Displaying publications 61 - 80 of 470 in total

Abstract:
Sort:
  1. Kok, Kuan Ying, Nur Ubaidah Saidin, Ng, Inn Khuan, Suhaila Hani Ilias, Choo, Thye Foo
    MyJurnal
    Template-assisted growth is an important nanoelectrochemical deposition technique for synthesizing one-dimensional (1-D) nanostructures with uniformly well-controlled shapes and sizes. A good template with well-defined dimensions is imperative for realizing this task. Porous anodic alumina (PAA) has been a favorable candidate for this purpose as it can be tailor-made with precise pore geometries, such as pore length and diameter as well as inter-pore distances, via the anodisation of pure aluminium. This paper reports the fabrication of PAA templates and electrochemical synthesis of functional nanostructures in the form of nanowires using PAA templates as scaffolds. Axial heterostructured and homogeneous nanowires formed by engineering materials configuration via composition and/or layer thickness variations were fabricated for different functionalities. X-ray diffraction and imaging techniques were used to elucidate the microstructures, morphologies and chemical compositions of the nanowires produced. Due to their large surface area-to-volume ratios, and therefore high sensitivities, these functional nanostructures have useful applications as critical components in nanosensor devices and various areas of nanotechnology. Potential applications include as hydrogen gas sensors in nuclear power plant for monitoring structural integrity of reactor components and containment building, as well as environmental monitoring of air pollution and leakages of toxic gases and chemicals.
    Matched MeSH terms: Electrodes
  2. Saboohi S, Yap S, Chan L, Wong C
    Sains Malaysiana, 2012;41:879-884.
    The emission of Extreme Ultra Violet (EUV) from plasma produced by vacuum spark discharge using stainless steel as anode material was investigated. The operating pressure for all the experiments carried out was maintained at below 10-4 mbar. The discharge voltage tested was from 8 kV to 20 kV. The inter-electrode distance suitable for high intensity and reproducible EUV emissions was found to be in the range of 2.6 mm to 4.6 mm. The output EUV energy scaled as ~ V02, where V0 is the discharge voltage.
    Matched MeSH terms: Electrodes
  3. Izura Izzuddin, Mohammad Hafizuddin Jumali, Muhammad Yahaya, Muhamad Mat Salleh
    Sains Malaysiana, 2012;41:1017-1021.
    The aim of this research was to investigate the ability of organometallic titanium-PANi hybrid materials as gas sensor at room temperature. To form the hybrid materials, commercially available polyaniline (PANi) powder were directly added into organometallic titanium sols which was synthesized using the sol gel method. The composite films were prepared via spin coating technique followed by electrode deposition for sensors fabrication. Five different organometallic titanium:PANi ratios namely 1 wt% to 5 wt% of PANi were prepared for this experiment. For gas sensing test, all samples were exposed to ethanol vapour. The sensing mode is based on the variation in the electrical conductivity due to the
    interaction between the gas molecules and the film. It was observed that the composite sensors required appropriate ratio to exhibit optimum sensing properties. This finding proved that the hybridization process is successful and offered much cheaper and easier method for fabrication of room temperature gas sensor.
    Matched MeSH terms: Electrodes
  4. Dhahi T, Hashim U, Ali M, Nazwa T
    Sains Malaysiana, 2012;41:755-759.
    We report here the fabrication of microgaps electrodes on amorphous silicon using low cost techniques such as vacuum deposition and conventional lithography. Amorphous silicon is a low cost material and has desirable properties for semiconductor applications. Microgap electrodes have important applications in power saving devices, electrochemical sensors and dielectric detections of biomolecules. Physical characterization by scanning electron microscopy (SEM) demonstrated such microgap electrodes could be produced with high reproducibility and precision. Preliminary electrical
    characterizations showed such structures are able to maintain a good capacitance parameters and constant current supply over a wide ranging differences in voltages. They have also good efficiency of power consumption with high insulation properties.
    Matched MeSH terms: Electrodes
  5. Khatir NM, Banihashemian SM, Periasamy V, Ritikos R, Majid WHA, Rahman SA
    Sensors (Basel), 2012;12(3):3578-3586.
    PMID: 22737025 DOI: 10.3390/s120303578
    This work presents an experimental study of gold-DNA-gold structures in the presence and absence of external magnetic fields with strengths less than 1,200.00 mT. The DNA strands, extracted by standard method were used to fabricate a Metal-DNA-Metal (MDM) structure. Its electric behavior when subjected to a magnetic field was studied through its current-voltage (I-V) curve. Acquisition of the I-V curve demonstrated that DNA as a semiconductor exhibits diode behavior in the MDM structure. The current versus magnetic field strength followed a decreasing trend because of a diminished mobility in the presence of a low magnetic field. This made clear that an externally imposed magnetic field would boost resistance of the MDM structure up to 1,000.00 mT and for higher magnetic field strengths we can observe an increase in potential barrier in MDM junction. The magnetic sensitivity indicates the promise of using MDM structures as potential magnetic sensors.
    Matched MeSH terms: Electrodes
  6. Ghadimi H, Tehrani RM, Ali AS, Mohamed N, Ab Ghani S
    Anal Chim Acta, 2013 Feb 26;765:70-6.
    PMID: 23410628 DOI: 10.1016/j.aca.2012.12.039
    A novel glassy carbon electrode (GCE) modified with a composite film of poly (4-vinylpyridine) (P4VP) and multiwalled carbon nanotubes (P4VP/MWCNT GCE) was used for the voltammetric determination of paracetamol (PCT). This novel electrode displayed a combined effect of P4VP and MWCNT on the electro-oxidation of PCT in a solution of phosphate buffer at pH 7. Hence, conducting properties of P4VP along with the remarkable physical properties of MWCNTs might have combined effects in enhancing the kinetics of PCT oxidation. The P4VP/MWCNT GCE has also demonstrated excellent electrochemical activity toward PCT oxidation compared to that with bare GCE and MWCNT GCE. The anodic peak currents of PCT on the P4VP/MWCNT GCE were about 300 fold higher than that of the non-modified electrodes. By applying differential pulse voltammetry technique under optimized experimental conditions, a good linear ratio of oxidation peak currents and concentrations of PCT over the range of 0.02-450 μM with a limit of detection of 1.69 nM were achieved. This novel electrode was stable for more than 60 days and reproducible responses were obtained at 99% of the initial current of PCT without any influence of physiologically common interferences such as ascorbic acid and uric acid. The application of this electrode to determine PCT in tablets and urine samples was proposed.
    Matched MeSH terms: Electrodes
  7. Farma R, Deraman M, Awitdrus A, Talib IA, Taer E, Basri NH, et al.
    Bioresour Technol, 2013 Mar;132:254-61.
    PMID: 23411456 DOI: 10.1016/j.biortech.2013.01.044
    Fibres from oil palm empty fruit bunches, generated in large quantities by palm oil mills, were processed into self-adhesive carbon grains (SACG). Untreated and KOH-treated SACG were converted without binder into green monolith prior to N2-carbonisation and CO2-activation to produce highly porous binderless carbon monolith electrodes for supercapacitor applications. Characterisation of the pore structure of the electrodes revealed a significant advantage from combining the chemical and physical activation processes. The electrochemical measurements of the supercapacitor cells fabricated using these electrodes, using cyclic voltammetry, electrochemical impedance spectroscopy and galvanostatic charge-discharge techniques consistently found that approximately 3h of activation time, achieved via a multi-step heating profile, produced electrodes with a high surface area of 1704m(2)g(-1) and a total pore volume of 0.889cm(3)g(-1), corresponding to high values for the specific capacitance, specific energy and specific power of 150Fg(-1), 4.297Whkg(-1) and 173Wkg(-1), respectively.
    Matched MeSH terms: Electrodes*
  8. Saharudin KA, Sreekantan S, Abd Aziz SN, Hazan R, Lai CW, Mydin RB, et al.
    J Nanosci Nanotechnol, 2013 Mar;13(3):1696-705.
    PMID: 23755576
    The present study deals with surface modification of Ti6Al4V alloy via anodization technique. The morphology, structure, adhesion and bioactivity of Ti6Al4V alloy after anodization process were investigated in detail. The influence of fluoride content and direct circuit (DC) applied voltage during anodization of Ti6Al4V alloy in a bath with electrolytes composed of ethylene glycol (EG) and ammonium fluoride (NH4F) were considered. It was found that the average pore sizes and length of nanoporous or nanotubes were increasing with the fluoride content and applied voltage. A minimum of 3 wt% of NH4F is required to grow a self-organized nanotube arrays. As the fluoride content was increased to 5 wt%, TiO2 nanotubes with average diameter of 110 nm and 3.4 microm lengths were successfully synthesized. It is noteworthy to point out that the rate of the nanotube formation was increasing up to 9 microm thick bioactive TiO2 nanotubes layer as anodization time was increased to 3 h. Based on the results obtained, the PA6 cells cultured on anodic Ti6Al4V alloy showed highest level of cell viability and greater cell adhesion compared to the flat Ti6Al4V foil substrate. In fact, highly ordered nanotubes structure on Ti6Al4V alloy can provide beneficial effects for PA6 cells in attachment and proliferation.
    Matched MeSH terms: Electrodes*
  9. Yu CY, Ang GY, Yean CY
    Chem Commun (Camb), 2013 Mar 11;49(20):2019-21.
    PMID: 23370051 DOI: 10.1039/c3cc39144b
    We developed a multiplex enzyme-based electrochemical genosensor for sequence-specific detection of multiplex linear-after-the-exponential-PCR amplicons that targeted toxigenic Vibrio cholerae O1 and O139 using novel screen-printed gold electrode bisensors.
    Matched MeSH terms: Electrodes
  10. Mohammad R, Ahmad M, Heng LY
    Sensors (Basel), 2013 Aug 05;13(8):10014-26.
    PMID: 23921830 DOI: 10.3390/s130810014
    Chili hotness is very much dependent on the concentration of capsaicin present in the chili fruit. A new biosensor based on a horseradish peroxidase enzyme-capsaicin reaction mediated by ferrocene has been successfully developed for the amperometric determination of chili hotness. The amperometric biosensor is fabricated based on a single-step immobilization of both ferrocene and horseradish peroxidase in a photocurable hydrogel membrane, poly(2-hydroxyethyl methacrylate). With mediation by ferrocene, the biosensor could measure capsaicin concentrations at a potential 0.22 V (vs. Ag/AgCl), which prevented potential interference from other electroactive species in the sample. Thus a good selectivity towards capsaicin was demonstrated. The linear response range of the biosensor towards capsaicin was from 2.5-99.0 µM with detection limit of 1.94 µM. A good relative standard deviation (RSD) for reproducibility of 6.4%-9.9% was obtained. The capsaicin biosensor demonstrated long-term stability for up to seven months. The performance of the biosensor has been validated using a standard method for the analysis of capsaicin based on HPLC.
    Matched MeSH terms: Electrodes
  11. Arip MN, Heng LY, Ahmad M, Ujang S
    Talanta, 2013 Nov 15;116:776-81.
    PMID: 24148473 DOI: 10.1016/j.talanta.2013.07.065
    The characteristics of a potentiometric biosensor for the determination of permethrin in treated wood based on immobilised cells of the fungus Lentinus sajor-caju on a potentiometric transducer are reported this paper. The potentiometric biosensor was prepared by immobilisation of the fungus in alginate gel deposited on a pH-sensitive transducer employing a photocurable acrylic matrix. The biosensor gave a good response in detecting permethrin over the range of 1.0-100.0 µM. The slope of the calibration curve was 56.10 mV/decade with detection limit of 1.00 µM. The relative standard deviation for the sensor reproducibility was 4.86%. The response time of the sensor was 5 min at optimum pH 8.0 with 1.00 mg/electrode of fungus L. sajor-caju. The permethrin biosensor performance was compared with the conventional method for permethrin analysis using high performance liquid chromatography (HPLC), and the analytical results agreed well with the HPLC method (at 95% confidence limit). There was no interference from commonly used organophosphorus pesticides such as diazinon, parathion, paraoxon, and methyl parathion.
    Matched MeSH terms: Electrodes
  12. Basirun WJ, Sookhakian M, Baradaran S, Mahmoudian MR, Ebadi M
    Nanoscale Res Lett, 2013;8(1):397.
    PMID: 24059434 DOI: 10.1186/1556-276X-8-397
    Graphene oxide (GO) film was evaporated onto graphite and used as an electrode to produce electrochemically reduced graphene oxide (ERGO) films by electrochemical reduction in 6 M KOH solution through voltammetric cycling. Fourier transformed infrared and Raman spectroscopy confirmed the presence of ERGO. Electrochemical impedance spectroscopy characterization of ERGO and GO films in ferrocyanide/ferricyanide redox couple with 0.1 M KCl supporting electrolyte gave results that are in accordance with previous reports. Based on the EIS results, ERGO shows higher capacitance and lower charge transfer resistance compared to GO.
    Matched MeSH terms: Electrodes
  13. Ahmad Z, Zafar Q, Sulaiman K, Akram R, Karimov KS
    Sensors (Basel), 2013;13(3):3615-24.
    PMID: 23493124 DOI: 10.3390/s130303615
    In this paper, we present the effect of varying humidity levels on the electrical parameters and the multi frequency response of the electrical parameters of an organic-inorganic composite (PEPC+NiPc+Cu2O)-based humidity sensor. Silver thin films (thickness ~200 nm) were primarily deposited on plasma cleaned glass substrates by the physical vapor deposition (PVD) technique. A pair of rectangular silver electrodes was formed by patterning silver film through standard optical lithography technique. An active layer of organic-inorganic composite for humidity sensing was later spun coated to cover the separation between the silver electrodes. The electrical characterization of the sensor was performed as a function of relative humidity levels and frequency of the AC input signal. The sensor showed reversible changes in its capacitance with variations in humidity level. The maximum sensitivity ~31.6 pF/%RH at 100 Hz in capacitive mode of operation has been attained. The aim of this study was to increase the sensitivity of the previously reported humidity sensors using PEPC and NiPc, which has been successfully achieved.
    Matched MeSH terms: Electrodes
  14. Ali, A.H.M., Sobri, S., Salmiaton, A., Faizah, M.Y.
    MyJurnal
    The process of etching is the most crucial part of the work of manufacturing printed circuit boards (PCB). In the etching process by nitric acid, a spent etching waste solution of composition 250 g/L HNO3, 30-40 g/L Cu, 30-40 g/L Sn, 30-40 g/L Pb and 20-25 g/L Fe is produced. High metal concentrations in the spent etching waste solution make it a viable candidate for the recovery of metals. Recovery of metals from spent etching waste solution is a significant concern as the recent growth in production of printed circuit boards has generated a drastic increase of spent etching waste solution each year. This study concerns itself with the recovery of metals from spent etching waste. In this study a dilution was made in order to increase the pH of the solution as spent etching waste solution has high acidity, and the electrowinning method was performed to recover metals from the spent etching waste solution. Glassy carbon and platinum were used as cathode and anode in order to investigate the electrodeposition of metals and cyclic voltammetry investigation suggests that the deposition of metals on glassy carbon electrodes occurs at four different overpotentials mainly at -0.15 V, -0.35 V, -0.45 V and -0.75 V. Microscopy observation demonstrates that there is a deposition of metals by applying the potentials in a set of current-time transient study for a duration of 60 seconds and the metals recovered formed as aggregates.
    Matched MeSH terms: Electrodes
  15. Muhammad Azwadi Sulaiman, Hutagalung, Sabar D., Zainal A. Ahmad
    MyJurnal
    CaCu3Ti4O12 (CCTO) has attracted a great attention for electronic devices miniaturization due to its
    very high dielectric constant properties at a wide range of frequency and nearly constant over broad temperature range. The origins of the giant dielectric constant have been speculated from electrical heterogeneous of interior elements of the CCTO ceramics. Four origins were suggested contributed to the electrical heterogeneous. In this study heat treatment were done with the electrode contact in Argon gas environment and the electrical properties over very wide frequency of CCTO ceramics were investigated. Cylindrical CCTO pellets samples were prepared by solid state reaction method and single phase of XRD pattern was obtained after sintering processes. Electrical impedance responds were measured at frequency from 100 Hz to 1 GHz for the samples for untreated and heat treated at 200ºC, 250ºC, 300ºC, 350ºC and 400ºC of CCTO. Improvement to the dielectric constant can be seen for 350ºC and 400ºC samples and dielectric loss were improved for 200ºC and 300ºC samples for overall frequency. The variations were discussed based on oxygen deficiency content and resistivity of the elements inside of CCTO structure.
    Matched MeSH terms: Electrodes
  16. Daud, M., Mohd Kamarudin, S.R., Samsu, Z., Ripin, M.S., Sattar, M.S., Rejab, R.
    MyJurnal
    The corrosion behaviour of ternary aluminium alloy sacrificial anodes with small amount addition of tin as depassivating element in natural seawater was studied by means of conventional DC electrochemical measurements. Metallurgical microscope was employed in order to observe the changing of microstructure caused by tin present in ternary alloys. The relationship between microstructure and electrochemical results was examined and particular attention paid to the cause of the electrochemical efficiency of anode performance. The results indicate that the proper precipitates uniformly distributed of tin are influence on improving electrochemical performance of alumnium alloy anode.
    Matched MeSH terms: Electrodes
  17. Mohtar MN, Hoettges KF, Hughes MP
    Electrophoresis, 2014 Feb;35(2-3):345-51.
    PMID: 24132700 DOI: 10.1002/elps.201300420
    Alternating-current electro-osmosis, a phenomenon of fluid transport due to the interaction between an electrical double layer and a tangential electric field, has been used both for inducing fluid movement and for the concentration of particles suspended in the fluid. This offers many advantages over other phenomena used to trap particles, such as placing particles at an electrode centre rather than an edge; benefits of scale, where electrodes hundreds of micrometers across can trap particles from the molecules to cells at the same rate; and a trapping volume limited by the vortex height, a phenomenon thus far unstudied. In this paper, the collection of particles due to alternating-current electro-osmosis driven collection is examined for a range of particle concentrations, inter-electrode gap widths, chamber heights and media viscosity and density. A model of collection behaviour is described where particle collection over time is governed by two processes, one driven by the vortices and the other by sedimentation, allowing the determination of the maximum height of vortex-driven collection, but also indicates how trapping is limited by high particle concentrations and fluid velocities. The results also indicate that viscosity, rather than density, is a significant governing factor in determining the trapping behaviour of particles.
    Matched MeSH terms: Electrodes
  18. Reza SM, Ahmad N, Choudhury IA, Ghazilla RA
    Sensors (Basel), 2014 Mar 04;14(3):4342-63.
    PMID: 24599193 DOI: 10.3390/s140304342
    Human motion is a daily and rhythmic activity. The exoskeleton concept is a very positive scientific approach for human rehabilitation in case of lower limb impairment. Although the exoskeleton shows potential, it is not yet applied extensively in clinical rehabilitation. In this research, a fuzzy based control algorithm is proposed for lower limb exoskeletons during sit-to-stand and stand-to-sit movements. Surface electromyograms (EMGs) are acquired from the vastus lateralis muscle using a wearable EMG sensor. The resultant acceleration angle along the z-axis is determined from a kinematics sensor. Twenty volunteers were chosen to perform the experiments. The whole experiment was accomplished in two phases. In the first phase, acceleration angles and EMG data were acquired from the volunteers during both sit-to-stand and stand-to-sit motions. During sit-to-stand movements, the average acceleration angle at activation was 11°-48° and the EMG varied from -0.19 mV to +0.19 mV. On the other hand, during stand-to-sit movements, the average acceleration angle was found to be 57.5°-108° at the activation point and the EMG varied from -0.32 mV to +0.32 mV. In the second phase, a fuzzy controller was designed from the experimental data. The controller was tested and validated with both offline and real time data using LabVIEW.
    Matched MeSH terms: Electrodes
  19. Ibitoye MO, Hamzaid NA, Zuniga JM, Abdul Wahab AK
    Clin Biomech (Bristol, Avon), 2014 Jun;29(6):691-704.
    PMID: 24856875 DOI: 10.1016/j.clinbiomech.2014.04.003
    Previous studies have explored to saturation the efficacy of the conventional signal (such as electromyogram) for muscle function assessment and found its clinical impact limited. Increasing demand for reliable muscle function assessment modalities continues to prompt further investigation into other complementary alternatives. Application of mechanomyographic signal to quantify muscle performance has been proposed due to its inherent mechanical nature and ability to assess muscle function non-invasively while preserving muscular neurophysiologic information. Mechanomyogram is gaining accelerated applications in evaluating the properties of muscle under voluntary and evoked muscle contraction with prospects in clinical practices. As a complementary modality and the mechanical counterpart to electromyogram; mechanomyogram has gained significant acceptance in analysis of isometric and dynamic muscle actions. Substantial studies have also documented the effectiveness of mechanomyographic signal to assess muscle performance but none involved comprehensive appraisal of the state of the art applications with highlights on the future prospect and potential integration into the clinical practices. Motivated by the dearth of such critical review, we assessed the literature to investigate its principle of acquisition, current applications, challenges and future directions. Based on our findings, the importance of rigorous scientific and clinical validation of the signal is highlighted. It is also evident that as a robust complement to electromyogram, mechanomyographic signal may possess unprecedented potentials and further investigation will be enlightening.
    Matched MeSH terms: Electrodes
  20. Ghanim MH, Najimudin N, Ibrahim K, Abdullah MZ
    IET Nanobiotechnol, 2014 Jun;8(2):77-82.
    PMID: 25014078 DOI: 10.1049/iet-nbt.2012.0044
    Miniaturisation of microchip capillary electrophoresis (MCE) is becoming an increasingly important research topic, particularly in areas related to micro total analysis systems or lab on a chip. One of the important features associated with the miniaturised MCE system is the portable power supply unit. In this work, a very low electric field MCE utilising an amperometric detection scheme was designed for use in DNA separation. The device was fabricated from a glass/polydimethylsiloxane hybrid engraved microchannel with platinum electrodes sputtered onto a glass substrate. Measurement was based on a three-electrode arrangement, and separation was achieved using a very low electric field of 12 V/cm and sample volume of 1.5 µl. The device was tested using two commercial DNA markers of different base pair sizes. The results are in agreement with conventional electrophoresis, but with improved resolution. The sensitivity consistently higher than 100 nA, and the separation time approximately 45 min, making this microchip an ideal tool for DNA analysis.
    Matched MeSH terms: Electrodes
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links