METHODOLOGY: Jaw sections containing 67 teeth (86 roots) were collected from unclaimed bodies due for cremation. Imaging was carried out to detect AP by digital PR with a central view (DP group), digital PR combining central with 10˚ mesially and distally angled (parallax) views (DPS group) and CBCT scans. All specimens underwent histopathological examination to confirm the diagnosis of AP. Sensitivity, specificity and predictive values of PR and CBCT were analysed using rater mean (n = 5). Receiver-operating characteristic (ROC) analysis was carried out.
RESULTS: Sensitivity was 0.27, 0.38 and 0.89 for DP, DPS and CBCT scans, respectively. CBCT had specificity and positive predictive value of 1.0 whilst DP and DPS had specificity and positive predictive value of 0.99. The negative predictive value was 0.39, 0.44 and 0.81 for DP, DPS and CBCT scans, respectively. Area under the curve (AUC) for the various imaging methods was 0.629 (DP), 0.688 (DPS), and 0.943 (CBCT).
CONCLUSIONS: All imaging techniques had similar specificity and positive predictive values. Additional parallax views increased the diagnostic accuracy of PR. CBCT had significantly higher diagnostic accuracy in detecting AP compared to PR, using human histopathological findings as a reference standard.
Materials and Methods: This study was conducted between Oct 2010 to Dec 2015. One-hundred-fifty fracture shafts of the humerus were treated with the anteromedial plating through the anterolateral approach.
Results: One-hundred-fifty patients with a fracture shaft of the humerus were treated with anteromedial plating. Twenty were female (mean ±SD,28 years±4.5) and 130 were male (mean ± SD, 38 years±5.6). One hundred and forty-eight out of 150 (98.6%) patients achieved union at 12 months. Two of three patients developed a superficial infection, both of which were treated successfully by antibiotics and one developed a deep infection, which was treated by wound debridement, prolonged antibiotics with the removal of the plate and subsequently by delayed plating and bone grafting.
Conclusion: In the present study, we applied plate on the anteromedial flat surface of humerus using the anterolateral approach. It is an easier and quicker fixation as compared to anterolateral plating because later involved much more dissection than a medial application of the plate and this application of plate on a medial flat surface, does not required Radial nerve exposure and palsy post-operatively. The significant improvement in elbow flexion without brachialis dissection is also a potential benefit of this approach. Based on our results, we recommend the application of an anteromedial plate for treatment of midshaft fractures humerus.
PRESENTATION OF CASE: A 30-year-old woman, who had a previous cesarean delivery, opted for another cesarean section (CS) during this pregnancy. She claimed that her tummy was lax after her first experience of CS even with regular exercise. A standard CS procedure was carried out along with the new modified undermined suture technique for rectus muscle re-approximation. Post-operatively, the pain score was 2/10 without any evidence of hematoma, seromas or infection and the patient ambulates well. The patient did not complain of any pain or complications upon follow up after 2 weeks and 2 months post-operation. She claims that her abdomen is firmer, flatter and more stable compared to her previous operation experience.
DISCUSSION: This newly modified method prevents any defect or weakness on the anterior abdominal wall even if the rectus muscles fail to oppose itself during the healing process. It also mimics the function of the linea alba and avoid interrupting the contraction or injuring the muscle in order to avoid pain. Adhesion of the anterior uterine wall and the rectus sheath can be prevented by closure of the rectus muscle and burying the suture material within the muscle.
CONCLUSION: The newly modified undermined suture rectus muscle technique at cesarean delivery has the potential to improved patient's post-operative satisfaction.
Materials and Methods: The coagulometer for factor VIII assay is Sysmex CS-5100. All data were expressed as mean ± standard deviation (SD).
Results: A total of 135 cases were studied. Of these, 100 cases were of mild hemophilia A diagnosed by molecular genetics and, 15 cases were positive for LAC, which were confirmed by dilute Russell Viper venom test. Clot-based one-stage APTT assay showed 65% sensitivity and 80% specificity in diagnosing mild hemophilia A cases and out of 15 LAC cases, it showed false positivity in five cases. Chromogenic assay showed 85% sensitivity and 90% specificity in diagnosing mild hemophilia cases and was 100% specific in excluding LAC cases.
Conclusions: One-stage APTT assay is the most commonly used test for determining factor VIII levels but chromogenic assay are considered as the gold standard and recommended as the reference method by European Pharmacopoeia and ISTH subcommittee. Mild hemophilia A patients with missense mutations show discrepancy between the one-stage clot-based APTT assay and chromogenic assays for determination of factor VIII level and this can lead to misdiagnosis or misclassification of mild hemophilia A. Therefore, it is recommended that both the assays should be used in the evaluation of mild hemophilia cases.
Materials and Methods: The questionnaire was first translated into the Malay language (RDAS-M). In this cross-sectional study, healthy married Malay women in Kota Bharu, Kelantan, were recruited from January to April 2018. Participants were asked to complete the RDAS-M that consists of three domains, that is, dyadic consensus, dyadic satisfaction, and dyadic cohesion with a total of 14 items. The concept, content, and construct validity using exploratory factor analysis (EFA) and reliability of the RDAS-M were assessed.
Results: Of the 164 recruited participants, 150 consented to participate. The mean age of the participants was 34.1 years (standard deviation [SD], 9.5 years), ranging from 20 to 57 years. All 14 items were considered comprehensible by more than 95% of the subjects. Based on EFA, total variance extracted was 69.08%, and the original three factors were retained. The Malay version of the RDAS was valid based on factor loadings for dyadic consensus, dyadic satisfaction, and dyadic cohesion, which ranged from 0.64 to 0.80, 0.79 to 0.98, and 0.37 to 0.78, respectively. The internal consistency was good with coefficient α of 0.87 for dyadic consensus, 0.93 for dyadic satisfaction, and 0.78 for dyadic cohesion.
Conclusions: The Malay version of the RDAS is easy to understand, and is a reliable and valid instrument for married women. It is also comparable with the original version of the RDAS in terms of structure and psychometric properties.