Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Wong AR, Suhaimi H, Ridzuan MA, Rizal MM, Saedah A
    Singapore Med J, 2009 Oct;50(10):e358-61.
    PMID: 19907875
    We present two infants whose endovascular lines were accidentally cut or fractured, and had to be retrieved via transcatheter means in the cardiac catheterisation laboratory. The first case was a two-month-old infant with transposition of the great arteries, requiring an emergency balloon atrial septostomy. An indwelling vascular catheter that was placed in the right femoral vein was accidentally cut and had migrated into the inferior vena cava, before being retrieved. The second case was a one-week-old neonate who presented with pneumonia at birth, and had a long intravenous catheter placed in the left saphenous vein, which became fractured, and subsequently migrated into the heart. This case presented as a pulmonary embolus with haemodynamic instability, as the catheter had partially obstructed the right ventricular outflow tract. This was later retrieved via transcatheter means.
    Matched MeSH terms: Device Removal*
  2. Sivananthan KS, Raveendran K, Kumar T, Sivananthan S
    Injury, 2000 Jul;31(6):433-4.
    PMID: 10831741
    The removal of broken implanted intramedullary nails secondary to re-fracture or non-union is challenging. In 12 cases a simple and safe method has been used to remove broken implants.
    Matched MeSH terms: Device Removal/methods*
  3. Ng KL, Nawawi O, Lim BK, Htun TH, Dublin N, Razack AH
    Asian J Surg, 2017 Apr;40(2):171-174.
    PMID: 24210538 DOI: 10.1016/j.asjsur.2013.09.012
    Ureteric strictures are common and can be due to benign or malignant causes. Various surgical treatments can be used from minimally invasive endoscopic retrograde JJ stent insertion, balloon dilatation, ureterolithotomy, to open surgical exploration and repair. Memokath 051 stent is a metallic stent designed for long-term ureteral stenting in the management of ureteral strictures. The insertion of this device is usually a straightforward procedure performed endoscopically in a retrograde fashion via cystoscopy. However, this procedure can be difficult in complicated scenarios when the bladder has been removed with neoureteral reimplantations or high-grade strictures. Here, we report a case of Memokath stent insertion complicated by placement difficulties in a lady with ileal conduit due to previous ovarian cancer complicated by vesicovaginal fistula, who presented with malignant stricture of the ureteroileal anastomosis. We describe a simple yet effective antegrade technique to precisely reposition the malpositioned Memokath stent, along with illustrations.
    Matched MeSH terms: Device Removal
  4. Badrul B, Ruslan G
    Med J Malaysia, 2000 Sep;55 Suppl C:93-6.
    PMID: 11200051
    We report a 64 year old man who developed Candida albicans infection following total knee arthroplasty. A two-stage exchange arthroplasty was performed after an initial swab culture grew Acinobacter sp. A scanty growth of yeast was also found from the tissue culture. Intravenous cefuroxime was instituted for six weeks followed by reimplantation four months after the removal. Three weeks after that revision, the prosthesis became infected and a culture of knee aspirate established the diagnosis of Candida albicans infection. Treatment consisted of thorough debridement of the involved joint and oral fluconazole for a year. Infection was never totally resolved and a secondary infection with methicillin resistant staphylococcus aureus then developed. Excision arthroplasty was done at two and a half years after the initial infection. At five years follow-up the infection was quiescent and he had a range of movement of 30 degrees to 70 degrees. Knee brace was used to control the valgus-varus stability.
    Matched MeSH terms: Device Removal
  5. Wan Rahiza, W.M., Nurlia, Y., Abd Rahman, I., Esa, K., Nadia, M.N., Raha, A. R.
    MyJurnal
    Supraglottic airway devices have been used as safe alternatives to endotracheal intubation in appropriate types of surgery. This was a prospective, randomised, single blind study comparing the use of LMA™ and SLIPA™ in terms of ease of insertion, haemodynamic changes and occurrence of adverse effects (e.g. blood stains on the device upon removal and sore throat). A total of 62 ASA I or II patients, aged between 18 to 70 years were recruited for this study. Patients were randomised into two groups; LMA™ and SLIPA™ group. Following induction of anaesthesia, an appropriate sized LMA™ or SLIPA™ was inserted after ensuring adequate depth of anaesthesia. Anaesthesia was maintained with oxygen, nitrous oxide and sevoflurane. The ease of insertion was graded and haemodynamic changes were recorded at 2 minute intervals up to 10 minutes after insertion of the airway devices. The presence of blood stains upon airway device removal at the end of surgery and incidence of sore throat was also recorded. No difficult insertion was experienced in either of these devices. Insertion was either easy [LMA™ 87.1% versus SLIPA™ 80.6% (p = 0.49)] or moderate [LMA™ 12.9% versus SLIPA™ 19.4% (p = 0.16)]. Throughout the study period, the haemodynamic changes that occurred in both groups were not statistically different. Traces of blood were noted on the surface of the device in 9.7% of patients in the SLIPA™ group versus 6.5% of patients in the LMA™ group. The incidence of sore throat was recorded in 12.9% versus 19.4% of patients in the SLIPA™ and the LMA™ groups respectively. These findings were not statistically significant. In conclusion, this study showed no significant differences between the use of LMA™ and SLIPA™ in terms of ease of insertion, haemodynamic changes and adverse effects in patients undergoing minor surgical procedures.
    Matched MeSH terms: Device Removal
  6. Ahmed T, Rahman NA, Alam MK
    Biomed Res Int, 2021;2021:6663683.
    PMID: 33959664 DOI: 10.1155/2021/6663683
    Objective: To compare the orthodontic bracket debonding force and assess the bracket failure pattern clinically between different teeth by a validated prototype debonding device. Materials and Method. Thirteen (13) patients at the end of comprehensive fixed orthodontic treatment, awaiting for bracket removal, were selected from the list. A total of 260 brackets from the central incisor to the second premolar in both jaws were debonded by a single clinician using a validated prototype debonding device equipped with a force sensitive resistor (FSR). Mean bracket debonding forces were specified to ten (10) groups of teeth. Following debonding, Intraoral microphotographs of the teeth were taken by the same clinician to assess the bracket failure pattern using a 4-point scale of adhesive remnant index (ARI). Statistical analysis included one-way ANOVA with post hoc Tukey HSD and independent sample t-test to compare in vivo bracket debonding force, Cohen's kappa (κ), and a nonparametric Kruskal-Wallis test for the reliability and the assessment of ARI scoring.

    Results: A significant difference (p < 0.001) of mean debonding force was found between different types of teeth in vivo. Clinically, ARI scores were not significantly different (p = 0.921) between different groups, but overall higher scores were predominant.

    Conclusion: Bracket debonding force should be measured on the same tooth from the same arch as the significant difference of mean debonding force exists between similar teeth of the upper and lower arches. The insignificant bracket failure pattern with higher ARI scores confirms less enamel damage irrespective of tooth types.

    Matched MeSH terms: Device Removal*
  7. Aryasit O, Ng DS, Goh ASC, Woo KI, Kim YD
    BMC Ophthalmol, 2016 Jul 07;16:94.
    PMID: 27387333 DOI: 10.1186/s12886-016-0287-0
    BACKGROUND: Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported.

    CASE PRESENTATION: This is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35-69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus.

    CONCLUSIONS: Delayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.

    Matched MeSH terms: Device Removal
  8. Rickard CM, Marsh NM, Larsen EN, McGrail MR, Graves N, Runnegar N, et al.
    Lancet, 2021 04 17;397(10283):1447-1458.
    PMID: 33865494 DOI: 10.1016/S0140-6736(21)00351-2
    BACKGROUND: The optimal duration of infusion set use to prevent life-threatening catheter-related bloodstream infection (CRBSI) is unclear. We aimed to compare the effectiveness and costs of 7-day (intervention) versus 4-day (control) infusion set replacement to prevent CRBSI in patients with central venous access devices (tunnelled cuffed, non-tunnelled, peripherally inserted, and totally implanted) and peripheral arterial catheters.

    METHODS: We did a randomised, controlled, assessor-masked trial at ten Australian hospitals. Our hypothesis was CRBSI equivalence for central venous access devices and non-inferiority for peripheral arterial catheters (both 2% margin). Adults and children with expected greater than 24 h central venous access device-peripheral arterial catheter use were randomly assigned (1:1; stratified by hospital, catheter type, and intensive care unit or ward) by a centralised, web-based service (concealed before allocation) to infusion set replacement every 7 days, or 4 days. This included crystalloids, non-lipid parenteral nutrition, and medication infusions. Patients and clinicians were not masked, but the primary outcome (CRBSI) was adjudicated by masked infectious diseases physicians. The analysis was modified intention to treat (mITT). This study is registered with the Australian New Zealand Clinical Trials Registry ACTRN12610000505000 and is complete.

    FINDINGS: Between May 30, 2011, and Dec, 9, 2016, from 6007 patients assessed, we assigned 2944 patients to 7-day (n=1463) or 4-day (n=1481) infusion set replacement, with 2941 in the mITT analysis. For central venous access devices, 20 (1·78%) of 1124 patients (7-day group) and 16 (1·46%) of 1097 patients (4-day group) had CRBSI (absolute risk difference [ARD] 0·32%, 95% CI -0·73 to 1·37). For peripheral arterial catheters, one (0·28%) of 357 patients in the 7-day group and none of 363 patients in the 4-day group had CRBSI (ARD 0·28%, -0·27% to 0·83%). There were no treatment-related adverse events.

    INTERPRETATION: Infusion set use can be safely extended to 7 days with resultant cost and workload reductions.

    FUNDING: Australian National Health and Medical Research Council.

    Matched MeSH terms: Device Removal/economics
  9. Kiat Ang C, Leung DY, Lo S, French JK, Juergens CP
    Int J Cardiol, 2007 Apr 4;116(3):321-6.
    PMID: 16904773
    There is no consensus with respect to the use of analgesia during femoral arterial sheath removal after percutaneous coronary intervention (PCI). We performed a randomized controlled trial to assess the impact of intravenous sedation and local anesthesia during femoral sheath removal after PCI on patient comfort and the incidence of vasovagal reactions.
    Matched MeSH terms: Device Removal/adverse effects*
  10. Rajaran JR, Nazimi AJ, Rajandram RK
    BMJ Case Rep, 2017 Sep 27;2017.
    PMID: 28954756 DOI: 10.1136/bcr-2017-221892
    Surgical removal of impacted mandibular third molar is a routine procedure in oral surgery. Various iatrogenic complications related to the procedure has been discussed well in the literatures before. Some of these complications are related to the wrong usage of instruments and techniques. Here we discuss a rare complication on a 42-year-old male, related to the use of high-speed handpiece drill in mandibular third molar removal in a general dental office setting. He was referred when a high speed tungsten carbide bur was accidentally broken and displaced into the mandibular bone during surgical procedure. It is not common to use a high-speed handpiece in impacted third molar removal. This iatrogenic complication could have been totally avoided with the use of proper equipment and technique; therefore raising awareness regarding wrong usage of instrument is vital to avoid similar incidents in the future.
    Matched MeSH terms: Device Removal
  11. Wong CM, Ng KP, Keng TC, Lim SK, Tan SY
    Perit Dial Int, 2011 3 24;31(2):194-6.
    PMID: 21427247 DOI: 10.3747/pdi.2009.00237
    Matched MeSH terms: Device Removal/statistics & numerical data
  12. Yew KL
    Med J Malaysia, 2012 Dec;67(6):618-9.
    PMID: 23770958 MyJurnal
    We are seeing more implantation of cardiac device such as pacemakers and defibrillators and also cardiac implantable electronic device infection. The infection may affect just the pocket site or progress to deeper infection and bacteraemia. Inadequately treated infection may lead to right sided endocarditis, cardiotomy for pacemaker explantation and increased cost and length of stay in the hospital. We report a Staphylococcal infection of a pacemaker system, its successful medical and surgical management.
    Matched MeSH terms: Device Removal
  13. Lim AK, Goh PP, Azura R, Mariam I
    J Cataract Refract Surg, 2011 Apr;37(4):655-9.
    PMID: 21420589 DOI: 10.1016/j.jcrs.2010.10.050
    PURPOSE: To determine the prevalence of and risk factors for AcriFlex 50CSE hydrophilic acrylic intraocular lens (IOL) opacification approximately 3 years after implantation.
    SETTING: Selayang Hospital, Selangor, Malaysia.
    DESIGN: Cross-sectional study.
    METHODS: Patients who had AcriFlex 50CSE IOL implantation in 2005 and 2006 were identified from operating logbooks and recalled via telephone and letters. Opaque IOLs were explanted and sent for scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS).
    RESULTS: The review showed that 18 patients had died and 67 had declined examination or could not be contacted, leaving 239 eyes for evaluation. The age of the patients ranged from 25 to 85 years. Of the patients, 83 (34.7%) were Malay, 127 (53.1%) Chinese, and 29 (12.1%) East Indian. The male:female ratio was 1:1. Fourteen eyes of 13 patients (5.4%) had IOL opacification; 1 had bilateral opacification. Five eyes had fine deposits, and 9 eyes had dense opaque deposits. Seven opaque IOLs required explantation. There was no correlation between age (P=.645), sex (P=.319), or race (P=.860) and IOL opacification. Pearson chi-square analysis showed a strong association between diabetes mellitus and IOL opacification (P=.019). Nine (69.2%) of the 13 patients with opacification had diabetes. Scanning electron microscopy and EDS showed calcium and phosphate deposits on the optic surface and intralenticularly near the anterior surface of the optic.
    CONCLUSIONS: Results indicate that diabetes mellitus is a risk factor for AcriFlex hydrophilic acrylic IOL opacification. In some cases, opacification affected vision, necessitating explantation. The pathophysiology of this complication is unknown.
    FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
    Matched MeSH terms: Device Removal
  14. Ho YL, Jamaluddin MF, Krishinan S, Salleh A, Khamis AY, Abdul Kareem BA
    Asian Cardiovasc Thorac Ann, 2020 Mar;28(3):152-157.
    PMID: 32122151 DOI: 10.1177/0218492320910932
    Matched MeSH terms: Device Removal
  15. Tan PC, Mackeen A, Khong SY, Omar SZ, Noor Azmi MA
    Sci Rep, 2016 Mar 18;6:23223.
    PMID: 26987593 DOI: 10.1038/srep23223
    A peripheral intravenous catheter is often inserted as part of care during labour. The catheter is inserted into the back of the hand or lower forearm vein in usual practice. There is no trial data to guide the care provider on which is the better insertion site in any clinical setting. 307 women admitted to the labour ward who required insertion of intravenous catheter were randomised to back of hand or lower forearm vein catheter insertion. Catheter insertion is by junior to mid-grade providers. We evaluated insertion success at the first attempt, pain during insertion and catheter replacement due to malfunction as main outcomes. After catheter removal, we recorded patient satisfaction with site, future site preference and insertion site swelling, bruising, tenderness, vein thrombosis and pain. Insertion of a catheter into back of hand vein is more likely to be successful at the first attempt. Insertion pain score, catheter replacement rate, patient satisfaction, patient fidelity to site in a future insertion and insertion site complications rate are not different between trial arms. In conclusion, both insertion sites are suitable; the back of the hand vein maybe easier to cannulate and seems to be preferred by our frontline providers.
    Matched MeSH terms: Device Removal
  16. Tee HP, James MW, Kaffes AJ
    World J Gastroenterol, 2010 Jul 28;16(28):3597-600.
    PMID: 20653071
    Postoperative biliary strictures are the most common cause of benign biliary stricture in Western countries, secondary to either operative injury or bile duct anastomotic stricture following orthotopic liver transplantation (OLT). Surgery or endoscopic interventions are the mainstay of treatment for benign biliary strictures. We aim to report the outcome of 2 patients with refractory anastomotic biliary stricture post-OLT, who had successful temporary placement of a prototype removable covered self-expandable metal stent (RCSEMS). These 2 patients (both men, aged 44 and 53 years) were given temporary placement of a prototype RCSEMS (8.5 Fr gauge delivery system, 8 mm x 40 mm stent dimensions) in the common bile duct across the biliary stricture. There was no morbidity associated with stent placement and removal in these 2 cases. Clinical parameters improved after the RCSEMS placement. Long-term biliary patency was achieved in both the patients. No further biliary intervention was required within 14 and 18 mo follow-up after stent removal.
    Matched MeSH terms: Device Removal
  17. Chendran P, Seng Fai T, Wan Abdul Halim WH, Md Din N
    J Glaucoma, 2019 10;28(10):e162-e164.
    PMID: 31368915 DOI: 10.1097/IJG.0000000000001334
    Ocular pyogenic granuloma is a benign tumor seen after ocular insult secondary to ocular surgeries, trauma or infection. Although benign, intervention is sometimes necessary. Previous authors have reported pyogenic granuloma formation following oculoplastic surgeries. We report a pyogenic granuloma after an Ahmed glaucoma valve implantation. A 65-year-old gentleman presented with right eye redness associated with pain and swelling ~2 months after Ahmed glaucoma valve implantation. Examination found a sessile growth on the tube extruding puss with signs of endophthalmitis. The glaucoma drainage device was explanted and culture results grew Staphylococcus aureus. This article discusses the formation of pyogenic granuloma on a glaucoma drainage device and its management.
    Matched MeSH terms: Device Removal
  18. Nurul Ain Mohamed Yusof, Mohd Salman Masri, Erni Noor
    Compendium of Oral Science, 2018;5(1):46-53.
    MyJurnal
    Introduction: High survival rates of dental implants were commonly reported even after 10 years of follow up. Nevertheless, complications and failure may occur and the implant would need to be removed. In recent years, the use of autogenous blood products in dental surgery has increased due to its ability to aid the healing of the soft and hard tissues. Clinical case: The case demonstrated the utilisation of concentrated growth factor (CGF) from the patient’s blood for healing following conservative removal of a failed dental implant. Subsequently, the patient showed satisfactory recovery without any infections and clinical complaints. Conclusion: This explantation procedure, together with the use of CGF, may prevent the normal bone resorption and accelerate soft tissue healing. As it is biological in nature having originated from the patient’s blood, it is more readily accepted by the tissues and the risk of infection is low.
    Matched MeSH terms: Device Removal
  19. Yii RSL, Chuah KH, Poh KS, Lau PC, Ng KL, Ho SH, et al.
    Dig Dis Sci, 2022 01;67(1):344-347.
    PMID: 33491164 DOI: 10.1007/s10620-021-06835-4
    Matched MeSH terms: Device Removal/methods*
  20. Xiao Hong C, Abd Wahab S, Azman M
    BMJ Case Rep, 2020 Oct 27;13(10).
    PMID: 33109696 DOI: 10.1136/bcr-2020-236484
    Penetrating foreign body in the head and neck can be catastrophic from injury to the constellation of vascular and neural structures in the neck. Early recognition and prompt surgical intervention is imperative to save lives. Herein, we present an unusual case of iatrogenic foreign body-a coiled guidewire embedded in the deep neck space. The complications, radiological investigation and multidisciplinary surgical management are further discussed.
    Matched MeSH terms: Device Removal/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links