Displaying publications 1 - 20 of 43 in total

Abstract:
Sort:
  1. Jambari NN, Wang X, Alcocer M
    Methods Mol Biol, 2017;1592:129-137.
    PMID: 28315216 DOI: 10.1007/978-1-4939-6925-8_10
    Protein microarray is a miniaturized multi-analyte, solid-phased immunoassay where thousands of immobilized individual protein spots on a microscopic slide bind are bound to specific antibodies (immunoglobulins) from serum samples, which are then detected by fluorescent labeling. The image processing and pattern recognition are then quantitatively analyzed using advanced algorithms. Here, we describe the use of an in-house-produced complex protein microarray containing extracts and pure proteins that has been probed with antibodies present in the horse sera and detection by fluorophore-conjugated antibody and data analysis. The flexibility of the number and types of proteins that can be printed on the microarray allows different set of specific IgE immunoassay analysis to be carried out.
    Matched MeSH terms: Immunoassay/methods
  2. Grigg MJ, William T, Barber BE, Parameswaran U, Bird E, Piera K, et al.
    J Clin Microbiol, 2014 Jun;52(6):2053-60.
    PMID: 24696029 DOI: 10.1128/JCM.00181-14
    Plasmodium knowlesi causes severe and fatal malaria in Malaysia. Microscopic misdiagnosis is common and may delay appropriate treatment. P. knowlesi can cross-react with "species-specific" parasite lactate dehydrogenase (pLDH) monoclonal antibodies used in rapid diagnostic tests (RDTs) to detect P. falciparum and P. vivax. At one tertiary-care hospital and two district hospitals in Sabah, we prospectively evaluated two combination RDTs for malaria diagnosis by using both a pan-Plasmodium-pLDH (pan-pLDH)/P. falciparum-specific-pLDH (Pf-pLDH) RDT (OptiMAL-IT) and a non-P. falciparum VOM-pLDH/Pf-HRP2 RDT (CareStart). Differential cross-reactivity among these combinations was hypothesized to differentiate P. knowlesi from other Plasmodium monoinfections. Among 323 patients with PCR-confirmed P. knowlesi (n = 193), P. falciparum (n = 93), and P. vivax (n = 37) monoinfections, the VOM-pLDH individual component had the highest sensitivity for nonsevere (35%; 95% confidence interval [CI], 27 to 43%) and severe (92%; CI, 81 to 100%) P. knowlesi malaria. CareStart demonstrated a P. knowlesi sensitivity of 42% (CI, 34 to 49%) and specificity of 74% (CI, 65 to 82%), a P. vivax sensitivity of 83% (CI, 66 to 93%) and specificity of 71% (CI, 65 to 76%), and a P. falciparum sensitivity of 97% (CI, 90 to 99%) and specificity of 99% (CI, 97 to 100%). OptiMAL-IT demonstrated a P. knowlesi sensitivity of 32% (CI, 25 to 39%) and specificity of 21% (CI, 15 to 29%), a P. vivax sensitivity of 60% (CI, 42 to 75%) and specificity of 97% (CI, 94 to 99%), and a P. falciparum sensitivity of 82% (CI, 72 to 89%) and specificity of 39% (CI, 33 to 46%). The combination of CareStart plus OptiMAL-IT for P. knowlesi using predefined criteria gave a sensitivity of 25% (CI, 19 to 32%) and specificity of 97% (CI, 92 to 99%). Combining two RDT combinations was highly specific for P. knowlesi malaria diagnosis; however, sensitivity was poor. The specificity of pLDH RDTs was decreased for P. vivax and P. falciparum because of P. knowlesi cross-reactivity and cautions against their use alone in areas where P. knowlesi malaria is endemic. Sensitive P. knowlesi-specific RDTs and/or alternative molecular diagnostic tools are needed in areas where P. knowlesi malaria is endemic.
    Matched MeSH terms: Immunoassay/methods
  3. Jahangir MA, Gilani SJ, Muheem A, Jafar M, Aslam M, Ansari MT, et al.
    Pharm Nanotechnol, 2019;7(3):234-245.
    PMID: 31486752 DOI: 10.2174/2211738507666190429113906
    BACKGROUND: The amalgamation of biological sciences with nano stuff has significantly expedited the progress of biological strategies, greatly promoting practical applications in biomedical fields.

    OBJECTIVE: With distinct optical attributes (e.g., robust photostability, restricted emission spectra, tunable broad excitation, and high quantum output), fluorescent quantum dots (QDs) have been feasibly functionalized with manageable interfaces and considerably utilized as a new class of optical probe in biological investigations.

    METHODS: In this review article, we structured the current advancements in the preparation methods and attributes of QDs. Furthermore, we extend an overview of the outstanding potential of QDs for biomedical research and radical approaches to drug delivery.

    CONCLUSION: Notably, the applications of QDs as smart next-generation nanosystems for neuroscience and pharmacokinetic studies have been explained. Moreover, recent interests in the potential toxicity of QDs are also apprised, ranging from cell investigations to animal studies.

    Matched MeSH terms: Immunoassay/methods
  4. Zaborowski MP, Lee K, Na YJ, Sammarco A, Zhang X, Iwanicki M, et al.
    Cell Rep, 2019 Apr 02;27(1):255-268.e6.
    PMID: 30943406 DOI: 10.1016/j.celrep.2019.03.003
    Analysis of cancer-derived extracellular vesicles (EVs) in biofluids potentially provides a source of disease biomarkers. At present there is no procedure to systematically identify which antigens should be targeted to differentiate cancer-derived from normal host cell-derived EVs. Here, we propose a computational framework that integrates information about membrane proteins in tumors and normal tissues from databases: UniProt, The Cancer Genome Atlas, the Genotype-Tissue Expression Project, and the Human Protein Atlas. We developed two methods to assess capture of EVs from specific cell types. (1) We used palmitoylated fluorescent protein (palmtdTomato) to label tumor-derived EVs. Beads displaying antibodies of interest were incubated with conditioned medium from palmtdTomato-expressing cells. Bound EVs were quantified using flow cytometry. (2) We also showed that membrane-bound Gaussia luciferase allows the detection of cancer-derived EVs in blood of tumor-bearing animals. Our analytical and validation platform should be applicable to identify antigens on EVs from any tumor type.
    Matched MeSH terms: Immunoassay/methods
  5. Chong YM, Tan XH, Hooi PS, Lee LM, Sam IC, Chan YF
    J Med Virol, 2019 08;91(8):1562-1565.
    PMID: 31032971 DOI: 10.1002/jmv.25495
    Rapid diagnosis of influenza is important for early treatment and institution of control measures. In developing tropical countries such as Malaysia, influenza occurs all year round, but molecular assays and conventional techniques (such as immunofluorescence and culture) for diagnosis are not widely available. Rapid influenza diagnostic tests (RIDTs) may be useful in this setting. A total of 552 fresh respiratory specimens were assessed from patients with respiratory symptoms at a teaching hospital in Kuala Lumpur, Malaysia from November 2017 to March 2018. Two digital immunoassays (DIAs), STANDARD F Influenza A/B Fluorescence Immunoassay (STANDARD F) and Sofia Influenza A + B Fluorescence Immunoassay (Sofia) and one conventional RIDT (immunochromatographic assay), SD Bioline Influenza Ag A/B/A(H1N1) Pandemic rapid test kit (SD Bioline) were evaluated in comparison with a WHO-recommended reverse transcription quantitative PCR (RT-qPCR). Of the 552 samples, influenza A virus was detected in 47 (8.5%) and influenza B virus in 7 (1.3%). The digital immunoassays STANDARD F and Sofia had significantly higher overall sensitivity rates (71.7% and 70.6%, respectively) than the conventional RIDT SD Bioline and immunofluorescence/viral culture (55.8% and 52.8%, respectively). Sensitivity rates were higher for influenza A than influenza B, and specificity rates were uniformly high, ranging from 98% to 100%. Digital readout RIDTs can be used in tropical settings with year-round influenza if PCR is unavailable.
    Matched MeSH terms: Immunoassay/methods*
  6. Fry SR, Meyer M, Semple MG, Simmons CP, Sekaran SD, Huang JX, et al.
    PLoS Negl Trop Dis, 2011 Jun;5(6):e1199.
    PMID: 21713023 DOI: 10.1371/journal.pntd.0001199
    BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1) has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum.
    AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test.
    METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples.
    KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6%) and 96% (95% CI: 92.2% to 99.8) respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1%) and 96.7% specificity (95% CI: 82.8% to 99.9%) compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers.
    CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.
    Matched MeSH terms: Immunoassay/methods
  7. Kremastinou J, Polymerou V, Lavranos D, Aranda Arrufat A, Harwood J, Martínez Lorenzo MJ, et al.
    J Clin Microbiol, 2016 09;54(9):2330-6.
    PMID: 27358468 DOI: 10.1128/JCM.02544-15
    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results.
    Matched MeSH terms: Immunoassay/methods*
  8. Ho TM, DeBruynne J, Ahamad M, Darussamin H
    Asian Pac J Allergy Immunol, 1997 Sep;15(3):123-6.
    PMID: 9438543
    The MAST CLA system was evaluated against skin prick test (SPT) for diagnosis of allergies to house dust mites (Dermatophagoides pteronyssinus, Dermatophagoides farinae) and cats. Forty three asthmatic children were examined by SPT and MAST CLA. Chi-square analysis indicated significant association between SPT and MAST CLA results for the house dust mites but not for cats. The sensitivities of MAST CLA for house dust mites and cats were 100 and 25% respectively; specificities were all less than 50%. The efficiency of MAST CLA for detection of allergy to the house dust mites was 88% and 44% for cats. A significant linear correlation was found between SPT wheal size and MAST CLA grade for D. farinae but not for D. pteronyssinus and cats. It is concluded that the MAST CLA allergy system can be used to supplement SPT for diagnosis of allergies to house dust mites but not to cats.
    Matched MeSH terms: Immunoassay/methods*
  9. Bador KM, Intan S, Hussin S, Gafor AH
    Lupus, 2012 Oct;21(11):1172-7.
    PMID: 22652631 DOI: 10.1177/0961203312450085
    Previous studies in systemic lupus erythematosus (SLE) patients have produced conflicting results regarding the diagnostic utility of procalcitonin (PCT). The aim of this study was to determine predictive values of PCT and C-reactive protein (CRP) for bacterial infection in SLE patients.
    Matched MeSH terms: Immunoassay/methods
  10. Bhewa Y, Hilmi I, Cheah PL, Navaratnam P, Goh KL
    J Dig Dis, 2007 Nov;8(4):207-10.
    PMID: 17970878
    Although well established in the West, stool antigen tests (SAT) are not widely used in Asia. Data on the accuracy of this test in Asia is sparse and, to date, there have been no studies looking at the more refined monoclonal SAT. The aim of this study is to validate the diagnostic accuracy of a stool antigen test, Hp STAR, for the detection of Helicobacter pylori.
    Matched MeSH terms: Immunoassay/methods*
  11. Yeang HY, Arif SA, Raulf-Heimsoth M, Loke YH, Sander I, Sulong SH, et al.
    J Allergy Clin Immunol, 2004 Sep;114(3):593-8.
    PMID: 15356563 DOI: 10.1016/j.jaci.2004.05.039
    BACKGROUND:
    Sensitization to natural rubber latex has been linked to proteins from medical latex gloves. Various assays to estimate the amount of residual allergenic proteins extractable from latex gloves to assess their potential exposure hazard have inherent weaknesses.

    OBJECTIVE:
    This investigation was aimed at developing 2-site immunoenzymetric assays and identifying appropriate protein markers to assess the allergenic potential of latex gloves.

    METHODS:
    The presence of 6 latex allergens--Hev b 1, 2, 3, 5, 6, and 13--was measured in a cross-section of commercial latex medical gloves by using monoclonal and polyclonal antibody-based 2-site immunoenzymetric assays. The overall allergenic potential of these gloves was assessed by IgE-inhibition assay. Stepwise multiple regression analyses were performed to identify marker allergens that best explained the variation in latex glove allergenicity.

    RESULTS:
    All 6 latex allergens were detected in at least some of the glove samples. Hev b 5 and Hev b 13 were identified as the marker allergens that combined best to explain the variation in the glove allergenicity. The significant multiple correlation (R=0.855) between these 2 markers and glove allergenic potency forms the basis of an assay to gauge latex glove allergenicity.

    CONCLUSION:
    The overall allergenic potential of latex gloves can be estimated by using Hev b 5 and Hev b 13 as indicator allergens. The correlation between glove allergenicity and the level of these allergens was maintained for low-protein gloves (<200 microg/g). This estimation of glove allergenicity was superior to that obtained by using total protein readings.
    Matched MeSH terms: Immunoassay/methods
  12. Ahmad AL, Low SC, Shukor SR, Ismail A
    J Immunoassay Immunochem, 2012 Jan;33(1):48-58.
    PMID: 22181820 DOI: 10.1080/15321819.2011.591479
    This study was aimed at gaining a quantitative understanding of the effect of protein quantity and membrane pore structure on protein immobilization. The concentration of immobilized protein was measured by staining with Ponceau S and measuring its color intensity. In this study, both membrane morphology and the quantity of deposited protein significantly influenced the quantity of protein immobilization on the membrane surface. The sharpness and intensity of the red protein spots varied depending on the membrane pore structure, indicating a dependence of protein immobilization on this factor. Membranes with smaller pores resulted in a higher color density, corresponding to enhanced protein immobilization and an increased assay sensitivity level. An increased of immobilized volume has a significant jagged outline on the protein spot but, conversely, no difference in binding capacity.
    Matched MeSH terms: Immunoassay/methods*
  13. Islam AH, Singh KK, Ismail A
    Diagn Microbiol Infect Dis, 2011 Jan;69(1):38-44.
    PMID: 21146712 DOI: 10.1016/j.diagmicrobio.2010.09.008
    Acinetobacter baumannii is an emerging nosocomial pathogen that is resistant to many types of antibiotics, and hence, a fast, sensitive, specific, and economical test for its rapid diagnosis is needed. Development of such a test requires a specific antigen, and outer membrane proteins (OMPs) are the prime candidates. The goal of this study was to find a specific OMP of A. baumannii and demonstrate the presence of specific IgM, IgA, and IgG against the candidate protein in human serum. OMPs of A. baumannii ATCC 19606 and 16 other clinical isolates of A. baumannii were extracted from an overnight culture grown at 37 °C. Protein profiles were obtained using sodium dodecyl sulfate polyacrylamide gel electrophoresis, and Western blot analysis was performed to detect the presence of IgM, IgA, and IgG against the OMP in host serum. An antigenic 34.4-kDa OMP was uniquely recognized by IgM, IgA, and IgG from patients with A. baumannii infection, and it did not cross-react with sera from patients with other types of infection. The band was also found in the other 16 A. baumannii isolates. This 34.4-kDa OMP is a prime candidate for development of a diagnostic test for the presence of A. baumannii.
    Matched MeSH terms: Immunoassay/methods
  14. Kilbourn AM, Godfrey HP, Cook RA, Calle PP, Bosi EJ, Bentley-Hibbert SI, et al.
    J. Wildl. Dis., 2001 Jan;37(1):65-71.
    PMID: 11272506
    Diagnosis of active mycobacterial disease in orangutans (Pongo pygmaeus) has been impeded by high levels of non-specific intradermal skin test reactivity to mycobacterial antigens. This may be due in part to cross reactivity between antigens, tuberculin concentrations used or other species-specific factors. Antigen 85 (Ag85) complex proteins are major secretory products of actively growing mycobacteria, and measurement of serum Ag85 could provide a method for determining active mycobacterial infections that was not dependent on host immunity. Serum Ag85 was measured by dot-immunobinding assay using monoclonal anti-Ag85, purified Ag85 standard and enhanced chemiluminescence technology in coded serum samples from 14 captive orangutans from a zoo in Colorado, 15 semi-captive orangutans in Malaysia, and 19 free-ranging wild orangutans in Malaysia. Orangutans from Colorado (USA) were culture negative for Mycobacterium tuberculosis and M. avium, although all had laboratory suspicion or evidence of mycobacterial infection; median serum Ag85 was 10 microU/ml (range, <0.25-630 microU/ml). Of the semi-captive orangutans, six were skin test reactive and two were culture positive for M. avium on necropsy. Median serum Ag85 for this group was 1,880 microU/ml (0.75-7,000 microU/ml), significantly higher than that of Colorado zoo or free-ranging Malaysian orangutans. Median serum Ag85 in the latter group was 125 microU/ml (range, 0.75-2,500 microU/ml). These data suggest that suggest that additional studies using more specific reagents and more samples from animals of known status are appropriate.
    Matched MeSH terms: Immunoassay/methods
  15. Seenichamy A, Bahaman AR, Mutalib AR, Khairani-Bejo S
    Biomed Res Int, 2014;2014:592858.
    PMID: 24860824 DOI: 10.1155/2014/592858
    Leptospirosis is one of the zoonotic diseases in animals and humans throughout the world. LipL21 is one of the important surface-exposed lipoproteins in leptospires and the most effective cross protective immunogenic antigen. It is widely considered as a diagnostic marker for leptospirosis. In this study, we evaluated the serodiagnostic potential of LipL21 protein of Leptospira interrogans serovar Pomona. We have successfully amplified, cloned, and expressed LipL21 in E. coli and evaluated its specificity by immunoblotting. Purified recombinant LipL21 (rLipL21) was inoculated into rabbits for the production of polyclonal antibody. Characterization of the purified IgG antibody against rLipL21 was performed by cross reactivity assay. Only sera from leptospirosis patients and rabbit hyperimmune sera recognized rLipL21 while the nonleptospirosis control sera showed no reaction in immunoblotting. We confirmed that anti-rLipL21-IgG antibody cross reacted with and detected only pathogenic leptospiral species and it did not react with nonpathogenic leptospires and other bacterial species. Results observed showed that anti-rLipL21-IgG antibody has high specificity and sensitivity to leptospires. The findings indicated that the antibody could be used in a diagnostic assay for detection of leptospires or their proteins in the early phase of infection.
    Matched MeSH terms: Immunoassay/methods
  16. Ang SH, Thevarajah TM, Woi PM, Alias YB, Khor SM
    J Chromatogr B Analyt Technol Biomed Life Sci, 2016 Mar 15;1015-1016:157-165.
    PMID: 26927875 DOI: 10.1016/j.jchromb.2016.01.059
    An immunosensor that operates based on the principles of lateral flow was developed for direct detection of hemoglobin A1c (HbA1c) in whole blood. We utilized colloidal gold-functionalized antibodies to transduce the specific signal generated when sandwich immuno-complexes were formed on the strip in the presence of HbA1c. The number and intensity of the test lines on the strips indicate normal, under control, and elevated levels of HbA1c. In addition, a linear relationship between HbA1c levels and immunosensor signal intensity was confirmed, with a dynamic range of 4-14% (20-130 mmol mol(-1)) HbA1c. Using this linear relationship, we determined the HbA1c levels in blood as a function of the signal intensity on the strips. Measurements were validated using the Bio-Rad Variant II HPLC and DCA Vantage tests. Moreover, the immunosensor was verified to be highly selective for detection of HbA1c against HbA0, glycated species of HbA0, and HbA2. The limit of detection was found to be 42.5 μg mL(-1) (1.35 mmol mol(-1)) HbA1c, which is reasonably sensitive compared to the values reported for microarray immunoassays. The shelf life of the immunosensor was estimated to be 1.4 months when stored at ambient temperature, indicating that the immunoassay is stable. Thus, the lateral flow immunosensor developed here was shown to be capable of performing selective, accurate, rapid, and stable detection of HbA1c in human blood samples.
    Matched MeSH terms: Immunoassay/methods*
  17. Gopinath SC, Tang TH, Citartan M, Chen Y, Lakshmipriya T
    Biosens Bioelectron, 2014 Jul 15;57:292-302.
    PMID: 24607580 DOI: 10.1016/j.bios.2014.02.029
    Sensing applications can be used to report biomolecular interactions in order to elucidate the functions of molecules. The use of an analyte and a ligand is a common set-up in sensor development. For several decades, antibodies have been considered to be potential analytes or ligands for development of so-called "immunosensors." In an immunosensor, formation of the complex between antibody and antigen transduces the signal, which is measurable in various ways (e.g., both labeled and label-free based detection). Success of an immunosensor depends on various factors, including surface functionalization, antibody orientation, density of the antibody on the sensor platform, and configuration of the immunosensor. Careful optimization of these factors can generate clear-cut results for any immunosensor. Herein, current aspects, involved in the generated immunosensors, are discussed.
    Matched MeSH terms: Immunoassay/methods
  18. Ting HY, Sthaneshwar P, Bee PC, Shanmugam H, Lim M
    Pathology, 2019 Aug;51(5):507-511.
    PMID: 31253381 DOI: 10.1016/j.pathol.2019.04.002
    Serum protein (SPE) and immunofixation electrophoresis (IFE) have been extensively validated for the routine use of identifying, characterising and quantifying monoclonal proteins. However, accurate quantitation of IgA monoclonal proteins can be difficult when they migrate in to the β fraction, due to co-migration with transferrin and complement components. The heavy/light chain (HLC) immunoassay is an additional tool for measuring intact immunoglobulin monoclonal proteins. Therefore, we aimed to examine the clinical utility of the HLC assay for the disease monitoring of IgG and IgA multiple myeloma (MM) patients. A total of 177 samples from 30 MM patients (21 IgG and 9 IgA) were analysed retrospectively with median number of six follow up samples per patient (range 3-13). Serum free light chains (sFLC) and HLC were quantified using Freelite and Hevylite immunoassays. Details of M-protein concentration, β-globulin levels, total immunoglobulin levels and disease treatment response were obtained from the laboratory and patient information system. Passing-Bablok regression analysis was performed to compare (i) M-protein quantification with involved HLC (iHLC) and (ii) total immunoglobulin with summated HLC pairs for each immunoglobulin type (e.g., IgGκ+IgGλ). For 127 IgG MM samples, IgG iHLC levels showed a good correlation with SPE quantification (iHLC y=0.96x+4.9; r=0.917) and summated HLC showed a good correlation with total IgG concentration (summated HLC y=0.94x+5.74; r=0.91). In total, 95/127 (75%) IgG MM follow-up samples had an abnormal HLC ratio and 122/127 (96%) had a positive SPE, probably due to the lower sensitivity of HLC assay in detecting clonality in patients with IgG MM. Consistent with this, one patient assigned a very good partial response by International Myeloma Working Group criteria would be assigned a complete response based on HLC measurements. For 50 IgA MM samples, 42/50 (84%) had an abnormal HLC ratio. Conversely, 50/50 (100%) of M-proteins showed β fraction migration and were difficult to accurately quantify by SPE. Therefore, M-protein concentration and iHLC did not correlate as well in IgA MM (y=1.9x-8.4; r=0.8) compared to IgG MM. However, there was good correlation between total IgA and summated IgA HLC (IgAκ+IgAλ y=1.35x-0.33; r=0.95). Of the 8/50 (16%) IgA samples with a normal HLC ratio, 6/8 (75%) were consistent with the disease status being in complete remission. Interestingly, in one IgA MM patient, SPE and IFE were negative, but the serum FLC ratio and involved FLC were highly abnormal, consistent with the presence of light chain escape. Our data suggest HLC measurements could add value to the current disease monitoring of MM patients. In IgG MM patients, the M-protein level correlated well with HLC values. The HLC assay complements the serum FLC assay and is especially useful for monitoring of IgA MM patients who display M-proteins migrating in the β region on SPE.
    Matched MeSH terms: Immunoassay/methods*
  19. Loh Q, Omar N, Glökler J, Lim TS
    Anal Biochem, 2014 Oct 15;463:67-9.
    PMID: 24972268 DOI: 10.1016/j.ab.2014.06.012
    Immunoassays are often coupled to peroxidase activity for antigen detection. Sensitivity and speed of detection has been increased by the advent of hybrid methods such as immuno-PCR (polymerase chain reaction). However, a more simplified immunoassay that retains both colorimetric peroxidase detection and effective DNA amplification in a setting closer to field application conditions has been nonexistent. Here we describe a method that successfully combines a competitive immunoassay with the new isothermal quadruplex-primed amplification (QPA) to generate excess quadruplex reporter molecules with intrinsic peroxidase DNAzyme activity.
    Matched MeSH terms: Immunoassay/methods*
  20. Chin CF, Ler LW, Choong YS, Ong EB, Ismail A, Tye GJ, et al.
    J Microbiol Methods, 2016 Jan;120:6-14.
    PMID: 26581498 DOI: 10.1016/j.mimet.2015.11.007
    Antibody phage display panning involves the enrichment of antibodies against specific targets by affinity. In recent years, several new methods for panning have been introduced to accommodate the growing application of antibody phage display. The present work is concerned with the application of streptavidin mass spectrometry immunoassay (MSIA™) Disposable Automation Research Tips (D.A.R.T's®) for antibody phage display. The system was initially designed to isolate antigens by affinity selection for mass spectrometry analysis. The streptavidin MSIA™ D.A.R.T's® system allows for easy attachment of biotinylated target antigens on the solid surface for presentation to the phage library. As proof-of-concept, a domain antibody library was passed through the tips attached with the Hemolysin E antigen. After binding and washing, the bound phages were eluted via standard acid dissociation and the phages were rescued for subsequent panning rounds. Polyclonal enrichment was observed for three rounds of panning with five monoclonal domain antibodies identified. The proposed method allows for a convenient, rapid and semi-automated alternative to conventional antibody panning strategies.
    Matched MeSH terms: Immunoassay/methods*