Methods: A retrospective study was conducted among patients with hyperthyroidism who received RAI therapy at Nuclear Medicine Clinic, Hospital Universiti Sains Malaysia (HUSM), Kelantan. Data regarding patients' demographics, gender, aetiology of hyperthyroidism, presence of autoantibodies, dose of RAI used and usage of antithyroid drug post RAI therapy were included in the analysis.
Results: Of a total of 167 screened patients, 137 subjects were eligible for this study. The incidence of hypothyroidism within one year of RAI therapy was 32.9%. Women were found to be less likely to develop hypothyroidism post RAI therapy (adjusted odds ratio, 0.406; 95% confidence interval: 0.181-0.908; p = 0.028). The usage of antithyroid drug post RAI was significantly associated with a lower incidence of hypothyroidism post RAI therapy (adjusted odds ratio, 0.188; 95% confidence interval: 0.081-0.438; p<0.001).
Conclusion: This study showed a high incidence of hypothyroidism within one-year post RAI therapy. Gender and usage of antithyroid drug post RAI therapy are significantly associated with the development of hypothyroidism.
METHODS: Nine subjects were injected intravenously with the mean (18)F-FDG dose of 292.42 MBq prior to whole body PET/CT scanning. Kidneys and urinary bladder doses were estimated by using two approaches which are the total injected activity of (18)F-FDG and organs activity concentration of (18)F-FDG based on drawn ROI with the application of recommended dose coefficients for (18)F-FDG described in the ICRP 80 and ICRP 106.
RESULTS: The mean percentage difference between calculated dose and measured dose ranged from 98.95% to 99.29% for the kidneys based on ICRP 80 and 98.96% to 99.32% based on ICRP 106. Whilst, the mean percentage difference between calculated dose and measured dose was 97.08% and 97.27% for urinary bladder based on ICRP 80 while 96.99% and 97.28% based on ICRP 106. Whereas, the range of mean percentage difference between calculated and measured organ doses derived from ICRP 106 and ICRP 80 for kidney doses were from 17.00% to 40.00% and for urinary bladder dose was 18.46% to 18.75%.
CONCLUSIONS: There is a significant difference between calculated dose and measured dose. The use of organ activity estimation based on drawn ROI and the latest version of ICRP 106 dose coefficient should be explored deeper to obtain accurate radiation dose to patients.
OBJECTIVES: The aim of the study was to evaluate the deviation of implant placement performed with a surgical guide fabricated by means of the rapid prototyping technique (the PolyJet™ technology).
MATERIAL AND METHODS: Twenty sheep mandibles were used in the study. Pre-surgical cone-beam computed tomography (CBCT) scans were acquired for the mandibles by using the Kodak 9000 3D cone-beam system. Two implants with dimensions of 4 mm in diameter and 10 mm in length were virtually planned on the 3D models of each mandible by using the Mimics software, v. 16.0. Twenty surgical guides were designed and printed using the PolyJet technology. A total of 40 implants were placed using the surgical guides, 1 on each side of the mandible (2 implants per mandible). The post-surgical CBCT scans of the mandibles were performed and superimposed on the pre-surgical CBCT scans. The amount of deviation between the virtually planned placement and the actual implant placement was measured, and a descriptive analysis was done.
RESULTS: The results showed that the mean deviation at the implant coronal position was 1.82 ±0.74 mm, the mean deviation at the implant apex was 1.54 ±0.88 mm, the mean depth deviation was 0.44 ±0.32 mm, and the mean angular deviation was 3.01 ±1.98°.
CONCLUSIONS: The deviation of dental implant placement performed with a 3D-printed surgical guide (the PolyJet technology) is within the acceptable 2-millimeter limit reported in the literature.
Case Report: We present a case of a newborn baby who developed biphasic stridor immediately after a normal vaginal delivery. Endoscopic assessment of the trachea revealed a pulsatile narrowing at the level of the thoracic trachea, suggestive of an external compression. A contrast-enhanced computed tomography scan of the thorax with three-dimensional reconstruction confirmed the diagnosis of DAA with compression of the trachea and esophagus.
Conclusion: Clinicians should strongly consider the possibility of a congenital vascular ring compression should an infant with a normal upper airway present with stridor. A precise diagnosis can be made by radiological examination.