Displaying publications 81 - 100 of 286 in total

Abstract:
Sort:
  1. Jailani RF, Kosai NR, Yaacob NY, Jarmin R, Sutton P, Harunarrashid H, et al.
    Clin Ter, 2014;165(6):294-8.
    PMID: 25524184 DOI: 10.7417/CT.2014.1771
    BACKGROUND AND OBJECTIVE: To compare the outcome of transarterial angioembolization (TAE) and surgery with endoscopically unmanageable non-variceal hemorrhage of the upper gastrointestinal tract.

    MATERIALS AND METHODS: A case note review of all patients treated for non-variceal upper gastrointestinal bleeding from January 2006 till January 2012 was performed.

    RESULTS: Fifty-four of 667 patients with non-variceal bleeding did not respond to endoscopic treatment. Nine of the 54 patients had incomplete data, leaving 45 patients in the study; 24 had angiography and another 21 had surgery. The two groups were broadly similar in terms of relevant clinical variables. Nineteen of 24 having angiography had embolisation. Re-bleeding recurred in 8 patients (33%) in the TAE group and 6 patients (28.6%) in the surgery group (p = 0.28). There was no statistically significant difference in post procedural complications (81% vs 62.5%, p = 0.17), 30-day mortality (33% vs 29.1%, p = 0.17 ) units of blood transfused (12.24 vs 8.92, p = 0.177) and mean hospital stay (30.7 vs 22.9 days, p = 0.281) observed in patients undergoing surgery as compared to TAE.

    CONCLUSIONS: TAE and surgery have similar outcomes in patients with endoscopically unmanageable non-variceal upper gastrointestinal haemorrhage.
    Matched MeSH terms: Angiography*
  2. Sabarudin A, Yusof MZ, Mohamad M, Sun Z
    Radiat Prot Dosimetry, 2014 Dec;162(3):316-21.
    PMID: 24255172 DOI: 10.1093/rpd/nct280
    A study on the radiation dose associated with cerebral CT angiography (CTA) and CT perfusion (CTP) was conducted on an anthropomorphic phantom with the aim of estimating the effective dose (E) and entrance skin dose (ESD) in the eyes and thyroid gland during different CTA and CTP protocols. The E was calculated to be 0.61 and 0.28 mSv in CTA with 100 and 80 kV(p), respectively. In contrast, CTP resulted in an estimated E of 2.74 and 2.07 mSv corresponding to 40 and 30 s protocols, respectively. The eyes received a higher ESD than the thyroid gland in all of these protocols. The results of this study indicate that combining both CTA and CTP procedures are not recommended in the stroke evaluation due to high radiation dose. Application of modified techniques in CTA (80 kV(p)) and CTP (30 s) is highly recommended in clinical practice for further radiation dose reduction.
    Matched MeSH terms: Cerebral Angiography/methods*
  3. Abu Bakar N, Abdul Aziz YF, Singh Sandhu R, Fadzli F, Yaakub NA, Krishnasamy S, et al.
    Heart Lung Circ, 2013 Apr;22(4):305-8.
    PMID: 22921797 DOI: 10.1016/j.hlc.2012.07.016
    Pericardial cysts are uncommon mediastinal lesions that are usually congenital in origin. Patients are usually asymptomatic and the cysts are generally discovered on routine radiography for unrelated purposes. This case illustrates a symptomatic presentation of a haemorrhagic pericardial cyst in which radiographic, echocardiographic and multislice (MRI and CT) imaging were performed. The imaging findings were not typical of pericardial cysts leading to a diagnostic quandary despite the varied imaging techniques. In conclusion, it is important to appreciate that the imaging findings of pericardial cysts can be varied. Radiologists and clinicians alike should be aware of this variability.
    Matched MeSH terms: Magnetic Resonance Angiography/methods
  4. Ying CK, Kandaiya S
    J Radiol Prot, 2010 Sep;30(3):585-96.
    PMID: 20826892 DOI: 10.1088/0952-4746/30/3/012
    Interventional cardiology (IC) procedures are known to give high radiation doses to patients and cardiologists as they involve long fluoroscopy times and several cine runs. Patients' dose measurements were carried out at the cardiology department in a local hospital in Penang, Malaysia, using Gafchromic XR-RV2 films. The dosimetric properties of the Gafchromic film were first characterised. The film was energy and dose rate independent but dose dependent for the clinically used values. The film had reproducibility within ± 3% when irradiated on three different days and hence the same XR-RV2 dose-response calibration curve can be used to obtain patient entrance skin dose on different days. The increase in the response of the film post-irradiation was less than 4% over a period of 35 days. For patient dose measurements, the films were placed on the table underneath the patient for an under-couch tube position. This study included a total of 44 patients. Values of 35-2442 mGy for peak skin dose (PSD) and 10.9-344.4 Gy cm(2) for dose-area product (DAP) were obtained. DAP was found to be a poor indicator of PSD for PTCA procedures but there was a better correlation (R(2) = 0.7344) for CA + PTCA procedures. The highest PSD value in this study exceeded the threshold dose value of 2 Gy for early transient skin injury recommended by the Food and Drug Administration.
    Matched MeSH terms: Coronary Angiography*
  5. Vashu R, Tan S, Wong AS
    J Clin Neurosci, 2009 Jul;16(7):960-2.
    PMID: 19346131 DOI: 10.1016/j.jocn.2008.09.013
    We report on two patients with intra-operative rupture of cerebral aneurysms that were managed by microsuturing. This is one of only a few reports of successful direct repair using suturing. We found that stitching remains an option to repair a tear of a saccular part of an aneurysm and a torn neck of a blister-like aneurysm, and thus this technique can be considered before sacrificing the artery.
    Matched MeSH terms: Angiography/methods
  6. Chang LK, Liew NS, Soh HL, Tan SZ, Wong SH
    Med J Malaysia, 2008 Jun;63(2):131-6.
    PMID: 18942299 MyJurnal
    CT angiography (CTA) is a fast examination performed with a time-optimised contrast injection to enhance the cerebral arteries. Being a new imaging modality in our hospital, evaluation of the effectiveness of 64-row multislice CTA in detecting intracranial aneurysms in ruptured subarachnoid haemorrhage (SAH) cases is necessary. We conducted a descriptive prospective study by recruiting 30 consecutively operated SAH cases from May 2005 until November 2006. CTA findings were studied by radiologist and neurosurgeon and these were compared with operative findings. The sensitivity and specificity of CTA were 94.4% and 97.2% respectively. Approximately half of the patients were scanned within four hours and operated within 24 hours. In conclusion, CTA proves to be highly sensitive and specific in the diagnosis of intracranial aneurysms in our study.
    KEY WORDS: Subarachnoid haemorrhage, Intracranial aneurysm, Computed tomography (CT), CT angiography (CTA), Sarawak
    Matched MeSH terms: Angiography/methods*
  7. Sim KH, Ong TK, Chin SP, Wong M
    Indian Heart J, 2007 Mar-Apr;59(2 Suppl B):B25-32.
    PMID: 19153433
    Matched MeSH terms: Coronary Angiography/methods*
  8. Abu Bakar I, Shuaib IL, Mohd Ariff AR, Naing NN, Abdullah JM
    Asian J Surg, 2005 Jan;28(1):1-6.
    PMID: 15691788
    OBJECTIVE: Spontaneous intracranial haemorrhage constitutes 18-40% of all stroke cases. Indications for cerebral angiography to find underlying potentially treatable vascular abnormalities are not clear. This study determined which intracranial haemorrhage patients need cerebral angiography by correlating computed tomography (CT) findings, age and hypertension history with cerebral angiography findings.

    METHODS: A total of 54 patients (8-79 years) with intracranial haemorrhage who underwent both CT examination and six-vessel cerebral angiography were studied over a 2-year period. Cerebral angiography was repeated within 6 weeks if the first angiogram was negative.

    RESULTS: Angiography detected vascular lesions in 50% of cases (aneurysm 38.9% and arteriovenous malformation, AVM, 11.1%). In the aneurysm group, angiographic yield was 34.3% whereas in the AVM group, it was 37.9%. Subarachnoid haemorrhage (SAH) combined with other types of haemorrhage (such as intracerebral haemorrhage, ICH) was not significantly correlated with the likelihood of finding a vascular lesion, both aneurysm and AVM (p = 0.157). Age less than 50 years had significant correlation (p = 0.021) in the AVM group as well as in the aneurysm group (p < 0.001). A history of hypertension was associated with both aneurysm (p = 0.039) and AVM (p = 0.008). No patients with deep intracerebral haematoma had vascular lesions. The presence of an intravascular haemorrhage (IVH) had significant correlation with aneurysm (p = 0.008) but not AVM. There was no significant difference in mean age between patients with and without a vascular lesion (p = 0.134).

    CONCLUSION: Cerebral angiography is justified in patients with ICH accompanied by pure SAH (p = 0.001). Other factors associated with finding a vascular lesion were a history of hypertension and the presence of IVH. Diagnostic cerebral angiography is indicated for patients with ICH and SAH and IVH with a history of hypertension, regardless of age.

    Matched MeSH terms: Cerebral Angiography*
  9. Tan SP, Bux SI, Kumar G, Razack AH, Chua CB, Lee SH, et al.
    Transplant Proc, 2004 Sep;36(7):1914-6.
    PMID: 15518697
    Catheter angiography is traditionally used to determine renal arterial anatomy in live renal donors. Three-dimensional (3D) contrast-enhanced magnetic resonance imaging (MRA) has been suggested as a noninvasive replacement. We assessed the possibility of using MRA in live renal donors in Malaysia.
    Matched MeSH terms: Magnetic Resonance Angiography/methods*
  10. Chee KH, Siaw FS, Chan CG, Chong WP, Imran ZA, Haizal HK, et al.
    Int J Clin Pract, 2005 Jun;59(6):628-31.
    PMID: 15924588
    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
    Matched MeSH terms: Coronary Angiography/methods
  11. Shyam Sunder R, Eswaran C, Sriraam N
    Comput Biol Med, 2006 Sep;36(9):958-73.
    PMID: 16026779
    In this paper, 3-D discrete Hartley transform is applied for the compression of two medical modalities, namely, magnetic resonance images and X-ray angiograms and the performance results are compared with those of 3-D discrete cosine and Fourier transforms using the parameters such as PSNR and bit rate. It is shown that the 3-D discrete Hartley transform is better than the other two transforms for magnetic resonance brain images whereas for the X-ray angiograms, the 3-D discrete cosine transform is found to be superior.
    Matched MeSH terms: Angiography*
  12. Tan JH, Acharya UR, Chua KC, Cheng C, Laude A
    Med Phys, 2016 May;43(5):2311.
    PMID: 27147343 DOI: 10.1118/1.4945413
    The authors propose an algorithm that automatically extracts retinal vasculature and provides a simple measure to correct the extraction. The output of the method is a network of salient points, and blood vessels are drawn by connecting the salient points using a centripetal parameterized Catmull-Rom spline.
    Matched MeSH terms: Angiography/methods*
  13. Safari MJ, Wong JH, Kadir KA, Thorpe NK, Cutajar DL, Petasecca M, et al.
    Eur Radiol, 2016 Jan;26(1):79-86.
    PMID: 26002131 DOI: 10.1007/s00330-015-3818-9
    OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures.

    METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.

    RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.

    CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.

    KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

    Matched MeSH terms: Cerebral Angiography/methods*
  14. Moosavi Tayebi R, Wirza R, Sulaiman PS, Dimon MZ, Khalid F, Al-Surmi A, et al.
    J Cardiothorac Surg, 2015;10:58.
    PMID: 25896185 DOI: 10.1186/s13019-015-0249-2
    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography.
    Matched MeSH terms: Coronary Angiography/methods*
  15. Ho CK
    Med J Malaysia, 2001 Sep;56(3):313-8.
    PMID: 11732076
    This is a prospective study with the objective of comparing Three Dimensional (3D) Dynamic Subtraction Contrast Enhanced Magnetic Resonance Angiography (3DDSCEMRA) with Conventional Catheter Arteriography (CCA) as the gold standard, in the diagnosis of peripheral occlusive disease. Three patients scheduled for CCA in this hospital in between September and October 2000 were included in this study. Patients underwent 3DDSCEMRA before proceeding to CCA on the same day. The 3DDSCEMRA reader was blinded to the CCA results. The results showed good correlation in iliofemoral segment and poor correlation in the infrapopliteal segment due to artifacts in 3DDSCEMRA images. 3DDSCEMRA is a new, non-invasive and promising technique in the diagnosis of peripheral occlusive disease.
    Matched MeSH terms: Magnetic Resonance Angiography*
  16. Tajfard M, Tavakoly Sany SB, Avan A, Latiff LA, Rahimi HR, Moohebati M, et al.
    J Cell Physiol, 2019 07;234(7):10289-10299.
    PMID: 30548615 DOI: 10.1002/jcp.27945
    Serum high-sensitivity C-reactive protein (hs-CRP) is predictive of coronary artery disease (CAD). The aim of this study was to examine the possible association of hs-CRP with presence and severity of CAD and traditional CAD risk factors. This case-control study was carried out on 2,346 individuals from September 2011 to May 2013. Of these 1,187 had evidence of coronary disease, and were subject to coronary angiography, and the remainder were healthy controls (n = 1,159). Characteristics were determined using standard laboratory techniques and serum Hs-CRP levels were estimated using enzyme-linked immunosorbent assay (ELISA) kits, and severity of CAD was assessed according to the score of obstruction in coronary artery. Serum hs-CRP levels were higher in those with severe coronary disease, who had stenosis ≥ 50% stenosis of at least one coronary artery (all p 
    Matched MeSH terms: Coronary Angiography/methods
  17. Karim MKA, Sabarudin A, Muhammad NA, Ng KH
    Radiol Phys Technol, 2019 Dec;12(4):374-381.
    PMID: 31468370 DOI: 10.1007/s12194-019-00532-8
    This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.
    Matched MeSH terms: Computed Tomography Angiography/instrumentation*
  18. Lim CW, Cheng J, Tay ELT, Teo HY, Wong EPY, Yong VKY, et al.
    BMC Ophthalmol, 2018 Dec 10;18(1):315.
    PMID: 30526537 DOI: 10.1186/s12886-018-0976-y
    BACKGROUND: Despite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements.

    METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability.

    RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%.

    CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system.

    TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.

    Matched MeSH terms: Fluorescein Angiography/methods