OBJECTIVES: This study aimed to describe the factors affecting early and late cochlear implantation.

MATERIALS AND METHODS: A total of 159 patients from the Hospital Canselor Tuanku Muhriz (HCTM) Cochlear Implant Programme were recruited in this retrospective cross-sectional study. All paediatric Cochlear Implant (CI) recipients with pre-lingual deafness were included in this retrospective study. The study was conducted from January 2019 until December 2020. The pre-lingual cochlear implant recipients' data were analysed based on demographics and interval from diagnosis to hearing aid fitting and implantation. The association between the dependent variables with early and late cochlear implantation was compared.

RESULTS: A total of 83 (52%) patients were female. Chinese race constituted most of the patients, which was 90/159 (57%). The majority were from middle-income families (M40); 89 (56%). The most common aetiology of Hearing Loss (HL) was idiopathic; 139 (87%), followed by intrauterine infections, which comprised of congenital CMV; 8 (5%) and congenital Rubella; 1 (1%) and nonspecific intrauterine infection 2 (1%). The relationship between the universal neonatal hearing screening and the interval between diagnosis to implantation was significant (p=0.033). Other variables were not significant.

CONCLUSION: UNHS was a significant factor contributing to early and late implantation. The median age of diagnosis of hearing loss was 18 months (interquartile range; 15); the age of CI was 34 months (interquartile range; 24); the interval from diagnosis to hearing aid was 2 months (interquartile range; 5), and the interval from diagnosis to CI was 16 months (interquartile range; 14).