METHODS: Relations between skeletal movement, hyoid bone position and three-dimensional pharyngeal airway changes were retrospectively analyzed on pre- and post-surgical CBCTs in dento-skeletal class II patients who underwent orthognathic two-jaw surgery with segmentation.
RESULTS: While long-term significant reductions in length (P= 0.003), surface area (P= 0.042) and volume (P= 0.004) were found in the nasopharynx, the highly significant increases in oropharyngeal airway length, surface area, volume and the minimal cross-sectional area (P
METHOD: A convenience sample of 102 patients was recruited from four Cure and Care Service Centres in Malaysia.
RESULTS: Principal component analysis with varimax rotation supported two-factor solutions for each subscale: problem recognition, desire for help and treatment readiness, which accounted for 63.5%, 62.7% and 49.1% of the variances, respectively. The Cronbach's alpha coefficients were acceptable for the overall measures (24 items: ∝ = 0.89), the problem recognition scale (10 items; ∝ = 0.89), desire for help (6 items; ∝ = 0.64) and treatment readiness scale (8 items; ∝ = 0.60). The results also indicated significant motivational differences for different modalities, with inpatients having significantly higher motivational scores in each scale compared to outpatients.
CONCLUSION: The present study pointed towards the favourable psychometric properties of a motivation for treatment scale, which can be a useful instrument for clinical applications of drug use changes and treatment.
METHODS: Dose measurement of a standard pear-shaped plan carried out in phantom to verify the MOSkin dose measurement accuracy. With MOSkin attached to the third diode, RP3 of the PTW 9112, both detectors were inserted into patients' rectum. The RP3 and MOSkin measured doses in 18 sessions as well as the maximum measured doses from PTW 9112, RPmax in 48 sessions were compared to the planned doses.
RESULTS: Percentage dose differences ΔD (%) in phantom study for two MOSkin found to be 2.22 ± 0.07% and 2.5 ± 0.07%. IVD of 18 sessions resulted in ΔD(%) of -16.3% to 14.9% with MOSkin and ΔD(%) of -35.7% to -2.1% with RP3. In 48 sessions, RPmax recorded ΔD(%) of -37.1% to 11.0%. MOSkin_measured doses were higher in 44.4% (8/18) sessions, while RP3_measured were lower than planned doses in all sessions. RPmax_measured were lower in 87.5% of applications (42/47).
CONCLUSIONS: The delivered doses proven to deviate from planned doses due to unavoidable shift between imaging and treatment as measured with MOSkin and PTW 9112 detectors. The integration of MOSkin on commercial PTW 9112 surface found to be feasible for rectal dose IVD during cervical HDR ICBT.