Displaying publications 41 - 60 of 120 in total

Abstract:
Sort:
  1. Liao C, Liu F, Alomirah H, Loi VD, Mohd MA, Moon HB, et al.
    Environ Sci Technol, 2012 Jun 19;46(12):6860-6.
    PMID: 22620267 DOI: 10.1021/es301334j
    As concern regarding the toxic effects of bisphenol A (BPA) grows, BPA in many consumer products is gradually being replaced with compounds such as bisphenol S (BPS). Nevertheless, data on the occurrence of BPS in human specimens are limited. In this study, 315 urine samples, collected from the general populations in the United States, China, India, Japan, Korea, Kuwait, Malaysia, and Vietnam, were analyzed for the presence of total BPS (free plus conjugated) concentrations by high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). BPS was detected in 81% of the urine samples analyzed at concentrations ranging from below the limit of quantitation (LOQ; 0.02 ng/mL) to 21 ng/mL (geometric mean: 0.168 ng/mL). The urinary BPS concentration varied among countries, and the highest geometric mean concentration [1.18 ng/mLor 0.933 μg/g creatinine (Cre)] of BPS was found in urine samples from Japan, followed by the United States (0.299 ng/mL, 0.304 μg/g Cre), China (0.226 ng/mL, 0.223 μg/g Cre), Kuwait (0.172 ng/mL, 0.126 μg/g Cre), and Vietnam (0.160 ng/mL, 0.148 μg/g Cre). Median concentrations of BPS in urine samples from the Asian countries were 1 order of magnitude lower than the median concentrations reported earlier for BPA in the same set of samples, with the exception of samples from Japan. There were no significant differences in BPS concentrations between genders (male versus female), or among age groups (categorized as ≤ 19, 20-29, 30-39, 40-49, and ≥ 50 years), or races (Caucasian versus Asian). The daily intake (EDI) of BPS was estimated on the basis of urinary concentrations using a simple pharmacokinetic approach. The median EDI values of BPS in Japan, China, United States, Kuwait, Vietnam, Malaysia, India, and Korea were 1.67, 0.339, 0.316, 0.292, 0.217, 0.122, 0.084, and 0.023 μg/person, respectively. This is the first study to report the occurrence of BPS in human urine.
    Matched MeSH terms: Quality Control
  2. Shiesh SC, Wiedmeyer HM, Kao JT, Vasikaran SD, Lopez JB, Laboratory Management Committee for the Asian-Pacific Federation of Clinical Biochemistry
    Clin Chem, 2009 Oct;55(10):1876-80.
    PMID: 19617287 DOI: 10.1373/clinchem.2009.129726
    BACKGROUND: The correlation between hemoglobin A(1c) (Hb A(1c)) and risk for complications in diabetic patients heightens the need to measure Hb A(1c) with accuracy. We evaluated the current performance for measuring Hb A(1c) in the Asian and Pacific region by examining data submitted by laboratories participating in the Taiwan proficiency-testing program.

    METHODS: Five fresh-pooled blood samples were sent to participating laboratories twice each year. The results were evaluated against target values assigned by the National Glycohemoglobin Standardization Program network laboratories; a passing criterion of +/-7% of the target value was used. Measurement uncertainty at Hb A(1c) concentrations of 7.0% and 8.0% were determined.

    RESULTS: A total of 276 laboratories from 11 countries took part in the Hb A(1c) survey. At the Hb A(1c) concentrations tested method-specific interlaboratory imprecision (CVs) were 1.1%-13.9% in 2005, 1.3%-10.1% in 2006, 1.2%-8.2% in 2007, and 1.1%-6.1% in 2008. Differences between target values and median values from the commonly used methods ranged from -0.24% to 0.22% Hb A(1c) in 2008. In 2005 83% of laboratories passed the survey, and in 2008 93% passed. At 7.0% Hb A(1c), measurement uncertainty was on average 0.49% Hb A(1c).

    CONCLUSIONS: The use of accuracy-based proficiency testing with stringent quality criteria has improved the performance of Hb A(1c) testing in the Asian and Pacific laboratories during the 4 years of assessment.

    Matched MeSH terms: Quality Control
  3. Tan TC, AlKarkhi AF, Easa AM
    Food Chem, 2012 Oct 15;134(4):2430-6.
    PMID: 23442706 DOI: 10.1016/j.foodchem.2012.04.049
    The addition of ribose to bovine or porcine gelatine solutions followed by heating at 95 °C yielded brown solutions with different pH, colour (CIE L(*) and b(*)) and absorbance (A(420*) values. These differences were used for gelatine powder identification, differentiation and quality control. Differentiation analysis of the Maillard reaction parameters was conducted using cluster analysis (CA) and confidence intervals (CI). The potential use of the method as a quality control procedure was evaluated by using statistical process control (SPC). CA revealed that the two types of gelatine could be classified into two different groups. CI (95% confidence) revealed that the absorbance and colour values could be used as indicators for differentiation between the two types of gelatine because the intervals between the Maillard reaction parameters of the samples were far apart. The methodology demonstrated good reproducibility because it behaved predictably based on the X¯-S charts generated from the SPC charts.
    Matched MeSH terms: Quality Control
  4. Omar A, Yusoff MF, Hiong TG, Aris T, Morton J, Pujari S
    Int J Public Health Res, 2013;3(2):297-305.
    PMID: 26451348 MyJurnal
    INTRODUCTION: Malaysia participated in the second phase of the Global Adult Tobacco Survey (GATS) in 2011. GATS, a new component of the Global Tobacco Surveillance System, is a nationally representative household survey of adults 15 years old or above. The objectives of GATS Malaysia were to (i) systematically monitor tobacco use among adults and track key indicators of tobacco control and (ii) track the implementation of some of the Framework Convention of Tobacco Control (FCTC)-recommended demand related policies.
    METHODS: GATS Malaysia 2011 was a nationwide cross-sectional survey using multistage stratified sampling to select 5112 nationally representative households. One individual aged 15 years or older was randomly chosen from each selected household and interviewed using handheld device. GATS Core Questionnaire with optional questions was pre-tested and uploaded into handheld devices after repeated quality control processes. Data collectors were trained through a centralized training. Manuals and picture book were prepared to aid in the training of data collectors and during data collection. Field-level data were aggregated on a daily basis and analysed twice a week. Quality controls were instituted to ensure collection of high quality data. Sample weighting and analysis were conducted with the assistance of researchers from the Centers for Disease Control and Prevention, Atlanta, USA.
    RESULTS: GATS Malaysia received a total response rate of 85.3% from 5112 adults surveyed. Majority of the respondents were 25-44 years old and Malays.
    CONCLUSIONS: The robust methodology used in the GATS Malaysia provides national estimates for tobacco used classified by socio-demographic characteristics and reliable data on various dimensions of tobacco control.
    Study name: Global Adults Tobacco Survey (GATS-2011)
    Matched MeSH terms: Quality Control
  5. Brandon-Mong GJ, Gan HM, Sing KW, Lee PS, Lim PE, Wilson JJ
    Bull. Entomol. Res., 2015 Dec;105(6):717-27.
    PMID: 26344799 DOI: 10.1017/S0007485315000681
    Metabarcoding, the coupling of DNA-based species identification and high-throughput sequencing, offers enormous promise for arthropod biodiversity studies but factors such as cost, speed and ease-of-use of bioinformatic pipelines, crucial for making the leapt from demonstration studies to a real-world application, have not yet been adequately addressed. Here, four published and one newly designed primer sets were tested across a diverse set of 80 arthropod species, representing 11 orders, to establish optimal protocols for Illumina-based metabarcoding of tropical Malaise trap samples. Two primer sets which showed the highest amplification success with individual specimen polymerase chain reaction (PCR, 98%) were used for bulk PCR and Illumina MiSeq sequencing. The sequencing outputs were subjected to both manual and simple metagenomics quality control and filtering pipelines. We obtained acceptable detection rates after bulk PCR and high-throughput sequencing (80-90% of input species) but analyses were complicated by putative heteroplasmic sequences and contamination. The manual pipeline produced similar or better outputs to the simple metagenomics pipeline (1.4 compared with 0.5 expected:unexpected Operational Taxonomic Units). Our study suggests that metabarcoding is slowly becoming as cheap, fast and easy as conventional DNA barcoding, and that Malaise trap metabarcoding may soon fulfill its potential, providing a thermometer for biodiversity.
    Matched MeSH terms: Quality Control
  6. Zaini NN, Osman R, Juahir H, Saim N
    Molecules, 2016 Apr 30;21(5).
    PMID: 27144555 DOI: 10.3390/molecules21050583
    E. longifolia is attracting interest due to its pharmacological properties and pro-vitality effects. In this study, an online SPE-LC approach using polystyrene divinyl benzene (PSDVB) and C18 columns was developed in obtaining chromatographic fingerprints of E. longifolia. E. longifolia root samples were extracted using pressurized liquid extraction (PLE) technique prior to online SPE-LC. The effects of mobile phase compositions and column switching time on the chromatographic fingerprint were optimized. Validation of the developed method was studied based on eurycomanone. Linearity was in the range of 5 to 50 µg∙mL(-1) (r² = 0.997) with 3.2% relative standard deviation of peak area. The developed method was used to analyze 14 E. longifolia root samples and 10 products (capsules). Selected chemometric techniques: cluster analysis (CA), discriminant analysis (DA), and principal component analysis (PCA) were applied to the fingerprint datasets of 37 selected peaks to evaluate the ability of the chromatographic fingerprint in classifying quality of E. longifolia. Three groups were obtained using CA. DA yielded 100% correlation coefficient with 19 discriminant compounds. Using PCA, E. longifolia root samples were clearly discriminated from the products. This study showed that the developed online SPE-LC method was able to provide comprehensive evaluation of E. longifolia samples for quality control purposes.
    Matched MeSH terms: Quality Control
  7. Hassan H, Abu Bakar S, Halim KN, Idris J, Nordin AJ
    Curr Radiopharm, 2016;9(2):128-36.
    PMID: 26013570
    BACKGROUND AND OBJECTIVE: Prostate cancer continues to be the most prevalent cancer in men in Malaysia. As time progresses, the prospect of PET imaging modality in diagnosis of prostate cancer is promising, with on-going improvement on novel tracers. Among all tracers, 18F-Fluorocholine is reported to be a reputable tracer and reliable diagnostic technique for prostate imaging. Nonetheless, only 18F-Fluorodeoxyglucose (18F-FDG) is available and used in most oncology cases in Malaysia. With a small scale GMP-based radiopharmaceuticals laboratory set-up, initial efforts have been taken to put Malaysia on 18F-Fluorocholine map. This article presents a convenient, efficient and reliable method for quality control analysis of 18F-Fluorocholine. Besides, the aim of this research work is to assist local GMP radiopharmaceuticals laboratories and local authority in Malaysia for quality control analysis of 18F-Fluorocholine guideline.

    METHODS: In this study, prior to synthesis, quality control analysis method for 18F-Fluorocholine was developed and validated, by adapting the equipment set-up used in 18F-Fluorodeoxyglucose (18FFDG) routine production. Quality control on the 18F-Fluorocholine was performed by means of pH, radionuclidic identity, radio-high performance liquid chromatography equipped with ultraviolet, radio- thin layer chromatography, gas chromatography and filter integrity test.

    RESULTS: Post-synthesis; the pH of 18F-Fluorocholine was 6.42 ± 0.04, with half-life of 109.5 minutes (n = 12). The radiochemical purity was consistently higher than 99%, both in radio-high performance liquid chromatography equipped with ultraviolet (r-HPLC; SCX column, 0.25 M NaH2PO4: acetonitrile) and radio-thin layer chromatography method (r-TLC). The calculated relative retention time (RRT) in r-HPLC was 1.02, whereas the retention factor (Rf) in r-TLC was 0.64. Potential impurities from 18F-Fluorocholine synthesis such as ethanol, acetonitrile, dimethylethanolamine and dibromomethane were determined in gas chromatography. Using our parameters, (capillary column: DB-200, 30 m x 0.53 mm x 1 um) and oven temperature of 35°C (isothermal), all compounds were well resolved and eluted within 3 minutes. Level of ethanol and acetonitrile in 18F-Fluorocholine were detected below threshold limit; less than 5 mg/ml and 0.41 mg/ml respectively. Meanwhile, dimethylethanolamine and dibromomethane were undetectable.

    CONCLUSION: A convenient, efficient and reliable quality control analysis work-up procedure for 18FFluorocholine has been established and validated to comply all the release criteria. The convenient method of quality control analysis may provide a guideline to local GMP radiopharmaceutical laboratories to start producing 18F-Fluorocholine as a tracer for prostate cancer imaging.

    Matched MeSH terms: Quality Control
  8. Petchi RR, Parasuraman S, Vijaya C, Gopala Krishna SV, Kumar MK
    J Basic Clin Pharm, 2015 Jun;6(3):77-83.
    PMID: 26229343 DOI: 10.4103/0976-0105.160738
    OBJECTIVES:
    To formulate a polyherbal formulation and evaluate its antiarthritic activity against Freund's complete adjuvant induced arthritis in Female Wistar rats.

    MATERIALS AND METHODS:
    Glycosmis pentaphylla, Tridax procumbens, and Mangifera indica are well-known plants available throughout India and they are commonly used for the treatment of various diseases including arthritis. The polyherbal formulation was formulated using the ethanol extracts of the stem bark of G. pentaphylla , whole plant of T. procumbens, and leaves of M. indica. The polyherbal formulation contains the ethanol extracts of G. pentaphylla, T. procumbens, and M. indica in the ratio of 2:2:1. The quality of the finished product was evaluated as per the World Health Organization's guidelines for the quality control of herbal materials. Arthritis was induced in female Wistar rats using Freund's complete adjuvant (FCA), and the antiarthritic effect of polyherbal formulation was studied at doses of 250 and 500 mg/kg. The effects were compared with those of indomethacin (10 mg/kg). At the end of the study, blood samples were collected for biochemical and hematological analysis. The radiological examination was carried out before terminating the study.

    RESULTS:
    Polyherbal formulation showed significant antiarthritic activity at 250 and 500 mg/kg, respectively, and this effect was comparable with that of indomethacin. The antiarthritic activity of polyherbal formulation is supported by biochemical and hematological analysis.

    CONCLUSION:
    The polyherbal formulation showed signinicant antiarthritic activity against FCA-induced arthritis in female Wistar rats.

    KEYWORDS:
    Arthritis; Fingerprint analysis; Glycosmis pentaphylla; Mangifera indica; Tridax procumbens
    Matched MeSH terms: Quality Control
  9. Mohamed M, Stednick JD, Smith FM
    Water Sci Technol, 2002;46(9):47-54.
    PMID: 12448451
    Some of the many tools used for watershed management are mathematical and computer models for wasteload allocations. QUAL2E is one of the most popular water quality models used for such purposes. The question arises as to whether the model is applicable in a different climate such as that in the tropics. In this study, QUAL2E was used to model Sg. Selangor River in Malaysia using the predictive equations for reaeration coefficient (k2) within the model and the measured reaeration coefficients for the river. The study results indicated that use of the reaeration coefficient (k2) measured at Sg. Selangor River did give the lowest standard error (SE) for the simulation of water quality during the 7Q10 low-flow period which is considered as the worst scene scenario in water quality modeling. But during calibration and validation using actual low-flow discharge data, the measured reaeration coefficients did not give the lowest standard error (SE). In conclusion, the results indicated that QUAL2E is applicable in tropical rivers when used with the modeled river parameters (i.e. hydraulic parameters, meteorological conditions etc.). Measured reaeration coefficients produced good results and several predictive equations also produced comparatively good results.
    Matched MeSH terms: Quality Control
  10. Bradley DA, Wong CS, Ng KH
    Appl Radiat Isot, 2000 9 26;53(4-5):691-7.
    PMID: 11003508
    For broad-beam soft X-ray sources, assessment of the quality of image produced by such units is made complex by the low penetration capabilities of the radiation. In the present study we have tested the utility of several types of test tool, some of which have been fabricated by us, as part of an effort to evaluate several key image defining parameters. These include the film characteristic, focal-spot size, image resolution and detail detectability. The two sources of X-rays used in present studies were the University of Malaya flash X-ray device (UMFX1) and a more conventional soft X-ray tube (Softex, Tokyo), the latter operating at peak accelerating potentials of 20 kVp. We have established, for thin objects, that both systems produce images of comparable quality and, in particular, objects can be resolved down to better than 45 microm.
    Matched MeSH terms: Quality Control
  11. Halim N, Kuntom A, Shinde R, Banerjee K
    J AOAC Int, 2020 Sep 01;103(5):1237-1242.
    PMID: 33241391 DOI: 10.1093/jaoacint/qsaa041
    BACKGROUND: Indaziflam (IND) is a herbicide that is used in palm oil plantations for broad spectrum management of weeds. Until now, no validated method has been available for residue estimation of this herbicide in palm oil products.

    OBJECTIVE: In this study, we report a rapid method for the residue analysis of IND and its metabolites, viz., IND-carboxylic acid, diaminotriazine, and triazine indanone in a wide range of palm oil matrices using liquid chromatography-tandem mass spectrometry (LC-MS/MS).

    METHOD: The optimized sample preparation workflows included two options: (1) acetonitrile extraction (QuEChERS workflow), followed by freezing at -80°C and (2) acetonitrile extraction, followed by cleanup through a C18 solid phase extraction (SPE) cartridge. The optimized LC runtime was 7 min. All these analytes were estimated by LC-MS/MS multiple reaction monitoring.

    RESULTS: Both sample preparation methods provided similar method performance and acceptable results. The limit of quantification (LOQ) of IND, IND-carboxylic acid, and triazine indanone was 0.001 mg/kg. For diaminotriazine, the LOQ was 0.005 mg/kg. The method accuracy and precision complied with the SANTE/12682/2019 guidelines of analytical quality control.

    CONCLUSIONS: The potentiality of the method lies in a high throughput analysis of IND and its metabolites in a single chromatographic run with high selectivity and sensitivity. Considering its fit-for-purpose performance, the method can be implemented in regulatory testing of IND residues in a wide range of palm oil matrices that are consumed and traded worldwide.

    HIGHLIGHTS: This work has provided a validated method for simultaneous residue analysis of indaziflam and its metabolites in crude palm oil and its derived matrices with high sensitivity, selectivity, and throughput.

    Matched MeSH terms: Quality Control
  12. Lasekan O, Hussein FK
    Chem Cent J, 2018 Dec 19;12(1):140.
    PMID: 30569201 DOI: 10.1186/s13065-018-0505-3
    BACKGROUND: Pineapple is highly relished for its attractive sweet flavour and it is widely consumed in both fresh and canned forms. Pineapple flavour is a blend of a number of volatile and non-volatile compounds that are present in small amounts and in complex mixtures. The aroma compounds composition may be used for purposes of quality control as well as for authentication and classification of pineapple varieties.

    RESULTS: The key volatile compounds and aroma profile of six pineapple varieties grown in Malaysia were investigated by gas chromatography-olfactometry (GC-O), gas-chromatography-mass spectrometry and qualitative descriptive sensory analysis. A total of 59 compounds were determined by GC-O and aroma extract dilution analysis. Among these compounds, methyl-2-methylbutanoate, methyl hexanoate, methyl-3-(methylthiol)-propanoate, methyl octanoate, 2,5-dimethyl-4-methoxy-3(2H)-furanone, δ-octalactone, 2-methoxy-4-vinyl phenol, and δ-undecalactone contributed greatly to the aroma quality of the pineapple varieties, due to their high flavour dilution factor. The aroma of the pineapples was described by seven sensory terms as sweet, floral, fruity, fresh, green, woody and apple-like.

    CONCLUSION: Inter-relationship between the aroma-active compounds and the pineapples revealed that 'Moris' and 'MD2' covaried majorly with the fruity esters, and the other varieties correlated with lesser numbers of the fruity esters. Hierarchical cluster analysis (HCA) was used to establish similarities among the pineapples and the results revealed three main groups of pineapples.

    Matched MeSH terms: Quality Control
  13. Norsuzilawati Abdullah, Noor Hamizah Mohd Hassan, Mohd Muhaimin Kambali
    Q Bulletin, 2019;1(28):18-25.
    MyJurnal
    The platelet concentrates (PCs) is used for the treatment and prevention of bleeding in patients with reduced platelet number or function. The prepared platelet concentrates (PCs) must meet the specified quality control (QC) test standards. PCs that do not meet QC standards will reduce the efficacy of patient care and increase the need of repeated PC transfusion. According to the standards, at least 75% PCs tested should contain more than 60 x 109 per platelet count units. Hence, the objective of this study was to increase the percentage of PCs that meet the platelet count standard to more or equal to 75%.
    A cross sectional study was conducted from May 2015 to March 2016. Data were collected and analysed through monthly PCs QC test results. A retrospective QC data review in March and April 2015 showed only 30% PCs achieved the platelet count standard for QC tests. Intervention package was implemented to tackle the identified risk factors that lead to platelet count problems that do not meet the standards.
    The post remedial results showed an increase to 90% of PCs that meet platelet count standards in January to February 2016. The study also found that the rate of platelet count increment in patients after PCs transfusion increased from 5 x 109 per ml to 9 x 109 per ml after the study. Additionally, the repeated PC transfusion rate decreased from 22% to 18%. Achievements were successfully maintained after the study which was 89% in March to April 2017. Continuous monitoring need to be carried out to ensure the achievement remains in compliance with the established standards. This quality improvement method has facilitated successful platelet transfusion to patient by improving the quality and performance of PCs. The improvement strategies of this study have the potential to be implemented at other blood collection centers in order to improve the quality of healthcare services.
    Matched MeSH terms: Quality Control
  14. Suraiami, M., Mohd Fairulnizal, M.N., Norhayati, M.K., Zaiton, A., Norliza, A.H., Wan Syuriahti, W.Z., et al.
    Malays J Nutr, 2014;20(3):417-427.
    MyJurnal
    Introduction: This study aimed to determine the nutrient content of cornflakes and muesli, ready-to-eat cereal products available in the Malaysian market. Cornflakes and muesli were chosen due to their popularity as a breakfast meal especially in urban areas. Methods: A total of six brands each for cornflakes and muesli were purchased from supermarkets in the Klang Valley using stratified random sampling. All samples were analysed using AOAC official methods of analysis. The validity of the test data was monitored with the application of internal quality controls in line with the requirements of ISO 17025. Results: Proximate analysis revealed significantly higher mean levels of carbohydrate (86.94 ± 0.59 mg/lOOg), minerals such as iron (8.48±1.72 mg/lOOg) and sodium (674.83±102.99 g/lOOg), B3 as niacinamide (25.87 ± 6.14 g/lOOg) and sucrose (5.10 ± 0.90 mg/lOOg) in cornflakes than in muesli. However, muesli contained significantly more mean moisture (10.23 ± 0.72 mg/lOOg), protein (10.07 ± 0.79 mg/lOOg), total dietary fibre (12.49 ± 1.44 mg/lOOg), magnesium (113.22 ± 7.93 mg/lOOg), zinc (1.65 ± 0.16 mg/lOOg), copper (0.25 ± 0.02 mg/lOOg), total sugar (18.75 ± 2.05 mg/lOOg), glucose (7.70±1.77 mg/lOOg) and fructose (8.68±1.76 mg/lOOg) than cornflakes. Most of the fatty acids analysed were not detected or of low value in both the cereal products. Conclusion: The nutrient analysis of cornflakes and muesli suggests that both ready-to-eat cereals are nutritionally good choice as breakfast for consumers as it provides carbohydrate, minerals, fibre and vitamins. The data provides additional information to the Malaysian Food Composition Database.
    Matched MeSH terms: Quality Control
  15. Lakshmanan S, Yung YL
    PMID: 33596165 DOI: 10.1080/19440049.2020.1842516
    Chloride reduction in crude palm oil (CPO) of greater than 80% was achieved with water washing conducted at 90°C. Inorganic chloride content in CPO was largely removed through washing, with no significant reduction in the organic chloride. Phosphorous content of CPO reduced by 20%, while trace elements such as calcium, magnesium and iron were also reduced in the washing operation. The 3-MCPDE formed in the refined, bleached and deodorised palm oil displayed (RBDPO) a linear relationship with the chloride level in washed CPO, which could be represented by the equation y = 0.91x, where y is 3-MCPDE and x represents the chloride in RBDPO refined from washed CPO. In plant scale trials using 5% water at 90°C, mild acidification of the wash water at 0.05% reduced chloride by average 76% in washed CPO. Utilising selected bleaching earths, controlled wash water temperature and wash water volume produced low chloride levels in RBDPO. Chloride content less than 1.4 mg kg-1 in plant RBDPO production was achieved, through physical refining of washed CPO containing less than 2 mg kg-1 chloride and would correspond to 3-MCPDE levels of 1.25 mg kg-1 in RBDPO. The 3-MCPDE reduced further to 1.1 mg kg-1 as the chloride level of washed CPO decreased below 1.8 mg kg-1. Chloride has been shown to facilitate the 3-MCPDE formation and its removal in lab scale washing study has yielded lower 3-MCPDE levels formed in RBDPO. In actual plant operations using washed CPO, 3-MCPDE levels below 1.25 mg kg-1 were achieved consistently in RBDPO.
    Matched MeSH terms: Quality Control
  16. Saad B, Zin ZM, Jab MS, Rahman IA, Saleh MI, Mahsufi S
    Anal Sci, 2005 May;21(5):521-4.
    PMID: 15913140
    Poly (vinyl chloride) membrane electrodes that responded selectively towards the antimalarial drug chloroquine are described. The electrodes were based on the use of the lipophilic potassium tetrakis(4-chlorophenyl)borate as ion-exchanger and bis(2-ethylhexyl)adipate (BEHA), or trioctylphosphate (TOP) or dioctylphenylphosphonate (DOPP) as plasticizing solvent mediator. All electrodes produced good quality characteristics such as Nernstian- and rapid responses, and are minimally interfered with by the alkali and alkaline earth metal ions tested. The membranes were next applied to a flow-through device, enabling it to function as flow-injection analysis (FIA) detector. The performance of the sensor after undergoing the FIA optimization was further evaluated for its selectivity characteristics and lifetime. Results for the determination of chloroquine in synthetic samples that contained common tablet excipients such as glucose, starch, and cellulose, and other foreign species such as cations, citric acid or lactic acid were generally satisfactory. The sensor was also successfully used for the determination of the active ingredients in mock tablets, synthetic fluids and biological fluids. The sensor was applied for the determination of active ingredients and the dissolution profile of commercial tablets was also established.
    Matched MeSH terms: Quality Control
  17. Lau S, Ng KH, Abdul Aziz YF
    Br J Radiol, 2016 Oct;89(1066):20160258.
    PMID: 27452264 DOI: 10.1259/bjr.20160258
    OBJECTIVE: To investigate the sensitivity and robustness of a volumetric breast density (VBD) measurement system to errors in the imaging physics parameters including compressed breast thickness (CBT), tube voltage (kVp), filter thickness, tube current-exposure time product (mAs), detector gain, detector offset and image noise.

    METHODS: 3317 raw digital mammograms were processed with Volpara(®) (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images.

    RESULTS: Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p control is essential to keep the parameter errors within reasonable bounds. Volpara appears robust within those bounds, albeit for more advanced applications such as tracking density change over time, it remains to be seen how accurate the measures need to be.

    Matched MeSH terms: Quality Control
  18. Siong, Wee Boon, Ebihara, Mitsuru
    MyJurnal
    Prompt gamma-ray analysis (PGA) and instrumental neutron activation analysis (INAA) are essential for the study of rare samples such as meteorites because of non-destructivity and relatively being free from contaminations. The objective of this research is to utilize PGA and INAA techniques for comparative study and apply them to meteorite analyses. In this study, 11 meteorite samples received from the Meteorite Working Group of NASA were analyzed. The Allende meteorite powder was included as quality control material. Results from PGA and INAA for Allende showed in good agreement with literature values, signifying the reliabilities of these two methods. Elements Al, Ca, Mg, Mn, Na and Ti were determined by both methods and their results are compared. Comparison of PGA and INAA data using linear regression analysis showed correlations coefficients r2 > 0.90 for Al, Ca, Mn and Ti, 0.85 for Mg, and 0.38 for Na. The PGA results for Na using 472 keV were less accurate due to the interference from the broad B peak. Therefore, Na results from INAA method are preferred. For other elements (Al, Ca, Mg, Mn and Ti), PGA and INAA results can be used as cross-reference for consistency. The PGA and INAA techniques have been applied to meteorite samples and results are comparable to literature values compiled from previously analyzed meteorites. In summary, both PGA and INAA methods give reasonably good agreement and are indispensable in the study of meteorites.
    Matched MeSH terms: Quality Control
  19. Sekaran AS
    Med J Malaysia, 1974 Dec;29(2):97-102.
    PMID: 4282408
    Matched MeSH terms: Quality Control
  20. Abbas, F.M.A., Foroogh, B., Liong, M.T., Azhar, M.E.
    MyJurnal
    Four types of soft dates (SD), three types of semi-dried dates (SDD) and one type of dried dates (DD) were used in this study. The antioxidant activities were assessed using TEAC method (ABTS assay) and the ferric reducing/antioxidant power method (FRAP assay), while total phenolic content (TPC) and total flavonoid content (TFC) were measured using Folin-Ciocalteau and aluminum chloride colorimetric methods. Multivariate analysis of variance (MANOVA), discriminant analysis (DA) and principal component analysis (PCA) were used to analyze the data. MANOVA showed a strong significant difference between the eight types of dates. DA identified the relative contribution of each parameter in distinguishing the dates. DA also identified two functions responsible for discriminating the dates and showed the difference between different types of dates. The first function distinguished DD from other types of dates, whilst the second function discriminated SD and SDD, affording 100% correct assignation. PCA identified only one component responsible for explaining 98.85% of the total variance in antioxidant data. It is suggested that the TEAC method and the quantitative determination of TPC and TFC was suitable for differentiation of dates and quality control.
    Matched MeSH terms: Quality Control
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links