Displaying publications 61 - 80 of 2008 in total

Abstract:
Sort:
  1. Bidawid S, Malik N, Adegbunrin O, Sattar SA, Farber JM
    J Virol Methods, 2003 Feb;107(2):163-7.
    PMID: 12505630
    Feline calicivirus (FCV) has been used by researchers as a surrogate for Norwalk virus (NV), since they share a similar genomic organization, physicochemical characteristics, and are grouped in the same family, Caliciviridae. Unlike NV, however, FCV can grow in established cell lines and produce a syncytial form of cytopathic effect. In this report, we describe the development and standardization of a plaque assay for FCV using monolayers of an established line of feline kidney (CrFK) cells in 12-well cell culture plates. The assay method has demonstrated reproducibility, ease of performance and resulted in clear plaque zones, readable in 24 h after virus inoculation. The infectivity titre of the virus by this plaque assay agreed well with tissue culture infectious dose(50) (TCID(50)) determinations. The described plaque assay would be a valuable tool in conducting various quantitative investigations using FCV as a model for NV and Norwalk-like viruses (NLV).
    Matched MeSH terms: Reproducibility of Results
  2. Kamel N, Yusoff MZ
    PMID: 19163891 DOI: 10.1109/IEMBS.2008.4650388
    A "single-trial" signal subspace approach for extracting visual evoked potential (VEP) from the ongoing 'colored' electroencephalogram (EEG) noise is proposed. The algorithm applies the generalized eigendecomposition on the covariance matrices of the VEP and noise to transform them jointly into diagonal matrices in order to avoid a pre-whitening stage. The proposed generalized subspace approach (GSA) decomposes the corrupted VEP space into a signal subspace and noise subspace. Enhancement is achieved by removing the noise subspace and estimating the clean VEPs only from the signal subspace. The validity and effectiveness of the proposed GSA scheme in estimating the latencies of P100's (used in objective assessment of visual pathways) are evaluated using real data collected from Selayang Hospital in Kuala Lumpur. The performance of GSA is compared with the recently proposed single-trial technique called the Third Order Correlation (TOC).
    Matched MeSH terms: Reproducibility of Results
  3. Ng CC, Yew PY, Puah SM, Krishnan G, Yap LF, Teo SH, et al.
    J Hum Genet, 2009 Jul;54(7):392-7.
    PMID: 19478819 DOI: 10.1038/jhg.2009.49
    To identify a gene(s) susceptible to nasopharyngeal carcinoma (NPC), we carried out a genome-wide association study (GWAS) through genotyping of more than 500,000 tag single-nucleotide polymorphisms (SNPs), using an initial sample set of 111 unrelated NPC patients and 260 controls of a Malaysian Chinese population. We further evaluated the top 200 SNPs showing the smallest P-values, using a replication sample set that consisted of 168 cases and 252 controls. The combined analysis of the two sets of samples found an SNP in intron 3 of the ITGA9 (integrin-alpha 9) gene, rs2212020, to be strongly associated with NPC (P=8.27 x 10(-7), odds ratio (OR)=2.24, 95% confidence intervals (CI)=1.59-3.15). The gene is located at 3p21 which is commonly deleted in NPC cells. We subsequently genotyped additional 19 tag SNPs within a 40-kb linkage disequilibrium (LD) block surrounding this landmark SNP. Among them, SNP rs189897 showed the strongest association with a P-value of 6.85 x 10(-8) (OR=3.18, 95% CI=1.94-5.21), suggesting that a genetic variation(s) in ITGA9 may influence susceptibility to NPC in the Malaysian Chinese population.
    Matched MeSH terms: Reproducibility of Results
  4. Chan KL, Yuen KH, Jinadasa S, Peh KK, Toh WT
    Planta Med, 1997 Feb;63(1):66-9.
    PMID: 9063097
    A high-performance liquid chromatography assay equipped with a glassy carbon electrode for electrochemical detection (HPLC-ECD) was developed at reductive mode for the analysis of artemisinin, the antimalarial drug from Artemisia annua (Asteraceae) in human plasma. This method was selective, sensitive, and produced satisfactory recovery, precision, and accuracy. Analysis of plasma samples from 8 male volunteers given 10 mg kg-1 of artemisinin orally as an aqueous suspension showed a mean peak plasma concentration (Cmax) of 580.89 ng ml-1 +/- 88.64 SD at 2.5 h +/- 0.5 SD after dosing, and the mean area under the plasma concentration-time curve (AUC0-infinity) was 2227.57 ng h ml-1 +/- 677.22 SD. In addition, the elimination rate constant (Ke), elimination half-life (t1/2), and apparent volume of distribution (Vd) were calculated to be 0.2971 h-1 +/- 0.0644 SD, 2.42 h +/- 0.46 SD, and 16.26 l kg-1 +/- 3.44 SD, respectively.
    Matched MeSH terms: Reproducibility of Results
  5. He J, Sunarso J, Miao J, Sun H, Dai J, Zhang C, et al.
    J Hazard Mater, 2019 05 05;369:699-706.
    PMID: 30831522 DOI: 10.1016/j.jhazmat.2019.02.070
    Effective regulation of p-phenylenediamine (PPD), a widely used precursor of hair dye that is harmful to human health in large concentration, relies upon an accurate yet simple detection of PPD. In this context, amperometric electrode sensor based on perovskite oxide becomes attractive given its portability, low cost, high sensitivity, and rapid processing time. This work reports the systematic characterization of a series of Sr-doped PrCoO3-δ perovskite oxides with composition of Pr1-xSrxCoO3-δ(x = 0, 0.2, 0.4, 0.6, 0.8, and 1) for PPD detection in an alkaline solution. PSC82 deposited onto glassy carbon electrode (PSC82/GCE) generates the highest redox currents which correlates with the highest hydrogen peroxide intermediates (HO2-) yield and the σ*-orbital (eg) filling of Co that is closest to unity for PSC82. PSC82/GCE provides the highest sensitivities of 655 and 308 μA mM-1 cm-2 in PPD concentration range of 0.5-2,900 and 2,900-10,400 μM, respectively, with a limit of detection of 0.17 μM. PSC82/GCE additionally demonstrates high selectivity to PPD and long term stability during 50 consecutive cyclic voltammetry scans and over 1-month storage period. The potential applicability of PSC82/GCE was also demonstrated by confirming the presence of very low concentration of PPD of below 0.5% in real hair dyes.
    Matched MeSH terms: Reproducibility of Results
  6. Tayan O, Kabir MN, Alginahi YM
    ScientificWorldJournal, 2014;2014:514652.
    PMID: 25254247 DOI: 10.1155/2014/514652
    This paper addresses the problems and threats associated with verification of integrity, proof of authenticity, tamper detection, and copyright protection for digital-text content. Such issues were largely addressed in the literature for images, audio, and video, with only a few papers addressing the challenge of sensitive plain-text media under known constraints. Specifically, with text as the predominant online communication medium, it becomes crucial that techniques are deployed to protect such information. A number of digital-signature, hashing, and watermarking schemes have been proposed that essentially bind source data or embed invisible data in a cover media to achieve its goal. While many such complex schemes with resource redundancies are sufficient in offline and less-sensitive texts, this paper proposes a hybrid approach based on zero-watermarking and digital-signature-like manipulations for sensitive text documents in order to achieve content originality and integrity verification without physically modifying the cover text in anyway. The proposed algorithm was implemented and shown to be robust against undetected content modifications and is capable of confirming proof of originality whilst detecting and locating deliberate/nondeliberate tampering. Additionally, enhancements in resource utilisation and reduced redundancies were achieved in comparison to traditional encryption-based approaches. Finally, analysis and remarks are made about the current state of the art, and future research issues are discussed under the given constraints.
    Matched MeSH terms: Reproducibility of Results
  7. Nikpay F, Ahmad R, Yin Kia C
    Eval Program Plann, 2017 02;60:1-16.
    PMID: 27665066 DOI: 10.1016/j.evalprogplan.2016.09.001
    Enterprise Architecture (EA) implementation evaluation provides a set of methods and practices for evaluating the EA implementation artefacts within an EA implementation project. There are insufficient practices in existing EA evaluation models in terms of considering all EA functions and processes, using structured methods in developing EA implementation, employing matured practices, and using appropriate metrics to achieve proper evaluation. The aim of this research is to develop a hybrid evaluation method that supports achieving the objectives of EA implementation. To attain this aim, the first step is to identify EA implementation evaluation practices. To this end, a Systematic Literature Review (SLR) was conducted. Second, the proposed hybrid method was developed based on the foundation and information extracted from the SLR, semi-structured interviews with EA practitioners, program theory evaluation and Information Systems (ISs) evaluation. Finally, the proposed method was validated by means of a case study and expert reviews. This research provides a suitable foundation for researchers who wish to extend and continue this research topic with further analysis and exploration, and for practitioners who would like to employ an effective and lightweight evaluation method for EA projects.
    Matched MeSH terms: Reproducibility of Results
  8. Lim CP, Leong JH, Kuan MM
    IEEE Trans Pattern Anal Mach Intell, 2005 Apr;27(4):648-53.
    PMID: 15794170
    A hybrid neural network comprising Fuzzy ARTMAP and Fuzzy C-Means Clustering is proposed for pattern classification with incomplete training and test data. Two benchmark problems and a real medical pattern classification task are employed to evaluate the effectiveness of the hybrid network. The results are analyzed and compared with those from other methods.
    Matched MeSH terms: Reproducibility of Results
  9. Alqasaimeh M, Heng LY, Ahmad M, Raj AS, Ling TL
    Sensors (Basel), 2014 Jul 22;14(7):13186-209.
    PMID: 25054632 DOI: 10.3390/s140713186
    A new silica-gel nanospheres (SiO2NPs) composition was formulated, followed by biochemical surface functionalization to examine its potential in urea biosensor development. The SiO2NPs were basically synthesized based on sol-gel chemistry using a modified Stober method. The SiO2NPs surfaces were modified with amine (-NH2) functional groups for urease immobilization in the presence of glutaric acid (GA) cross-linker. The chromoionophore pH-sensitive dye ETH 5294 was physically adsorbed on the functionalized SiO2NPs as pH transducer. The immobilized urease determined urea concentration reflectometrically based on the colour change of the immobilized chromoionophore as a result of the enzymatic hydrolysis of urea. The pH changes on the biosensor due to the catalytic enzyme reaction of immobilized urease were found to correlate with the urea concentrations over a linear response range of 50-500 mM (R2 = 0.96) with a detection limit of 10 mM urea. The biosensor response time was 9 min with reproducibility of less than 10% relative standard deviation (RSD). This optical urea biosensor did not show interferences by Na+, K+, Mg2+ and NH4+ ions. The biosensor performance has been validated using urine samples in comparison with a non-enzymatic method based on the use of p-dimethylaminobenzaldehyde (DMAB) reagent and demonstrated a good correlation between the two different methods (R2 = 0.996 and regression slope of 1.0307). The SiO2NPs-based reflectometric urea biosensor showed improved dynamic linear response range when compared to other nanoparticle-based optical urea biosensors.
    Matched MeSH terms: Reproducibility of Results
  10. Ahmadi K, Reidpath DD, Allotey P, Hassali MAA
    BMC Med Educ, 2016 May 30;16:155.
    PMID: 27240562 DOI: 10.1186/s12909-016-0676-3
    BACKGROUND: The attitudes of healthcare professionals towards HIV positive patients and high risk groups are central to the quality of care and therefore to the management of HIV/AIDS related stigma in health settings. Extant HIV/AIDS stigma scales that measure stigmatising attitudes towards people living with HIV/AIDS have been developed using scaling techniques such as principal component analysis. This approach has resulted in instruments that are often long. Mokken scale analysis is a nonparametric hierarchical scaling technique that can be used to develop unidimensional cumulative scales. This technique is advantageous over the other approaches; as the scales are usually shorter, while retaining acceptable psychometric properties. Moreover, Mokken scales also make no distributional assumptions about the underlying data, other than that the data are capable of being ordered by item and by person. In this study we aimed at developing a precise and concise measure of HIV/AIDS related stigma among health care professionals, using Mokken scale analysis.
    METHODS: We carried out a cross sectional survey of healthcare students at the Monash University campuses in Malaysia and Australia. The survey consisted of demographic questions and an initial item pool of twenty five potential questions for inclusion in an HIV stigma scale.
    RESULTS: We analysed the data using the mokken package in the R statistical environment providing a 9-item scale with high reliability, validity and acceptable psychometric properties, measuring and ranking the HIV/AIDS related stigmatising attitudes.
    CONCLUSION: Mokken scaling procedure not only produced a comprehensive hierarchical scale that could accurately order a person along HIV/AIDS stigmatising attitude, but also demonstrated a unidimensional and reliable measurement tool which could be used in future studies. The principal component analysis confirmed the accuracy of the Mokken scale analysis in correctly detecting the unidimensionality of this scale. We recommend future works to study the generalisability of this scale in a new population.
    Matched MeSH terms: Reproducibility of Results
  11. Ang SH, Thevarajah TM, Woi PM, Alias YB, Khor SM
    J Chromatogr B Analyt Technol Biomed Life Sci, 2016 Mar 15;1015-1016:157-165.
    PMID: 26927875 DOI: 10.1016/j.jchromb.2016.01.059
    An immunosensor that operates based on the principles of lateral flow was developed for direct detection of hemoglobin A1c (HbA1c) in whole blood. We utilized colloidal gold-functionalized antibodies to transduce the specific signal generated when sandwich immuno-complexes were formed on the strip in the presence of HbA1c. The number and intensity of the test lines on the strips indicate normal, under control, and elevated levels of HbA1c. In addition, a linear relationship between HbA1c levels and immunosensor signal intensity was confirmed, with a dynamic range of 4-14% (20-130 mmol mol(-1)) HbA1c. Using this linear relationship, we determined the HbA1c levels in blood as a function of the signal intensity on the strips. Measurements were validated using the Bio-Rad Variant II HPLC and DCA Vantage tests. Moreover, the immunosensor was verified to be highly selective for detection of HbA1c against HbA0, glycated species of HbA0, and HbA2. The limit of detection was found to be 42.5 μg mL(-1) (1.35 mmol mol(-1)) HbA1c, which is reasonably sensitive compared to the values reported for microarray immunoassays. The shelf life of the immunosensor was estimated to be 1.4 months when stored at ambient temperature, indicating that the immunoassay is stable. Thus, the lateral flow immunosensor developed here was shown to be capable of performing selective, accurate, rapid, and stable detection of HbA1c in human blood samples.
    Matched MeSH terms: Reproducibility of Results
  12. Junaid M, Sultan M, Liu S, Hamid N, Yue Q, Pei DS, et al.
    Sci Total Environ, 2024 Mar 20;917:170535.
    PMID: 38307287 DOI: 10.1016/j.scitotenv.2024.170535
    Owing to a wide range of advantages, such as stability, non-invasiveness, and ease of sampling, hair has been used progressively for comprehensive biomonitoring of organic pollutants for the last three decades. This has led to the development of new analytical and multi-class analysis methods for the assessment of a broad range of organic pollutants in various population groups, ranging from small-scale studies to advanced studies with a large number of participants based on different exposure settings. This meta-analysis summarizes the existing literature on the assessment of organic pollutants in hair in terms of residue levels, the correlation of hair residue levels with those of other biological matrices and socio-demographic factors, the reliability of hair versus other biomatrices for exposure assessment, the use of segmental hair analysis for chronic exposure evaluation and the effect of external contamination on hair residue levels. Significantly high concentrations of organic pollutants such as pesticides, flame retardants, polychlorinated biphenyls and polycyclic aromatic hydrocarbon were reported in human hair samples from different regions and under different exposure settings. Similarly, high concentrations of pesticides (from agricultural activities), flame retardants (E-waste dismantling activities), dioxins and furans were observed in various occupational settings. Moreover, significant correlations (p 
    Matched MeSH terms: Reproducibility of Results
  13. Tan CY, Sekiguchi Y, Goh KJ, Kuwabara S, Shahrizaila N
    Clin Neurophysiol, 2020 01;131(1):63-69.
    PMID: 31751842 DOI: 10.1016/j.clinph.2019.09.025
    OBJECTIVE: We aimed to develop a model that can predict the probabilities of acute inflammatory demyelinating polyneuropathy (AIDP) based on nerve conduction studies (NCS) done within eight weeks.

    METHODS: The derivation cohort included 90 Malaysian GBS patients with two sets of NCS performed early (1-20days) and late (3-8 weeks). Potential predictors of AIDP were considered in univariate and multivariate logistic regression models to develop a predictive model. The model was externally validated in 102 Japanese GBS patients.

    RESULTS: Median motor conduction velocity (MCV), ulnar distal motor latency (DML) and abnormal ulnar/normal sural pattern were independently associated with AIDP at both timepoints (median MCV: p = 0.038, p = 0.014; ulnar DML: p = 0.002, p = 0.003; sural sparing: p = 0.033, p = 0.009). There was good discrimination of AIDP (area under the curve (AUC) 0.86-0.89) and this was valid in the validation cohort (AUC 0.74-0.94). Scores ranged from 0 to 6, and corresponded to AIDP probabilities of 15-98% at early NCS and 6-100% at late NCS.

    CONCLUSION: The probabilities of AIDP could be reliably predicted based on median MCV, ulnar DML and ulnar/sural sparing pattern that were determined at early and late stages of GBS.

    SIGNIFICANCE: A simple and valid model was developed which can accurately predict the probability of AIDP.

    Matched MeSH terms: Reproducibility of Results
  14. Ismail M, Phang SM, Tong SL, Brown MT
    Environ Monit Assess, 2002 Apr;75(2):145-54.
    PMID: 12002283
    Toxicity testing of four heavy metals (Cd, Cu, Mn and As) using four species of tropical marine phytoplankton, Chaetoceros calcitrans, Isochrysis galbana, Tetraselmis tetrahele and Tetraselmis sp., was carried out in multiwell plates with test volumes of 2 mL and the results compared to those of standard, large volume, shake-flasks. IC50 values (concentrations of metals estimated to inhibit 50% growth relative to the control) were determined after 96 hours based on automated O.D. readings measured in Elisa microplates by a Multiskan spectrophotometer. Good agreement was achieved between O.D. readings and cell counts indicating that this new method is a simple, economical, practical and rapid technique for toxicity testing, and provides good reproducibility of IC50 values. Results of the toxicity tests indicate that Cu was the most toxic metal (average IC50 values ranging from 0.04 to 0.37 mg L(-1)), followed by Cd (0.06-5.7 mg L(-1)), Mn (7.2-21.4 mg L(-1)) and As (33.9-319.3 mg L(-1)). Test species had different degrees of sensitivity to the metals tested, with I. galbana and C. calcitrans the most sensitive to Cu, Cd and Mn. Based on these findings it is recommended that the existing Malaysian Interim Standards for Marine Water Quality for Cd and Cu be reviewed.
    Matched MeSH terms: Reproducibility of Results
  15. Fauzi MF, Gokozan HN, Elder B, Puduvalli VK, Pierson CR, Otero JJ, et al.
    J Neurooncol, 2015 Sep;124(3):393-402.
    PMID: 26255070 DOI: 10.1007/s11060-015-1872-4
    We present a computer aided diagnostic workflow focusing on two diagnostic branch points in neuropathology (intraoperative consultation and p53 status in tumor biopsy specimens) by means of texture analysis via discrete wavelet frames decomposition. For intraoperative consultation, our methodology is capable of classifying glioblastoma versus metastatic cancer by extracting textural features from the non-nuclei region of cytologic preparations based on the imaging characteristics of glial processes, which appear as anisotropic thin linear structures. For metastasis, these are homogeneous in appearance, thus suitable and extractable texture features distinguish the two tissue types. Experiments on 53 images (29 glioblastomas and 24 metastases) resulted in average accuracy as high as 89.7 % for glioblastoma, 87.5 % for metastasis and 88.7 % overall. For p53 interpretation, we detect and classify p53 status by classifying staining intensity into strong, moderate, weak and negative sub-classes. We achieved this by developing a novel adaptive thresholding for detection, a two-step rule based on weighted color and intensity for the classification of positively and negatively stained nuclei, followed by texture classification to classify the positively stained nuclei into the strong, moderate and weak intensity sub-classes. Our detection method is able to correctly locate and distinguish the four types of cells, at 85 % average precision and 88 % average sensitivity rate. These classification methods on the other hand recorded 81 % accuracy in classifying the positive and negative cells, and 60 % accuracy in further classifying the positive cells into the three intensity groups, which is comparable with neuropathologists' markings.
    Matched MeSH terms: Reproducibility of Results
  16. Gomez R, Burns GL, Walsh JA, Hafetz N
    J Abnorm Child Psychol, 2005 Apr;33(2):241-54.
    PMID: 15839501 DOI: 10.1007/s10802-005-1831-1
    Confirmatory factor analysis (CFA) was used to model a multitrait by multisource matrix to determine the convergent and discriminant validity of measures of attention-deficit hyperactivity disorder (ADHD)-inattention (IN), ADHD-hyperactivity/impulsivity (HI), and oppositional defiant disorder (ODD) in 917 Malaysian elementary school children. The three trait factors were ADHD-IN, ADHDHI, and ODD. The two source factors were parents and teachers. Similar to earlier studies with Australian and Brazilian children, the parent and teacher measures failed to show convergent and discriminant validity with Malaysian children. The study outlines the implications of such strong source effects in ADHD-IN, ADHD-HI, and ODD measures for the use of such parent and teacher scales to study the symptom dimensions.
    Matched MeSH terms: Reproducibility of Results
  17. Kho SK, Leong BQZ, Keeble DRT, Wong HK, Estudillo AJ
    Behav Res Methods, 2024 Mar;56(3):1192-1206.
    PMID: 36971958 DOI: 10.3758/s13428-023-02085-6
    The Cambridge Face Memory Test (CFMT) is one of the most important measures of individual differences in face recognition and for the diagnosis of prosopagnosia. Having two different CFMT versions using a different set of faces seems to improve the reliability of the evaluation. However, at the present time, there is only one Asian version of the test. In this study, we present the Cambridge Face Memory Test - Chinese Malaysian (CFMT-MY), a novel Asian CFMT using Chinese Malaysian faces. In Experiment 1, Chinese Malaysian participants (N = 134) completed two versions of the Asian CFMT and one object recognition test. The CFMT-MY showed a normal distribution, high internal reliability, high consistency and presented convergent and divergent validity. Additionally, in contrast to the original Asian CFMT, the CFMT-MY showed an increasing level of difficulties across stages. In Experiment 2, Caucasian participants (N = 135) completed the two versions of the Asian CFMT and the original Caucasian CFMT. Results showed that the CFMT-MY exhibited the other-race effect. Overall, the CFMT-MY seems to be suitable for the diagnosis of face recognition difficulties and could be used as a measure of face recognition ability by researchers who wish to examine face-related research questions such as individual differences or the other-race effect.
    Matched MeSH terms: Reproducibility of Results
  18. Ramanathan S, Karupiah S, Nair NK, Olliaro PL, Navaratnam V, Wernsdorfer WH, et al.
    PMID: 16046285
    A new approach using a simple solid-phase extraction technique has been developed for the determination of pyronaridine (PND), an antimalarial drug, in human plasma. After extraction with C18 solid-phase sorbent, PND was analyzed using a reverse phase chromatographic method with fluorescence detection (at lambda(ex)=267 nm and lambda(em)=443 nm). The mean extraction recovery for PND was 95.2%. The coefficient of variation for intra-assay precision, inter-assay precision and accuracy was less than 10%. The quantification limit with fluorescence detection was 0.010 microg/mL plasma. The method described herein has several advantages over other published methods since it is easy to perform and rapid. It also permits reducing both, solvent use and sample preparation time. The method has been used successfully to assay plasma samples from clinical pharmacokinetic studies.
    Matched MeSH terms: Reproducibility of Results
  19. Yildirim O, Baloglu UB, Tan RS, Ciaccio EJ, Acharya UR
    Comput Methods Programs Biomed, 2019 Jul;176:121-133.
    PMID: 31200900 DOI: 10.1016/j.cmpb.2019.05.004
    BACKGROUND AND OBJECTIVE: For diagnosis of arrhythmic heart problems, electrocardiogram (ECG) signals should be recorded and monitored. The long-term signal records obtained are analyzed by expert cardiologists. Devices such as the Holter monitor have limited hardware capabilities. For improved diagnostic capacity, it would be helpful to detect arrhythmic signals automatically. In this study, a novel approach is presented as a candidate solution for these issues.

    METHODS: A convolutional auto-encoder (CAE) based nonlinear compression structure is implemented to reduce the signal size of arrhythmic beats. Long-short term memory (LSTM) classifiers are employed to automatically recognize arrhythmias using ECG features, which are deeply coded with the CAE network.

    RESULTS: Based upon the coded ECG signals, both storage requirement and classification time were considerably reduced. In experimental studies conducted with the MIT-BIH arrhythmia database, ECG signals were compressed by an average 0.70% percentage root mean square difference (PRD) rate, and an accuracy of over 99.0% was observed.

    CONCLUSIONS: One of the significant contributions of this study is that the proposed approach can significantly reduce time duration when using LSTM networks for data analysis. Thus, a novel and effective approach was proposed for both ECG signal compression, and their high-performance automatic recognition, with very low computational cost.

    Matched MeSH terms: Reproducibility of Results
  20. Rohawi NS, Ramasamy K, Agatonovic-Kustrin S, Lim SM
    PMID: 29894935 DOI: 10.1016/j.jchromb.2018.06.009
    A quantitative assay using high-performance thin-layer chromatography (HPTLC) was developed to investigate bile salt hydrolase (BSH) activity in Pediococcus pentosaceus LAB6 and Lactobacillus plantarum LAB12 probiotic bacteria isolated from Malaysian fermented food. Lactic acid bacteria (LAB) were cultured in de Man Rogosa and Sharpe (MRS) broth containing 1 mmol/L of sodium-based glyco- and tauro-conjugated bile salts for 24 h. The cultures were centrifuged and the resultant cell free supernatant was subjected to chromatographic separation on a HPTLC plate. Conjugated bile salts were quantified by densitometric scans at 550 nm and results were compared to digital image analysis of chromatographic plates after derivatisation with anisaldehyde/sulfuric acid. Standard curves for bile salts determination with both methods show good linearity with high coefficient of determination (R2) between 0.97 and 0.99. Method validation indicates good sensitivity with low relative standard deviation (RSD) (<10%), low limits of detection (LOD) of 0.4 versus 0.2 μg and limit of quantification (LOQ) of 1.4 versus 0.7 μg, for densitometric vs digital image analysis method, respectively. The bile salt hydrolase activity was found to be higher against glyco- than tauro-conjugated bile salts (LAB6; 100% vs >38%: LAB12; 100% vs >75%). The present findings strongly show that quantitative analysis via digitally-enhanced HPTLC offers a rapid quantitative analysis for deconjugation of bile salts by probiotics.
    Matched MeSH terms: Reproducibility of Results
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links