Displaying publications 81 - 100 of 212 in total

Abstract:
Sort:
  1. Iqbal U, Wah TY, Habib Ur Rehman M, Mujtaba G, Imran M, Shoaib M
    J Med Syst, 2018 Nov 05;42(12):252.
    PMID: 30397730 DOI: 10.1007/s10916-018-1107-2
    Electrocardiography (ECG) sensors play a vital role in the Internet of Medical Things, and these sensors help in monitoring the electrical activity of the heart. ECG signal analysis can improve human life in many ways, from diagnosing diseases among cardiac patients to managing the lifestyles of diabetic patients. Abnormalities in heart activities lead to different cardiac diseases and arrhythmia. However, some cardiac diseases, such as myocardial infarction (MI) and atrial fibrillation (Af), require special attention due to their direct impact on human life. The classification of flattened T wave cases of MI in ECG signals and how much of these cases are similar to ST-T changes in MI remain an open issue for researchers. This article presents a novel contribution to classify MI and Af. To this end, we propose a new approach called deep deterministic learning (DDL), which works by combining predefined heart activities with fused datasets. In this research, we used two datasets. The first dataset, Massachusetts Institute of Technology-Beth Israel Hospital, is publicly available, and we exclusively obtained the second dataset from the University of Malaya Medical Center, Kuala Lumpur Malaysia. We first initiated predefined activities on each individual dataset to recognize patterns between the ST-T change and flattened T wave cases and then used the data fusion approach to merge both datasets in a manner that delivers the most accurate pattern recognition results. The proposed DDL approach is a systematic stage-wise methodology that relies on accurate detection of R peaks in ECG signals, time domain features of ECG signals, and fine tune-up of artificial neural networks. The empirical evaluation shows high accuracy (i.e., ≤99.97%) in pattern matching ST-T changes and flattened T waves using the proposed DDL approach. The proposed pattern recognition approach is a significant contribution to the diagnosis of special cases of MI.
    Matched MeSH terms: Electrocardiography/methods*
  2. Sabarudin A, Siong TW, Chin AW, Hoong NK, Karim MKA
    Sci Rep, 2019 03 13;9(1):4374.
    PMID: 30867480 DOI: 10.1038/s41598-019-40758-5
    In this report we have evaluated radiation effective dose received by patients during ECG-gated CCTA examinations based on gender, heart rate, tube voltage protocol and body mass index (BMI). A total of 1,824 patients were retrospectively recruited (1,139 men and 685 women) and they were divided into Group 1 (CCTA with calcium scoring), Group 2 (CCTA without calcium scoring) and Group 3 (only calcium scoring), where the association between gender, heart rate, tube voltage protocol and body mass index (BMI) were analysed. Examinations were performed using a retrospective ECG-gated CCTA protocol and the effective doses were calculated from the dose length product with a conversion coefficient of 0.026 mSv.mGy-1cm-1. No significant differences were observed in the mean effective dose between gender in all groups. The mean estimated dose was significantly higher when the heart rate was lower in Group 1 (p 
    Matched MeSH terms: Electrocardiography*
  3. Wong A, Abu Bakar MZ
    Am J Otolaryngol, 2021 01 04;42(2):102869.
    PMID: 33429183 DOI: 10.1016/j.amjoto.2020.102869
    PURPOSE: The nasocardiac reflex is known but not well researched. We aimed to ascertain the electrocardiographic features of the reflex and to chronologically map the heart rhythm dynamics during nasoendoscopy. We also intended to identify variables that could potentially affect the occurrence of this reflex.

    MATERIAL AND METHODS: A prospective, quasi-experimental physiological study. Selected healthy subjects were observed electrocardiographically for 60 s continuously in three equal phases of 20 s each - baseline phase, nasoendoscopic phase, and recovery phase (post-nasoendoscopy). Heart rate fluctuations were charted, followed by identification of a positive nasocardiac reflex group of subjects and a negative group. Analyses against multiple variables were done.

    RESULTS: A total of 53 subjects were analysed. Heart rate during the baseline phase was 81.0 ± 9.9, nasoendoscopic phase was 72.7 ± 10.1, and recovery phase was 75.2 ± 9.6. Sixteen subjects (30.2%) had a positive nasocardiac reflex, and they remained in sinus rhythm with no occurrences of skipped beats, atrioventricular blocks or asystoles. One subject (1.9%) developed temporary ectopic premature ventricular contractions after nasoendoscopy. No variables were found affecting the incidence of a nasocardiac reflex in our study.

    CONCLUSIONS: The pattern of heart rate dynamics was consistent as heart rates drop rapidly upon endoscope insertion and recover in some measure after its withdrawal. Although all our subjects remained asymptomatic, clinicians should not overlook the risks of a severe nasocardiac reflex when performing nasoendoscopy. We recommend that electrical cardiac monitoring be part of the management of vasovagal responses during in-office endonasal procedures.

    Matched MeSH terms: Electrocardiography*
  4. Abdul-Kadir NA, Mat Safri N, Othman MA
    Int J Cardiol, 2016 Nov 01;222:504-8.
    PMID: 27505342 DOI: 10.1016/j.ijcard.2016.07.196
    BACKGROUND: The feasibility study of the natural frequency (ω) obtained from a second-order dynamic system applied to an ECG signal was discovered recently. The heart rate for different ECG signals generates different ω values. The heart rate variability (HRV) and autonomic nervous system (ANS) have an association to represent cardiovascular variations for each individual. This study further analyzed the ω for different ECG signals with HRV for atrial fibrillation classification.

    METHODS: This study used the MIT-BIH Normal Sinus Rhythm (nsrdb) and MIT-BIH Atrial Fibrillation (afdb) databases for healthy human (NSR) and atrial fibrillation patient (N and AF) ECG signals, respectively. The extraction of features was based on the dynamic system concept to determine the ω of the ECG signals. There were 35,031 samples used for classification.

    RESULTS: There were significant differences between the N & NSR, N & AF, and NSR & AF groups as determined by the statistical t-test (p<0.0001). There was a linear separation at 0.4s(-1) for ω of both databases upon using the thresholding method. The feature ω for afdb and nsrdb falls within the high frequency (HF) and above the HF band, respectively. The feature classification between the nsrdb and afdb ECG signals was 96.53% accurate.

    CONCLUSIONS: This study found that features of the ω of atrial fibrillation patients and healthy humans were associated with the frequency analysis of the ANS during parasympathetic activity. The feature ω is significant for different databases, and the classification between afdb and nsrdb was determined.

    Matched MeSH terms: Electrocardiography/classification*
  5. Piccini JP, Stromberg K, Jackson KP, Laager V, Duray GZ, El-Chami M, et al.
    Heart Rhythm, 2017 05;14(5):685-691.
    PMID: 28111349 DOI: 10.1016/j.hrthm.2017.01.026
    BACKGROUND: Device repositioning during Micra leadless pacemaker implantation may be required to achieve optimal pacing thresholds.

    OBJECTIVE: The purpose of this study was to describe the natural history of acute elevated Micra vs traditional transvenous lead thresholds.

    METHODS: Micra study VVI patients with threshold data (at 0.24 ms) at implant (n = 711) were compared with Capture study patients with de novo transvenous leads at 0.4 ms (n = 538). In both cohorts, high thresholds were defined as >1.0 V and very high as >1.5 V. Change in pacing threshold (0-6 months) with high (1.0 to ≤1.5 V) or very high (>1.5 V) thresholds were compared using the Wilcoxon signed-rank test.

    RESULTS: Of the 711 Micra patients, 83 (11.7%) had an implant threshold of >1.0 V at 0.24 ms. Of the 538 Capture patients, 50 (9.3%) had an implant threshold of >1.0 V at 0.40 ms. There were no significant differences in patient characteristics between those with and without an implant threshold of >1.0 V, with the exception of left ventricular ejection fraction in the Capture cohort (high vs low thresholds, 53% vs 58%; P = .011). Patients with an implant threshold of >1.0 V decreased significantly (P < .001) in both cohorts. Micra patients with high and very high thresholds decreased significantly (P < .01) by 1 month, with 87% and 85% having 6-month thresholds lower than the implant value. However, when the capture threshold at implant was >2 V, only 18.2% had a threshold of ≤1 V at 6 months and 45.5% had a capture threshold of >2 V.

    CONCLUSIONS: Pacing thresholds in most Micra patients with elevated thresholds decrease after implant. Micra device repositioning may not be necessary if the pacing threshold is ≤2 V.

    Matched MeSH terms: Electrocardiography*
  6. Wickramatilake CM, Mohideen MR, Pathirana C
    Indian Heart J, 2017 02 12;69(2):291.
    PMID: 28460787 DOI: 10.1016/j.ihj.2017.02.002
    Matched MeSH terms: Electrocardiography*
  7. Ong ML, Hatle LK, Lai VM, Bosco J
    Int J Clin Pract, 2002 Jun;56(5):345-8.
    PMID: 12137442
    Iron deposition in the heart occurs in beta-thalassaemia major and contributes to cardiac dysfunction. Eighteen patients with beta-thalassaemia major were assessed clinically and had non-invasive investigations. They were young (15.5 +/- 3.6 years). Two patients had clinical heart failure. Doppler echocardiography demonstrated higher transmitral peak flow velocity in early and late diastole compared with controls (e: p<0.05, a: p<0.01). Transtricuspid peak late diastolic flow velocity was higher in patients (p<0.005). Isovolumic relaxation time was shortened (p<0.001). Pulmonary venous flow velocity was higher in diastole than systole (S: 0.51 +/- 0.11 m/s, D: 0.62 +/- 0.08 m/s). Reversal of pulmonary venous flow during atrial systole was seen in eight patients. These diastolic filling abnormalities did not significantly change with blood transfusion. Left ventricular ejection fraction was normal in patients. Two patients had cardiomegaly on chest X-ray. In beta-thalassaemia with iron overload, there is a restrictive pattern of diastolic dysfunction. This is not altered by recent blood transfusion. Left ventricular function remains relatively intact.
    Matched MeSH terms: Electrocardiography/standards
  8. Selvaraj J, Murugappan M, Wan K, Yaacob S
    Biomed Eng Online, 2013;12:44.
    PMID: 23680041 DOI: 10.1186/1475-925X-12-44
    Identifying the emotional state is helpful in applications involving patients with autism and other intellectual disabilities; computer-based training, human computer interaction etc. Electrocardiogram (ECG) signals, being an activity of the autonomous nervous system (ANS), reflect the underlying true emotional state of a person. However, the performance of various methods developed so far lacks accuracy, and more robust methods need to be developed to identify the emotional pattern associated with ECG signals.
    Matched MeSH terms: Electrocardiography/methods*
  9. Bakar AA, Lim YL, Wilson SJ, Fuentes M, Bertling K, Taimre T, et al.
    Physiol Meas, 2013 Feb;34(2):281-9.
    PMID: 23363933 DOI: 10.1088/0967-3334/34/2/281
    Optical sensing offers an attractive option for detection of surface biopotentials in human subjects where electromagnetically noisy environments exist or safety requirements dictate a high degree of galvanic isolation. Such circumstances may be found in modern magnetic resonance imaging systems for example. The low signal amplitude and high source impedance of typical biopotentials have made optical transduction an uncommon sensing approach. We propose a solution consisting of an electro-optic phase modulator as a transducer, coupled to a vertical-cavity surface-emitting laser and the self-mixing signal detected via a photodiode. This configuration is physically evaluated with respect to synthesized surface electrocardiographic (EKG) signals of varying amplitudes and using differing optical feedback regimes. Optically detected EKG signals using strong optical feedback show the feasibility of this approach and indicate directions for optimization of the electro-optic transducer for improved signal-to-noise ratios. This may provide a new means of biopotential detection suited for environments characterized by harsh electromagnetic interference.
    Matched MeSH terms: Electrocardiography/instrumentation*
  10. Wong KI, Ho MM
    PMID: 19162703 DOI: 10.1109/IEMBS.2008.4649200
    Extended patient monitoring has become increasingly important for detection of cardiac conditions, such as irregularities in the rhythms of the heart, while patient is practicing normal daily activity. This paper presents a design of a single lead wireless cardiac rhythm interpretive instrument that capable of capture the electrocardiogram (ECG) in digital format and transmitted to a remote base-station (i.e. PC) for storage and further interpretation. The design has achieved high quality of ECG and free of interference in the presence of motion.
    Matched MeSH terms: Electrocardiography, Ambulatory/instrumentation*
  11. Malarvili MB, Mesbah M
    IEEE Trans Biomed Eng, 2009 Nov;56(11):2594-603.
    PMID: 19628449 DOI: 10.1109/TBME.2009.2026908
    In this paper, we investigate the use of heart rate variability (HRV) for automatic newborn seizure detection. The proposed method consists of a sequence of processing steps, namely, obtaining HRV from the ECG, extracting a discriminating HRV feature set, selecting an optimal subset from the full feature set, and, finally, classifying the HRV into seizure/nonseizure using a supervised statistical classifier. Due to the fact that HRV signals are nonstationary, a set of time-frequency features from the newborn HRV is proposed and extracted. In order to achieve efficient HRV-based automatic newborn seizure detection, a two-phase wrapper-based feature selection technique is used to select the feature subset with minimum redundancy and maximum class discriminability. Tested on ECG recordings obtained from eight newborns with identified EEG seizure, the proposed HRV-based neonatal seizure detection algorithm achieved 85.7% sensitivity and 84.6% specificity. These results suggest that the HRV is sensitive to changes in the cardioregulatory system induced by the seizure, and therefore, can be used as a basis for an automatic seizure detection.
    Matched MeSH terms: Electrocardiography/methods
  12. Moein S
    Adv Exp Med Biol, 2010;680:109-16.
    PMID: 20865492 DOI: 10.1007/978-1-4419-5913-3_13
    In this paper, application of Artificial Neural Network (ANN) for electrocardiogram (ECG) signal noise removal has been investigated. First, 100 number of ECG signals are selected from Physikalisch-Technische Bundesanstalt (PTB) database and Kalman filter is applied to remove their low pass noise. Then a suitable dataset based on denoised ECG signal is configured and used to a Multilayer Perceptron (MLP) neural network to be trained. Finally, results and experiences are discussed and the effect of changing different parameters for MLP training is shown.
    Matched MeSH terms: Electrocardiography/statistics & numerical data*
  13. Yeo CK, Hapizah MN, Khalid BAK, Wan Nazainimoon WM, Khalid Y
    Med J Malaysia, 2004 Jun;59(2):185-9.
    PMID: 15559168
    Diabetes mellitus is an important coronary artery disease risk factor. The presence of microalbuminuria, which indicates renal involvement in diabetic patients, is associated with an increased cardiovascular risk. There are suggestions that diabetic patients with microalbuminuria have more adverse risk profile such as higher ambulatory blood pressure and total cholesterol levels to account for the increased cardiovascular morbidity and mortality. QT dispersion is increasingly being recognized as a prognostic factor for coronary artery disease and sudden death. Some studies have suggested that QT dispersion is an important predictor of mortality in Type II diabetic patients. Our cross sectional study was to compare the QT dispersion and 24 hour ambulatory blood pressure monitoring between diabetic patients with microalbuminuria and those without microalbuminuria. Diabetic patients with overt coronary artery disease were excluded from the study. A total of 108 patients were recruited of which 57 patients had microalbuminuria and 51 were without microalbuminuria. The mean value of QT dispersion was significantly higher in patients with microalbuminuria than in patients without microalbuminuria (58.9 +/- 27.9 ms vs. 47.1 +/- 25.0 ms, p < 0.05). The mean 24 hour systolic and diastolic blood pressures were significantly higher in patients with microalbuminuria than in patients without microalbuminuria (129.5 +/- 12.3 mm Hg vs 122.3 +/- 10.2 mm Hg, p < 0.05 and 78.4 +/- 6.9 mm Hg vs 75.3 +/- 6.8 mm Hg, p < 0.05, respectively). Our study suggests that QT dispersion prolongation, related perhaps to some autonomic dysfunction, is an early manifestation of cardiovascular aberration in diabetic patients with microalbuminuria. The higher blood pressure levels recorded during a 24-hour period min diabetics with microalbuminuria could also possibly account for the worse cardiovascular outcome in this group of patients.
    Matched MeSH terms: Electrocardiography*
  14. Rajendra Acharya U, Faust O, Adib Kadri N, Suri JS, Yu W
    Comput Biol Med, 2013 Oct;43(10):1523-9.
    PMID: 24034744 DOI: 10.1016/j.compbiomed.2013.05.024
    Diabetes mellitus (DM) affects considerable number of people in the world and the number of cases is increasing every year. Due to a strong link to the genetic basis of the disease, it is extremely difficult to cure. However, it can be controlled to prevent severe consequences, such as organ damage. Therefore, diabetes diagnosis and monitoring of its treatment is very important. In this paper, we have proposed a non-invasive diagnosis support system for DM. The system determines whether or not diabetes is present by determining the cardiac health of a patient using heart rate variability (HRV) analysis. This analysis was based on nine nonlinear features namely: Approximate Entropy (ApEn), largest Lyapunov exponet (LLE), detrended fluctuation analysis (DFA) and recurrence quantification analysis (RQA). Clinically significant measures were used as input to classification algorithms, namely AdaBoost, decision tree (DT), fuzzy Sugeno classifier (FSC), k-nearest neighbor algorithm (k-NN), probabilistic neural network (PNN) and support vector machine (SVM). Ten-fold stratified cross-validation was used to select the best classifier. AdaBoost, with least squares (LS) as weak learner, performed better than the other classifiers, yielding an average accuracy of 90%, sensitivity of 92.5% and specificity of 88.7%.
    Matched MeSH terms: Electrocardiography/methods
  15. Borhanuddin BK, Abdul Latiff H, Mohamed Yusof AK
    Cardiol Young, 2022 Dec;32(12):1994-1998.
    PMID: 35707919 DOI: 10.1017/S1047951122000154
    BACKGROUND: CT is an accepted non-invasive imaging tool to assess the coronary arteries in adults; however, its utilisation in children is limited by high heart rate and lack of standardised protocol. We sought to assess diagnostic quality and factors that affect image quality of CT in assessing coronary artery lesions in Kawasaki patients less than 18 years of age.

    METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.

    RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).

    CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.

    Matched MeSH terms: Electrocardiography/methods
  16. Ashkir Z, Samat AHA, Ariga R, Finnigan LEM, Jermy S, Akhtar MA, et al.
    Eur Heart J Cardiovasc Imaging, 2025 Jan 31;26(2):218-228.
    PMID: 39417278 DOI: 10.1093/ehjci/jeae260
    AIMS: Myocardial disarray, an early feature of hypertrophic cardiomyopathy (HCM) and a substrate for ventricular arrhythmia, is poorly characterized in pre-hypertrophic sarcomeric variant carriers (SARC+LVH-). Using diffusion tensor cardiac magnetic resonance (DT-CMR) we assessed myocardial disarray and fibrosis in both SARC+LVH- and HCM patients and evaluated the relationship between microstructural alterations and electrocardiographic (ECG) parameters associated with arrhythmic risk.

    METHODS AND RESULTS: Sixty-two individuals (24 SARC+LVH-, 24 HCM, and 14 matched controls) were evaluated with multi-parametric CMR including stimulated echo acquisition mode DT-CMR, and blinded quantitative 12-lead ECG analysis. Mean diastolic fractional anisotropy (FA) was reduced in HCM compared with SARC+LVH- and controls (0.49 ± 0.05 vs. 0.52 ± 0.04 vs. 0.53 ± 0.04, P = 0.009), even after adjustment for differences in extracellular volume (ECV) (P = 0.038). Both HCM and SARC+LVH- had segments with significantly reduced diastolic FA relative to controls (54 vs. 25 vs. 0%, P = 0.002). Multiple repolarization parameters were prolonged in HCM and SARC+LVH-, with corrected JT interval (JTc) being most significant (354 ± 42 vs. 356 ± 26 vs. 314 ± 26 ms, P = 0.002). Among SARC+LVH-, JTc duration correlated negatively with mean diastolic FA (r = -0.6, P = 0.002). In HCM, the JTc interval showed a stronger association with ECV (r = 0.6 P = 0.019) than with mean diastolic FA (r = -0.1 P = 0.72). JTc discriminated SARC+LVH- from controls [area under the receiver operator curve 0.88, confidence interval 0.76-1.00, P < 0.001], and in HCM correlated with the European Society of Cardiology HCM sudden cardiac death risk score (r = 0.5, P = 0.014).

    CONCLUSION: Low diastolic FA, suggestive of myocardial disarray, is present in both SARC+LVH- and HCM. Low FA and raised ECV were associated with repolarization prolongation. Myocardial disarray assessment using DT-CMR and repolarization parameters such as the JTc interval demonstrate significant potential as markers of disease activity in HCM.

    Matched MeSH terms: Electrocardiography*
  17. Sharma M, Agarwal S, Acharya UR
    Comput Biol Med, 2018 09 01;100:100-113.
    PMID: 29990643 DOI: 10.1016/j.compbiomed.2018.06.011
    Obstructive sleep apnea (OSA) is a sleep disorder caused due to interruption of breathing resulting in insufficient oxygen to the human body and brain. If the OSA is detected and treated at an early stage the possibility of severe health impairment can be mitigated. Therefore, an accurate automated OSA detection system is indispensable. Generally, OSA based computer-aided diagnosis (CAD) system employs multi-channel, multi-signal physiological signals. However, there is a great need for single-channel bio-signal based low-power, a portable OSA-CAD system which can be used at home. In this study, we propose single-channel electrocardiogram (ECG) based OSA-CAD system using a new class of optimal biorthogonal antisymmetric wavelet filter bank (BAWFB). In this class of filter bank, all filters are of even length. The filter bank design problem is transformed into a constrained optimization problem wherein the objective is to minimize either frequency-spread for the given time-spread or time-spread for the given frequency-spread. The optimization problem is formulated as a semi-definite programming (SDP) problem. In the SDP problem, the objective function (time-spread or frequency-spread), constraints of perfect reconstruction (PR) and zero moment (ZM) are incorporated in their time domain matrix formulations. The global solution for SDP is obtained using interior point algorithm. The newly designed BAWFB is used for the classification of OSA using ECG signals taken from the physionet's Apnea-ECG database. The ECG segments of 1 min duration are decomposed into six wavelet subbands (WSBs) by employing the proposed BAWFB. Then, the fuzzy entropy (FE) and log-energy (LE) features are computed from all six WSBs. The FE and LE features are classified into normal and OSA groups using least squares support vector machine (LS-SVM) with 35-fold cross-validation strategy. The proposed OSA detection model achieved the average classification accuracy, sensitivity, specificity and F-score of 90.11%, 90.87% 88.88% and 0.92, respectively. The performance of the model is found to be better than the existing works in detecting OSA using the same database. Thus, the proposed automated OSA detection system is accurate, cost-effective and ready to be tested with a huge database.
    Matched MeSH terms: Electrocardiography
  18. Agarwal A, Vyas S, Kumar R
    Malays Fam Physician, 2015;10(3):35-7.
    PMID: 27570607
    Wellen's syndrome is a pre-infarction stage of coronary artery disease characterised by predefined clinical and electrocardiographic (ECG) criteria of a subgroup of patients with myocardial ischaemia. Early recognition and appropriate intervention of this syndrome carry significant diagnostic and prognostic value. We report this unusual syndrome in an elderly man who presented with recurrent angina and characteristic ECG changes as T-waves inversion in the precordial leads, especially in V2-V6 during pain-free periods and ECG obtained during episodes of pain demonstrating upright T-waves with possible elevated ST segments from V1-V4. Cardiac enzymes were positive and coronary angiography revealed critical stenosis in the proximal left anterior descending artery. It is important to timely identify this condition and intervene appropriately as these patients may develop extensive myocardial infarction that carries a significant morbidity and mortality.
    Matched MeSH terms: Electrocardiography