AIMS AND METHODS: A randomised controlled, non-blinded, cross-over study involving 38 patients (with colostomies and ileostomies) compared the test device to a similar device from the same manufacturer but without the tape border. The main objective was to assess wear time for non-inferiority as a measure of efficacy. Secondary efficacy assessment included peristomal skin condition using the DET (discolouration, erosion and tissue growth) score and patient acceptability, which was assessed through questionnaires using Likert-scale options. Safety was assessed according to the incidence and intensity of device-related adverse events, and the condition of the peristomal skin.
RESULTS AND CONCLUSION: Analysis of results in the per-protocol population showed an average wear time of 4.5 days for both devices and demonstrated non-inferiority. DET scores were similar in both groups, and both had low rates of device-related adverse events, all of which related to peristomal skin. Patients said the devices were user friendly. While the two devices are similar, some patients may find one with an adhesive tape more suited to their needs.
METHODOLOGY/PRINCIPLE FINDINGS: Multiplexed high-resolution melting assay and DNA sequencing detected five G6PD variants, including G6PD Kaiping, G6PD Vanua Lava, G6PD Coimbra, G6PD Mahidol, and G6PD Kerala-Kalyan. Biochemical and structural characterization revealed that G6PD Coimbra markedly reduced catalytic activity and structural stability, indicating a high susceptibility to drug-induced hemolysis. While Kerala-Kalyan had minor effects, it is possible to develop mild adverse effects when receiving radical treatment. CYP2D6 genotyping was performed using long-range PCR and DNA sequencing, and the phenotypes were predicted using the combination of allelic variants. Decreased and no-function alleles were detected at frequencies of 53.4% and 14.2%, respectively. The most common alleles were CYP2D6*36+*10 (25.6%), *10 (23.9%), and *1 (22.2%). Additionally, 51.1% of the intermediate metabolizers showed CYP2D6*10/*36+*10 as the predominant genotype (15.9%).
CONCLUSIONS/SIGNIFICANCE: Our findings provide insights about genetic variations of G6PD and CYP2D6 in 88 vivax malaria patients from Yala, which may influence the safety and effectiveness of radical treatment. Optimization of 8-aminoquinoline administration may be required for safe and effective treatment in the studied population, which could be a significant challenge in achieving the goal of eliminating malaria.
OBJECTIVES: To systematically evaluate the safety and efficacy of different antiseptic solutions in preventing CRBSI and other related outcomes in neonates with CVC.
SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, and trial registries up to 22 April 2022. We checked reference lists of included trials and systematic reviews that related to the intervention or population examined in this Cochrane Review. SELECTION CRITERIA: Randomised controlled trials (RCTs) or cluster-RCTs were eligible for inclusion in this review if they were performed in the neonatal intensive care unit (NICU), and were comparing any antiseptic solution (single or in combination) against any other type of antiseptic solution or no antiseptic solution or placebo in preparation for central catheter insertion. We excluded cross-over trials and quasi-RCTs.
DATA COLLECTION AND ANALYSIS: We used the standard methods from Cochrane Neonatal. We used the GRADE approach to assess the certainty of the evidence.
MAIN RESULTS: We included three trials that had two different comparisons: 2% chlorhexidine in 70% isopropyl alcohol (CHG-IPA) versus 10% povidone-iodine (PI) (two trials); and CHG-IPA versus 2% chlorhexidine in aqueous solution (CHG-A) (one trial). A total of 466 neonates from level III NICUs were evaluated. All included trials were at high risk of bias. The certainty of the evidence for the primary and some important secondary outcomes ranged from very low to moderate. There were no included trials that compared antiseptic skin solutions with no antiseptic solution or placebo. CHG-IPA versus 10% PI Compared to PI, CHG-IPA may result in little to no difference in CRBSI (risk ratio (RR) 1.32, 95% confidence interval (CI) 0.53 to 3.25; risk difference (RD) 0.01, 95% CI -0.03 to 0.06; 352 infants, 2 trials, low-certainty evidence) and all-cause mortality (RR 0.88, 95% CI 0.46 to 1.68; RD -0.01, 95% CI -0.08 to 0.06; 304 infants, 1 trial, low-certainty evidence). The evidence is very uncertain about the effect of CHG-IPA on CLABSI (RR 1.00, 95% CI 0.07 to 15.08; RD 0.00, 95% CI -0.11 to 0.11; 48 infants, 1 trial; very low-certainty evidence) and chemical burns (RR 1.04, 95% CI 0.24 to 4.48; RD 0.00, 95% CI -0.03 to 0.03; 352 infants, 2 trials, very low-certainty evidence), compared to PI. Based on a single trial, infants receiving CHG-IPA appeared less likely to develop thyroid dysfunction compared to PI (RR 0.05, 95% CI 0.00 to 0.85; RD -0.06, 95% CI -0.10 to -0.02; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 10 to 50; 304 infants). Neither of the two included trials assessed the outcome of premature central line removal or the proportion of infants or catheters with exit-site infection. CHG-IPA versus CHG-A The evidence suggests CHG-IPA may result in little to no difference in the rate of proven CRBSI when applied on the skin of neonates prior to central line insertion (RR 0.80, 95% CI 0.34 to 1.87; RD -0.05, 95% CI -0.22 to 0.13; 106 infants, 1 trial, low-certainty evidence) and CLABSI (RR 1.14, 95% CI 0.34 to 3.84; RD 0.02, 95% CI -0.12 to 0.15; 106 infants, 1 trial, low-certainty evidence), compared to CHG-A. Compared to CHG-A, CHG-IPA probably results in little to no difference in premature catheter removal (RR 0.91, 95% CI 0.26 to 3.19; RD -0.01, 95% CI -0.15 to 0.13; 106 infants, 1 trial, moderate-certainty evidence) and chemical burns (RR 0.98, 95% CI 0.47 to 2.03; RD -0.01, 95% CI -0.20 to 0.18; 114 infants, 1 trial, moderate-certainty evidence). No trial assessed the outcome of all-cause mortality and the proportion of infants or catheters with exit-site infection.
AUTHORS' CONCLUSIONS: Based on current evidence, compared to PI, CHG-IPA may result in little to no difference in CRBSI and mortality. The evidence is very uncertain about the effect of CHG-IPA on CLABSI and chemical burns. One trial showed a statistically significant increase in thyroid dysfunction with the use of PI compared to CHG-IPA. The evidence suggests CHG-IPA may result in little to no difference in the rate of proven CRBSI and CLABSI when applied on the skin of neonates prior to central line insertion. Compared to CHG-A, CHG-IPA probably results in little to no difference in chemical burns and premature catheter removal. Further trials that compare different antiseptic solutions are required, especially in low- and middle-income countries, before stronger conclusions can be made.