Displaying publications 41 - 60 of 153 in total

Abstract:
Sort:
  1. Chee, W.H., Ahmad, A.R.
    JUMMEC, 2018;21(2):59-63.
    MyJurnal
    Locked pubic symphysis is a rare form of pelvic injury that usually occurs after a lateral compression injury to
    the pelvis, where the intact pubis is trapped behind the contralateral pubis. To the best of our knowledge, there
    were 25 similar cases reported in the English literature since it was first described in 1952. We present a case
    of locked pubic symphysis with a left iliac wing fracture and a left femur shaft fracture requiring open reduction
    and internal fixation. We also reviewed previous reported cases of locked pubic symphysis and analysed the
    pattern of presentation and guide to management of such injuries. We propose a classification system for
    grading overlapping pubic symphysis that will provide a better guide to the management of such injuries.
    Matched MeSH terms: Fracture Fixation, Internal
  2. Mirzasadeghi A, Narayanan SS, Ng MH, Sanaei R, Cheng CH, Bajuri MY, et al.
    Biomed Mater Eng, 2014;24(6):2177-86.
    PMID: 25226916 DOI: 10.3233/BME-141029
    The application of bone substitutes and cements has a long standing history in augmenting fractures as a complement to routine fracture fixation techniques. Nevertheless, such use is almost always in conjunction with definite means of fracture fixation such as intramedullary pins or bone plates. The idea of using biomaterials as the primary fixation bears the possibility of simultaneous fixation and bone enhancement. Intramedullary recruitment of bone cements is suggested in this study to achieve this goal. However, as the method needs primary testings in animal models before human implementation, and since the degree of ambulation is not predictable in animals, this pilot study only evaluates the outcomes regarding the feasibility and safety of this method in the presence of primary bone fixators. A number of two sheep were used in this study. Tibial transverse osteotomies were performed in both animals followed by external skeletal fixation. The medullary canals, which have already been prepared by removing the marrow through proximal and distal drill holes, were then injected with calcium phosphate cement (CPC). The outcomes were evaluated postoperatively by standard survey radiographs, morphology, histology and biomechanical testings. Healing processes appeared uncomplicated until week four where one bone fracture recurred due to external fixator failure. The results showed 56% and 48% cortical thickening, compared to the opposite site, in the fracture site and proximal and distal diaphyses respectively. This bone augmentative effect resulted in 264% increase in bending strength of the fracture site and 148% increase of the same value in the adjacent areas of diaphyses. In conclusion, IMCO, using CPC in tibia of sheep, is safe and biocompatible with bone physiology and healing. It possibly can carry the osteopromotive effect of the CPCs to provide a sustained source of bone augmentation throughout the diaphysis. Although the results must be considered preliminary, this method has possible advantages over conventional methods of bone fixation at least in bones with compromised quality (i.e. osteoporosis and bone cysts), where rigid metal implants may jeopardize eggshell cortices.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods*
  3. Abdul-Rahman MR, Seong NK, Hee TG, Aljada ME, Reda TA, Sumin JO, et al.
    Heart Surg Forum, 2009 Jun;12(3):E184-6.
    PMID: 19546075 DOI: 10.1532/HSF98.20091016
    Various techniques of sternal stabilization via either metal plates or wires have been described. We describe an alternative technique of simple median sternotomy followed by reduction and wire fixation of the sternal fracture. The 2 patients described in this report had traumatic comminuted and displaced sternal fractures. Even though wire repair was deemed to be tedious and achieved poor approximation of the bone, we performed median sternotomy and achieved simple wire fixation with an excellent result.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods*
  4. Shanmugam R, Ernst M, Stoffel K, Fischer MF, Wahl D, Richards RG, et al.
    Clin Biomech (Bristol, Avon), 2015 Jun;30(5):405-10.
    PMID: 25846324 DOI: 10.1016/j.clinbiomech.2015.03.019
    Dorsal plating is commonly used in proximal phalanx fractures but it bears the risk of interfering with the extensor apparatus. In this study, dorsal and lateral plating fixation methods are compared to assess biomechanical differences using conventional 1.5mm non-locking plates and novel 1.3mm lateral locking plates.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods*
  5. Devnani AS
    Injury, 1997 Mar;28(2):131-3.
    PMID: 9205580
    Open reduction of the radial head and reconstruction of the annular ligament has been advocated for the Monteggia fracture dislocation in children who present more than a month after injury. Three patients with an anterior Monteggia lesion were treated by open reduction of the radial head which was held in place by a Kirschner wire passed from the humerus to the radius. No attempt was made either to repair or reconstruct the annular ligament. The patients were aged between 2 and 6 years, the delay between injury and reduction was between 6 and 8 weeks, and the length of follow up was 5 years for two patients and 1 year for the third. All three patients were free of pain, had no deformity and the radial head had not subluxated. All had nearly full flexion at the elbow. The forearm had full supination but restricted pronation.
    Matched MeSH terms: Fracture Fixation, Intramedullary/instrumentation; Fracture Fixation, Intramedullary/methods*
  6. Shamsuddin SA, Penafort R, Sharaf I
    Med J Malaysia, 2001 Dec;56 Suppl D:38-44.
    PMID: 14569765 MyJurnal
    A retrospective study was done on 56 patients treated with percutaneous pinning of displaced supracondylar fractures of the humerus in the Paediatrics Institute of Hospital Kuala Lumpur between November 1999 and October 2000, to ascertain whether there is any significance clinically in the stability of a crossed pinning medial compared with lateral pinning method. There was equal number of patients in each group (28 patients). The radiographs were evaluated for change in Baumann's angle and Lateral Humero-capitellar angle from immediate post-op until the last follow-up. The changes in the angles did not reveal any statistically significant difference in the ability to maintain reduction of the fractures. There were 3 instances of iatrogenic ulnar nerve injury in the crossed pinning group; the lateral pinning group had 1 case each of anterior interosseous nerve and radial nerve injury post operatively. No vascular injury was noted. Two cases of superficial pin tract infection were present in each group. The lateral percutaneous pinning technique of displaced supracondylar fractures of the humerus therefore offers a viable alternative to the crossed pinning group as it offers the same stability without the incipient risk of iatrogenic ulnar nerve injury.
    Matched MeSH terms: Fracture Fixation, Internal/adverse effects; Fracture Fixation, Internal/methods*
  7. Shanmugam R, Jian CYCCS, Haseeb A, Aik S
    J Orthop Surg (Hong Kong), 2018 10 3;26(3):2309499018802511.
    PMID: 30270746 DOI: 10.1177/2309499018802511
    PURPOSE: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion.

    METHOD: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion.

    RESULTS: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group.

    CONCLUSION: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.

    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods
  8. Ong CT, Choon DS, Cabrera NP, Maffulli N
    Injury, 2002 Nov;33(9):829-34.
    PMID: 12379395
    We report the results of external fixation in 29 patients treated for tibial fractures and tibial non-union using a novel multi axial external fixator (MAXX) followed prospectively until bony union. The results of treatment were classified according to the Association for the Study and Application of the Method of Ilizarov (ASAMI). Overall, 13 patients had excellent bone results; 13 had good bone results; two had fair bone results, and 1 patient had poor bone results. Regarding functional results, 21 patients had excellent results; 6 obtained good results; none had fair results, and two had poor results. Acute patients did better functionally than chronic patients. This fixator is safe and versatile, although the indications for its use are very specific.
    Matched MeSH terms: Fracture Fixation/instrumentation*; Fracture Fixation/methods
  9. Lovisetti G, Vulcano E, Bettella L, Tasarib R, Tondolo T, Sala F
    J Knee Surg, 2018 May;31(5):459-466.
    PMID: 28719943 DOI: 10.1055/s-0037-1604139
    Surgical reconstruction of bicondylar tibial fractures with external fixation relies on indirect fracture reduction that could affect anatomical restoration. The aim of the present study is to evaluate the radiographic and clinical outcomes of tibial bicondylar fractures treated with circular external fixation. A total of 20 bicondylar fractures of the proximal tibia in 20 patients treated with circular external fixation were included in the study. Two fractures were open. Mean clinical and radiographic follow-up was 37.3 months after frame removal. Angular, translation, and length deformities were assessed on nonweight-bearing anteroposterior, lateral, and two 45 degrees oblique views. The medial proximal tibia (MPTA) and posterior proximal tibia angles (PPTA) were calculated in all cases. The condylar widening was calculated in relation to the width of the femoral condyles. Joint depressions or gaps of the articular surface were identified on the four views of the knee. The modified Hospital for Special Surgery (HSS) knee scoring system was used for clinical evaluation. The MPTA was good in 18 (90%) and fair in 2 patients (10%). The PPTA was good in 13 (65%), fair in 6 (30%), and poor in 1 patient (5%). The articular reduction was good in 12 (60%) and fair in 8 patients (40%). The condylar widening was good in 15 (75%) and fair in 5 patients (25%). Mechanical axis deviation was within the normal range in 11/12 patients (91.7%). All fractures consolidated. One deep infection was successfully treated with local debridement, the mean modified HSS knee score at the latest follow-up was 90.5 (range: 67-100). Articular reconstruction and tibia alignment based on radiographic evaluation in the present study, along with functional results compare favorably with those of external and internal fixation presented in the literature.
    Matched MeSH terms: Fracture Fixation/instrumentation*; Fracture Fixation/methods
  10. Labens R, Khairuddin NH, Murray M, Jermyn K, Ahmad RS
    Vet Surg, 2019 Jan;48(1):96-104.
    PMID: 30403407 DOI: 10.1111/vsu.13123
    OBJECTIVE: To assess fracture gap reduction and stability of linear vs triangular 4.5-mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures.

    STUDY DESIGN: Experimental.

    SAMPLE POPULATION: Fourteen equine cadaver limbs/horses.

    METHODS: Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.

    RESULTS: Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear  = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded  = .003; Ploaded  

    Matched MeSH terms: Fracture Fixation/methods; Fracture Fixation/veterinary*
  11. Khoo C, Haseeb A, Ajit Singh V
    Malays Orthop J, 2014 Jul;8(2):14-21.
    PMID: 25279087 DOI: 10.5704/MOJ.1407.010
    Cannulated screw fixation is a widely accepted surgical method for management of fractures of the neck of femur especially in patients with poor premorbid conditions, minimally displaced fractures and those from a younger age group. A five year retrospective study was carried out in 53 consecutive patients between 2006 to 2010 to determine the pattern of injuries, management, outcomes and the associated predictive factors.All the patients underwent cannulated screw fixation, with 37 (69.8%) having had surgery within 24 hours and the remaining 16 (30.2%) 24 hours after the initial injury. All patients were followed up to union of fractures and complications thereafter if any. Good outcome was observed in 43 (81.1%) patients leaving only 10 (18.9%) patients with a poor outcome, of whom nine developed avascular necrosis (90%) and one non-union (10%). We found no significant relationship between the incidence of avascular necrosis and age of patient, fracture displacement, numbers of cannulated screws used, fracture reduction acceptability and anatomical location of the fracture. The time interval from injury to surgery and the presence of posterior comminution did seem to influence the rate of avascular necrosis but due to the small number of patients, was not statistically significant.We conclude that cannulated screw fixation is a viable option of treatment for fractures of the neck of femur.
    Matched MeSH terms: Fracture Fixation
  12. Anizar-Faizi A, Hisam A, Sudhagar KP, Moganadass M, Suresh C
    Malays Orthop J, 2014 Nov;8(3):1-6.
    PMID: 26401227 MyJurnal DOI: 10.5704/MOJ.1411.001
    The aim of this study was to assess the outcome of surgical treatment in displaced acetabular fractures in our local facilities. Previous studies reveal good outcome via open reduction method with achievement of congruent joint. We note that studies in this respect have not been conducted in our region. We retrospectively analyzed thirty patients with acetabular fractures who underwent open reduction and internal fixation. The data collection was performed over a 4-year period, from 2008 to 2011. The results showed 20 out of 30 patients (66.7%) had excellent/good results (Harris Hip Score equal or more than 80). Post operative complications were deep infection (6.7%), iatrogenic sciatic nerve injury (10.0%), avascular necrosis (16.7%), heterotopic ossificans (3.3%), degenerative changes in hip joint (43.3%) and loss of reduction (3.3%). In conclusion, surgical treatment of displaced acetabular fractures produces good functional outcome despite the complications.
    Matched MeSH terms: Fracture Fixation, Internal
  13. Nordin S, Zulkifli O, Faisham WI
    Med J Malaysia, 2001 Dec;56 Suppl D:12-7.
    PMID: 14569760
    We studied 60 intertrochanteric fractures of the femur fixed with Dynamic Hip Screw (DHS). There were 10 cases (16.7%) with cutting-out of device through femoral head and neck. Stable fracture pattern, postero-inferior and central position of screw in the femoral neck and head produced high percentage of good result, whereas anterior or superior position of screw produced higher incidence of cut-out. We found osteoporosis and distance of screw tip to subchondral bone to have no influence on the final outcome.
    Matched MeSH terms: Fracture Fixation, Internal/adverse effects; Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/statistics & numerical data
  14. Sath S
    Malays Orthop J, 2020 Nov;14(3):184-187.
    PMID: 33403084 DOI: 10.5704/MOJ.2011.031
    Complications in the form of esophageal injury, tracheal injury, injury to carotids, implant failure, loosening of screws, etc do occur after anterior cervical surgeries. Although intra-operative esophageal injuries are as such rare, there have been few reports of delayed esophageal perforation as well after anterior cervical surgeries. We report a very rare case of migration of missing screw from anterior cervical plate after anterior cervical corpectomy and plating, which had ultimately migrated down to colon and had to be removed via colonoscopy. Along with removal of migrated screw from colon, revision of failed anterior cervical surgery was done wherein plate and screws were removed with mesh cage left in-situ as it was snug-fit while pharyngeophageal perforation was explored and was found to be spontaneously healing, with addition of posterior Bohlman's interspinous wiring for added stability. Migration of screw from the anterior cervical plate into the colon although very rare, should be always kept in mind and its potentially serious complications. We also conclude that particular attention should be given to elderly people with poor bony quality who have high chances of implant failure, along with attention to proper cage size, screw position and proper locking of the screw to further lessen the chances of implant failure.
    Matched MeSH terms: Fracture Fixation, Internal
  15. Kongcharoensombat W, Wattananon P
    Malays Orthop J, 2018 Nov;12(3):1-5.
    PMID: 30555639 DOI: 10.5704/MOJ.1811.001
    Introduction: The anterolateral acromion approach of the shoulder is popular for minimally invasive plate osteosynthesis (MIPO) technique. However, there are literatures describing the specific risks of injury of the axillary nerve using this approach. Nevertheless, most of the studies were done with Caucasian cadavers. So, the purpose of this study was to evaluate the risk of iatrogenic axillary nerve injury from using the anterolateral shoulder approach and further investigate the location of the axillary nerve, associated with its location and arm length in the Asian population that have shorter arm length compared to the Caucasian population. Materials and Methods: Seventy-nine shoulders in fourty-two embalmed cadavers were evaluated. The bony landmarks were drawn, and a vertical straight incision was made 5cm from tip of the acromion (anterolateral approach), to the bone. The iatrogenic nerve injury status and the distance between the anterolateral edge of the acromion to the axillary nerve was measured and recorded. Results: In ten of the seventy-nine shoulders, the axillary nerve were iatrogenically injured. The average anterior distance was 6.4cm and the average arm length was 30.2cm. The anterior distance and arm length ratio was 0.2. Conclusion: Our results demonstrated that the recommended safe zone at 5cm from tip of acromion was not suitable with Asian population due to shorter arm length, compared to Caucasian population. The location of axillary nerve could be predicted by 20% of the total arm-length.
    Matched MeSH terms: Fracture Fixation, Internal
  16. Ahmad AA, Ubaidah Mustapa Kamal MA, Ruslan SR, Abdullah S, Ahmad AR
    J Shoulder Elbow Surg, 2020 Nov;29(11):2319-2325.
    PMID: 32499198 DOI: 10.1016/j.jse.2020.03.003
    BACKGROUND: Fixation of clavicle fractures has now become a more popular option as it provides better outcome compared with conservative management. Wide-awake local anesthesia no tourniquet (WALANT) has been effectively used in plating of distal radius and olecranon fractures. This paper expands the usage of WALANT into the shoulder girdle, namely plating of the clavicle that has not been described. The operation is typically performed under general anesthesia.

    METHODS: We report a case series of 16 patients who successfully underwent fixation of the clavicle under the wide-awake technique. The clavicle fractures were grouped under the AO Fracture Classification. The WALANT solution comprised 1% lidocaine, 1:100,000 epinephrine, and 10:1 sodium bicarbonate. A total of 40 mL was injected in each patient with 10 mL subcutaneously along the clavicle followed by 30 mL subperiosteally at multiple intervals and directions.

    RESULTS: The Numerical Pain Rating Score was 0 during WALANT injection and during surgery except for 2 patients with Numerical Pain Rating Scores of 1 and 2, respectively, during reduction.

    CONCLUSION: We conclude that clavicle plating under WALANT is a good alternative option of anesthesia.

    Matched MeSH terms: Fracture Fixation, Internal/adverse effects; Fracture Fixation, Internal/instrumentation; Fracture Fixation, Internal/methods*
  17. Gupta RK, Khiyani R, Majumdar KP, Potalia R
    Malays Orthop J, 2020 Jul;14(2):120-125.
    PMID: 32983386 DOI: 10.5704/MOJ.2007.021
    Introduction: To assess the results of Milch osteotomy in terms of deformity correction and functional outcome in the absence of ulnar nerve transposition.

    Material and Methods: Nine patients with cubitus valgus deformity greater than 20° with tardy ulnar nerve palsy (TUNP) operated between 2012 and 2017 were evaluated. Correction by Milch osteotomy and fixation was done in each case, without osteosynthesis of the non-union lateral condyle humerus or transposition of the ulnar nerve. At one year post-operatively, carrying angle, elbow function (Mayo Elbow Performance Score) and ulnar nerve symptoms were assessed.

    Results: The mean carrying angle pre-operatively was 30.8° on the affected side which improved to a mean of 8.3° postoperatively with an average correction of 22.5°. The mean elbow flexion pre-operatively was 129.4° which improved to 133.3° post-operatively. The mean preoperative MEP score was 76.7 which improved to a mean of 92.2 post-operatively (p < 0.01). TUNP recovered completely in all the patients.

    Conclusion: Milch osteotomy is an effective procedure for cubitus valgus deformity correction and its associated tardy ulnar nerve palsy without a decrease in elbow ROM. Correction of even severe valgus deformities without concurrent anterior transposition of the ulnar nerve is likely to improve ulnar nerve symptoms.

    Matched MeSH terms: Fracture Fixation, Internal
  18. Ong, A.H.M.
    Ann Dent, 1996;3(1):-.
    MyJurnal
    The current standard of managing facial bone fractures is the use of rigid internal fixation. This method provides good stabilization and repair for mid-face fractures such as the zygomatico-orbitalfracture. Nowadays, for the young and old, patients want not only rapid bone healing, but also good facial aesthetics after surgical treatment following maxillofacial trauma. Therefore, osteosynthesis of fractures and inconspicuous post-operative scars are considered essential. The lower eyelid approach or modified blepharoplasty provides rapid access to the infraorbital rim as well as the orbital floor, while the lateral eyebrow incision gives direct access for fixation at the fronto-zygomatic suture. Combining the Gillies' approach and a single form of rigid internal fixation, good cosmetic results and function can be achieved. Cases using the micro-plate-system for thin infraorbital bones and the miniplate- system for thicker facial bones involving zygomatico-orbital fractures are described.
    Matched MeSH terms: Fracture Fixation, Internal
  19. Zal U’yun Wan Mahmood, Norfaizal Mohamed @ Mohamad, Nik Azlin Nik Ariffin, Abdul Kadir Ishak
    MyJurnal
    An improved laboratory technique for measurement of polonium-210(
    210Po) in environmental
    samples has been developed in Radiochemistry and Environmental Laboratory (RAS), Malaysian
    Nuclear Agency. To further improve this technique, a study with the objectives to determine the
    optimum conditions for
    210Po deposition and; evaluate the accuracy and precision results for
    the determination of 2 1 0 P o in environmental samples was carried-out. Polonium-210 which
    is an alpha emitter obtained in acidic solution through total digestion and dissolution of samples
    has been efficiently plated onto one side of the silver disc in the spontaneous plating process for
    measurement of its alpha activity. The optimum conditions for deposition of 210Po were achieved
    using hydrochloric acid (HCl) media at acidity of 0.5 M with the presence of 1.0 gram hydroxyl
    ammonium chloride and the plating temperature at 90
    oC. The plating was carried out in 80 mL
    HCl solution (0.5 M) for 4 hours. The recorded recoveries obtained using 2 0 9 P o tracers in
    the CRM IAEA-385 and environmental samples were 85% – 98% whereby the efficiency of the
    new technique is a distinct advantage over the existing techniques. Therefore, optimization of
    deposition parameters is a prime importance to achieve accuracy and precision results as well as
    economy and time saving
    Matched MeSH terms: Fracture Fixation, Internal
  20. Malays Orthop J, 2011;5(2):24-27.
    MyJurnal
    The objective of this study was to assess the rate of screw cut out in elderly patients treated with the dynamic hip screw and the relationship to the Tip Apex Distance (TAD). This is a retrospective radiological evaluation of 100 cases of elderly patients with intertrochanteric fracture treated with dynamic hip screw fixation surgically treated between 1998 and 2002. The incidence of screw cut out was assessed and correlation of risk of cut out with the TAD was assessed. The rate of screw cut out was 9.0% and the average length of time to screw cut out was 3.8 months (range, 1 to 6 months) postoperatively. The incidence of screw cut out increased significantly when the TAD was 20 mm or more. The screw cut out rates were 2.9%, 20.0%, 30.8%, 50% and 100% for TAD of 20-24 mm, 25-29 mm, 30-34 mm, 35-44 mm and > 45 mm respectively. Overall, a TAD of 20mm or more was associated with a statistically significant screw cut out risk in this Malaysian population
    Matched MeSH terms: Fracture Fixation, Internal