Displaying publications 81 - 100 of 136 in total

Abstract:
Sort:
  1. Choudhari P, Padia D
    Malays Orthop J, 2018 Nov;12(3):38-42.
    PMID: 30555645 DOI: 10.5704/MOJ.1811.008
    Introduction: Plating in distal tibia fractures are associated with higher rate of soft tissue complications. As adequate soft tissue cover is available over anterolateral surface of the tibia, use of anterolateral plate fixation in distal tibia fractures has increased. The purpose of our research is to evaluate the outcomes of anterolateral locking plate fixation in distal tibia fractures using ORIF. Materials and Methods: A retrospective analysis of 25 patients, who had distal tibia fractures and underwent open reduction and anterolateral plating. Bone and soft tissue healing and complications encountered were analysed. Result: Full weight bearing was allowed at an average of 5.4 months (range: 3-12 months) after seeing radiological union. We have observed superficial wound infection in four cases. Two cases had marginal necrosis, two cases had sensory disturbance over dorsolateral aspect of foot and two cases had delayed non-union. Mean length of surgical incision was 9cm (range: 5-12 cm). Conclusion: Open reduction internal fixation of distal tibia fractures with anterolateral plating is a reliable way of fracture fixation and stabilisation with proper surgical technique and aseptic precautions.
    Matched MeSH terms: Tibia; Tibial Fractures
  2. Al-Chalabi MMM, Wan Sulaiman WA
    Cureus, 2021 Jan 21;13(1):e12834.
    PMID: 33633877 DOI: 10.7759/cureus.12834
    Tibial hemimelia is a relatively rare congenital tibial longitudinal deficiency (approximately 1 per 1 million live births), unilateral or bilateral, with a relatively intact fibula. Hemimelia results from a disruption of the lower limb developmental field during embryogenesis due to slow or even abort of chondrification process, which results in leg length discrepancy. Affected leg commonly appears short and deformed with knee, ankle, and foot involvement. It may present with a variety of associated anomalies. Surgical treatment varies according to the type and degree of deformity, and reconstructive interventions are still limited. Reported cases of tibial hemimelia are very infrequent, especially tibial hemimelia in twins. Usually, the cases were in single embryo or less frequently in one of the monozygotic twins, but no reported cases regarding tibial hemimelia in one of the dizygotic twins as this article reports.
    Matched MeSH terms: Tibia
  3. Nur Aishah Jusnaidi, Nurul Fadhlina Ismail
    MyJurnal
    Assessing the repeat rate is crucial to reduce unnecessary dose to the patient by identifying the major cause for repeating the x-rays exposure to the patient and apply corrective measures. To analyse the repeat rate of routine lower limb projections in direct digital radiography (DR) from general radiology department of Pantai Klang Hospital. 26 months retrospective repeated radiograph was acquired from Picture Archiving and Communication System (PACS) at Hospital Pantai Klang. The retrieved radiographs were grouped based on the reason for the i radiographs being rejected which are incorrect positioning, incorrect collimation, patient movement, incorrect exposure factors, artefact, and other reasons. Total repeated radiographs retrieved for basic lower limbs projections were 13616. Knee was the highest repeted examination and the lowest repeat rate was tibia fibula. (repeat rate: knee = 1.04%, tibia fibula = 0.57%). incorrect positioning is the major causes for repeat exposure for all examinations type, followed by incorrect collimation, other categories, centring ray error, incorrect exposure factors and artifact.
    Matched MeSH terms: Tibia
  4. Che Nor Zarida Che Seman, Zamzuri Zakaria
    MyJurnal
    Critical size defects (CSD) in the long bones of New Zealand White rabbits (Oryctolagus cuniculus) have been used for years as an experimental model for investigation of the effectiveness of a new bone substitute material. There are varieties of protocols available in the literature. This technical note attempts to present an alternative surgical technique of a CSD in the New Zealand white rabbit tibia. Methods: Thirty-nine New Zealand White rabbits were used in this study. A CSD of approximately 4.5 mm (width) X 9.0 mm (length) was surgically drilled at the proximal tibial metaphysis, approximately 1 cm from the knee joint. The surrounding of soft tissue was repositioned and sutured layer by layer with bioabsorbable surgical suture. Two x-rays of anteroposterior and lateral were taken before assessed under computed tomography scan at 6, 12 and 24 weeks. Results: This alternative method created CSD with less bleeding from the muscle observed. No mortality or other surgical complications observed within 6 weeks, 12 weeks and 24 weeks following surgery. Conclusion: A simple and safe method for performing CSD was demonstrated and recommended as an alternative approach for surgery on New Zealand White rabbits.
    Matched MeSH terms: Tibia
  5. Fahad S, Habib AA, Awais MB, Umer M, Rashid HU
    Malays Orthop J, 2019 Mar;13(1):36-41.
    PMID: 31001382 DOI: 10.5704/MOJ.1903.006
    Introduction: Tibia is the most common long bone fractured due its vulnerable subcutaneous location and most often associated with acquired complications of delayed union or non-union due to infection. Amongst the various treatment options to treat them, the Ilizarov external fixator application is considered superior due to its multiple advantages. The objective of this study was to analyse the role of Ilizarov fixation in infected tibial non-union, as well as to assess bony union and associated functional outcomes. Materials and Methods: A retrospective review was conducted for the duration between 1st January 2005 to 31st December 2016. Total of fifty-one patients with tibial non-union associated with infection who treated with the Ilizarov fixator were included in the study. Patient records were reviewed for union of bone, bone and functional outcomes and complications. Results: The most common organism for infection was identified to be Staphylococcus Aureus. At the time of final follow-up all patients had achieved union except two, one of whom had to undergo amputation due to non-union and sepsis. Majority of the patients had an excellent score as per ASAMI grading system for bone and function results. The most common complication noted was pin track infections. Conclusion: In our experience, Ilizarov external fixator is better suited for infected non-union of tibia because it can provide a stable mechanical environment, bone transport, correct deformities, and enable weight bearing and hence we recommend its use for the same.
    Matched MeSH terms: Tibia
  6. Mudiganty S, Austine J
    Malays Orthop J, 2021 Mar;15(1):27-31.
    PMID: 33880145 DOI: 10.5704/MOJ.2103.005
    Introduction: Distraction osteogenesis has been used effectively in the management of tibia non-unions with skeletal defect. A retrospective case series study of the infected non-union tibia managed with acute docking in a rail fixation system was conducted at a tertiary care hospital in South India. It was designed to evaluate the use of autologous bone graft at the docking site in achieving an early union with a seven years follow-up period.

    Materials and Methods: From 2010 to 2017, a total of 19 patients with infected tibia non-union and a bone defect less than 3cm, were treated with debridement and a monolateral frame fixation with acute shortening and lengthening. The patients were divided into two groups: one in which no bone graft was used at the docking site during early years of the study; and a later group in which autologous bone graft was used at the acute docking site primarily in addition to compression. Consolidation at the docking site was assessed both radiographically and clinically, and the results were statistically analysed.

    Results: There were 12 patients in Group I without bone graft, where consolidation at the docking site was noted after a mean duration of 22.08 ± 3.87 weeks. There were seven patients in Group II with bone graft, where the mean time for docking site consolidation was significantly lower at 16.57 ± 3.82 weeks. No docking site complications were noted in either group.

    Conclusion: Primary autologous bone graft enhances docking site consolidation in acute shortening. The routine use of bone graft at the docking site in acute shortening will expedite the docking site union with reduction of treatment time.

    Matched MeSH terms: Tibia
  7. Subash Y
    Malays Orthop J, 2021 Mar;15(1):48-54.
    PMID: 33880148 DOI: 10.5704/MOJ.2103.008
    Introduction: Fractures of the proximal tibia are high velocity injuries often associated with soft tissue compromise especially in the type V and VI fracture patterns. Dual plating is the preferred treatment option for these injuries but not in a setting where there is extensive soft tissue injury, as this can lead to problems with wound healing. The aim of this study was to evaluate the functional outcome following hybrid external fixation in the management of Schatzkers type V and VI fractures.

    Materials and Methods: A total of 30 patients with type V and VI proximal tibial fractures who presented between January 2012 to January 2015 were managed with hybrid external fixation and were followed-up for a period of 3 years.

    Results: The mean age of the patients was 42.26 years with the left knee being more commonly affected. Schatzkers type V was the more common fracture type seen. The mean time to union was 12.06 weeks and the average range of motion achieved was 0 to 100°. The mean Rasmussens functional score was 25.4 at last follow-up and we had excellent results in 5 patients and good results in 22 patients.

    Conclusion: Through this study, we conclude that the hybrid external fixation is an excellent option in the type V and VI fractures with extensive soft tissue compromise. It is easy to apply, facilitates early mobilisation of the joint and gives good functional results.

    Matched MeSH terms: Tibia; Tibial Fractures
  8. Murugan K, Faisham WI, Zulmi W
    Malays Orthop J, 2021 Mar;15(1):93-99.
    PMID: 33880154 DOI: 10.5704/MOJ.2103.014
    Introduction: Mega endoprosthesis replacement for resection of primary malignant bone tumour requires immediate and long-term stability, particularly in the young and active patient. Extracortical bone bridge interface (EBBI) is a technique whereby autograft is wrapped around the interface junction of bone and porous-coated implant to induce and enhance bone formation for biological incorporation. This procedure increases the mean torsional stiffness and the mean maximum torque, which eventually improves the implant's long-term survival.

    Material and methods: The extracortical bone bridge interface's radiological parameter was evaluated at the prosthesis bone junction two years after surgery utilising a picture archiving and communication system (PACS). The radiograph's anteroposterior and lateral view was analysed for both thickness and length in all four cortices. The analysis was done in SPSS Version 24 using One-Way ANOVA and independent T-Test. Results were presented as mean and standard deviation and considered significant when the p-value was < 0.05.

    Results: The mean average thickness was 2.2293mm (SD 1.829), and the mean average length was 31.95% (SD 24.55). We observed that the thickness and length of EBBI were superior in the young patient or patients with giant cell tumour that did not receive chemotherapy, compared to patients treated for osteosarcoma. The distal femur also had better EBBI compared to the proximal tibia. However, the final multivariable statistical analysis showed no significant difference in all variables. EBBI thickness was significantly and positively correlated with EBBI Length (p<0.001). We conclude that, for each 1mm increase in EBBI thickness, the length will increase by 0.06% on average. About 17.2% of patients out of the 29 showed no radiological evidence of EBBI.

    Conclusion: From our study, there were no factors that significantly contributed to the formation and incorporation of EBBI.

    Matched MeSH terms: Tibia
  9. Mohamed Abdelrasoul, Jahangir Bin Kamaldin, Jer Ping Ooi, Ahmed Abd El-Fattah, Gihan Kotry, Omneya Ramadan, et al.
    MyJurnal
    Introduction: Melatonin (MEL) loaded alginate-chitosan/beta-tricalcium phosphate (Alg-CH/β-TCP) composite hy- drogel has been formulated as a scaffold for bone regeneration. MEL in the scaffold was anticipated to accelerate bone regeneration. The objective of this study is to observe signs of systemic toxicity and physical changes on surface defected bone for bone regenerative performance of the composite. Methods: The proximal-medial metaphyseal cortex of the left tibia of New Zealand white rabbit was the surgical site of the defect. A total of nine rabbits were randomly allocated to three groups; Group I; implanted with MEL loaded Alg-CH/β-TCP, Group II; Alg-CH/β-TCP and Group III defects were sham control. The rabbits were daily observed to determine systemic toxicity effects by composites. The physical changes to implanted site were observed using digital x-ray radiography and computerized tomography at weeks 0, 2, 4, 6 and 8 of post-implantation. Results: There were no clinical signs of systemic toxicity for all groups of rabbits. Digital radiography did not show adverse effects to the bone. Computerized tomography showed reduction in the area size and depth volume of the implantation site, but accelerated regeneration within the 8 weeks was not significantly different (P
    Matched MeSH terms: Tibia
  10. Mahnon Suria Mokhy, Rosita Jamaluddin, Abd Rasyid Ismail, Woan Yie Siah, Norhasmah Sulaiman, Siti Nur ‘Asyura Adznam, et al.
    MyJurnal
    This article aimed to review the available anthropometry measurements used in the assessment of nutritional sta- tus among Cerebral Palsy (CP) children. Searched journals were from Medline, PubMed and Ovid published from 2015 to 2018. The search identified 443 articles, and eight studies met the criteria. Anthropometric measurements included weight, height, recumbent length, knee height, tibia length, Dual-energy X-ray absorptiometry (DXA), Bio- electrical impedance (BIA), Mid arm circumference (MUAC) subscapular skinfold (SFT), Triceps skinfold (TSF) and prediction equations. Body fat composition can be obtained by DXA, BIA, skinfold measurement, and also prediction equation. The predictive equation is the most reported method to determine nutritional status among CP. This review found that TSF and SFT are more accurate to determine body fat percentage when using together with the predictive equation. Besides, predictive equations using segmental length are reliable in estimating the height and can be used to evaluate the nutritional status using the specific CP growth chart.
    Matched MeSH terms: Tibia
  11. Chua, Y.C.J., Lim, L.A., Hudzairy, A.
    Malays Orthop J, 2009;3(1):91-94.
    MyJurnal
    We are reporting a case of post-traumatic chronic osteomyelitis of the tibia with an open wound exposing an intra medullar nail implant for 13 years. The patient presented with fresh ipsilateral tibia plateau fracture. He was treated by removal of the implant, debridement and local placement of Gentamicin-impregnated PMMA beads according to guidelines of two-stage Belfast technique . After five months of wound treatment, the exposed bone was covered by healthy granulation tissue and the patient was able to fully bear weight.
    Matched MeSH terms: Tibia; Tibial Fractures
  12. Pan, K.L., Chan, W.H.
    Malays Orthop J, 2010;4(2):51-53.
    MyJurnal
    Giant cell tumours of bone are best treated by extended curettage and filling in of the defect with cement or bone graft. In more advanced stages, when there is extensive loss of cortical bone cover, containment of the filling material is not possible and resection and reconstruction is required. We report a case of a recurrent giant cell tumour of the distal tibia in a 21-year-old female with extensive cortical bone loss in which polypropylene surgical mesh was used to contain the bone cement, thus avoiding a resection.
    Matched MeSH terms: Tibia
  13. Lim, W.K., Ling, H.T., R. Ramanathan
    MyJurnal
    Brush cutting is a commonly performed activity occupationally as well as recreationally in Malaysia. There are various occupational injuries reported related to brush cutting, for example foreign body penetration. There were 11 reported cases of foreign body penetrated in leg of brush cutting workers admitted to orthopaedic ward in Hospital Raja Permaisuri Bainun from the period of January till October 2009. Among the cases, 4 were surgically removed under local anaesthesia and 7 cases performed under general anesthesia. 2 cases reported foreign body penetrated into tibia bone. There were many contributing factors to the injury, which include lack of protective measures for workers, engineering property of brush cutting machine and education on handling of equipment. It is vital to study the factors separately in order to determine and recommend useful preventive measures. However, the actual numbers of cases are under reported and awareness of the problem is undermined.
    Matched MeSH terms: Tibia
  14. Amal Hayati Zainal Abidin, Khairul Osman, Sri Pawita Albakri Amir Hamzah, Noor Hazfalinda Hamzah, Ab Halim Mansar, Normaizatul Afizah Ismail
    MyJurnal
    The study was conducted to create specific formulae for stature estimation of adult male population in Malaysia based on measurements of femur, tibia and fibula lengths using radiographic method. A number of thirty two Malaysians from hospitals involved as subjects in this study. The subjects were Malays (14), Chinese (8) and Indians (10) from 25-45 years old. The standing height of the subject was recorded before femur, tibia and fibula were scanned with an x-ray
    machine. The bones length was measured on the x-ray film in centimetres (cm) and analysed using Statistical Package for Social Sciences (SPSS) version 19.0 for Windows. The results showed a significant relationship (p < 0.05) between stature and measurements of length of femur, tibia and fibula. Stature of Malays and Indians were significant (p < 0.05) with measurements of length of femur, tibia and fibula but insignificant in Chinese. Simple Linear Regression Analysis was used to derive regression equation for single bone and Multiple Linear Regression Analysis was used to derive regression equation for combination of femur, tibia and fibula. Six formulae for stature estimation of adult male population in Malaysia were derived. The formulae consist of three formulae for single bone, a formulae for combination bones with unknown race, a formulae for combination bones of Malays population and a formulae for combination bones of Indians population. Formulae for combination bones had the highest correlation coefficient compared to the formula using a single bone. Standard error was found to be high in all the formulae due to small sample size. Extension for this study is essential to provide Malaysia with accurate formulae.
    Matched MeSH terms: Tibia
  15. Tan T, Ho W
    Malays Orthop J, 2015 Nov;9(3):65-67.
    PMID: 28611915 DOI: 10.5704/MOJ.1511.010
    Stress fractures of the proximal tibia metaphysis are rare in the elderly. We present a case of a 65-year old male who developed sequential proximal tibia stress fractures associated with prolonged usage of methotrexate and prednisolone within a span of 18 months. Magnetic Resonance Imaging revealed an incomplete stress fracture involving the medial proximal tibial region. The patient was treated with stemmed total knee arthroplasty (TKA) bilaterally. Stress fractures should be considered in patients with atypical knee pain who have a history of methotrexate and prednisolone usage. TKA is an effective treatment in stress fractures of the proximal tibia.
    Matched MeSH terms: Tibia
  16. Malhotra R, Chua WL, O'Neill G
    Malays Orthop J, 2016 Nov;10(3):49-51.
    PMID: 28553450 DOI: 10.5704/MOJ.1611.014
    We present a case of a lower limb compartment syndrome associated with the use of an intra-osseous line inserted into the proximal tibia in an adult patient. An unconscious 59-year old male with multiple injuries presented to our Emergency Department after a road traffic accident. Bilateral proximal tibial intra osseous-lines were inserted due to poor venous access. After resuscitation his left leg was noted to be tense and swollen with absent pulses. Acute compartment syndrome was diagnosed both clinically and with compartment pressure measurement. Two incision fasciotomy on his left lower leg was performed. Intra osseous-lines in the proximal tibia are increasingly used in adult patients in the pre-hospital setting by paramedics and emergency physicians. Their use, along with the possible complications of these devices, such as the development of compartment syndrome or osteomyelitis leading to amputation, is well reported in the paediatric literature. To the best of our knowledge, there have not been any previous reports of complications in the adult patient. We present a case of lower leg compartment syndrome developing from the use of an intra-osseous line in the proximal tibia in an adult patient. With the increasing use of intra-osseous lines in adult patients, clinicians should be aware of the possibility of developing compartment syndrome which may lead to disability or amputation in severe cases.
    Matched MeSH terms: Tibia
  17. Solayar GN, Chinappa J, Harris IA, Chen DB, Macdessi SJ
    Malays Orthop J, 2017 Jul;11(2):45-52.
    PMID: 29021879 MyJurnal DOI: 10.5704/MOJ.1707.006
    Introduction: Optimal coronal and sagittal component positioning is important in achieving a successful outcome following total knee arthroplasty (TKA). Modalities to determine post-operative alignment include plain radiography and computer tomography (CT) imaging. This study aims to determine the accuracy and reliability of plain radiographs in measuring coronal and sagittal alignment following TKA. Materials and Methods: A prospective, consecutive study of 58 patients undergoing TKA was performed comparing alignment data from plain radiographs and CT imaging. Hip-knee-angle (HKA), sagittal femoral angle (SFA) and sagittal tibial angle (STA) measurements were taken by two observers from plain radiographs and compared with CT alignment. Intra- and inter-observer correlation was calculated for each measurement. Results: Intra-observer correlation was excellent for HKA (r>0.89) with a mean difference of <1.9°. The least intra-observer correlation was for SFA (mean r=0.58) with a mean difference of 8°. Inter-observer correlation was better for HKA (r>0.95) and STA (r>0.8) compared to SFA (r=0.5). When comparing modalities (radiographs vs CT), HKA estimations for both observers showed the least maximum and mean differences while SFA observations were the least accurate. Conclusion: Radiographic estimation of HKA showed excellent intra- and inter-observer correlation and corresponds well with CT imaging. However, radiographic estimation of sagittal plane alignment was less reliably measured and correlated less with CT imaging. Plain radiography was found to be inferior to CT for estimation of biplanar prosthetic alignment following TKA.
    Matched MeSH terms: Tibia
  18. Zayzan KR, Yusof NM, Sulong AF, Zakaria Z, Ab Rahman J
    Singapore Med J, 2020 Dec 02.
    PMID: 33264560 DOI: 10.11622/smedj.2020164
    INTRODUCTION: The clinical outcomes and factors associated with treatment failure of post-traumatic osteomyelitis have been investigated by many studies. However, limb functionality and quality of life following treatment for this condition have not been thoroughly studied.

    METHODS: This was a cross-sectional study that included 47 patients with post-traumatic osteomyelitis of the lower limb. Functional outcome was assessed using the Lower Extremity Functional Score (LEFS), and quality of life was assessed using the validated Malay version of Short Form-36 version 2.

    RESULTS: Mean follow-up time was 4.6 (range 2.3-9.5) years. Median age was 44 years. Osteomyelitis was located in the tibia for 26 patients and in the femur for 21 patients. Osteomyelitis was consequent to internal infection in 38 patients and due to infected open fractures in nine patients. 42 (89.4%) patients had fracture union and control of infection. Bone defect was found to be a significant contributing factor for treatment failure (p = 0.008). The median LEFS for the success group was 65 when compared to 49 for the failure group. Although the success group showed better scores with regard to quality of life, the difference between the two groups was not statistically significant.

    CONCLUSION: The success rate for post-traumatic osteomyelitis of the lower limb was high. The presence of a bone defect was associated with treatment failure. Successfully treated patients had significantly better functional outcomes than failed ones.

    Matched MeSH terms: Tibia
  19. Abujazia MA, Muhammad N, Shuid AN, Soelaiman IN
    PMID: 22927879 DOI: 10.1155/2012/525079
    Virgin coconut oil (VCO) was found to have antioxidant property due to its high polyphenol content. The aim of this study was to investigate the effect of the virgin coconut oil on lipid peroxidation in the bone of an osteoporotic rat model. Normal female Sprague-Dawley rats aged 3 months old were randomly divided into 4 groups, with 8 rats in each group: baseline, sham, ovariectomised (OVX) control group, and OVX given 8% VCO in the diet for six weeks. The oxidative status of the bone was assessed by measuring the index of lipid peroxidation, which is malondialdehyde (MDA) concentration, as well as the endogenous antioxidant enzymes glutathione peroxidase (GPX) and superoxide dismutase (SOD) in the tibia at the end of the study. The results showed that there was a significant decrease in MDA levels in the OVX-VCO group compared to control group. Ovariectomised rats treated with VCO also had significantly higher GPX concentration. The SOD level seemed to be increased in the OVX-VCO group compared to OVX-control group. In conclusion, VCO prevented lipid peroxidation and increased the antioxidant enzymes in the osteoporotic rat model.
    Matched MeSH terms: Tibia
  20. Sulaiman AR, Simbak N, Wan Ismail WF, Wan Z, Halim AS
    J Orthop Surg (Hong Kong), 2011 Aug;19(2):250-3.
    PMID: 21857057
    We report 2 patients with congenital pseudoarthrosis of the tibia who underwent intramedullary Rush rod transfixation through the ankle joint following refracture and nonunion of vascularised fibular grafting 6 and 8 months earlier. After 9 and 5 years, both Rush rods were broken at the level of the ankle joints, while the reconstructed area was solidly united. The growth of the distal tibia increased the distance of the tips of the broken rod and hence the ankle joint motion. The broken tips may damage the articular cartilage and result in valgus deformity of the ankle and limb length discrepancy.
    Matched MeSH terms: Tibia/physiopathology; Tibial Fractures/congenital*; Tibial Fractures/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links