METHODS: The Web of Science, SCOPUS, and PUBMED databases were searched to find eligible studies. The standardized mean difference (SMD) and 95% confidence interval (CI) were used to evaluate the differences in NLR, MLR, and PLR levels between SAP and non-SAP patients. The meta-analysis was conducted using the software "Review Manager" (RevMan, version 5.4.1, September 2020). The random-effect model was used for the pooling analysis if there was substantial heterogeneity. Otherwise, the fixed-effect model was adopted.
RESULTS: Twelve studies comprising 6302 stroke patients were included. The pooled analyses revealed that patients with SAP had significantly higher levels of NLR, MLR, and PLR than the non-SAP group. The SMD, 95% CI, p-value, and I2 for them were respectively reported as (0.88, 0.70-1.07, .00001, 77%); (0.94, 0.43-1.46, .0003, 93%); and (0.61, 0.47-0.75, .001, 0%). Subgroup analysis of NLR studies showed no significant differences in the effect size index between the severity of the stroke, the sample size, and the period between the stroke onset and the blood sampling.
CONCLUSION: This systematic review and meta-analysis suggest that an elevated NLR, MLR, and PLR were associated with SAP, indicating that they could be promising blood-based biomarkers for predicting SAP. Large-scale prospective studies from various ethnicities are recommended to validate this association before they can be applied in clinical practice.
METHODOLOGY: A prospective single-center cohort study was conducted in a tertiary care set-up. Transfusion Dependent Thalassemia patients registered with the pediatric unit were screened for hypercoagulability using TEG during six months of the study period and followed up for three years for the development of thromboembolic events. Patient demographics, history of splenectomy, Serum ferritin levels and annual red cell transfusion requirement (mL/kg/year) were assessed. TEG parameters used were R time, K time, alpha angle, Maximum amplitude, Clot index, and Lysis 30. The thrombin generation test (V Curve) obtained from the first-degree derivate of the TEG velocity curve was also used for analysis.
RESULTS: A total of 34 patients were recruited during the six months study period with an average age of 10.6 years ( ± 5.47). The average pre-transfusion hemoglobin level and the volume of packed red cells received were 7.24 g/dL and 152.82 mL/kg/year respectively. The TEG tracing was suggestive of a hypercoagulable state in 58.82% of patients. The mean values of angle (70.74), MA (64.16), CI (2.65) and TG (774.43) in TDT patients compared to age matched reference range (62.81, 57.99, 0.8, 577.83 respectively) was suggestive of prothrombotic changes. Annual blood transfusion requirement was negatively correlated with hypercoagulable status (-0.344, CI= -0.68 to 0.08). One out of 34 patients developed corona radiata infarct (with annual blood requirement; 112.7 mL/kg/Year). The risk to develop a hypercoagulable state appeared to be higher when the volume of RBCs transfused was less than 154 mL/kg/Year.
CONCLUSION: TDT patients are at risk of developing thromboembolism, and screening with TEG may be useful to identify those at high risk.
METHODS: A comprehensive review of recent literature on non-acid reflux and airway reflux in children was conducted. Studies ranged from January 2010 till November 2021 were searched over a period of a month: December 2021.
RESULTS: A total of eleven studies were identified. All studies included in this review revealed a strong link between non-acid reflux and airway reflux in children. 6 of the included studies are prospective studies, 3 retrospective studies, 1 cross-section study, and type of study was not mentioned in 1 study. The most common reported respiratory manifestation of non-acid reflux in children was chronic cough (7 studies). Predominant non-acid reflux was noted in 4 studies. The total number of children in each study ranges from 21 to 150 patients. MII-pH study was carried out in all studies included as a diagnostic tool for reflux investigation.
CONCLUSION: Non-acid reflux is the culprit behind airway reflux as well as other myriads of extra-esophageal manifestations in children. Multicentre international studies with a standardized protocol could improve scientific knowledge in managing non-acid reflux in airway reflux amongst children.
MATERIALS AND METHODS: A dose-ranging analysis using SKF7® was conducted through a randomized, double-blind, multicentre, placebo-controlled, phase 2 clinical trial involving individuals with obesity (N = 133) between January 2020 and April 2021. The potential percentage of change was assessed in relation to BW, BMI, WC and WHtR.
RESULTS: Average treatment effect estimates (treatment group vs. placebo) show a statistically significant reduction in the percentage of change for BW (mean = -2.915; CI: -4.546, -1.285), BMI (-2.921; CI: -4.551, -1.291), WC (mean = -2.187; CI: -3.784, -0.589) and WHtR (mean = -2.294, CI: -3.908, -0.681) in the group with a total of 750 mg of SKF7® (p
OBJECTIVE: The aim of this study is to test the accuracy of the AW frame by a direct head to head comparison with CRW® frame (Integra Life Sciences, Plainsboro, NJ) on a phantom.
METHODS: This is a prospective pilot cross-sectional phantom study with a total of 42 (21 for AW and 21 for CRW®) laboratory testings performed in 2017 at our institute to compare the accuracies of both frames in a consecutive manner. A phantom (BL phantom) was newly created, where targets can be placed at different heights and positions on a platform attached under the frame for accuracy testing comparing between the AW and CRW® frames.
RESULTS: A comparable accuracy testing results were observed between the AW and CRW® frames of 0.64 mm versus 1.07 mm respectively. Approval from the local ethics committee for a clinical trial was obtained. We report on three case illustrations who had the AW frame-based biopsies with definitive diagnoses and without any post-biopsy related complication.
CONCLUSION: AW frame successfully demonstrated a good accuracy of 0.64 mm in phantom testing using the BL phantom by a linear algorithmic calculation. The clinical trial with three patients demonstrated definitive diagnoses and safety with its use.
METHODS: We conducted a cross-sectional analysis of data from adults with T2D from 11 Asian countries/regions with structured assessment enrolled in the prospective Joint Asia Diabetes Evaluation (JADE) register between November 2007 and December 2019. Patients receiving insulin and/or injectable glucagon-like peptide-1 receptor agonists were excluded.
RESULTS: Amongst 62 512 patients (mean ± standard deviation age: 57.3 ± 11.8 years; 53.6% men), 54 783 (87.6%) were treated with OGLDs at enrolment. Most received one (37.5%) or two (44.2%) OGLDs. In the entire cohort, 59.4% of treated patients received SU-based therapy with variations amongst countries/regions. Overall, 79.5% of SU regimens were based on SUs plus metformin, and 22.1% on SUs plus dipeptidyl peptidase-4 inhibitors. Among SU users, gliclazide was most commonly prescribed (46.7%), followed by glimepiride (40.0%) and glibenclamide (8.1%). More gliclazide users entered the cohort with glycated haemoglobin levels <53 mmol/mol (7%) than non-gliclazide SU users (odds ratio [OR] 1.09, 95% CI 1.02-1.17), with less frequent self-reported hypoglycaemia in the 3 months before registration (OR 0.81, 95% CI 0.72-0.92; adjusted for sociodemographic factors, cardiometabolic risk factors, complications, use of other OGLDs, country/region and year of registration).
CONCLUSION: In Asia, SUs are a popular OGLD class, often combined with metformin. Good glycaemic control and safety profiles associated with the use of SUs, including gliclazide, support their position as a key treatment option in patients with T2D.
METHODS: We conducted a prospective cohort study, between March 27, 2004 and November 2, 2022, in 279 ICUs of 95 hospitals in 44 cities in 9 Asian countries (China, India, Malaysia, Mongolia, Nepal, Pakistan, Philippines, Sri Lanka, Thailand, Vietnam).
RESULTS: 153,717 patients, followed during 892,996 patient-days, acquired 3,369 VAPs. We analyzed 10 independent variables. Using multiple logistic regression we identified following independent VAP RFs= Age, rising VAP risk 1% per year (aOR=1.01; 95%CI=1.00-1.01, P
METHODS: This prospective cohort study enrolled consecutive samples of HCC patients and healthy controls. Venous blood samples were obtained at baseline and after interventions to determine serum levels of PIVKA-II and AFP using the chemiluminescent microparticle immunoassay method. Radiologic responses were determined based on the WHO criteria.
RESULTS: Fifty-four HCC patients (mean age 58.9 years, 49 males) and 40 healthy controls (mean age 33.5 years, 26 males) were recruited. The median serum levels of PIVKA-II and AFP in HCC vs. healthy controls were 988.4 vs. 24.2 mAU/ml and 13.6 vs. 1.7 ng/ml, respectively (both p
MATERIALS AND METHODS: A randomised prospective crossover study was designed to compare the AR Gynae endotrainer versus Karl Storz SZABO-BERCI-SACKIER laparoscopic trainer as a tool for training gynaecology laparoscopic skills. Participants were assigned to perform two specially designed tasks used for laparoscopic training using both endotrainers. All subjects evaluated both simulators concerning their performance by the use of a questionnaire comparing: design, ports placement, visibility, ergonomics, triangulation of movement, fulcrum effect, depth perception, ambidexterity, resources for training, and resources for teaching. The overall score was defined as the median value obtained. The ability and time taken for participants to complete the tasks using both endotrainers were also compared. A total of 26 participants were enrolled in this study, including 13 Masters's students from the Department of Obstetrics & Gynaecology and 13 Masters's students from the Department of Surgery, Hospital Universiti Sains Malaysia (HUSM), Kelantan, Malaysia.
RESULTS: A better performance was observed with AR Gynae as compared to Karl Storz endotrainer in five out of ten items evaluated in the questionnaire. Additionally, the overall score of AR Gynae endotrainer (median of 3.98) was comparable to that of Karl Storz endotrainer (median of 3.91) with p=0.519. For the items design and resources for teaching, the evaluation for AR Gynae endotrainer was significantly higher with p-values of 0.003 and 0.032, respectively. All participants were able to complete both tasks using both endotrainers. The time taken to complete both tasks was comparable on both endotrainers. Also, the AR Gynae endotrainer was cheaper.
CONCLUSIONS: The AR Gynae endotrainer was found to be a convenient and cost-effective laparoscopic simulator for gynaecology laparoscopic training and was comparable to the established Karl Storz SZABO-BERCI-SACKIER laparoscopic trainer.
METHOD: Prospective cohort study on CWE age 7-18 years old with no comorbidities. Epilepsy education was delivered using Epigame. CWE completed AKA questionnaire before (time point 1 [TP1]), immediately after (TP2), 3 months (TP3) after provision of Epigame. Child self-report Health-Related Quality of Life Measurement for Children with Epilepsy (CHEQOL-25) questionnaire was completed at TP1 and TP3.
RESULTS: Total of 106 CWE participated in this study (mean age of 13.3 years). Baseline (TP1) AKA was rated "very low to moderate" for awareness domain in 95.3 %, "very low to moderate" for knowledge domain in 67 %, "negative to indifferent" for attitude domain in 54.7 %, and "very poor to moderate' for total AKA score domain in 84 %. "Positive to very positive" for child attitude domain was significantly associated with parents with "positive to very positive" for attitude domain (OR 10.6, 95 % CI 3.23-34.66). "Good to excellent" for total child AKA domain was significantly associated with parents with "Good to excellent" for total AKA domain (OR 5.2, 95 % CI 1.16-15.02) and with