Displaying publications 1 - 20 of 33 in total

Abstract:
Sort:
  1. Mohamed MH
    Med J Malaysia, 2004 May;59 Suppl B:19-20.
    PMID: 15468798
    One of the emerging technologies in the area of plasma processing is plasma immersion ion implantation (PSII). The paper addresses the merits offered by the PSII technique especially in the area of biomaterial processing. Worldwide development status as well as the drive towards commercial applications is elaborated in an attempt to draw the attention to the importance of the process for Malaysia as well as south East Asia.
    Matched MeSH terms: Electromagnetic Fields*
  2. Keow MA, Radiman S
    Radiat Prot Dosimetry, 2006;121(2):122-7.
    PMID: 16357026
    Radiofrequency (RF) and microwave (MW) radiation exposures from the antennas of rooftop-mounted mobile telephone base stations have become a serious issue in recent years due to the rapidly evolving technologies in wireless telecommunication systems. In Malaysia, thousands of mobile telephone base stations have been erected all over the country, most of which are mounted on the rooftops. In view of public concerns, measurements of the RF/MW levels emitted by the base stations were carried out in this study. The values were compared with the exposure limits set by several organisations and countries. Measurements were performed at 200 sites around 47 mobile phone base stations. It was found that the RF/MW radiation from these base stations were well below the maximum exposure limits set by various agencies.
    Matched MeSH terms: Electromagnetic Fields/adverse effects*
  3. Man AK, Shahidan R
    Radiat Prot Dosimetry, 2008;128(4):444-8.
    PMID: 18045796
    This study attempted to estimate the lifelong magnetic field (MF) exposures of a particular group of welders. Exposure was quantified via measurements, observations and interviews. It was found that these welders face a vast range of lifelong MF exposures depending on the welding processes and duration of the welding tasks performed. This may explain the inconsistency in the results of studies of MF exposures on human health. The mere assessing of the MF exposure levels through spot measurements does not give an overall picture of the total amount of exposure received by the welders as some of these workers performed the welding task throughout the day, whereas others performed this as a part of their job. The exposure to various chemicals in the fume may complicate the interpretation of the elevated health risk among the welders.
    Matched MeSH terms: Electromagnetic Fields*
  4. Mailankot M, Kunnath AP, Jayalekshmi H, Koduru B, Valsalan R
    Clinics (Sao Paulo), 2009;64(6):561-5.
    PMID: 19578660
    INTRODUCTION: Mobile phones have become indispensable in the daily lives of men and women around the globe. As cell phone use has become more widespread, concerns have mounted regarding the potentially harmful effects of RF-EMR from these devices.

    OBJECTIVE: The present study was designed to evaluate the effects of RF-EMR from mobile phones on free radical metabolism and sperm quality.

    MATERIALS AND METHODS: Male albino Wistar rats (10-12 weeks old) were exposed to RF-EMR from an active GSM (0.9/1.8 GHz) mobile phone for 1 hour continuously per day for 28 days. Controls were exposed to a mobile phone without a battery for the same period. The phone was kept in a cage with a wooden bottom in order to address concerns that the effects of exposure to the phone could be due to heat emitted by the phone rather than to RF-EMR alone. Animals were sacrificed 24 hours after the last exposure and tissues of interest were harvested.

    RESULTS: One hour of exposure to the phone did not significantly change facial temperature in either group of rats. No significant difference was observed in total sperm count between controls and RF-EMR exposed groups. However, rats exposed to RF-EMR exhibited a significantly reduced percentage of motile sperm. Moreover, RF-EMR exposure resulted in a significant increase in lipid peroxidation and low GSH content in the testis and epididymis.

    CONCLUSION: Given the results of the present study, we speculate that RF-EMR from mobile phones negatively affects semen quality and may impair male fertility.

    Matched MeSH terms: Electromagnetic Fields/adverse effects*
  5. Narayanan SN, Kumar RS, Potu BK, Nayak S, Bhat PG, Mailankot M
    Ups. J. Med. Sci., 2010 May;115(2):91-6.
    PMID: 20095879 DOI: 10.3109/03009730903552661
    The interaction of mobile phone radio-frequency electromagnetic radiation (RF-EMR) with the brain is a serious concern of our society.
    Matched MeSH terms: Electromagnetic Fields*
  6. Faruque MR, Islam MT, Misran N
    Med Eng Phys, 2011 Jun;33(5):646-52.
    PMID: 21216175 DOI: 10.1016/j.medengphy.2010.12.004
    The purpose of this paper is to calculate the specific absorption rate (SAR) reduction in a muscle cube with metamaterial attachment. The finite-difference time-domain (FDTD) method has been used to evaluate the SAR in a realistic anatomically based model of the muscle cube. In this paper, we have designed the single-negative metamaterials from a periodic arrangement of split ring resonators (SRRs). By properly designing the structural parameter of the SRRs, the effective medium parameter can be tuned negative at the 900 MHz and 1800 MHz bands. Numerical results concerning the SAR values in the muscle cube in the presence of resonators exhibit significant SAR reduction. These results can provide useful information when designing safety-compliant mobile communication equipment.
    Matched MeSH terms: Electromagnetic Fields*
  7. Kalani M, Yunus R, Abdullah N
    Int J Nanomedicine, 2011;6:1101-5.
    PMID: 21698077 DOI: 10.2147/IJN.S18979
    The aim of this study was to optimize the different process parameters including pressure, temperature, and polymer concentration, to produce fine small spherical particles with a narrow particle size distribution using a supercritical antisolvent method for drug encapsulation. The interaction between different process parameters was also investigated.
    Matched MeSH terms: Electromagnetic Fields
  8. Balachandran R, Prepageran N, Prepagaran N, Rahmat O, Zulkiflee AB, Hufaida KS
    J Laryngol Otol, 2012 Apr;126(4):345-8.
    PMID: 22310164 DOI: 10.1017/S0022215112000047
    The Bluetooth wireless headset has been promoted as a 'hands-free' device with a low emission of electromagnetic radiation.
    Matched MeSH terms: Electromagnetic Fields/adverse effects*
  9. Syahrizal Salleh, Zulkifli Abd Majid
    MyJurnal
    An AC to DC voltage rectifier and its respective regulator were designed and integrated on a 0.25μm CMOS process. Its input impedance was measured along with the regulated DC output. Input impedance of a series of rectangular coil microstrip antenna on FR4 PCB with outer dimension of 78mm x 41mm was measured. The positive reactance of the antenna was matched at resonance with negative reactance of the integrated rectifier and regulator with addition of external capacitor. Relationship between incidental electromagnetic field in A/m at the coil microstrip antenna all the way to the rectified DC voltage at the output of the regulator is presented. In the context of wireless power transfer, this work focuses on the remote unit that absorbs electromagnetic field generated by another system and converts the energy into DC supply voltage for remote device
    Matched MeSH terms: Electromagnetic Fields
  10. Gasmelseed A, Yunus J
    Prog Biophys Mol Biol, 2014 Jan;114(1):8-12.
    PMID: 24239501 DOI: 10.1016/j.pbiomolbio.2013.10.004
    The interaction of a dipole antenna with a human eye model in the presence of a metamaterial is investigated in this paper. The finite difference time domain (FDTD) method with convolutional perfectly matched layer (CPML) formulation have been used. A three-dimensional anatomical model of the human eye with resolution of 1.25 mm × 1.25 mm × 1.25 mm was used in this study. The dipole antenna was driven by modulated Gaussian pulse and the numerical study is performed with dipole operating at 900 MHz. The analysis has been done by varying the size and value of electric permittivity of the metamaterial. By normalizing the peak SAR (1 g and 10 g) to 1 W for all examined cases, we observed how the SAR values are not affected by the different permittivity values with the size of the metamaterial kept fixed.
    Matched MeSH terms: Electromagnetic Fields*
  11. Hossain MI, Faruque MR, Islam MT
    Prog Biophys Mol Biol, 2015 Nov;119(2):103-10.
    PMID: 25863147 DOI: 10.1016/j.pbiomolbio.2015.03.008
    The aim of this paper is to investigate the effects of the distances between the human head and internal cellular device antenna on the specific absorption rate (SAR). This paper also analyzes the effects of inclination angles between user head and mobile terminal antenna on SAR values. The effects of the metal-glass casing of mobile phone on the SAR values were observed in the vicinity of the human head model. Moreover, the return losses were investigated in all cases to mark antenna performance. This analysis was performed by adopting finite-difference time-domain (FDTD) method on Computer Simulation Technology (CST) Microwave Studio. The results indicate that by increasing the distance between the user head and antenna, SAR values are decreased. But the increase in inclination angle does not reduce SAR values in all cases. Additionally, this investigation provides some useful indication for future design of low SAR mobile terminal antenna.
    Matched MeSH terms: Electromagnetic Fields*
  12. Malek F, Rani KA, Rahim HA, Omar MH
    Sci Rep, 2015;5:13206.
    PMID: 26286015 DOI: 10.1038/srep13206
    Individuals who report their sensitivity to electromagnetic fields often undergo cognitive impairments that they believe are due to the exposure of mobile phone technology. The aim of this study is to clarify whether short-term exposure at 1 V/m to the typical Global System for Mobile Communication and Universal Mobile Telecommunications System (UMTS) affects cognitive performance and physiological parameters (body temperature, blood pressure and heart rate). This study applies counterbalanced randomizing single blind tests to determine if sensitive individuals experience more negative health effects when they are exposed to base station signals compared with sham (control) individuals. The sample size is 200 subjects with 50.0% Idiopathic Environmental Intolerance attributed to electromagnetic fields (IEI-EMF) also known as sensitive and 50.0% (non-IEI-EMF). The computer-administered Cambridge Neuropsychological Test Automated Battery (CANTAB eclipse(TM)) is used to examine cognitive performance. Four tests are chosen to evaluate Cognitive performance in CANTAB: Reaction Time (RTI), Rapid Visual Processing (RVP), Paired Associates Learning (PAL) and Spatial Span (SSP). Paired sample t-test on the other hand, is used to examine the physiological parameters. Generally, in both groups, there is no statistical significant difference between the exposure and sham exposure towards cognitive performance and physiological effects (P's > 0.05).
    Matched MeSH terms: Electromagnetic Fields
  13. Sidhu P, Shankargouda S, Dicksit DD, Mahdey HM, Muzaffar D, Arora S
    J Endod, 2016 Apr;42(4):622-5.
    PMID: 26850688 DOI: 10.1016/j.joen.2015.12.027
    INTRODUCTION: Use of mobile phone has been prohibited in many hospitals to prevent interference with medical devices. Electromagnetic radiation emitted from cellular phones might interfere with electronic working length determination. The purpose of this in vitro study was to evaluate the effect of a smart phone (Samsung Galaxy Note Edge) on working length determination of electronic apex locators (EALs) Propex II and Rootor.

    METHODS: Fifteen intact, non-carious single-rooted teeth were decoronated at the cementoenamel junction. Visually, working length was determined by using a #15 K-file under stereomicroscope (×20). The effect of cellular phones on electronic working length (EWL) was determined under 2 experimental settings: (1) in a closed room with poor signal strength and (2) in a polyclinic set up with good signal strength and 5 conditions: (1) electronically, without cellular phone in room; (2) electronically, with cellular phone in physical contact with EAL; (3) electronically, with mobile phone in physical contact with EAL and in calling mode for a period of 25 seconds; (4) electronically, mobile phone placed at a distance of 40 cm from the EAL; and (5) electronically, mobile phone placed at a distance of 40 cm and in calling mode for a period of 25 seconds. The EWL was measured 3 times per tooth under each condition. Stability of the readings was scored from 1 to 3: (1) good stability, (2) stable reading after 1 attempt, and (3) stable reading after 2 attempts. The data were compared by using analysis of variance.

    RESULTS: The EWL measurements were not influenced by the presence of cellular phone and could be determined under all experimental conditions.

    CONCLUSIONS: Within the limitations of this study, it can be concluded that mobile phones do not interfere with the EWL determination.

    Matched MeSH terms: Electromagnetic Fields
  14. Mirza IA, Abdulhameed M, Vieru D, Shafie S
    Comput Methods Programs Biomed, 2016 Dec;137:149-166.
    PMID: 28110721 DOI: 10.1016/j.cmpb.2016.09.014
    Therapies with magnetic/electromagnetic field are employed to relieve pains or, to accelerate flow of blood-particles, particularly during the surgery. In this paper, a theoretical study of the blood flow along with particles suspension through capillary was made by the electro-magneto-hydrodynamic approach. Analytical solutions to the non-dimensional blood velocity and non-dimensional particles velocity are obtained by means of the Laplace transform with respect to the time variable and the finite Hankel transform with respect to the radial coordinate. The study of thermally transfer characteristics is based on the energy equation for two-phase thermal transport of blood and particles suspension with viscous dissipation, the volumetric heat generation due to Joule heating effect and electromagnetic couple effect. The solution of the nonlinear heat transfer problem is derived by using the velocity field and the integral transform method. The influence of dimensionless system parameters like the electrokinetic width, the Hartman number, Prandtl number, the coefficient of heat generation due to Joule heating and Eckert number on the velocity and temperature fields was studied using the Mathcad software. Results are presented by graphical illustrations.
    Matched MeSH terms: Electromagnetic Fields*
  15. Yap, Hui Cin, Asmah Hamid, Farah Wahida Ibrahim, Nor Fadilah Rajab, Yanti Rosli
    MyJurnal
    The emergence of research about the biological effects of electromagnetic field (EMF) have growing concern among
    researchers. The aim of this study was to investigate the effects on the brain of rats periodically exposed to 0.1 mT EMF.
    Total 24 adult male Sprague Dawley rats were subdivided randomly to 4 groups: 2 control groups (C1 6 hours: 6 h/
    day for 5 days; C2 20 hours: 20 h/day for 5 days) and 2 treatment groups which exposed to 0.1 mT EMF (T1 6 hours:
    6 h/day for 5 days; T2 20 hours: 20 h/day for 5 days). A significant decrease in the pyramidal cell number was higher
    as the exposure duration to EMF was extended (T1, p
    Matched MeSH terms: Electromagnetic Fields
  16. Parate D, Franco-Obregón A, Fröhlich J, Beyer C, Abbas AA, Kamarul T, et al.
    Sci Rep, 2017 08 25;7(1):9421.
    PMID: 28842627 DOI: 10.1038/s41598-017-09892-w
    Pulse electromagnetic fields (PEMFs) have been shown to recruit calcium-signaling cascades common to chondrogenesis. Here we document the effects of specified PEMF parameters over mesenchymal stem cells (MSC) chondrogenic differentiation. MSCs undergoing chondrogenesis are preferentially responsive to an electromagnetic efficacy window defined by field amplitude, duration and frequency of exposure. Contrary to conventional practice of administering prolonged and repetitive exposures to PEMFs, optimal chondrogenic outcome is achieved in response to brief (10 minutes), low intensity (2 mT) exposure to 6 ms bursts of magnetic pulses, at 15 Hz, administered only once at the onset of chondrogenic induction. By contrast, repeated exposures diminished chondrogenic outcome and could be attributed to calcium entry after the initial induction. Transient receptor potential (TRP) channels appear to mediate these aspects of PEMF stimulation, serving as a conduit for extracellular calcium. Preventing calcium entry during the repeated PEMF exposure with the co-administration of EGTA or TRP channel antagonists precluded the inhibition of differentiation. This study highlights the intricacies of calcium homeostasis during early chondrogenesis and the constraints that are placed on PEMF-based therapeutic strategies aimed at promoting MSC chondrogenesis. The demonstrated efficacy of our optimized PEMF regimens has clear clinical implications for future regenerative strategies for cartilage.
    Matched MeSH terms: Electromagnetic Fields*
  17. Faizal Mohamed, Irman Abdul Rahman, Ngu, Thieng Kui, Syazwani Mohd Fadzil, Firdaus Pozi, Amran Ab. Majid, et al.
    MyJurnal
    Electricity has become one of the necessities for human daily activities. The presence of electric
    current produces electromagnetic fields (EMF) at extremely low frequency (ELF). The problem arises
    when scientists suggests a possible connection between ELF exposure to human health and safety.
    Concerned about the safety and health of students and staff, Universiti Kebangsaan Malaysia (UKM)
    took the initiative to identify possible ELF sources and measure their exposure in various locations
    around the UKM main campus in Bangi. This paper reports the results obtained from the monitoring
    of the magnetic flux density at three identified locations in the vicinity of the overhead high-voltage
    transmission line which transverses the university compound and compare the maximum value results
    with the exposure limit suggested by the International Committee on Non Ionising Radiation
    Protection (ICNIRP) for ELF. Measurements were done with an (Extech) Three Axis
    Electromagnetic Field (EMF) Meter (Model 430826) to determine the magnetic flux density. The
    lateral profile method was applied as the standard measurement methodology. Results showed that the
    maximum value of the magnetic flux density was 12.5 mG, which is below the suggested ICNIRP
    public exposure limit of 1000 mG, or in percentage ratio, 1.25% of ICNIRP public exposure limit.
    Results from the statistical Kruskal-Wallis test showed that there is a significant difference in the
    distributions of the magnetic flux densities at the different locations (P < 0.05). In conclusion, the
    measured locations are still safe for people in short-term exposure. However, long-term exposure
    measurements still need to be done to provide concrete data on the ELF-emission levels in UKM.
    Matched MeSH terms: Electromagnetic Fields
  18. Alahnomi RA, Zakaria Z, Ruslan E, Ab Rashid SR, Mohd Bahar AA, Shaaban A
    PLoS One, 2017;12(9):e0185122.
    PMID: 28934301 DOI: 10.1371/journal.pone.0185122
    A novel symmetrical split ring resonator (SSRR) based microwave sensor with spurline filters for detecting and characterizing the properties of solid materials has been developed. Due to the weak perturbation in the interaction of material under test (MUT) and planar microwave sensor, spurline filters were embedded to the SSRR microwave sensor which effectively enhanced Q-factor with suppressing the undesired harmonic frequency. The spurline filter structures force the presented sensor to resonate at a fundamental frequency of 2.2 GHz with the capabilities of suppressing rejected harmonic frequency and miniaturization in circuit size. A wide bandwidth rejection is achieved by using double spurlines filters with high Q-factor achievement (up to 652.94) compared to single spurline filter. The new SSRR sensor with spurline filters displayed desired properties such as high sensitivity, accuracy, and performance with a 1.3% typical percentage error in the measurement results. Furthermore, the sensor has been successfully applied for detecting and characterizing solid materials (such as Roger 5880, Roger 4350, and FR4) and evidently demonstrated that it can suppress the harmonic frequency effectively. This novel design with harmonic suppression is useful for various applications such as food industry (meat, fruit, vegetables), biological medicine (derived from proteins and other substances produced by the body), and Therapeutic goods (antiseptics, vitamins, anti-psychotics, and other medicines).
    Matched MeSH terms: Electromagnetic Fields
  19. Hashim R, Zahid NI, Velayutham TS, Aripin NFK, Ogawa S, Sugimura A
    J Oleo Sci, 2018 Jun 01;67(6):651-668.
    PMID: 29760332 DOI: 10.5650/jos.ess17261
    Also recognized as carbohydrate liquid crystals, glycolipids are amphiphiles whose basic unit comprises of a sugar group attached to an alkyl chain. Glycolipids are amphitropic, which means these materials form liquid crystal self-assemblies when dry (thermotropic) as well as when dissolved in solvents (lyotropic/surfactants) such as water. Many glycolipids are also naturally derived since these can be found in cell membranes. Their membrane and surfactant functions are largely understood through their lyotropic properties. While glycolipids are expected to play major roles as eco-friendly surfactants in the global surfactant market, their usefulness as thermotropic liquid crystal material is, to date, unknown, due to relatively lack of research performed and data reported in the literature. Understandably since glycolipids are hygroscopic with many hydroxy groups, removing the last trace water is very challenging. In recent time, with careful lyophilization and more consistent characterization technique, some researchers have attempted serious studies into "dry" or anhydrous glycolipids. Motivated by possible developments of novel thermotropic applications, some results from these studies also provide surprising new understanding to support conventional wisdom of the lyotropic systems. Here we review the dry state of glycosides, a family of glycolipids whose sugar headgroup is linked to the lipid chain via a glycosidic oxygen linker. The structure property relationship of both linear and anhydrous Guerbet glycosides will be examined. In particular, how the variation of sugar stereochemistry (e.g. anomer vs. epimer), the chain length and chain branching affect the formation of thermotropic liquid crystals phases, which not only located under equilibrium but also far from equilibrium conditions (glassy phase) are scrutinized. The dry glycolipid assembly has been subjected to electric and magnetic fields and the results show interesting behaviors including a possible transient current generation.
    Matched MeSH terms: Electromagnetic Fields
  20. Gradoni G, Russer J, Baharuddin MH, Haider M, Russer P, Smartt C, et al.
    Philos Trans A Math Phys Eng Sci, 2018 Oct 29;376(2134).
    PMID: 30373944 DOI: 10.1098/rsta.2017.0455
    This paper reviews recent progress in the measurement and modelling of stochastic electromagnetic fields, focusing on propagation approaches based on Wigner functions and the method of moments technique. The respective propagation methods are exemplified by application to measurements of electromagnetic emissions from a stirred, cavity-backed aperture. We discuss early elements of statistical electromagnetics in Heaviside's papers, driven mainly by an analogy of electromagnetic wave propagation with heat transfer. These ideas include concepts of momentum and directionality in the realm of propagation through confined media with irregular boundaries. We then review and extend concepts using Wigner functions to propagate the statistical properties of electromagnetic fields. We discuss in particular how to include polarization in this formalism leading to a Wigner tensor formulation and a relation to an averaged Poynting vector.This article is part of the theme issue 'Celebrating 125 years of Oliver Heaviside's 'Electromagnetic Theory''.
    Matched MeSH terms: Electromagnetic Fields