METHODS: A descriptive, cross-sectional, online study, conducted between October-November 2020, assessed the impact of COVID-19 on HIV prevention and care among people living with HIV (PLHIV), key populations (KPs), and healthcare providers (HCPs). The study populations were recruited across ten Asian countries/territories, covering Hong Kong, India, Japan, Malaysia, Philippines, Singapore, Korea, Taiwan, Thailand, and Vietnam.
RESULTS: Across the region, 702 PLHIV, 551 KPs, and 145 HCPs were recruited. Both PLHIV and KPs reported decreased or had yet to visit hospitals/clinics (PLHIV: 35.9%; KPs: 57.5%), reduced HIV RNA viral load testing (21.9%; 47.3%), and interruptions in antiretroviral therapy (ART) (22.3%) or decreased/complete stop of HIV prevention medication consumption (40.9%). Travel constraints (40.6%), financial issues (28.9%), and not receiving prescription refills (26.9%) were common reasons for interrupted ART access, whereas reduced engagements in behaviours that could increase the risks of HIV acquisition and transmission (57.7%), travel constraints (41.8%), and less hospital/clinic visits (36.7%) underlie the disruptions in HIV preventive medications. Decreased visits from PLHIV/KPs and rescheduled appointments due to clinic closure were respectively reported by 50.7%-52.1% and 15.6%-17.0% of HCPs; 43.6%-61.9% observed decreased ART/preventive medication refills. Although 85.0% of HCPs adopted telemedicine to deliver HIV care services, 56.4%-64.1% of PLHIV/KPs were not using telehealth services.
CONCLUSIONS: The COVID-19 pandemic substantially disrupted HIV prevention to care continuum in Asia at the time of the study. The findings highlighted differences in HIV prevention to care continuum via telehealth services utilisation by PLHIV, KPs, and HCPs. Efforts are needed to optimise infrastructure and adapt systems for continued HIV care with minimal disruptions during health emergency crises.
PURPOSE: This work aimed to develop and characterize chitosan (CS)-polyvinyl alcohol (PVA) blended electrospun multifunctional nanofiber loaded with curcumin (CUR) and zinc oxide (ZnO) to accelerate diabetic wound healing in STZ-induced diabetic rats.
RESULTS: In-vitro characterization results revealed that nanofiber was fabricated successfully using the electrospinning technique. SEM results confirmed the smooth surface with web-like fiber nanostructure diameter ranging from 200 - 250 nm. An in-vitro release study confirmed the sustained release of CUR and ZnO for a prolonged time. In-vitro cell-line studies demonstrated significantly low cytotoxicity of nanofiber in HaCaT cells. Anti-bacterial studies demonstrated good anti-bacterial and anti-biofilm activities of nanofiber. In-vivo animal studies demonstrated an excellent wound-healing efficiency of the nanofibers in STZ-induced diabetic rats. Furthermore, the ELISA assay revealed that the optimized nanofiber membrane terminated the inflammatory phases successfully by downregulating the pro-inflammatory cytokines (TNF-α, MMP-2, and MMP-9) in wound healing. In-vitro and in-vivo studies conclude that the developed nanofiber loaded with bioactive material can promote diabetic wound healing efficiently via multifunction action such as the sustained release of bioactive molecules for a prolonged time of duration, proving anti-bacterial/anti-biofilm properties and acceleration of cell migration and proliferation process during the wound healing.
DISCUSSION: CUR-ZnO electrospun nanofibers could be a promising drug delivery platform with the potential to be scaled up to treat diabetic foot ulcers effectively.