OBJECTIVES: This study was conducted to gain an insight into the experiences and views of poststroke patients and their urut Melayu practitioners.
METHODS: A qualitative study design was adopted. A total of 17 semistructured in-depth interviews were carried out with poststroke patients who were undergoing urut Melayu treatment at one of the three integrated hospitals. Information was solicited from their accompanying caregivers whenever necessary. The 2 urut Melayu practitioners at the hospital were also interviewed. All the interviews were carried out in Malay by the authors, at the Traditional and Complementary Medicine unit of the relevant hospital. The interviews were audiotaped, transcribed, and coded into categories through a constant-comparison method of data analysis. Illustrative quotations were identified to supplement the narrative descriptions of the themes.
RESULTS: It was found that urut Melayu was sought by patients who had experienced stroke brought about by hypertension and postdelivery complications. They reported the unique characteristics of urut Melayu and their positive experiences with it.
CONCLUSIONS: Urut Melayu has potential as a complementary therapy for poststroke patients. It is recommended that the number of practitioners at the Traditional and Complementary Medicine unit be increased to provide the optimum care for poststroke patients.
METHOD: This randomized controlled trial was conducted on 80 nulliparous pregnant women who gave birth in four low-risk maternity clinics in Samarinda, Indonesia, from February to May 2022. The women were randomized into intervention (N=40) and control (N=40) groups based on random allocation. Certified midwives performed shiatsu massages following standard protocols. Pain was assessed using the Numeric Rating Scale, and anxiety was assessed using the Hamilton Anxiety Rating Score at three times including before the intervention (T0), the latent phase (T1), and at transition phase (T2). The impact of the intervention was analyzed using repeated measures analysis of variance by SPSS 26. A p-value less than 0.05 was considered statistically significant.
RESULTS: The intervention group showed a significant reduction in labour pain scores from 6.85±1.00 (T0) to 6.13±0.88 (T1) and 4.78±0.83 (T2) (P<0.001), while the control group showed an increase from 6.85±1.00 (T0) to 8.05±0.64 (T1) and 8.85±0.48 (T2) (P<0.001). Anxiety scores in the intervention group decreased from 28.53±4.41 (T0) to 26.15±3.59 (T1) and 20.65±2.69 (T2) (P<0.001), whereas the control group experienced an increase from 25.55±3.16 (T0) to 27.05±3.36 (T1) and 31.73±3.27 (T2) (P<0.001). The between-subject effects in time levels for labour pain and anxiety in the two study groups had a significant impact (P<0.001).
CONCLUSION: Findings showed that shiatsu massage was effective and safe for relieving pain and reducing anxiety during childbirth of nulliparous women. This research suggests that shiatsu massage can be used as an effective alternative method to relieve pain and anxiety during labour in low risk pregnancies, particularly in settings with limited access to pharmaceutical analgesics.Trial Registration Number: IRCT20220317054316N1.
METHODS: A randomized trial was conducted in a University hospital in Malaysia. Nulliparous women at term who were about to start pushing were randomized to massage during pushing and warm compress to the perineum in between pushes or to standard "hands-off" care. Primary outcome was suturing for perineal injury (episiotomy or tear).
RESULTS: A total of 156 participants were analyzed based on intention to treat. Perineal repair rates were 53/79 (67%) for MassComp versus 70/77 (91%) for control (relative risk [RR] 0.72, 95% confidence interval [CI] 0.61-0.98, number needed to treat for an additional beneficial outcome [NNTb ] 5, 95% CI 2.83-8.62, P
METHODS: This was an observational manikin-based study. A total of 96 participants as well as two types of mechanical compression devices: Lucas-2 and AutoPulse, performed one minute of continuous chest compression on BT-CPEA programmed manikin while the ambulance travelled at different speeds, i.e., idle state, 30km/hr and 60km/hr. Seven outcome variables of chest compression were measured. Performance data of different groups of compressor were compared and analysed using repeated measures analysis of variance (ANOVA).
RESULTS: In manual chest compression, significant variation were noted among different speeds in term of average compression rate (p<0.001), average compression depth (p=0.007), fraction of adequate/insufficient compression depth and fraction of normal hands positioning with p=0.018, 0.022 and 0.034 respectively. Overall, AutoPulse and Lucas-2 were not affected by ambulance speed. Lucas- 2 showed more consistent average compression rate, higher fraction of adequate compression depth and reduced fraction of insufficient compression depth as compared to manual compression with p<0.001, 0.001 and 0.043 respectively.
CONCLUSION: In this study we found that ambulance speed significantly affected certain aspects of manual chest compression most notably compression depth, rate and hand positioning. AutoPulse and Lucas-2 can improve these aspects by providing more consistent compression rate, depth and fraction of adequate compression depth during transport.