Displaying publications 61 - 80 of 137 in total

Abstract:
Sort:
  1. Taheri S, Abdullah TL, Karimi E, Oskoueian E, Ebrahimi M
    Int J Mol Sci, 2014;15(7):13077-90.
    PMID: 25056545 DOI: 10.3390/ijms150713077
    The present study was conducted in order to assess the effect of various doses of acute gamma irradiation (0, 10, 15, and 20 Gy) on the improvement of bioactive compounds and their antioxidant properties of Curcuma alismatifolia var. Sweet pink. The high performance liquid chromatography (HPLC) and gas chromatography (GC) analysis uncovered that various types of phenolic, flavonoid compounds, and fatty acids gradually altered in response to radiation doses. On the other hand, antioxidant activities determined by 1,1-Diphenyl-2-picryl-hydrazyl (DPPH), ferric reduction, antioxidant power (FRAP), and 2,2-azino-bis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) radical scavenging assay showed a higher irradiation level significantly increased the antioxidant properties. This study revealed an efficient effect of varying levels of gamma radiation, based on the pharmaceutical demand to enhance the accumulation and distribution of bioactive compounds such as phenolic and flavonoid compounds, fatty acids, as well as their antioxidant activities in the leaves of C. alismatifolia var. Sweet pink.
    Matched MeSH terms: Chromatography, Gas
  2. Sanagi MM, Nasir Z, Ling SL, Hermawan D, Ibrahim WA, Naim AA
    J AOAC Int, 2010 10 7;93(4):1322-30.
    PMID: 20922968
    Linearity assessment as required in method validation has always been subject to different interpretations and definitions by various guidelines and protocols. However, there are very limited applicable implementation procedures that can be followed by a laboratory chemist in assessing linearity. Thus, this work proposes a simple method for linearity assessment in method validation by a regression analysis that covers experimental design, estimation of the parameters, outlier treatment, and evaluation of the assumptions according to the International Union of Pure and Applied Chemistry guidelines. The suitability of this procedure was demonstrated by its application to an in-house validation for the determination of plasticizers in plastic food packaging by GC.
    Matched MeSH terms: Chromatography, Gas/methods*
  3. Sanagi MM, Ling SL, Nasir Z, Hermawan D, Ibrahim WA, Abu Naim A
    J AOAC Int, 2010 2 20;92(6):1833-8.
    PMID: 20166602
    LOD and LOQ are two important performance characteristics in method validation. This work compares three methods based on the International Conference on Harmonization and EURACHEM guidelines, namely, signal-to-noise, blank determination, and linear regression, to estimate the LOD and LOQ for volatile organic compounds (VOCs) by experimental methodology using GC. Five VOCs, toluene, ethylbenzene, isopropylbenzene, n-propylbenzene, and styrene, were chosen for the experimental study. The results indicated that the estimated LODs and LOQs were not equivalent and could vary by a factor of 5 to 6 for the different methods. It is, therefore, essential to have a clearly described procedure for estimating the LOD and LOQ during method validation to allow interlaboratory comparisons.
    Matched MeSH terms: Chromatography, Gas
  4. Mohd Ali, A., Jahidin, A.H., Abdul Wahab, I., Mohsin, H.F., Mizaton, H.H.
    MyJurnal
    In this study, the unprecedented extraction of the Vitex pouch was performed. The compounds from
    methanolic and chloroform extracts were isolated by using thin layer chromatography (TLC). The
    compound of interest was investigated by using 1H-Nuclear Magnetic Resonance (NMR, 500 MHz)
    spectroscopy. From the NMR spectral examination, the compound from the methanolic extract was
    suggested as glucononitol. Indeed, there are some parameters that could enhance the attainment of this
    research, which include high performance liquid chromatographic supplies. Nevertheless, more
    information and understanding on the pharmaceutical and chemical analysis of the Vitex species were
    obtained. To sum up, it is anticipated that incoming research with advanced technology for this
    natural product could be explored in the future.
    Matched MeSH terms: Chromatography, Gas
  5. Lo SK, Baharin BS, Tan CP, Lai OM
    J Chromatogr Sci, 2004 Mar;42(3):145-54.
    PMID: 15023251
    Separation of 1,2(2,3)- and 1,3-positional isomers of diacylglycerols (DAG) from vegetable oils by reversed-phase high-performance liquid chromatography (RP-HPLC) is investigated. The method is based on isocratic elution using 100% acetonitrile and UV detection at 205 nm. The following elution order of DAG molecular species is identified: 1,3-dilinolein < 1,2-dilinolein < 1,3-dimyristin < 1-oleoyl-3-linoleoyl-glycerol < 1,2-dimyristoyl-rac-glycerol < 1(2)-oleoyl-2(3)-linoleoyl-glycerol < 1-linolenoyl-3-stearoyl-glycerol < 1(2)-linolenoyl-2(3)-stearoyl-glycerol < 1,3-diolein < 1-palmitoyl-3-oleoyl-glycerol < 1,2-dioleoyl-sn-glycerol < 1(2)-palmitoyl-2(3)-oleoyl-glycerol < 1-linoleoyl-3-stearoyl-glycerol < 1,3-dipalmitin < 1(2)-linoleoyl-2(3)-stearoyl-glycerol < 1-oleoyl-3-stearoyl-glycerol < 1,2-dipalmitoyl-rac-glycerol < 1-palmitoyl-3-stearoyl-sn-glycerol < 1,3-distearin < 1,2-distearoyl-rac-glycerol. Linearity is observed over three orders of magnitude. Limits of detection and quantitation range 0.2-0.7 microg/mL for 1,3-dilinolein to 0.6-1.9 microg/mL for 1,2-dioleoyl-sn-glycerol, respectively. Precision and accuracy of the method are also demonstrated. The method is developed to separate mixtures of DAG molecular species produced from edible oils.
    Matched MeSH terms: Chromatography, Gas
  6. Abboud AS, Sanagi MM, Ibrahim WAW, Keyon ASA, Aboul-Enein HY
    J Chromatogr Sci, 2018 Feb 01;56(2):177-186.
    PMID: 29186451 DOI: 10.1093/chromsci/bmx095
    In this study, caged calcium alginate-caged multiwalled carbon nanotubes dispersive microsolid phase extraction was described for the first time for the extraction of polycyclic aromatic hydrocarbons (PAHs) from water samples prior to gas chromatographic analysis. Fluorene, phenanthrene and fluoranthene were selected as model compounds. The caged calcium alginate-caged multiwalled carbon nanotubes was characterized by Fourier transform infrared spectroscopy, scanning electron microscopy and thermal gravimetry analyses. The effective parameters namely desorption solvent, solvent volume, extraction time, desorption time, the mass of adsorbent and sample volume were optimized. Under the optimum extraction conditions, the developed method showed good linearity in the range of 0.5-50 ng mL-1 (R2 ≥ 0.996), low limits of detection and quantification (0.42-0.22 ng mL-1) (0.73-1.38 ng mL-1) respectively, good relative recoveries (71.2-104.2%) and reproducibility (RSD 1.8-12.4%, n = 3) for the studied PAHs in water sample. With high enrichment factor (1,000), short extraction time (<30 min), low amounts of adsorbent (100 mg) and low amounts of solvent (0.1 mol) have proven that the microsolid phase extraction method based on calcium alginate-caged multiwalled carbon nanotubes are environmentally friendly and convenient extraction method to use as an alternative adsorbent in the simultaneous preconcentration of PAHs from environmental water samples.
    Matched MeSH terms: Chromatography, Gas/methods*
  7. Sharif Z, Man YB, Hamid NS, Keat CC
    J Chromatogr A, 2006 Sep 15;1127(1-2):254-61.
    PMID: 16857206
    A method to determine six organochlorine and three pyrethroid pesticides in grape, orange, tomato, carrot and green mustard based on solvent extraction followed by solid phase extraction (SPE) clean-up is described. The pesticides were spiked into the sample prior to analysis, extracted with ethyl acetate, evaporated and reconstituted with a solvent mixture of acetone:n-hexane (3:7). Three different sorbents (Strong Anion Exchanger/Primary Secondary Amine (SAX/PSA), Florisil and C18) were used for the clean-up step. Pesticides were eluted with 5mL of acetone:n-hexane (3:7, v/v) and determined by gas chromatography and electron-capture detection (GC-ECD). SAX/PSA was the sorbent, which provided chromatograms with less interference and the mean recoveries obtained were within 70-120% except for captafol. The captafol recoveries for grape were within acceptable range with C18 clean-up column.
    Matched MeSH terms: Chromatography, Gas/instrumentation; Chromatography, Gas/methods*
  8. Rezvani-Eivari M, Amiri A, Baghayeri M, Ghaemi F
    J Chromatogr A, 2016 Aug 16.
    PMID: 27578405 DOI: 10.1016/j.chroma.2016.08.034
    The application of magnetized graphene (G) layers synthesized on the carbon nanofibers (CNFs) (m-G/CNF) was investigated as novel adsorbent for the magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) in water samples followed by gas chromatography-flame ionization detector (GC-FID). Six important parameters, affecting the extraction efficiency of PAHs, including: amount of adsorbent, adsorption and desorption times, type and volume of the eluent solvent and salt content of the sample were evaluated. The optimum extraction conditions were obtained as: 5min for extraction time, 20mg for sorbent amount, dichloromethane as desorption solvent, 1mL for desorption solvent volume, 5min for desorption time and 15% (w/v) for NaCl concentration. Good performance data were obtained at the optimized conditions. The calibration curves were linear over the concentration ranges from 0.012 to 100ngmL(-1) with correlation coefficients (r) between 0.9950 and 0.9967 for all the analytes. The limits of detection (LODs, S/N=3) of the proposed method for the studied PAHs were 0.004-0.03ngmL(-1). The relative standard deviations (RSDs) for five replicates at two concentration levels (0.1 and 50ngmL(-1)) of PAHs were ranged from 3.4 to 5.7%. Appropriate relative recovery values, in the range of 95.5-99.9%, were also obtained for the real water sample analysis.
    Matched MeSH terms: Chromatography, Gas
  9. Baidurah S, Murugan P, Joyyi L, Fukuda J, Yamada M, Sudesh K, et al.
    J Chromatogr A, 2016 Nov 04;1471:186-191.
    PMID: 27769532 DOI: 10.1016/j.chroma.2016.10.019
    Thermally assisted hydrolysis and methylation-gas chromatography (THM-GC) in the presence of an organic alkali was validated for the compositional analysis of poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) [P(3HB-co-3HHx)] accumulated in whole bacterial cells. Recombinant Cupriavidus necator Re2058/pCB113 was grown in a batch fermentation with different concentration of palm oil and fructose in order to control the molar fraction of 3HHx in P(3HB-co-3HHx) produced in the cells. Trace amounts (30μg) of freeze-dried cells were directly subjected to THM-GC in the presence of tetramethylammonium hydroxide (TMAH) at 400°C. The obtained chromatograms clearly showed nine characteristic peaks, attributed to the THM products from 3HB and 3HHx units in the polymer chains, without any appreciable interference by the bacterial matrix components. Based on these peak intensities, the copolymer compositions were determined rapidly without using any cumbersome and lengthy sample pretreatment as in conventional GC method. Moreover, the compositions thus obtained were strongly correlated with those by NMR and conventional GC involving solvent extraction.
    Matched MeSH terms: Chromatography, Gas*
  10. Marsin FM, Wan Ibrahim WA, Nodeh HR, Sanagi MM
    J Chromatogr A, 2020 Feb 08;1612:460638.
    PMID: 31676087 DOI: 10.1016/j.chroma.2019.460638
    Magnetic solid phase extraction (MSPE) employing oil-palm fiber activated carbon (OPAC) modified with magnetite (Fe3O4) and polypyrrole (OPAC-Fe3O4-PPy) was successfully used for the determination of two organochlorine pesticides (OCPs), namely endosulfan and dieldrin in environmental water samples. Analysis was performed using gas chromatography with micro-electron capture detection (GC-μECD). The effects of three preparation variables, namely Fe3O4:OPAC ratio, amount of pyrrole monomer, and amount of FeCl3 oxidant were optimized using Box-Behnken design (BBD) (R2 < 0.99, p-value < 0.001%). The optimum conditions were as follows: Fe3O4:OPAC ratio of 2:1 w/w, 1 g of FeCl3 and 100 μL of pyrrole monomer. The experimental results obtained agreed satisfactorily with the model prediction (> 90% agreement). Optimized OPAC-Fe3O4-PPy composite was characterized using field emission scanning electron microscope, vibrating sample magnetometer and Fourier transform infrared spectroscopy. Four numerical parameters of MSPE procedure was optimized using BBD. The significance of the MSPE parameters were salt addition > sample solution pH > extraction time and desorption time. Under the optimized conditions (extraction time: 90 s, desorption time: 10 min, salt: 0%, and pH: 5.8), the method demonstrated good linearity (25-1000 ng L-1) with coefficients of determination, R2 > 0.991, and low detection limits for both endosulfan (7.3 ng L-1) and dieldrin (8.6 ng L-1). The method showed high analyte recoveries in the range of 98.6-103.5% for environmental water samples. The proposed OPAC-Fe3O4-PPy MSPE method offered good features such as sustainability, simplicity, and rapid extraction.
    Matched MeSH terms: Chromatography, Gas*
  11. Kulsing C, Nolvachai Y, Wong YF, Glouzman MI, Marriott PJ
    J Chromatogr A, 2018 Apr 20;1546:97-105.
    PMID: 29548566 DOI: 10.1016/j.chroma.2018.02.035
    Real-time interconversion processes produce unconventional peak broadening in gas chromatography (GC), and can be used to generate kinetic and thermodynamic data. In this study, an unusual separation situation in comprehensive two dimensional GC where two dimensional interconversion (i.e. a raised plateau in both first and second dimension, 1D and 2D) was observed in analysis of oxime isomers. This resulted in a characteristic and unusual rectangular peak shape in the two dimensional result. A related theoretical approach was introduced to explain the peak shape supported by simulation results which can be varied depending on concentration profiles and kinetics of the process. The simulated results were supported by experimental results obtained by a comprehensive heart-cut multidimensional GC (H/C MDGC) approach which was developed to clearly investigate isomerisation of E/Z oxime molecules in both 1D and 2D separations under different isothermal conditions. The carrier gas flow and oven temperature were selected according to initial results for 1D interconversion on a poly(ethyleneglycol) stationary phase, which was further used in both 1D and 2D separations to result in broad zones of oxime interconversion in both dimensions. The method involved repetitive injections of oxime sample, then sampling contiguous fractions of sample into a long 2D column which is intended to promote considerable interconversion. Comprehensiveness arises from the fact that the whole sample is sampled from the 1D to the 2D column, with the long 2D column replacing the short 2D column used in classical comprehensive two-dimensional gas chromatography, where the latter will not promote sufficient interconversion. Data processing and presentation permits a 'rectangular' distribution corresponding to the separated compounds, characteristic of this experiment.
    Matched MeSH terms: Chromatography, Gas/methods*
  12. Myint S, Daud WR, Mohamad AB, Kadhum AA
    J Chromatogr B Biomed Appl, 1996 Apr 26;679(1-2):193-5.
    PMID: 8998560
    An ethanolic extract of cloves was analyzed by gas chromatography directly to identify eugenol and other major phenolic compounds without previous separation of other components. Separation was performed on a fused-silica capillary column of 30 m x 0.53 mm I.D., 0.53 microns film thickness. The detector was a flame ionization detector. Helium gas at a flow-rate of 3 ml/min was used as a carrier gas. The analysis were performed with linear temperature programming. Nine components were detected and special attention was given to the major phenolic compound, eugenol.
    Matched MeSH terms: Chromatography, Gas/methods
  13. Lee-Yin C, Ismaill BS, Salmijah S, Halimah M
    J Environ Biol, 2013 Sep;34(5):957-61.
    PMID: 24558812
    The influence of temperature, moisture and organic matter on the persistence of cyfluthrin was determined using three types of Malaysian soils, namely clay, clay loam and sandy clay loam obtained from a tomato farm in Cameron Highlands, Pahang. The persistence of cyfluthrin was observed in the laboratory at two temperature levels of 25 and 35 degreeC and field water capacity of 30 and 80%. Treated soil samples were incubated in a growth chamber for 1, 2, 3, 5, 7, 10, 14, 21 and 28 days. The results from the incubation studies showed that temperature and organic matter content significantly reduced the half-life (t1/2) values of cyfluthrin in the three soil types, but moisture content had very little effect. It was observed that cyfluthrin persisted longer at lower temperature and moisture content and higher organic matter content in all the three soil types. The present study demonstrated that under the tropical conditions of Malaysia, cyfluthrin dissipated rapidly in soils compared to its dissipation in soils of temperate regions, evidently due to high temperature.
    Matched MeSH terms: Chromatography, Gas
  14. Halimah M, Tan YA, Ismail BS
    J Environ Sci Health B, 2004;39(5-6):765-77.
    PMID: 15620085
    Four methods were developed for the analysis of fluroxypyr in soil samples from oil palm plantations. The first method involved the extraction of the herbicide with 0.05 M NaOH in methanol followed by purification using acid base partition. The concentrated material was subjected to derivatization and then cleaning process using a florisil column and finally analyzed by gas chromatography (GC) equipped with electron capture detector (ECD). By this method, the recovery of fluroxypyr from the spiked soil ranged from 70 to 104% with the minimum detection limit at 5 microg/kg. The second method involved solid liquid extraction of fluroxypyr using a horizontal shaker followed by quantification using high performance liquid chromatography (HPLC) equipped with UV detector. The recovery of fluroxypyr using this method, ranged from 80 to 120% when the soil was spiked with fluroxypyr at 0.1-0.2 microg/g soil. In the third method, the recovery of fluroxypyr was determined by solid liquid extraction using an ultrasonic bath. The recovery of fluroxypyr at spiking levels of 4-50 microg/L ranged from 88 to 98% with relative standard deviations of 3.0-5.8% with a minimum detection limit of 4 microg/kg. In the fourth method, fluroxypyr was extracted using the solid liquid extraction method followed by the cleaning up step with OASIS HLB (polyvinyl dibenzene). The recovery of fluroxypyr was between 91 and 95% with relative standard deviations of 4.2-6.2%, respectively. The limit of detection in method 4 was further improved to 1 pg/kg. When the weight of soil used was increased 4 fold, the recovery of fluroxypyr at spiking level of 1-50 microg/kg ranged from 82-107% with relative standard deviations of 0.5-4.7%.
    Matched MeSH terms: Chromatography, Gas
  15. Ismail BS, Ngan CK
    J Environ Sci Health B, 2005;40(2):341-53.
    PMID: 15825685
    A comparison of dissipation of chlorothalonil, chlorpyrifos, and profenofos in a Malaysian agricultural soil between the field experiment and simulation by the PERSIST model was studied. A plot of sweet pea (Pisum sativum) from a farm in the Cameron Highlands was selected for the field experiment. The plot was treated with chlorothalonil, chlorpyrifos, and profenofos. Core soil collection was conducted according to the sampling schedule. Residues of the three pesticides were analyzed in the laboratory. Simulations of the three pesticides' persistency were also conducted using a computer-run software PERSIST. Generally, predicted data obtained using PERSIST were found to be high for the three pesticides except for one field measurement of chlorpyrifos. The predicted data for profenofos, which is the most mobile of the three pesticides tested, was not well matched with the observed data compared to chlorothalonil and chlorpyrifos.
    Matched MeSH terms: Chromatography, Gas
  16. Hadibarata T, Yusoff AR, Aris A, Kristanti RA
    J Environ Sci (China), 2012;24(4):728-32.
    PMID: 22894109
    Armillaria sp. F022, a white rot fungus isolated from tropical rain forest (Samarinda, Indonesia) was used to biodegrade naphthalene in cultured medium. Transformation of naphthalene by Armillaria sp. F022 which is able to use naphthalene, a two ring-polycyclic aromatic hydrocarbon (PAH) as a source of carbon and energy was investigated. The metabolic pathway was elucidated by identifying metabolites, biotransformation studies and monitoring enzyme activities in cell-free extracts. The identification of metabolites suggests that Armillaria sp. F022 initiates its attack on naphthalene by dioxygenation at its C-1 and C-4 positions to give 1,4-naphthoquinone. The intermediate 2-hydroxybenzaldehyde and salicylic acid, and the characteristic of the meta-cleavage of the resulting diol were identified in the long-term incubation. A part from typical metabolites of naphthalene degradation known from mesophiles, benzoic acid was identified as the next intermediate for the naphthalene pathway of this Armillaria sp. F022. Neither phthalic acid, catechol and cis,cis-muconic acid metabolites were detected in culture extracts. Several enzymes (manganese peroxidase, lignin peroxidase, laccase, 1,2-dioxygenase and 2,3-dioxygenase) produced by Armillaria sp. F022 were detected during the incubation.
    Matched MeSH terms: Chromatography, Gas
  17. Siddique BM, Ahmad A, Alkarkhi AF, Ibrahim MH, K MO
    J Food Sci, 2011 May;76(4):C535-42.
    PMID: 22417332 DOI: 10.1111/j.1750-3841.2011.02146.x
    Candlenut oil was extracted using supercritical CO(2) (SC-CO(2)) with an optimization of parameters, by the response surface methodology. The ground candlenut samples were treated in 2 different ways, that is, dried in either a heat oven (sample moisture content of 2.91%) or dried in a vacuum oven (sample moisture content of 1.98%), before extraction. An untreated sample (moisture content of 4.87%) was used as a control. The maximum percentage of oil was extracted from the heat-oven-dried sample (77.27%), followed by the vacuum-oven-dried sample (74.32%), and the untreated sample (70.12%). At an SC-CO(2) pressure of 48.26 Mpa and 60 min of extraction time, the optimal temperatures for extraction were found to be 76.4 °C, 73.9 °C, and 70.6 °C for the untreated, heat-oven-dried, and vacuum-oven-dried samples, respectively. The heat-oven-dried sample contains the highest percentage of linoleic acid, followed by the untreated and vacuum-oven-dried samples. The antiradical activity of candlenut oil corresponded to an IC(50) value of 30.37 mg/mL.
    Matched MeSH terms: Chromatography, Gas
  18. Ali A, Hei GK, Keat YW
    J Food Sci Technol, 2016 Mar;53(3):1435-44.
    PMID: 27570268 DOI: 10.1007/s13197-015-2124-5
    Effect of 2.0 % ginger oil (GO) and 1.5 % ginger extract (GE) in combination with 10.0 % gum arabic (GA) was evaluated for the postharvest control of anthracnose and maintaining quality of Eksotika II papaya fruit during storage at 12 ± 1 °C and 80-85 % RH. Antifungal compounds present in GO and GE were analyzed using gas chromatography and GO was found to contain α-pinene, 1, 8-cineole and borneol, while only borneol was present in GE due to different extraction methods applied. The highest antifungal activity was shown in 2.0 % GO combined with 10 % GA, which significantly (P 
    Matched MeSH terms: Chromatography, Gas
  19. Chang KH, Yew CH, Abdullah AF
    J Forensic Sci, 2014 Jul;59(4):1100-8.
    PMID: 24611488 DOI: 10.1111/1556-4029.12440
    Smokeless powders are low explosives and are potentially found in cases involving firearms and improvised explosive devices. Apart from inorganic compound analysis, forensic determination of organic components of these materials appears as a promising alternative, especially the chromatographic techniques. This work describes the optimization of a solid-phase microextraction technique using an 85 μm polyacrylate fiber followed by gas chromatography-flame ionization detection for smokeless powder. A multivariate experimental design was performed to optimize extraction-influencing parameters. A 2(4) factorial first-order design revealed that sample temperature and extraction time were the major influencing parameters. Doehlert matrix design has subsequently selected 66°C and 21 min as the compromised conditions for the two predetermined parameters. This extraction technique has successfully detected the headspace compounds of smokeless powders from different ammunition types and allowed for their differentiation. The novel technique allows more rapid sample preparation for chromatographic detection of smokeless powders.
    Matched MeSH terms: Chromatography, Gas
  20. Zahed MA, Aziz HA, Mohajeri L, Mohajeri S, Kutty SR, Isa MH
    J Hazard Mater, 2010 Dec 15;184(1-3):350-6.
    PMID: 20837377 DOI: 10.1016/j.jhazmat.2010.08.043
    Response surface methodology (RSM) was employed to optimize nitrogen and phosphorus concentrations for removal of n-alkanes from crude oil contaminated seawater samples in batch reactors. Erlenmeyer flasks were used as bioreactors; each containing 250 mL dispersed crude oil contaminated seawater, indigenous acclimatized microorganism and different amounts of nitrogen and phosphorus based on central composite design (CCD). Samples were extracted and analyzed according to US-EPA protocols using a gas chromatograph. During 28 days of bioremediation, a maximum of 95% total aliphatic hydrocarbons removal was observed. The obtained Model F-value of 267.73 and probability F<0.0001 implied the model was significant. Numerical condition optimization via a quadratic model, predicted 98% n-alkanes removal for a 20-day laboratory bioremediation trial using nitrogen and phosphorus concentrations of 13.62 and 1.39 mg/L, respectively. In actual experiments, 95% removal was observed under these conditions.
    Matched MeSH terms: Chromatography, Gas
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links