Displaying publications 141 - 160 of 554 in total

Abstract:
Sort:
  1. Tan PC, Khine PP, Sabdin NH, Vallikkannu N, Sulaiman S
    J Ultrasound Med, 2011 Feb;30(2):227-33.
    PMID: 21266561
    OBJECTIVES: The purpose of this study was to evaluate cervical length changes after membrane sweeping and the effect of cervical shortening on pregnancy outcomes.

    METHODS: Low-risk women at 40 weeks' gestation undergoing membrane sweeping to expedite labor were recruited. Participants were scheduled for labor induction at 41 weeks' gestation. Transvaginal ultrasonography was performed immediately before and after membrane sweeping to measure the cervical length. Three presweep and postsweep cervical lengths were measured. The shortest lengths before and after the sweep were taken as the representative lengths. The effect of membrane sweeping on cervical length was analyzed. Multivariable logistic regression analysis was performed to evaluate the effect of cervical shortening on labor induction and the mode of delivery.

    RESULTS: For the 160 participants, the mean presweep cervical length ± SD was 21.0 ± 10.0 mm; the postsweep length was 23.8 ± 10.9 mm, an average increase of 2.8 ± 0.6 mm (P < .001). Cervical shortening after membrane sweeping was noted in 53 of 160 cases (33%). Cervical shortening was associated with a reduction in all-cause cesarean delivery but not labor induction on bivariate analysis. After adjustment for maternal age, parity, presweep Bishop score, postsweep cervical length, oxytocin augmentation, epidural analgesia, and meconium-stained fluid, cervical shortening after membrane sweeping was independently predictive of a reduction in cesarean deliveries (adjusted odds ratio, 0.24; 95% confidence interval, 0.06-0.90; P = .034).

    CONCLUSIONS: Membrane sweeping was associated with lengthening of the cervix. A shortened cervix after sweeping was independently predictive of vaginal delivery.

    Matched MeSH terms: Ultrasonography
  2. Wijesuriya LI
    Malays Fam Physician, 2007;2(3):106-9.
    PMID: 25606095 MyJurnal
    Acute appendicitis has been known as a disease entity for well over a century but a confident diagnosis before surgery in all patients suspected of the condition is still not possible. Timely diagnosis is essential to minimise morbidity due to possible perforation of the inflamed organ in the event treatment is delayed; so much so that surgeons often preferred to operate at the slightest suspicion of the diagnosis in the past. This resulted in the removal of many normal appendixes. When the diagnosis of appendicitis is clear from the history and clinical examination, then no further investigation is necessary and prompt surgical treatment is appropriate. Where there is doubt about the diagnosis however it is advisable to resort to imaging studies such as abdominal ultrasound or computed tomography to clear such suspicions before subjecting the patient to an appendicectomy. These studies would also help avoid delays in surgery in deserving patients.
    Matched MeSH terms: Ultrasonography
  3. Tan PC, Suguna S, Vallikkannu N, Hassan J
    Aust N Z J Obstet Gynaecol, 2006 Dec;46(6):505-9.
    PMID: 17116055
    To assess the relationship of ultrasound assessment for amniotic fluid, fetal weight, cervical length, cervical funneling and clinical factors on the risk of Caesarean delivery after labour induction at term.
    Matched MeSH terms: Amniotic Fluid/ultrasonography; Ultrasonography, Prenatal*
  4. Bustam A, Noor Azhar M, Singh Veriah R, Arumugam K, Loch A
    Emerg Med J, 2014 May;31(5):369-73.
    PMID: 23428721 DOI: 10.1136/emermed-2012-201789
    OBJECTIVES: The aim of this study was to evaluate if emergency medicine trainees with a short duration of training in echocardiography could perform and interpret bedside-focused echocardiography reliably on emergency department patients.
    METHODS: Following a web-based learning module and 3 h of proctored practical training, emergency medicine trainees were evaluated in technical and interpretative skills in estimating left ventricular function, detection of pericardial effusion and inferior vena cava (IVC) diameter measurements using bedside-focused echocardiography on emergency department patients. An inter-rater agreement analysis was performed between the trainees and a board-certified cardiologist.
    RESULTS: 100 focused echocardiography examinations were performed by nine emergency medicine trainees. Agreement between the trainees and the cardiologist was 93% (K=0.79, 95% CI 0.773 to 0.842) for visual estimation of left ventricular function, 92.9% (K=0.80, 95% CI 0.636 to 0.882) for quantitative left ventricular ejection fraction by M-mode measurements, 98% (K=0.74, 95% CI 0.396 to 1.000) for the detection of pericardial effusion, and 64.2% (K=0.45, 95% CI 0.383 to 0.467) for IVC diameter assessment. The Bland-Altman limits of agreement for left ventricular function was -9.5% to 13.7%, and a Pearson's correlation yielded a value of 0.82 (p<0.0001, 95% CI 0.734 to 0.881). The trainees detected pericardial effusion with a sensitivity of 60%, specificity of 100%, positive predictive value of 100% and negative predictive value of 97.9%.
    CONCLUSIONS: Emergency medicine trainees were found to be able to perform and interpret focused echocardiography reliably after a short duration of training.
    Study site: Trauma and emergency department, University of Malaya Medical Centre, Kuala Lumpur
    Matched MeSH terms: Pericardial Effusion/ultrasonography; Vena Cava, Inferior/ultrasonography; Ventricular Dysfunction, Left/ultrasonography
  5. Nik Muhamad NA, Safferi RS, Robertson CE
    Med J Malaysia, 2015 Apr;70(2):63-6.
    PMID: 26162379 MyJurnal
    OBJECTIVE: To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter.
    METHODS: A prospective, cross-sectional, convenience sampling observational study.
    RESULTS: 25 patients from the Emergency Department (ED) Universiti Kebangsaan Malaysia Medical Centre (UKMMC) were studied between 1st March and 30th April 2013. The median age was 63 years (95% CI 54-67). There was a significant correlation between IJV height and CVP using central venous access (r=0.64 p<0.001). Correlation between IVC diameter in end expiration and CVP was 0.74 (p<0.001). An IJV height measurement >8cm predicted a CVP >8cm H2O (sensitivity 71.4%, specificity of 83.3%).
    CONCLUSION: Measurement of IJV height and IVC diameter by ultrasonography correlates well with invasive CVP and is useful for the assessment of volume status in critically ill patients in the ED.
    Study site: Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur
    Matched MeSH terms: Ultrasonography
  6. Teoh LO, Ishikawa H, Liebmann JM, Ritch R
    Arch. Ophthalmol., 2000 Jul;118(7):989-90.
    PMID: 10900117
    Matched MeSH terms: Iris/ultrasonography; Pigment Epithelium of Eye/ultrasonography; Glaucoma, Angle-Closure/ultrasonography
  7. Abdullah BJJ, Paramsothy M, Khir ASM, Chan SP
    Med J Malaysia, 2000 Jun;55(2):169-73.
    PMID: 19839144
    Our preliminary experience of Somatostatin Receptor Positive Tumour Scintigraphy (SRPTS) in the management of some rare neuroendocrine tumours is highlighted. Six patients were evaluated using SRPTS. A single patient each with Zollinger-Ellison syndrome, recurrent medullary carcinoma of thyroid and Stage IV neuroblastoma. Two patients with phaeochromocytoma, and one patient with suspected insulinoma were evaluated. SRPTS was useful in three of the six patients studied i.e. patient with gastrinoma, recurrent medullary carcinoma of thyroid and metastatic neuroblastoma. SRPTS although expensive is a useful and cost-effective approach of rare endocrine tumours and it role as a first line tool in the diagnosis is discussed.
    Matched MeSH terms: Neuroblastoma/ultrasonography; Zollinger-Ellison Syndrome/ultrasonography; Carcinoma, Medullary/ultrasonography
  8. Ram SP, Malik AS
    Med J Malaysia, 1994 Mar;49(1):96-9.
    PMID: 8058000
    Three children with cardiac tumors are described: a 12-year-old female child who had left atrial myxoma, and two males having rhabdomyoma of the right ventricle associated with tuberous sclerosis. The child with left atrial myxoma was symptomatic and the tumour was subsequently excised. The other two children with rhabdomyoma were managed conservatively.
    Matched MeSH terms: Heart Neoplasms/ultrasonography*; Myxoma/ultrasonography*; Rhabdomyoma/ultrasonography*
  9. Dass RM, Kim E, Kim HK, Lee JY, Lee HJ, Rhee SJ
    Korean J Pain, 2019 Jul 01;32(3):223-227.
    PMID: 31257831 DOI: 10.3344/kjp.2019.32.3.223
    Radiofrequency neurolysis (RFN) of the genicular nerves has recently become accepted as an effective technique to alleviate knee pain particularly in patients with knee osteoarthritis (OA) or postoperative pain. However, genicular nerve RFN can produce high procedure and equipment costs, longer procedural times, procedure-related pain, and failure rate of over 25%. We are presenting two cases of alcohol neurolysis of the genicular nerve using fluoroscopy and ultrasonography in patients with knee OA or persistent postsurgical pain of the knee. Alcohol neurolysis of the genicular nerve with dual imaging modality can be a cheap, safe and effective method in patients with chronic knee pain.
    Matched MeSH terms: Ultrasonography
  10. Qurash MT, Yaacob NY, Azuan N, Khaleel YS, Zakaria R
    J Med Ultrasound, 2018 06 18;26(4):210-214.
    PMID: 30662153 DOI: 10.4103/JMU.JMU_40_18
    Interventional radiology procedures are becoming more challenging over time; thus, there is a need for excellent and reliable training methods. Training on live patients is neither safe nor an ethical solution. Alternatives are many and varied, but the most popular is ultrasound guided simulators. This report shows how a simple, homemade, low-cost phantom material, and construction modules can provide several advantages over ordinary gelatin phantoms. A new layering technique and target synthesis are described for the biopsy phantom, including tips on decreasing the needle pass artifact as well as controlling the mixture echogenicity.
    Matched MeSH terms: Ultrasonography
  11. Abdul Sattar Arif Khammas, Hasyma Abu Hassan
    MyJurnal
    The most common cause of the chronic liver disease is non-alcoholic fatty liver disease (NAFLD). This study was designed to compare a mean subcutaneous tissue thickness (SCTT) and hepatic echo-intensity attenuation rate (HEIAR) among NAFLD grades. Sonography was carried out on 628 consecutive subjects. The distance between the skin surface and the liver capsule was measured and was labelled the SCTT. Also, the ultrasound of HEIAR was retrospectively quantified on an image archiving. HEIAR was calculated as the difference between mean intensity of echo for two regions of interest (ROIs) in near- and far-fields divided by the distance between these two ROIs multiply by frequency of the probe. Of the 628, 235 subjects were diagnosed with NAFLD. The age range was 45 – 75 years with mean 54.5 ± 6.7 years. There was a significant difference of mean SCTT among NAFLD grades (p
    Matched MeSH terms: Ultrasonography
  12. Tey KJ, Goh BS, Mohd-Zaki F
    Iran J Otorhinolaryngol, 2020 Nov;32(113):391-395.
    PMID: 33282788 DOI: 10.22038/ijorl.2020.45727.2501
    Introduction: Ectopic thymus is an uncommon cause of neck masses in children that frequently present as lateral cervical swelling especially on the right side.

    Case Report: We report two cases with atypical clinical presentation of ectopic thymus and superior herniation of normal thymus. Both of the patients manifested as intermittent midline mass at the suprasternal region during Valsalva manuevre. Unique ultrasound features with the location along the thymic descent together with dynamic assessment of the organ movement were essential to reach the correct diagnosis. Conservative approach was considered in these patients considering the necessity of thymus in the process of puberty.

    Conclusion: High index of suspicion is of utmost importance when encounter patient with similar clinical manifestation to avoid unnecessary diagnostic modalities and surgeries. Accurate diagnosis will also alleviate parents' anxiety.

    Matched MeSH terms: Ultrasonography
  13. Ng SY, Kamada T, Suleiman M, Vairappan CS
    Nat Prod Commun, 2016 Aug;11(8):1071-1072.
    PMID: 30725558
    A new compound, schistochilic acid D (1) and two known compounds (2 and 3) were isolated from MeOH extract of Bornean liverwort. Schistochila acuininata collected from Mount Trus Madi, Sabah. The structure of the new metabolite was established based on spectroscopic (ID NMR, 2D NMR, and IR). and HRESIMS data. In addition, another population of S. acuminata collected from Mount Alab (Sabah) yielded four known compounds, 2, 3, 4 and 5. These compounds were tested for their biological potential against the B 16-Fl0 cell line. Compounds 4 and 5 exhibited weak cytotoxic activity.
    Matched MeSH terms: Ultrasonography
  14. Chandirasegaran S, Gunalan R, Aik S, Kaur S
    J Orthop Surg (Hong Kong), 2019 4 6;27(2):2309499019839126.
    PMID: 30947613 DOI: 10.1177/2309499019839126
    PURPOSE:: To compare the hindfoot correction using clinical and ultrasonography assessment in clubfoot patients undergoing Achilles tendon tenotomy with patients corrected with casting alone.

    METHOD:: A prospective observational study on idiopathic clubfoot patients less than 3 months old. Clinical assessment was done using hindfoot Pirani score and measurement of ankle dorsiflexion. Serial ultrasonography was done to measure the length and thickness of the Achilles tendon pre-hindfoot correction, 3 and 6 weeks post-hindfoot correction. Independent t-test was used to analyse the increase in ankle dorsiflexion, improvement in length and thickness of Achilles tendon between the two groups. Mann-Whitney U test was used to analyse the improvement in hindfoot Pirani score. Pearson correlation test was used for correlation in between clinical severity and ultrasonography assessment.

    RESULTS:: Twenty-three patients with bilateral clubfoot and four with unilateral clubfoot were recruited with a total of 50 clubfeet. Each group consists of 25 feet with a mean age of 2 months. Marked improvement in hindfoot correction was noted in tenotomy group compared to non-tenotomy group as evidenced by significant increase in Achilles tendon length, ankle dorsiflexion and improvement of hindfoot Pirani score. No significant difference in Achilles tendon thickness was noted between the two groups. Positive correlation was demonstrated between increase in Achilles tendon length and increase in ankle dorsiflexion as well as improvement in hindfoot Pirani score.

    CONCLUSION:: We would like to propose Achilles tendon tenotomy in all clubfoot patients as it is concretely evident that superior hindfoot correction was achieved in tenotomy group.

    Matched MeSH terms: Ultrasonography
  15. Aimanan K, Lim SY, Mohd Nor MR, Wahi AM, Chew LG
    Med J Malaysia, 2020 01;75(1):88-93.
    PMID: 32008030
    INTRODUCTION: Pseudo aneurysm of the ankle is a rare presentation and the management is complex due to the complex anatomy. The aim of this review is to examine the epidemiology, etiology, diagnostic modalities used and management. This is the first systematic review of this topic in literature.

    METHODS: We performed a systematic review in multiple databases (including PubMed, MEDLINE, EMBASE, and Scopus) from 1966 to May 18, 2019, to identify all case reports and case series describing patients with ankle pseudo aneurysm. This systematic review was performed in accordance with the Preferred Reporting Items for a Systematic Review and Meta-analysis (PRISMA). Our inclusion criteria included patients with ankle pseudo aneurysm of any age. We excluded reports in which the individual level data is not available. Patients demographic (gender, age), clinical characteristics (precipitating event, duration), diagnostic modality and treatment were recorded.

    RESULT: There were in total 23 case reports identified on ankle pseudo aneurysm from 1966 until 2018. Among these twenty-three reports, 16 (70%) were male and seven (30%) patients were female. Age distribution showed higher number of reports among young adults, 15 patients (65%). Based on our systematic review trauma (48%), arthroscope (48%) and arthrodesis (4%) were the etiologies described in all these case reports. Ultrasound duplex and CT Angiogram has been used as a single modality in three reports each. In fifteen patients (65%) combination of imaging has been used for diagnosis. Anterior tibial artery is the most commonly injured vessel among the reported cases, comprised of 14 (61%) patients. Among these arthroscopes were the highest reported precipitating events, 9 (64%), followed by trauma in four patients (29%) and arthrodesis in one patient (7%). Treatment modalities described in all previous reports were excision and ligation, 10 (42%); excision of sac and primary repair, 4 (17%); excision of sac followed by reversed saphenous venous graft repair, 2 (8%); US guided compression, 2 (8%); US guided thrombin injection, 4 (17%); stenting, 1 (4%) and coiling, 1 (4%).

    CONCLUSION: Ankle pseudoaneurysm is mostly preventable by detailed initial assessment following trauma or careful approach during arthroscope. Evolving diagnostic modality and treatment has shed some light into noninvasive management of pseudo aneurysm of ankle.

    Matched MeSH terms: Ultrasonography, Doppler, Duplex
  16. Kamisan Atan I, Zhang W, Shek KL, Dietz HP
    PMID: 33561585 DOI: 10.1016/j.ejogrb.2021.01.047
    OBJECTIVE: Vaginal childbirth is an established main aetiological factor in the pathogenesis of female pelvic floor dysfunction. However, pregnancy itself is also likely to have an effect. This study investigated the effect of pregnancy on pelvic floor functional anatomy.

    STUDY DESIGN: This was a retrospective observational study involving vaginally nulliparous women who presented to a tertiary urogynaecology unit with symptoms and signs of pelvic floor dysfunction between 2006 and 2014. Nulliparous women were compared with those who delivered exclusively by Caesarean Section (CS). All had undergone a standardised clinical interview, ICS POP-Q assessment and 3D/4D translabial pelvic floor ultrasound. Main outcome measures included sonographically determined pelvic organ position and hiatal dimensions on Valsalva and pelvic floor muscle contraction (PFMC).

    RESULTS: Of 2930 women seen during the study period, 242 had never given birth vaginally. One hundred and twenty-nine (53 %) were nulliparous, and 113 (47 %) were delivered by CS only. The CS group demonstrated significantly higher pelvic organ mobility in the anterior compartment (all P < 0.05) and a larger hiatal area on Valsalva (P = 0.004). All sonographic measures of pelvic floor muscle function demonstrated greater tissue displacement on PFMC in the CS group (all P < 0.05).

    CONCLUSIONS: Compared to nulliparas, women who delivered exclusively by CS showed increased pelvic organ descent on Valsalva and tissue displacement on PFMC, implying increased tissue elasticity/ compliance or reduced stiffness, consistent with a small permanent hormonal and/or mechanical effect of pregnancy.

    Matched MeSH terms: Ultrasonography
  17. Apriono C, Muin F, Juwono FH
    Sensors (Basel), 2021 Aug 28;21(17).
    PMID: 34502698 DOI: 10.3390/s21175807
    Recently, rapid advances in radio detection and ranging (radar) technology applications have been implemented in various fields. In particular, micro-Doppler radar has been widely developed to perform certain tasks, such as detection of buried victims in natural disaster, drone system detection, and classification of humans and animals. Further, micro-Doppler radar can also be implemented in medical applications for remote monitoring and examination. This paper proposes a human respiration rate detection system using micro-Doppler radar with quadrature architecture in the industrial, scientific, and medical (ISM) frequency of 5.8 GHz. We use a mathematical model of human breathing to further explore any insights into signal processes in the radar. The experimental system is designed using the USRP B200 mini-module as the main component of the radar and the Vivaldi antennas working at 5.8 GHz. The radar system is integrated directly with the GNU Radio Companion software as the processing part. Using a frequency of 5.8 GHz and USRP output power of 0.33 mW, our proposed method was able to detect the respiration rate at a distance of 2 m or less with acceptable error. In addition, the radar system could differentiate different frequency rates for different targets, demonstrating that it is highly sensitive. We also emphasize that the designed radar system can be used as a portable device which offers flexibility to be used anytime and anywhere.
    Matched MeSH terms: Ultrasonography, Doppler
  18. Kachewar S, Kulkarni D
    Biomed Imaging Interv J, 2011 Oct;7(4):e27.
    PMID: 22279504 DOI: 10.2349/biij.7.4.e27
    This short case report discusses the various aspects of penile fracture, which is a rare entity. Nevertheless, the incidence of penile fractures is on the rise due to the increased use of performance-enhancing drugs. An individual with a penile fracture should seek immediate medical referral. Prompt diagnosis and management is necessary to prevent undesirable after-effects as discussed. Emphasis is made on how imaging with ultrasound enables a quick and complete assessment of this mishap.
    Matched MeSH terms: Ultrasonography
  19. Kandiah R, Mohamad I
    Malays Fam Physician, 2019;14(3):77-79.
    PMID: 32175047
    Jugular phlebectasia has been increasingly recognised with the advent of non-invasive diagnostic methods. Phlebectasia differs from varix, as it is an abnormal outward dilatation of a vein without tortuosity. It presents as a soft, compressible mass, apparent upon straining or execution of the Valsalva maneuver. The differentials for neck masses are broad, but if the swelling appears on the Valsalva maneuver, the type of mass narrows down to a laryngocele, superior mediastinal mass or phlebectasia. A simple non-invasive investigation, such as ultrasonography, is used as a diagnostic tool. We report a case of jugular phlebectasia that was suspected clinically and confirmed via ultrasound to be a vascular lesion which changed its size upon straining.
    Matched MeSH terms: Ultrasonography
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links