Displaying publications 141 - 160 of 165 in total

Abstract:
Sort:
  1. Fuah KW, Lim CTS, Pang DCL, Wong JS
    Saudi J Kidney Dis Transpl, 2018 2 20;29(1):207-209.
    PMID: 29456232 DOI: 10.4103/1319-2442.225177
    Tranexamic acid (TXA) is an antifibrinolytic agent commonly used to achieve hemostasis. However, there have been a few case reports suggesting that high-dose intravenous TXA has epileptogenic property. In patients with renal impairment, even administering the usual recommended dose of TXA can induce seizure episodes. We present here a patient on hemodialysis who developed seizures after receiving two doses of TXA over 5 h period.
    Matched MeSH terms: Catheterization, Central Venous/adverse effects*
  2. Ng YY, Abdel-Latif Mel-A, Gan CS, Siham A, Zainol H, Lum LC
    Singapore Med J, 2015 Sep;56(9):506-12.
    PMID: 26451053 DOI: 10.11622/smedj.2015135
    The present study aimed to determine the impact of an extended infection control training programme, which was conducted for all interns posted to the Department of Paediatrics, on the incidence of paediatric intensive care unit (PICU)-acquired bloodstream infections (BSIs) in University Malaya Medical Centre, Malaysia.
    Matched MeSH terms: Catheterization, Central Venous/adverse effects
  3. Dipak S, Prepageran N, Rahmat O, Raman R
    Med J Malaysia, 2005 Oct;60(4):498-501.
    PMID: 16570716
    The use of airway stents for the treatment of benign airway stenosis is increasingly advocated. However, the long-term safety and efficiency of these devices has not been established. We present a case of tracheal stenosis. which persisted despite open surgical and laser correction. The patient required tracheal stent insertion and is currently well with no respiratory difficulty. The use of metallic or silicon intraluminal stent remains appropriate in cases in which there is defined and relative short-term end point of treatment.
    Matched MeSH terms: Catheterization
  4. Murugiah M, Sakijan AS
    Med J Malaysia, 1991 Sep;46(3):290-3.
    PMID: 1839928
    This is a case report of ascaris worm in the common bile duct in a 61 year old lady. Ultrasound diagnosis was initially made based on the presence of linear hyperreflective foci within the common bile duct. ERCP confirmed a single worm within the duct. Balloon extraction was then successfully carried out following papillotomy. This case illustrates the value of ultrasound in the definitive diagnosis of biliary ascariasis and the therapeutic role of ERCP.
    Matched MeSH terms: Catheterization
  5. Kannan P, Sivanesaratnam V, Jeyamalar R, Delilkan A, Ong G
    Aust N Z J Obstet Gynaecol, 1990 May;30(2):146-9.
    PMID: 2400358
    The gynaecologist today is likely to encounter elderly patients with severe coronary heart disease requiring major gynaecological surgery. The successful outcome in 2 such patients with compromised coronary circulation and impaired left ventricular function emphasized the importance of combined care with the cardiologist and the anaesthetist. The insertion of a Swan-Ganz catheter for close perioperative monitoring is vital. The intra-and postoperative problems are discussed.
    Matched MeSH terms: Catheterization, Swan-Ganz
  6. Kho SS, Tie ST, Chan SK, Yong MC, Chai SL, Voon PJ
    Respirol Case Rep, 2017 May;5(3):e00221.
    PMID: 28250931 DOI: 10.1002/rcr2.221
    Chylothorax is defined as the presence of chyle in the pleural cavity. Central vein thrombosis is an under-recognized cause of chylothorax in the adult population and is commonly related to central venous catheterization. Case 1 illustrates a patient with AIDS and disseminated tuberculosis with left chylothorax and central vein thrombosis after a month of antituberculosis therapy. Case 2 was a patient with advanced seminoma who presented with left chylothorax and central vein thrombosis while on chemotherapy. Chylothorax resolved with anticoagulation for both cases. Case 3 was a lymphoma patient with central vein thrombosis who developed chylothorax during chemotherapy. Chylothorax resolved with the continuation of anticoagulation and did not recur despite his progressive underlying lymphoma. There was no central venous catheterization in any of these three cases. These cases illustrate the unique association of central vein thrombosis and chylothorax and the importance of anticoagulation in its management.
    Matched MeSH terms: Catheterization, Central Venous
  7. Adi O, Fong CP, Azil A, Wahab SFA
    Ultrasound J, 2019 Feb 25;11(1):1.
    PMID: 31359296 DOI: 10.1186/s13089-019-0116-9
    BACKGROUND: We report a case study of fat embolism seen on ultrasound at right internal jugular vein during central venous cannulation in a patient diagnosed with fat embolism syndrome. This case demonstrates the importance of ultrasound for evaluation of trauma cases with suspicion of fat embolism.

    CASE PRESENTATION: A 23-year-old trauma patient with closed fracture of left femoral shaft and left humerus presented to our emergency department (ED). 11 h after admission to ED, patient became confused, hypoxic and hypotensive. He was then intubated for respiratory failure and mechanically ventilated. Transesophageal ultrasound revealed hyperdynamic heart, dilated right ventricle with no regional wall abnormalities and no major aorta injuries. Whole-body computed tomography was normal. During central venous cannulation of right internal jugular vein (IJV), we found free floating mobile hyperechoic spots, located at the anterior part of the vein. A diagnosis of fat embolism syndrome later was made based on the clinical presentation of long bone fractures and fat globulin in the blood. Despite aggressive fluid resuscitation, patient was a non-responder and needed vasopressor infusion for persistent shock. Blood aspirated during cannulation from the IJV revealed a fat globule. Patient underwent uneventful orthopedic procedures and was discharged well on day 5 of admission.

    CONCLUSIONS: Point-of-care ultrasound findings of fat embolism in central vein can facilitate and increase the suspicion of fat embolism syndrome.

    Matched MeSH terms: Catheterization, Central Venous
  8. Amrizal, M.N., Rohaizat, Y.B., Saperi, S., SyedMohamed Aljunid
    MyJurnal
    Hospital UKM is the first hospital to implement case·mix system in Malaysia. The objective of the programme is to utilise case-mix system as a tool in improving efficiency and quality of care. From July 2002 to June 2004, a total of 35,568 cases were grouped using IRDRG-Version 1.1 case-mix grouper. Out of these, 3,622 cases or 10.2 % were cardiology cases in MDC 05 (Diseases and Disorders of the Circulatory System). Medical Cardiology cases consist of 86.5% and the remaining 13.5% were Surgical Cardiology. Most of the cases were in severity level one (43.4%), 29.5 % in severity level two and 27.1% in severity level three. The mortality rates for severity level one, two and three were 1.0%, 2.6% and 11.5% respectively. Top three cardiology cases were Acute Myocardial Infarction Without Comorbidity and Complication (IRDRG 05331) (8.4%), Acute Myocardial Infarction With Major Comorbidity and Complication (IRDRG 05333) (7.6%) and Cardiac Catheterization for Ischemic Heart Disease Without Comorbidity and Complication (IRDRG 05311) (7.4%). Step-down costing was carried out to obtain the cost for each DRG group. The mean cost per episode of care for Medical Cardiology cases was RM 3,562 (SD= RM 2, 1 19) with average LOS of 6.4 days (SD= 3 .8days) . For the Surgical Cardiology cases, the mean cost per episode ofcare was RM 6,526 (SD= RM 4,585) and average LOS of5.8 days (SD= 4.1 days). The main components of cost for Medical Cardiology cases are ICU cost (28.8%), pharmacy (17.3%) and Ward Services (15.3%). In Surgical Cardiology, the biggest component of cost was for Operation Theatre (27.9%), followed by Ward Services (25 .4%) and pharmacy (8.5%). Multivariate analysis using multiple linear regression showed that factors which significantly influence the treatment cost of cardiology cases were length of stay, age of the patient, discharge outcome, case type ('surgical partition') and severity level.
    Matched MeSH terms: Cardiac Catheterization
  9. Asahar SF, Malek KA, Zohdi WNWM, Peter AB
    Korean J Fam Med, 2020 Jan;41(1):68-72.
    PMID: 31902199 DOI: 10.4082/kjfm.18.0157
    We present the case of a 14-year-old Malay girl with an ependymoma of the conus medullaris who presented to multiple general practitioner clinics with a 24-month history of chronic low back pain. The pain was symptomatically managed as a simple musculoskeletal pain and sciatica. Further imaging to aid diagnosis was delayed until the appearance of severe pain with neurological deficits. Magnetic resonance imaging revealed an enhancing spinal mass at L1 through L3, and histopathological investigations confirmed the grade II ependymoma according to the World Health Organization classification. She underwent gross resection of the tumor. After the surgery, she developed neurogenic urinary bladder and bowel, which required intermittent self-catheterization, intermittent enema use, and intensive physical therapy.
    Matched MeSH terms: Catheterization
  10. Bassan MS, Sundaralingam P, Fanning SB, Lau J, Menon J, Ong E, et al.
    Gastrointest Endosc, 2018 Jun;87(6):1454-1460.
    PMID: 29317269 DOI: 10.1016/j.gie.2017.11.037
    BACKGROUND AND AIMS: Wire-guided biliary cannulation has been demonstrated to improve cannulation rates and reduce post-ERCP pancreatitis (PEP), but the impact of wire caliber has not been studied. This study compares successful cannulation rates and ERCP adverse events by using a 0.025-inch and 0.035-inch guidewire.

    METHODS: A randomized, single blinded, prospective, multicenter trial at 9 high-volume tertiary-care referral centers in the Asia-Pacific region was performed. Patients with an intact papilla and conventional anatomy who did not have malignancy in the head of the pancreas or ampulla and were undergoing ERCP were recruited. ERCP was performed by using a standardized cannulation algorithm, and patients were randomized to either a 0.025-inch or 0.035-inch guidewire. The primary outcomes of the study were successful wire-guided cannulation and the incidence of PEP. Overall successful cannulation and ERCP adverse events also were studied.

    RESULTS: A total of 710 patients were enrolled in the study. The primary wire-guided biliary cannulation rate was similar in 0.025-inch and 0.035-inch wire groups (80.7% vs 80.3%; P = .90). The rate of PEP between the 0.025-inch and the 0.035-inch wire groups did not differ significantly (7.8% vs 9.3%; P = .51). No differences were noted in secondary outcomes.

    CONCLUSION: Similar rates of successful cannulation and PEP were demonstrated in the use of 0.025-inch and 0.035-inch guidewires. (Clinical trial registration number: NCT01408264.).

    Matched MeSH terms: Catheterization
  11. Rehman R, Marhisham MC, Alwi M
    Future Cardiol, 2018 01;14(1):55-73.
    PMID: 29199861 DOI: 10.2217/fca-2017-0053
    Patent ductus arteriosus (PDA) stenting has gained acceptance for palliation in cyanotic congenital heart disease. The PDA in tetralogy of Fallot with pulmonary atresia (ToF-PA) arises, in the left aortic arch, from underneath the arch and connects to the proximal left pulmonary artery, often resulting in stenosis. The PDA is usually elongated and tortuous, making stent implantation challenging. Shorter duration of palliation, aggravation of branch pulmonary artery stenosis resulting in poor growth and difficulty at surgery makes ductal stenting controversial. Access via the carotid and axillary artery reduces complexity of the procedure and improves success, with recent data demonstrating good pulmonary artery growth. Advances in bioresorbable stents offer future promise and will likely resolve some controversies surrounding PDA stenting in ToF-PA.
    Matched MeSH terms: Cardiac Catheterization
  12. Talib N, Sayuti KA, Abdullah MS, Mohd Zain MR
    BMJ Case Rep, 2018 Mar 05;2018.
    PMID: 29507009 DOI: 10.1136/bcr-2017-221074
    Total anomalous pulmonary venous return (TAPVR) is a rare congenital heart defect, and patients are usually symptomatic at a very young age. Survival to adulthood without surgical correction is extremely rare. We report a 33-year-old woman with a heart murmur and a history of a successful pregnancy. Echocardiogram revealed a large atrial septal defect with suspicious pulmonary vein anomaly. Chest radiograph demonstrated classical 'snowman' configuration. Cardiac catheterisation was consistent with anomalous pulmonary venous drainage. Cardiac CT confirmed supracardiac TAPVR, whereby all the pulmonary veins drain into the anomalous vein and finally to the superior vena cava. She remained asymptomatic and underwent a successful surgical repair.
    Matched MeSH terms: Cardiac Catheterization
  13. Shah RP
    Singapore Med J, 2001 Feb;42(2):78-9.
    PMID: 11358196
    Congenital absence of the pericardium is a rare condition,which is frequently missed due its subtle presentation. It may be misdiagnosed as another condition causing right heart dilatation such as an intracardiac shunt. We report the finding of diastolic pressure alternans during cardiac catheterization in this single case report of a patient with congenital total absence of the pericardium. The occurrence of this phenomenon is hypothesized to be due to excessive cardiac hypermobility and paradoxical septal movement. We propose that this finding may be a useful clue to the diagnosis.
    Matched MeSH terms: Cardiac Catheterization
  14. Goh YH
    Perit Dial Int, 2008 11 5;28(6):626-31.
    PMID: 18981393
    BACKGROUND: Omental wrap is a common cause of catheter obstruction. Current laparoscopic techniques for correcting obstruction include omentopexy and omentectomy. This study evaluates the efficacy of a new laparoscopic technique for revision of obstructed peritoneal dialysis catheters.

    METHODS: Between November 2005 and November 2006, the technique was applied in 18 patients (6 female, 12 male; median age 50 years, range 16 - 73 years) on continuous ambulatory peritoneal dialysis with catheter malfunction secondary to omental wrap. Pneumoperitoneum was induced under general anesthesia. Three ports were inserted. The catheter was released from the omentum and repositioned in the pelvis. The omentum was then folded onto itself in a cephalad direction using silk sutures. This shortened the omentum. The risk of catheter migration was minimized with a polypropylene sling passed through the abdominal wall and around the catheter, then knotted subcutaneously. The sling allowed catheter removal without a new laparoscopy. The outcomes were prospectively evaluated.

    RESULTS: Median operating time was 90 minutes (range 35 - 160 minutes). Adhesiolysis was performed in 4 patients: 1 patient had port-site leakage of dialysate, which settled with abdominal rest; 1 patient had bleeding during adhesiolysis and laparoscopic hemostasis was successful; 1 patient had recurrent catheter obstruction 2 weeks post-operatively and was converted to hemodialysis; and 1 patient had recurrent malfunction secondary to small bowel wrap after 5.5 months; re-salvage was successful. The success rate of the first salvage procedure was 89%(16/18). The catheters were still functioning after a mean follow-up of 16.5 +/- 6.3 months (range 0.5 - 24 months). The 1-year catheter survival rate was 83.3%.

    CONCLUSIONS: Omental folding is a safe and effective technique for salvaging peritoneal dialysis catheters.

    Matched MeSH terms: Catheterization
  15. Lai NM, Taylor JE, Tan K, Choo YM, Ahmad Kamar A, Muhamad NA
    Cochrane Database Syst Rev, 2016 Mar 23;3:CD011082.
    PMID: 27007217 DOI: 10.1002/14651858.CD011082.pub2
    BACKGROUND: Central venous catheters (CVCs) provide secured venous access in neonates. Antimicrobial dressings applied over the CVC sites have been proposed to reduce catheter-related blood stream infection (CRBSI) by decreasing colonisation. However, there may be concerns on the local and systemic adverse effects of these dressings in neonates.

    OBJECTIVES: We assessed the effectiveness and safety of antimicrobial (antiseptic or antibiotic) dressings in reducing CVC-related infections in newborn infants. Had there been relevant data, we would have evaluated the effects of antimicrobial dressings in different subgroups, including infants who received different types of CVCs, infants who required CVC for different durations, infants with CVCs with and without other antimicrobial modifications, and infants who received an antimicrobial dressing with and without a clearly defined co-intervention.

    SEARCH METHODS: We used the standard search strategy of the Cochrane Neonatal Review Group (CNRG). We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library 2015, Issue 9), MEDLINE (PubMed), EMBASE (EBCHOST), CINAHL and references cited in our short-listed articles using keywords and MeSH headings, up to September 2015.

    SELECTION CRITERIA: We included randomised controlled trials that compared an antimicrobial CVC dressing against no dressing or another dressing in newborn infants.

    DATA COLLECTION AND ANALYSIS: We extracted data using the standard methods of the CNRG. Two review authors independently assessed the eligibility and risk of bias of the retrieved records. We expressed our results using risk difference (RD) and risk ratio (RR) with 95% confidence intervals (CIs).

    MAIN RESULTS: Out of 173 articles screened, three studies were included. There were two comparisons: chlorhexidine dressing following alcohol cleansing versus polyurethane dressing following povidone-iodine cleansing (one study); and silver-alginate patch versus control (two studies). A total of 855 infants from level III neonatal intensive care units (NICUs) were evaluated, 705 of whom were from a single study. All studies were at high risk of bias for blinding of care personnel or unclear risk of bias for blinding of outcome assessors. There was moderate-quality evidence for all major outcomes.The single study comparing chlorhexidine dressing/alcohol cleansing against polyurethane dressing/povidone-iodine cleansing showed no significant difference in the risk of CRBSI (RR 1.18, 95% CI 0.53 to 2.65; RD 0.01, 95% CI -0.02 to 0.03; 655 infants, moderate-quality evidence) and sepsis without a source (RR 1.06, 95% CI 0.75 to 1.52; RD 0.01, 95% CI -0.04 to 0.06; 705 infants, moderate-quality evidence). There was a significant reduction in the risk of catheter colonisation favouring chlorhexidine dressing/alcohol cleansing group (RR 0.62, 95% CI 0.45 to 0.86; RD -0.09, 95% CI -0.15 to -0.03; number needed to treat for an additional beneficial outcome (NNTB) 11, 95% CI 7 to 33; 655 infants, moderate-quality evidence). However, infants in the chlorhexidine dressing/alcohol cleansing group were significantly more likely to develop contact dermatitis, with 19 infants in the chlorhexidine dressing/alcohol cleansing group having developed contact dermatitis compared to none in the polyurethane dressing/povidone-iodine cleansing group (RR 43.06, 95% CI 2.61 to 710.44; RD 0.06, 95% CI 0.03 to 0.08; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 13 to 33; 705 infants, moderate-quality evidence). The roles of chlorhexidine dressing in the outcomes reported were unclear, as the two assigned groups received different co-interventions in the form of different skin cleansing agents prior to catheter insertion and during each dressing change.In the other comparison, silver-alginate patch versus control, the data for CRBSI were analysed separately in two subgroups as the two included studies reported the outcome using different denominators: one using infants and another using catheters. There were no significant differences between infants who received silver-alginate patch against infants who received standard line dressing in CRBSI, whether expressed as the number of infants (RR 0.50, 95% CI 0.14 to 1.78; RD -0.12, 95% CI -0.33 to 0.09; 1 study, 50 participants, moderate-quality evidence) or as the number of catheters (RR 0.72, 95% CI 0.27 to 1.89; RD -0.05, 95% CI -0.20 to 0.10; 1 study, 118 participants, moderate-quality evidence). There was also no significant difference between the two groups in mortality (RR 0.55, 95% CI 0.15 to 2.05; RD -0.04, 95% CI -0.13 to 0.05; two studies, 150 infants, I² = 0%, moderate-quality evidence). No adverse skin reaction was recorded in either group.

    AUTHORS' CONCLUSIONS: Based on moderate-quality evidence, chlorhexidine dressing/alcohol skin cleansing reduced catheter colonisation, but made no significant difference in major outcomes like sepsis and CRBSI compared to polyurethane dressing/povidone-iodine cleansing. Chlorhexidine dressing/alcohol cleansing posed a substantial risk of contact dermatitis in preterm infants, although it was unclear whether this was contributed mainly by the dressing material or the cleansing agent. While silver-alginate patch appeared safe, evidence is still insufficient for a recommendation in practice. Future research that evaluates antimicrobial dressing should ensure blinding of caregivers and outcome assessors and ensure that all participants receive the same co-interventions, such as the skin cleansing agent. Major outcomes like sepsis, CRBSI and mortality should be assessed in infants of different gestation and birth weight.

    Matched MeSH terms: Catheterization, Central Venous/adverse effects*
  16. Venkatason P, Zubairi YZ, Hafidz I, Wan WA, Zuhdi AS
    Ann Saudi Med, 2016 5 30;36(3):184-9.
    PMID: 27236389 DOI: 10.5144/0256-4947.2016.184
    BACKGROUND: The administration of evidence-based pharmacotherapy and timely primary percutaneous coronary intervention have been shown to improve outcome in ST elevation myocardial infarction (STEMI). However, implementation remains a challenge due to the limitations in facilities, expertise and funding.

    OBJECTIVES: To investigate adherence to guideline-based management and mortality of STEMI patients in Malaysia.

    DESIGN: Retrospective analysis.

    SETTINGS: STEMI patients from 18 participating hospital across Malaysia included in the National Cardiovascular Database-Acute Coronary Syndrome (NCVD-ACS) registry year 2006 to 2013.

    PATIENTS AND METHODS: Patients were categorized into four subgroups based on the year of admission (2006 to 2007, 2008 to 2009, 2010 to 2011 and 2012 to 2013). Baseline characteristics and clinical presentation, in-hospital pharmacotherapy, invasive revascularization and in-hospital/30-day mortality were analysed and compared between the subgroups.

    MAIN OUTCOME MEASURE(S): Rate of in-hospital catheterization/percutaneous coronary intervention.

    RESULTS: The registry contained data on 19483 patients. Intravenous thrombolysis was the main reperfusion therapy. Although the overall rate of in-hospital catheterisation/PCI more than doubled over the study period, while the use of primary PCI only slowly increased from 7.6% in 2006/2007 to 13.6% in 2012/2013. The use of evidence-based oral therapies increased steadily over the years except for ACe-inhibitors and angiotensin-receptor blockers. The adjusted risk ratios (RR) for in-hospital mortality for the four sub-groups have not shown any significant improvement. The 30-day adjusted risk ratios however showed a significant albeit gradual risk reduction (RR 0.773 95% CI 0.679-0.881, P < .001).

    CONCLUSION: Adherence to evidence-based treatment in STEMI in Malaysia is still poor especially in terms of the rate of primary PCI. Although there is a general trend toward reduced 30-day mortality, the reduction was only slight over the study period. Drastic effort is needed to improve adherence and clinical outcomes.

    LIMITATION: Retrospective registry data with inter-hospital variation.

    Matched MeSH terms: Cardiac Catheterization/trends*
  17. Abdelbasit MA, Alwi M, Kandavello G, Che Mood M, Samion H, Hijazi ZM
    Catheter Cardiovasc Interv, 2015 Jul;86(1):94-9.
    PMID: 25675888 DOI: 10.1002/ccd.25878
    OBJECTIVES: To evaluate the feasibility, safety, and efficacy of the Occlutech® PDA occluder for closure of patent ductus arteriosus (PDA).

    BACKGROUND: The Occlutech® PDA occluder is novel, self-shaping Nitinol wire device with PET (polyethylene terephthalate) patches integrated into the shank of the device to assure a better obturation of the ductus. The Occlutech® PDA occluder has undergone two design modifications.

    METHODS: A prospective, non-randomized pilot study was started in November 2011. Thirty-three patients were included until April 2013. Patients weighing <6 kg or those with associated cardiac anomalies that required surgery were excluded. All patients were followed up by transthoracic echocardiography at 24 hr, 30 days, 90 days, 180 days, and 360 days after implantation. Residual shunt, left pulmonary artery (LPA) and descending aortic velocities were among the parameters assessed. All occluders were delivered via 6-8 F long sheaths and PDA closures were performed following standard techniques.

    RESULTS: Thirty three patients (20 female/13 male), with a median age of 2 years (6 month to 38 years), and median weight of 9.3 kg (6-69.2 kg) were included. The narrowest median PDA diameter was 3mm (1.8-5.8 mm). All the 33 patients were closed successfully using Occlutech ductal occluder, 16 patients (48.4%) had immediate and complete closure on angiography. Within 24 hr, color Doppler revealed complete closure in 27patients (81.8%), 32patients (97%) at 30 days, and in 100% of patients at 90 days. All patients with a large PDA had immediate residual shunt which was closed at the 90-day follow-up. There was no device embolization, hemolysis, or obstruction to the LPA or descending aorta.

    CONCLUSION: The new Occlutech® PDA is safe and effective. In patients with a large PDA complete closure tended to take longer time.

    Matched MeSH terms: Cardiac Catheterization
  18. Ahmad F, Sadiq MA, Chee KH, Mahmood Zuhdi AS, Wan Ahmad WA
    J Coll Physicians Surg Pak, 2014 Jun;24(6):441-3.
    PMID: 24953923 DOI: 06.2014/JCPSP.441443
    Pulmonary hypertension is frequently associated with atrial septal defect and various connective tissue disorders. This case describes a 74-year-old woman who presented with symptoms of heart failure and concomitant involvement of salivary glands and keratoconjunctivitis. An echocardiogram demonstrated ostium secundum atrial septal defect with left to right shunt and severe pulmonary hypertension. Laboratory investigations confirmed the diagnosis of Sjögren's syndrome (SS) with positive anti-nuclear factor and centromere SS-A/Ro pattern. Anti-Ro (SS-A) was found positive. Atrial septal defect was closed through transcatheter route with significant improvement in clinical outcome. This case report suggests a possible association of atrial septal defect with primary Sjögren's syndrome in an adult patient.
    Matched MeSH terms: Cardiac Catheterization
  19. Engkasan JP, Ng CJ, Low WY
    Spinal Cord, 2014 Feb;52(2):157-62.
    PMID: 24276416 DOI: 10.1038/sc.2013.145
    STUDY DESIGN: Qualitative study using individual in-depth interviews.
    OBJECTIVES: The objective of this study was to explore the factors influencing the choice of bladder management for male patients with spinal cord injury (SCI).
    SETTING: Public hospitals in Malaysia.
    METHODS: Semistructured (one-on-one) interviews of 17 patients with SCI; 7 were in-patients with a recent injury and 10 lived in the community. All had a neurogenic bladder and were on various methods of bladder drainage. Interviews were audio-recorded, transcribed verbatim and analyzed using thematic analyses.
    RESULTS: The choice of bladder management was influenced by treatment attributes, patients' physical and psychological attributes, health practitioners' influences and social attributes. Participants were more likely to choose a treatment option that was perceived to be convenient to execute and helped maintain continence. The influence of potential treatment complications on decision making was more variable. Health professionals' and peers' opinions on treatment options had a significant influence on participants' decision. In addition, patients' choices depended on their physical ability to carry out the task, the level of family support received and the anticipated level of social activities. Psychological factors such as embarrassment with using urine bags, confidence in self-catheterization and satisfaction with the current method also influenced the choice of bladder management method.
    CONCLUSION: The choice of bladder management in people with SCI is influenced by a variety of factors and must be individualized. Health professionals should consider these factors when supporting patients in making decisions about their treatment options.
    Study design: Qualitative study using individual in-depth interviews.
    Matched MeSH terms: Urinary Catheterization
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links