynamic instability. Balloon dilatation was successfully performed under fluoroscopic and transesophageal echocardiographic guidance. Cathet. Cardiovasc. Intervent. 48:191-193, 1999.
    Matched MeSH terms: Catheterization/instrumentation*; Cardiac Catheterization/instrumentation
  7. Khoo PJ, Tay KL, Jamaluddin AA, Gunasaker D
    Ann Med Surg (Lond), 2018 Sep;33:44-46.
    PMID: 30167303 DOI: 10.1016/j.amsu.2018.08.004
    Introduction: We present a case of broken peripheral intravenous catheter/cannula (PIVC), a well-known, underreported complication of PIVC placement. The fractured cannula could have resulted in intravascular foreign body retention, which is usually iatrogenic.

    Presentation of case: In this case, we conceded that both iatrogenic and self-infliction were culpable. The intoxicated, aggressive patient forcefully removed the inserted cannula after repeated attempts by medical personnel to place it. The same cannula was used for multiple attempts. After the location of the fractured catheter was reconfirmed with radiological imaging, venotomy and removal of the foreign body were performed.

    Conclusion: Due to potentially devastating consequences, early detection, adherence to standard operating procedures for peripheral venous access, management of aggressive patients, and meticulous teamwork must be upheld.

    Matched MeSH terms: Catheterization, Peripheral
  8. Lew YS, Lim SK
    Med J Malaysia, 1998 Sep;53(3):227-31.
    PMID: 10968158
    An approach to cannulate right internal jugular vein in neutral head position is described for situations where head rotation and extension are contraindicated. Venous puncture was made immediately lateral to the carotid artery at the level of cricoid cartilage and directed caudad. In 40 patients studied, the right internal jugular vein of 97.5% of the patients were successfully located by the finder needle. The mean (SE) number of puncture attempts to locate the vein was 1.3 (0.1) per patient. In 72.5% (29 patients), the veins were located exactly at the predicted point after the first attempt. However the overall success rate for cannulation by the angiocath cannula was 87.5% and short term complication rate was 5.0%. We conclude this technique is a reliable, safe alternative for central venous access, especially in patients where cervical spine movement is contraindicated or restricted.
    Matched MeSH terms: Catheterization/adverse effects; Catheterization/methods*
  9. Crabtree JH, Shrestha BM, Chow KM, Figueiredo AE, Povlsen JV, Wilkie M, et al.
    Perit Dial Int, 2019 04 26;39(5):414-436.
    PMID: 31028108 DOI: 10.3747/pdi.2018.00232
    Matched MeSH terms: Catheterization/methods*; Catheterization/standards
  10. Engkasan JP, Ng CJ, Low WY
    Spinal Cord, 2015 Feb;53(2):130-4.
    PMID: 25403504 DOI: 10.1038/sc.2014.199
    STUDY DESIGN: Qualitative study using individual in-depth interviews.

    OBJECTIVE: To explore the roles of patients, their caregivers and doctors when making decisions on the method of bladder drainage after spinal cord injury (SCI).

    SETTING: Five public hospitals in Malaysia.

    METHODS: Semistructured (one-to-one) interviews with 17 male patients with SCI, 4 caregivers and 10 rehabilitation professionals.

    RESULTS: Eight themes describing the respective decisional roles of patients, their caregivers and doctors emerged from the analysis: patient's right and responsibilities, patient as an informed decision maker, forced to accept decision; surrogate decision maker, silent partner; doctor knows best, over-ride patient's decision, or reluctant decision maker. Both patients and doctors acknowledged the importance of patient autonomy but not all patients had the chance to practice it. Some felt that they were forced to accept the doctor's decision and even alleged that the doctor refused to accept their decision. Doctors considered the caregiver as the decision maker in cases that involved minors, elderly and those with tetraplegia. Some patients considered bladder problems an embarrassing subject to discuss with their caregivers and did not want their involvement. Doctors were described as knowledgeable and were trusted by patients and their caregivers to make the most appropriate option. Some doctors were happy to assume this role whereas some others saw themselves only as information providers.

    CONCLUSIONS: A paternalistic model is prevalent in this decision-making process and there is a discrepancy between patients' preferred and actual decisional roles.
    Matched MeSH terms: Catheterization/methods; Catheterization/psychology
  11. Yew KL
    Int J Cardiol, 2014 Dec 20;177(3):1127-8.
    PMID: 25150482 DOI: 10.1016/j.ijcard.2014.08.056
    Matched MeSH terms: Cardiac Catheterization/adverse effects*; Cardiac Catheterization/instrumentation
  12. Nusee Z, Ibrahim N, Rus RM, Ismail H
    Taiwan J Obstet Gynecol, 2014 Mar;53(1):12-6.
    PMID: 24767639 DOI: 10.1016/j.tjog.2013.01.028
    To determine the accuracy of bladder volume (BV) measurement and to identify factors that influenced the ultrasound bladder scanner (UBS) measurement of BV in postpartum women compared with transurethral catheterization.
    Matched MeSH terms: Urinary Catheterization/methods*; Urinary Catheterization/standards
  13. Waran V, Vairavan N, Sia SF, Abdullah B
    J. Neurosurg., 2009 Dec;111(6):1127-30.
    PMID: 19408977 DOI: 10.3171/2009.4.JNS081506
    The authors describe a newly developed expandable cannula to enable a more efficient use of an endoscope in removing intraparenchymal spontaneous hypertensive intracerebral hematomas. The cannula is introduced like a conventional brain cannula, using neuronavigation techniques to reach the targeted hematoma accurately, and, once deployed, conventional microsurgical techniques are used under direct endoscopic visualization. This method was used in 6 patients, and, based on the results of intraoperative intracranial pressure monitoring and postoperative CT scanning, the authors were able to achieve good hematoma removal. They found that by using the expandable cannula, efficient endoscopic surgery in the brain parenchyma was possible.
    Matched MeSH terms: Catheterization/instrumentation*; Catheterization/methods*
  14. Tay E, Muda N, Yap J, Muller DW, Santoso T, Walters DL, et al.
    Catheter Cardiovasc Interv, 2016 Jun;87(7):E275-81.
    PMID: 26508564 DOI: 10.1002/ccd.26289
    OBJECTIVES: The objective of this study is to describe and compare the use of the MitraClip therapy in mitral regurgitation (MR) patients with degenerative MR (DMR) and functional MR (FMR).

    INTRODUCTION: Percutaneous edge-to-edge repair of severe MR using the MitraClip device is approved for use in the USA for high risk DMR while European guidelines include its use in FMR patients as well.

    METHODS: The MitraClip in the Asia-Pacific Registry (MARS) is a multicenter retrospective registry, involving eight sites in five Asia-Pacific countries. Clinical and echocardiographic characteristics, procedural outcomes and 1-month outcomes [death and major adverse events (MAE)] were compared between FMR and DMR patients treated with the MitraClip.

    RESULTS: A total of 163 patients were included from 2011 to 2014. The acute procedural success rates for FMR (95.5%, n = 84) and DMR (92%, n = 69) were similar (P = 0.515). 45% of FMR had ≥2 clips inserted compared to 60% of those with DMR (P = 0.064).The 30-day mortality rate for FMR and DMR was similar at 4.5% and 6.7% respectively (P = 0.555). The 30-day MAE rate was 9.2% for FMR and 14.7% for DMR (P = 0.281). Both FMR and DMR patients had significant improvements in the severity of MR and NYHA class after 30 days. There was a significantly greater reduction in left ventricular end-diastolic diameter (P = 0.002) and end systolic diameter (P = 0.017) in DMR than in FMR.

    CONCLUSIONS: The MitraClip therapy is a safe and efficacious treatment option for both FMR and DMR. Although, there is a significantly greater reduction in LV volumes in DMR, patients in both groups report clinical benefit with improvement in functional class. © 2015 Wiley Periodicals, Inc.

    Matched MeSH terms: Cardiac Catheterization/adverse effects; Cardiac Catheterization/instrumentation*
  15. Alwi M, Budi RR, Mood MC, Leong MC, Samion H
    Cardiol Young, 2013 Apr;23(2):197-202.
    PMID: 22640635 DOI: 10.1017/S1047951112000595
    Objective: To determine the feasibility and safety of the Conquest Pro wire as an alternative to radiofrequency wire for perforation of atretic pulmonary valve and subsequent balloon dilatation and patent ductus arteriosus stenting in patients with pulmonary atresia with intact ventricular septum.
    Background: Radiofrequency valvotomy and balloon dilatation has become the standard of care for pulmonary atresia with intact ventricular septum in many institutions today.
    Methods: We report eight consecutive patients in whom we used the Conquest Pro coronary guidewire, a stiff wire normally reserved for revascularisation of coronary lesions with chronic total occlusion, for perforation of atretic pulmonary valve and subsequent balloon dilatation, and stenting of the patent ductus arteriosus.
    Results: Perforation of atretic pulmonary valve was successful in seven out of eight cases. Radiofrequency valvotomy was employed after failure of perforation by the Conquest Pro wire in one case where the right ventricular outflow tract was broad based and tapered towards the pulmonary valve, and was heavily trabeculated. Failure of the Conquest Pro wire to perforate the pulmonary valve plate was mainly attributed by the failure to engage the wire at the correct position.
    Conclusion: The Conquest Pro wire for perforation and subsequent interventions in the more straightforward cases of pulmonary atresia with intact ventricular septum is effective and safe, simplifying the entire procedure. However, the radiofrequency generator and wires remain essential tools in the paediatric interventional catheter laboratory.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*; Cardiac Catheterization/methods
  16. Boo NY, Suhaida AR, Rohana J
    Singapore Med J, 2015 Mar;56(3):164-8.
    PMID: 25532513
    This case-control study aimed to determine whether catheter use was significantly associated with coagulase-negative staphylococci (CoNS) colonisation and/or sepsis in neonates.
    Matched MeSH terms: Catheterization; Catheterization, Central Venous/adverse effects
  17. Fauzi AR, Jeyabalan V, Kong NC, Selvam T
    Saudi J Kidney Dis Transpl, 2003 Apr-Jun;14(2):194-6.
    PMID: 18209446
    Central vein stenosis is usually associated with previous cannulation or trauma to the affected vein. This pathology may present as ipsilateral arm swelling in patients in whom a recent arteriovenous fistula has been prepared for chronic hemodialysis. The presence of central vein stenosis without prior trauma or cannulation is not hitherto reported to the best of our knowledge. We herewith report a patient with end-stage renal disease who was initiated on chronic dialysis using an arteriovenous fistula, who was noted to have central vein stenosis. This was despite her never having had any central vein cannulation or previous known trauma. Venogram confirmed the presence of brachiocephalic vein stenosis. The patient underwent venographic stenting of the involved vein with good success.
    Matched MeSH terms: Catheterization, Central Venous
  18. Schramm J, Sivalingam S, Moreno GE, Thanh DQL, Gauvreau K, Doherty-Schmeck K, et al.
    Children (Basel), 2021 Mar 06;8(3).
    PMID: 33800765 DOI: 10.3390/children8030198
    Pulmonary vein stenosis (PVS) is a rare, but high mortality and resource intensive disease caused by mechanical obstruction or intraluminal myofibroproliferation, which can be post-surgical or idiopathic. There are increasing options for management including medications, cardiac catheterization procedures, and surgery. We queried the International Quality Improvement Collaborative for Congenital Heart Disease (IQIC) database for cases of PVS and described the cohort including additional congenital lesions and surgeries as well as infectious and mortality outcomes. IQIC is a quality improvement project in low-middle-income countries with the goal of reducing mortality after congenital heart surgery. Three cases were described in detail with relevant images. We identified 57 cases of PVS surgery, with similar mortality to higher income countries. PVS should be recognized as a global disease. More research and collaboration are needed to understand the disease, treatments, and outcomes, and to devise treatment approaches for low resource environments.
    Matched MeSH terms: Cardiac Catheterization
  19. Md Noh MSF
    Aorta (Stamford), 2020 Oct;8(5):159-160.
    PMID: 33368104 DOI: 10.1055/s-0040-1715466
    A 22-year-old male with underlying end-stage renal failure was referred to our center for a malpositioned dialysis catheter. Imaging showed the tip of the catheter to be placed in the brachiocephalic trunk; the patient was, however, asymptomatic. Surgical removal of the malpositioned catheter followed, with no postoperative complications.
    Matched MeSH terms: Catheterization
  20. Zubair Faramir Zainul Fadziruddin, Adi Azriff Basri, Ernnie Illyani Basri
    MyJurnal
    Intravenous (IV) infusion of medical fluid is a very common procedure used as part of medical procedure treatment. It is also the best alternative medical administration route when medical administration through orally is impossible. The most common use of VAD is the short Peripheral IV Catheter (PIVC) or recognized as IV Cannula. In spite of that, even with experience used of PIVC in medical practice nowadays the rate of IV access failure is very high which is up to 69%. Intensive research studies shows the dislodgement case is one of the major contributions of PIVC failure. For some reason only a fewer cases are reported to the administration. This article seeks the awareness and risk factor regarding to the prevailing IV access failure using the PIVC. This manuscript reviewed the statistical data of PIVC dislodgement, significant of dislodgement, dislodgment cases among pediatric, medical staff factor related to PIVC dislodgement and alternative of securement device. This manuscript also discussed the needs of new securement device in order to reduce the percentage of PIVC dislodgement from occurs.
    Matched MeSH terms: Catheterization, Peripheral
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links