Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Neoh YL, Neoh PF, Salleh A, Yusof ZB, Gurusamy B, Ahmad Tajudin LS
    Ann Acad Med Singap, 2018 06;47(6):226-229.
    PMID: 30019068
    Matched MeSH terms: Nerve Fibers/pathology*
  2. Bakri MM, Yahya F, Munawar KMM, Kitagawa J, Hossain MZ
    Arch Oral Biol, 2018 May;89:94-98.
    PMID: 29499561 DOI: 10.1016/j.archoralbio.2018.02.011
    OBJECTIVE: Transient receptor potential vanilloid 4 (TRPV4) has been considered as a mechano-, thermo- and osmo-receptor. Under inflammatory conditions in dental pulp, teeth can become sensitive upon exposure to a variety of innocuous stimuli. The objective of the present study was to investigate the expression of the TRPV4 channel on nerve fibers in human dental pulp of non-symptomatic and symptomatic teeth associated with inflammatory conditions.

    DESIGN: Dental pulp from extracted human permanent teeth was processed for fluorescence immunohistochemistry. Ten asymptomatic (normal) and 10 symptomatic (symptoms associated with pulpitis) teeth were used in this study. Nerve fibers were identified by immunostaining for a marker, protein gene product 9.5, and the cells were counterstained with 4',6-diamidino-2-phenylindole. An anti-TRPV4 antibody was used to trace TRPV4 expression.

    RESULTS: TRPV4 expression was co-localized with the nerve fiber marker. Immunoreactivity for TRPV4 was more intense (p 

    Matched MeSH terms: Nerve Fibers/metabolism*; Nerve Fibers/pathology
  3. Subramaniam S, Jeoung JW, Lee WJ, Kim YK, Park KH
    Jpn. J. Ophthalmol., 2018 Nov;62(6):634-642.
    PMID: 30229404 DOI: 10.1007/s10384-018-0620-7
    PURPOSE: To compare the diagnostic capability of three-dimensional (3D) neuro-retinal rim thickness (NRR) with existing optic nerve head and retinal nerve fiber layer (RNFL) scan parameters using high-definition optical coherence tomography (HD-OCT).

    DESIGN: Retrospective study.

    METHODS: Based on the mean deviation (MD) of the Humphrey Field Analyzer (HFA), the 152 subjects were categorized into mild (MD > - 6 dB, 100), moderate (MD - 6 to - 12 dB, 26), and severe (MD

    Matched MeSH terms: Nerve Fibers/pathology*
  4. Kumar Potu B, Jagadeesan S, Bhat KM, Rao Sirasanagandla S
    Morphologie, 2013 Jun;97(317):31-7.
    PMID: 23806306 DOI: 10.1016/j.morpho.2013.04.004
    The retromolar foramen (RMF) and retromolar canal (RMC) are the anatomical structures of the mandible located in retromolar fossa behind the third molar tooth. This foramen and canal contain neurovascular structures which provide accessory/additional innervation to the mandibular molars and the buccal area. These neurovascular contents of the canal gain more importance in medical and dental practice, because these elements are vulnerable to damage during placement of osteointegrated implants, endodontic treatment and sagittal split osteotomy surgeries and a detailed knowledge of this anatomical variation would be vital in understanding failed inferior alveolar nerve blockage, spread of infection and also metastasis. Although few studies have been conducted in the past showing the incidence and types in different population groups, a lacunae in comprehensive review of this structure is lacking. Though this variation posed challenging situations for the practicing surgeons, it has been quite neglected and the incidence of it is not well presented in all the textbooks. Hence, we made an attempt to provide a consolidated review regarding variations and clinical applications of the RMF and RMC.
    Matched MeSH terms: Nerve Fibers, Myelinated/ultrastructure
  5. Goh. SY, Ropilah, AR, Othmaliza, O, Mushawiahti, M
    MyJurnal
    Diabetic retinopathy is a disease involving microangiopathic changes in response to chronic hyperglycaemia and pan retinal photocoagulation (PRP) is currently the mainstay of treatment for proliferative retinopathy. In the present study, we evaluated the effect of pan retinal photocoagulation (PRP) on retinal nerve fibre layer (RNFL) thickness in patients with diabetic retinopathy using optical coherence tomography (OCT). This was a prospective longitudinal study. Patients with Type 2 diabetes mellitus with proliferative diabetic retinopathy (PDR) or very severe non-(N)PDR requiring laser treatment were included in the study. PRP was performed by a single trained personnel. Peripapillary RNFL located 3.4 mm around the optic disc was evaluated using time-domain OCT. Examination was performed before treatment, and 2 and 4 months after laser treatment. In total, 39 subjects (39 eyes) were recruited into this study. Twenty-nine patients had PDR and 10 had very severe NPDR. Mean age was 54.97 ± 8.38 years. Male and female genders were almost equally distributed with 18 males and 21 females. Median thickness of average RNFL at baseline was 108.8 um (interquartile range [IQR] 35.3). At two months post-procedure, average RNFL thickness significantly increased to 117.4 (IQR 28.6; P = 0.006). Although, other quadrants revealed a similar trend of increasing thickness at two months but it was not significant. At 4 months post-laser treatment, RNFL thickness in all quadrants reduced to baseline levels with insignificant changes of thickness compared to prior to laser treatment. There was also no significant association between changes in RNFL thickness and HbA1c levels (P = 0.77). In conclusion, PRP causes transient thickening of the RNFL which recovers within 4 months post-laser treatment. At the same time, poor sugar control has no direct influence on the RNFL changes after PRP.
    Matched MeSH terms: Nerve Fibers
  6. Lee WW, Tajunisah I, Sharmilla K, Peyman M, Subrayan V
    Invest Ophthalmol Vis Sci, 2013 Nov;54(12):7785-92.
    PMID: 24135757 DOI: 10.1167/iovs.13-12534
    We determined structural retinal nerve fiber layer (RNFL) changes in schizophrenia patients and established if the structural changes were related to the duration of the illness using spectral-domain optical coherence tomography (SD-OCT).
    Matched MeSH terms: Nerve Fibers/pathology*
  7. Mushawiahti, M., Syed Zulkifli, S.Z., Aida Zairani, M.Z., Faridah, H.
    Medicine & Health, 2011;6(2):107-113.
    MyJurnal
    Central corneal thickness plays a major role in the management of many types of glaucoma. Therefore, our aim is to determine the relationship between the severity of glaucoma measured by optical coherence tomography (OCT) and central corneal thickness (CCT) among normal tension and high tension glaucoma patients. This is an observational cross sectional study on 190 patients carried out in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). Three groups of patients were identified; 60 normal tension glaucoma (NTG), 61 primary open angle glaucoma (POAG) and 69 control. Patients were identified based on the glaucomatous visual field changes and previous record of intraocular pressure before treatment. Visual acuity and intraocular pressure measurements were recorded. Specular microscope was used to measure the CCT and the severity of glaucoma was evaluated objectively based on the retinal nerve fibre layer (RNFL) thickness using optical coherence tomography. Results showed NTG patients had significantly thinner cornea, 503.07±32.27µm compared to the control group, 517.45±31.74 µm (p=0.012).
    However, there was no significant difference between the CCT of POAG and NTG groups (p=0.386).Retinal nerve fibre layer (RNFL) thickness was significantly different between the glaucoma and the control groups (p
    Matched MeSH terms: Nerve Fibers
  8. New SH, Leow SN, Vasudevan SK, Idris IB, Tang SF, Din NM
    PLoS One, 2021;16(2):e0246830.
    PMID: 33630879 DOI: 10.1371/journal.pone.0246830
    OBJECTIVE: To evaluate the retinal nerve fiber layer (RNFL) and macular thicknesses and identify systemic risk factors for thinning of these layers in patients with metabolic syndrome (MetS).

    METHODOLOGY: A cross-sectional observational study was performed on patients diagnosed with MetS and compared to normal controls. All patients underwent ophthalmic and anthropometric examination, serological and biochemical blood investigations; and ocular imaging using spectral-domain optical coherence tomography. Patients with ocular pathology were excluded. Unpaired t-test was used to compare mean thickness between the two groups. One-way ANOVA with Bonferroni correction for multiple comparisons was used to compare mean thickness between different tertiles of MetS parameters, and a generalized estimating equation was used to correct for inter-eye correlation and to assess association between mean thickness and covariates.

    RESULTS: Two hundred and forty-eight eyes from 124 participants (1:1 ratio of MetS patients to controls) were included. Age ranged between 30 to 50 years old, and mean age was 40 ± 6.6 years. RNFL thickness was lower globally (93.6 ± 9.9 μm vs 99.0 ± 9.3, p<0.001) and in the inferior (124.5 ± 17.5 μm vs 131.0 ± 16.4 μm, p = 0.002), superior (117.2 ± 16.0 μm vs 126.3 ± 14.4 μm, p<0.001) and temporal (65.5 ± 10.2 μm vs 69.5 ± 9.8, p = 0.002) sectors in MetS patients compared to controls. Only the central (237.0 ± 14.0 μm vs 243.6 ± 18.0 μm, p = 0.002) and inferior parafoveal (307.8 ± 20.9 vs 314.6 ± 14.6, p = 0.004) area of the macula was significantly thinner. The inferior RNFL sector had the most difference (mean difference = 9.1 μm). The Generalized Estimating Equation found that, after adjusting for age, diastolic blood pressure, BMI, HDL and obesity; the number of MetS components and elevated triglyceride levels were independent risk factors for reduced thickness in global RNFL (β = -4.4, 95% CI = -7.29 to -1.5, p = 0.003) and inferior parafovea (β = -6.85, 95% CI = -11.58 to -2.13, p = 0.004) thickness respectively.

    CONCLUSION: RNFL thinning was seen more than macula thinning in MetS patients, suggesting RNFL susceptibility to neurodegeneration than the macula. A higher number of metabolic components and elevated triglyceride levels were independent risk factors for retinal thinning in this group of patients.

    Matched MeSH terms: Nerve Fibers/pathology*
  9. Md Din N, Tomkins-Netzer O, Talat L, Taylor SR, Isa H, Bar A, et al.
    J Glaucoma, 2016 07;25(7):598-604.
    PMID: 26900824 DOI: 10.1097/IJG.0000000000000379
    PURPOSE: To determine risk factors for intraocular pressure (IOP) elevation and glaucoma in children with nonjuvenile idiopathic arthritis-related uveitis and any IOP-related changes in the retinal nerve fiber layer (RNFL) thickness.

    PATIENTS AND METHODS: Clinical data were collected from children attending a tertiary referral uveitis clinic between May 2010 and October 2012. We assigned 206 eyes of 103 children into 32 normal eyes, 108 normotensive uveitics (NU), 41 hypertensive uveitics (HU: raised IOP without glaucomatous disc), and 25 glaucomatous uveitics (GU: raised IOP with glaucomatous disc). Risk factors for raised IOP, glaucoma and steroid response (SR) were evaluated and RNFL thickness across groups was compared with determine changes related to raised IOP.

    RESULTS: IOP elevation occurred in 40 patients (38.8%) or 66/174 eyes with uveitis (37.9%); and SR occurred in 35.1% of all corticosteroid-treated eyes. Chronic uveitis was a significant risk factor for raised IOP [odds ratio (OR)=9.28, P=0.001], glaucoma, and SR (OR=8.4, P<0.001). Higher peak IOP was also a risk factor for glaucoma (OR=1.4, P=0.003). About 70% of SR eyes were high responders (IOP increase >15 mm Hg from baseline), associated with younger age and corticosteroid injections. Although no significant RNFL thinning was detected between HU and NU eyes, significant thinning was detected in the inferior quadrant of GU (121.3±28.9 μm) compared with NU eyes (142.1±32.0 μm, P=0.043).

    CONCLUSIONS: Children with chronic uveitis are at higher risk of raised IOP and glaucoma. Thinning of the inferior RNFL quadrant may suggest glaucomatous changes in uveitic children with raised IOP.

    Study site: Moorfields Eye Hospital, London
    Matched MeSH terms: Nerve Fibers/pathology*
  10. Loh KB, Ramli N, Tan LK, Roziah M, Rahmat K, Ariffin H
    Eur Radiol, 2012 Jul;22(7):1413-26.
    PMID: 22434420 DOI: 10.1007/s00330-012-2396-3
    OBJECTIVES: The degree and status of white matter myelination can be sensitively monitored using diffusion tensor imaging (DTI). This study looks at the measurement of fractional anistropy (FA) and mean diffusivity (MD) using an automated ROI with an existing DTI atlas.

    METHODS: Anatomical MRI and structural DTI were performed cross-sectionally on 26 normal children (newborn to 48 months old), using 1.5-T MRI. The automated processing pipeline was implemented to convert diffusion-weighted images into the NIfTI format. DTI-TK software was used to register the processed images to the ICBM DTI-81 atlas, while AFNI software was used for automated atlas-based volumes of interest (VOIs) and statistical value extraction.

    RESULTS: DTI exhibited consistent grey-white matter contrast. Triphasic temporal variation of the FA and MD values was noted, with FA increasing and MD decreasing rapidly early in the first 12 months. The second phase lasted 12-24 months during which the rate of FA and MD changes was reduced. After 24 months, the FA and MD values plateaued.

    CONCLUSION: DTI is a superior technique to conventional MR imaging in depicting WM maturation. The use of the automated processing pipeline provides a reliable environment for quantitative analysis of high-throughput DTI data.

    KEY POINTS: Diffusion tensor imaging outperforms conventional MRI in depicting white matter maturation. • DTI will become an important clinical tool for diagnosing paediatric neurological diseases. • DTI appears especially helpful for developmental abnormalities, tumours and white matter disease. • An automated processing pipeline assists quantitative analysis of high throughput DTI data.

    Matched MeSH terms: Nerve Fibers, Myelinated/physiology*; Nerve Fibers, Myelinated/ultrastructure*
  11. Ramli NM, Sidek S, Rahman FA, Peyman M, Zahari M, Rahmat K, et al.
    Graefes Arch Clin Exp Ophthalmol, 2014 Jun;252(6):995-1000.
    PMID: 24770532 DOI: 10.1007/s00417-014-2622-6
    PURPOSE: To measure optic nerve (ON) volume using 3 T magnetic resonance imaging (MRI), to correlate ON volume with retinal nerve fiber layer (RNFL) thickness, and to determine the viability of MRI as an objective tool in distinguishing glaucoma severity.

    METHODS: In this cross-sectional study, 30 severe glaucoma patients, 30 mild glaucoma patients and 30 age-matched controls were recruited. All subjects underwent standard automated perimetry, RNFL analysis and 3 T MRI examinations. Glaucoma patients were classified according to the Hodapp-Anderson-Parish classification. Pearson's correlation coefficient was used to correlate ON volume with RNFL, and receiver operating curve (ROC) analysis was performed to determine the sensitivity and specificity of ON volume in detecting glaucoma severity.

    RESULTS: Optic nerve volume was significantly lower in both the left and right eyes of the severe glaucoma group (168.70 ± 46.28 mm(3); 167.40 ± 45.36 mm(3)) than in the mild glaucoma group (264.03 ± 78.53 mm(3); 264.76 ± 78.88 mm(3)) and the control group (297.80 ± 71.45 mm(3); 296.56 ± 71.02 mm(3)). Moderate correlation was observed between: RNFL thickness and ON volume (r = 0.51, p <0.001), and in mean deviation of visual field and optic nerve volume (r = 0.60, p 

    Matched MeSH terms: Nerve Fibers/pathology*
  12. Tengku-Fatishah A, Nik-Ahmad-Zuky NL, Shatriah I
    Clin Ophthalmol, 2020;14:1215-1221.
    PMID: 32440087 DOI: 10.2147/OPTH.S245054
    Background: The information about macular and retinal nerve fibre layer (RNFL) thickness in women with gestational diabetes mellitus (GDM) is scarce. GDM is a risk factor for development of type 2 diabetes mellitus.

    Purpose: The purpose of this study was to evaluate mean macular and RNFL thickness in pregnant women with GDM in a teaching institution in Malaysia. We also analyzed the association of age, HbA1c level, duration of GDM, type of treatment, family history, previous history of GDM and spherical equivalent with the macular and RNFL thickness.

    Patients and Methods: This was a prospective and cross-sectional study involving 78 pregnant women with GDM, 72 healthy pregnant and 70 healthy non-pregnant women. The study was conducted in Hospital Universiti Sains Malaysia from 2016 to 2018. Macular and RNFL thickness were measured during the third trimester using spectral-domain optical coherence tomography. Age, HbA1c level, duration of GDM, type of treatment, family history, previous history of GDM and spherical equivalent were analysed.

    Results: The mean macular thickness was 236.08 (16.44) µm, 237.26 (22.42) µm and 240.66 (20.95) µm for GDM, healthy pregnant, and healthy non-pregnant women. The mean RNFL thickness was 97.27 (9.14) µm, 99.83 (12.44) µm and 97.97 (10.07) µm for GDM, healthy pregnant, and healthy non-pregnant women. There was no significant difference in the mean macular and RNFL thickness in pregnant women with GDM when compared to the control groups (p>0.05). Age, HbA1c, duration of diabetes, treatment received, history of GDM and spherical equivalent did not show significant association with mean macular and retinal thickness (p>0.05).

    Conclusion: Pregnant women with GDM have similar thickness of the macular and RNFL with the healthy pregnant and healthy non-pregnant women. Age, HbA1c, duration of diabetes, treatment received, history of GDM and spherical equivalent showed no significant association with mean macular and retinal thickness in pregnant women with GDM.

    Matched MeSH terms: Nerve Fibers
  13. Sidek S, Ramli N, Rahmat K, Ramli NM, Abdulrahman F, Kuo TL
    Eur Radiol, 2016 Dec;26(12):4404-4412.
    PMID: 26943134
    OBJECTIVE: To compare the metabolite concentration of optic radiation in glaucoma patients with that of healthy subjects using Proton Magnetic Resonance Spectroscopy (1H-MRS).

    METHODS: 1H-MRS utilising the Single-Voxel Spectroscopy (SVS) technique was performed using a 3.0Tesla MRI on 45 optic radiations (15 from healthy subjects, 15 from mild glaucoma patients, and 15 from severe glaucoma patients). A standardised Volume of Interest (VOI) of 20 × 20 × 20 mm was placed in the region of optic radiation. Mild and severe glaucoma patients were categorised based on the Hodapp-Parrish-Anderson (HPA) classification. Mean and multiple group comparisons for metabolite concentration and metabolite concentration ratio between glaucoma grades and healthy subjects were obtained using one-way ANOVA.

    RESULTS: The metabolite concentration and metabolite concentration ratio between the optic radiations of glaucoma patients and healthy subjects did not demonstrate any significant difference (p > 0.05).

    CONCLUSION: Our findings show no significant alteration of metabolite concentration associated with neurodegeneration that could be measured by single-voxel 1H-MRS in optic radiation among glaucoma patients.

    KEY POINTS: • Glaucoma disease has a neurodegenerative component. • Metabolite changes have been observed in the neurodegenerative process in the brain. • Using SVS, no metabolite changes in optic radiation were attributed to glaucoma.

    Matched MeSH terms: Nerve Fibers/metabolism; Nerve Fibers/pathology
  14. Ling KP, Mangalesh S, Tran-Viet D, Gunther R, Toth CA, Vajzovic L
    Retina, 2020 Oct;40(10):1996-2003.
    PMID: 31764609 DOI: 10.1097/IAE.0000000000002688
    BACKGROUND/PURPOSE: Using handheld spectral domain optical coherence tomography (SDOCT) imaging to investigate in vivo microanatomic retinal changes and their progression over time in young children with juvenile X-linked retinoschisis (XLRS).

    METHODS: This retrospective analysis was of handheld SD OCT images obtained under a prospective research protocol in children who had established XLRS diagnosis based on genetic testing or clinical history. Three OCT graders performed standardized qualitative and quantitative assessment of retinal volume scans, which were divided into foveal, parafoveal, and extrafoveal regions. Visual acuity data were obtained when possible.

    RESULTS: Spectral domain OCT images were available of both eyes in 8 pediatric patients with ages 7 months to 10 years. The schisis cavities involved inner nuclear layer in over 90% (15/16) of eyes in all 3 regions. Retinal nerve fiber and ganglion cell layer involvement was present only in the extrafoveal region in 63% (10/16) eyes and outer nuclear and plexiform layer in few others. In 7 children followed over 2 months to 15 months, the location of schisis remained consistent. Central foveal thickness decreased from the baseline to final available visit in 4/6 eyes. Ellipsoid zone disruption seemed to accompany lower visual acuity in 1/4 eyes.

    CONCLUSION: Early in life, the SD OCT findings in XLRS demonstrate differences in schisis location in fovea-parafoveal versus extrafoveal region, possible association between poor visual acuity and degree of ellipsoid zone disruption and decrease in central foveal thickness over time in this group. Furthermore, they illustrates that the pattern of XLRS in adults is already present in very young children, and unlike in older children and adults, those presenting with earlier disease may have a more aggressive course. Further studies in this early age group may provide more insights into treatment and prevention of progressive visual impairment in children with XLRS.

    Matched MeSH terms: Nerve Fibers/pathology
  15. Din NM, Taylor SR, Isa H, Tomkins-Netzer O, Bar A, Talat L, et al.
    JAMA Ophthalmol, 2014 Jul;132(7):859-65.
    PMID: 24789528 DOI: 10.1001/jamaophthalmol.2014.404
    IMPORTANCE: Uveitic glaucoma is among the most common causes of irreversible visual loss in uveitis. However, glaucoma detection can be obscured by inflammatory changes.

    OBJECTIVE: To determine whether retinal nerve fiber layer (RNFL) measurement can be used to detect glaucoma in uveitic eyes with elevated intraocular pressure (IOP).

    DESIGN, SETTING, AND PARTICIPANTS: Comparative case series of RNFL measurement using optical coherence tomography performed from May 1, 2010, through October 31, 2012, at a tertiary referral center. We assigned 536 eyes with uveitis (309 patients) in the following groups: normal contralateral eyes with unilateral uveitis (n = 72), normotensive uveitis (Uv-N) (n = 143), raised IOP and normal optic disc and/or visual field (Uv-H) (n = 233), and raised IOP and glaucomatous disc and/or visual field (Uv-G) (n = 88).

    EXPOSURES: Eyes with uveitis and elevated IOP (>21 mm Hg) on at least 2 occasions.

    MAIN OUTCOMES AND MEASURES: Comparison of RNFL values between groups of eyes and correlation with clinical data; risk factors for raised IOP, glaucoma, and RNFL thinning.

    RESULTS: Mean (SD) global RNFL was thicker in Uv-N (106.4 [21.4] µm) compared with control (96.0 [9.0] µm; P 

    Matched MeSH terms: Nerve Fibers/pathology*
  16. Ong Chin Feng W, Wan Hitam WH
    Taiwan J Ophthalmol, 2020 06 20;10(3):189-196.
    PMID: 33110750 DOI: 10.4103/tjo.tjo_22_20
    Purpose: Peripapillary retinal nerve fibre layer (RNFL) thickness might be useful in monitoring ongoing subclinical structural damage especially in eyes with no history of optic neuritis (ON) in neuromyelitis optica (NMO).

    Objective: To evaluate the peripapillary RNFL thickness and optic nerve functions in fellow eye of NMO with unilateral optic neuritis.

    Materials and Methods: A comparative cross-sectional study was conducted in 2 tertiary hospitals from August 2017 to May 2019. RNFL thickness and optic nerve functions were evaluated. Statistical analysis was performed using Statistical Package for Social Science version 24.

    Results: A total of 26 NMO patients and 26 controls were involved in this study. The median age (IQR) of NMO patients was 32.5 (12) years old. The RNFL thickness was significantly reduced in NMO patients with non-ON eyes as compared to control group. Best corrected visual acuity between the 2 groups were comparable (0.20 vs 0.00, p=0.071). Contrast sensitivity was also reduced in NMO patients (non-ON eyes) at all 5 spatial frequencies. In NMO group, 34.6% have normal colour vision. The mean deviation (MD) of Humphrey visual field (HVF) was higher in NMO group (p<0.001). There was a moderate correlation between RNFL thickness and contrast sensitivity. Weak correlation was found between the RNFL thickness with visual acuity and mean deviation of visual field test.

    Conclusion: Our study showed that the fellow eye of NMO patients with unilateral ON revealed a significant reduction in RNFL thickness and all the optic nerve functions have subtle early changes that signify a subclinical retinal damage.

    Matched MeSH terms: Nerve Fibers
  17. Ngoo QZ, A NF, A B, Wh WH
    Korean J Ophthalmol, 2021 06;35(3):223-230.
    PMID: 34120421 DOI: 10.3341/kjo.2020.0019
    PURPOSE: To study the retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters in obstructive sleep apnoea (OSA) patients and their relationship with severity of the disease.

    METHODS: A cross-sectional, hospital-based study. Fifty-four OSA subjects and 54 controls were recruited. Candidate that fulfil the criteria with normal ocular examinations then proceed with spectrum domain Cirrus optical coherence tomography examinations. ONH parameters and RNFL thickness were evaluated. Apnoea-hypopnoea index (AHI) of the OSA group were obtained from the medical record.

    RESULTS: In OSA, mean of average RNFL thickness was 93.87 µm, standard deviation (SD) = 9.17, p = 0.008 (p < 0.05) while superior RNFL thickness was 113.59 µm, SD = 16.29, p ≤ 0.001 (p < 0.05). RNFL thickness fairly correlate with severity of the disease (AHI), superior RNFL with R = 0.293, R2 = 0.087, p = 0.030 (p < 0.05), and nasal RNFL R = 0.292, R2 = 0.085, p = 0.032. No significant difference and correlation observed on ONH parameters. In control group, mean of average RNFL thickness was 98.96 µm, SD = 10.50, p = 0.008 (p < 0.05) while superior RNFL thickness was 125.76 µm, SD = 14.93, p ≤ 0.001 (p < 0.05).

    CONCLUSIONS: The mean of the average and superior RNFL thickness were significantly lower in the OSA group compare to control. Regression analysis showed RNFL thickness having significantly linear relationship with the AHI, specifically involving the superior and nasal quadrant.

    Matched MeSH terms: Nerve Fibers
  18. Michael NDB, Hussein A, Abd Halim S, Ab Hamid SA
    Cureus, 2019 May 04;11(5):e4599.
    PMID: 31309023 DOI: 10.7759/cureus.4599
    Background Neurovascular changes occur during the migraine is believed to cause alteration in cerebral and retinal circulation that possible result in damage to the brain and even retina or optic nerve. Retinal nerve fiber layer (RNFL) thickness measurement can be used as an index to assess ganglion cell and retinal nerve fiber damages. The aim of this study was to evaluate the optic nerve head (ONH) parameters, RNFL thickness, and ocular perfusion pressure (OPP) in migraine patients. Methods This was a cross-sectional study, conducted in Hospital Universiti Sains Malaysia, Kelantan from July 2016 to November 2018, involving patients with a confirmed diagnosis of migraine and controls. Ninety-four eyes of 47 migraine patients and 94 eyes of 47 healthy subjects were included in this study. Blood pressure and intraocular pressure were measured and OPP was calculated. ONH parameters and RNFL thickness were measured using optical coherence tomography (OCT) after pupillary dilatation. Statistical analysis was done using Statistical Package for the Social Science (SPSS Inc Version 24). Results With respect to all means values of ONH parameters, there was no statistically significant difference between migraine patients and controls. For RNFL, there were significant reductions in average and superior RNFL thickness on both eyes with adjustment of age and gender (P-value: right eye (RE) average = 0.027; RE superior = 0.034; left eye (LE) average = 0.037; LE superior = 0.031). In view of OPP, there was no significant difference between migraine patients and controls (P-value = 0.172). Weak correlations were found between the ONH parameters and RNFL thickness with OPP, respectively, in migraine patients. Conclusion This study showed no difference in ONH parameters between migraine patients and healthy subjects. There was significant thinning in average and superior RNFL for migraine patients. No difference found in OPP between both groups. ONH parameters and RNFL thickness had a weak correlation with OPP in migraine patients.
    Matched MeSH terms: Nerve Fibers
  19. Mohd-Ilham I, Tai ELM, Suhaimi H, Shatriah I
    Korean J Ophthalmol, 2021 08;35(4):287-294.
    PMID: 34162187 DOI: 10.3341/kjo.2020.0106
    PURPOSE: There are limited data from Asian countries regarding retinal thickness in children with type 1 diabetes mellitus (T1DM). This study aimed to compare the macular and retinal nerve fiber layer (RNFL) parameters between diabetic children without retinopathy and non-diabetic healthy children. We also evaluated the factors associated with RNFL thickness in children with T1DM.

    METHODS: A comparative cross-sectional study was conducted among children with T1DM and healthy children aged 7 to 17 years old in Hospital Universiti Sains Malaysia from 2017 to 2019. Children with retinal disease or glaucoma were excluded. Macular and RNFL thicknesses were measured using spectral-domain optical coherence tomography. Demographic information, duration of diabetes, blood pressure, body mass index, visual acuity, and retinal examination findings were documented. Glycosylated hemoglobin levels, renal function, and blood lipid levels were also collected.

    RESULTS: Forty-one children with T1DM and 80 age- and sex-matched children were enrolled. Both sexes were affected. Mean duration of diabetes mellitus was 3.66 years. The mean glycated hemoglobin levels in the T1DM group was 9.99%. The mean macular and RNFL thicknesses in children with T1DM were 277.56 (15.82) µm and 98.85 (12.05) µm, respectively. Children with T1DM had a significantly thinner average macula, superior outer macula, nasal outer macula, mean RNFL, and inferior RNFL thickness compared to controls (p < 0.05). There was a significant association between nephropathy and the mean RNFL thickness.

    CONCLUSIONS: Children with T1DM had significantly decreased mean macular and RNFL thicknesses. Nephropathy is associated with an increased RNFL thickness.

    Matched MeSH terms: Nerve Fibers
  20. Ramli K, Gasim AI, Ahmad AA, Htwe O, Mohamed Haflah NH, Law ZK, et al.
    Tissue Eng Part A, 2019 10;25(19-20):1438-1455.
    PMID: 30848172 DOI: 10.1089/ten.TEA.2018.0279
    We investigated the efficacy of a muscle-stuffed vein (MSV) seeded with neural-transdifferentiated human mesenchymal stem cells as an alternative nerve conduit to repair a 15-mm sciatic nerve defect in athymic rats. Other rats received MSV conduit alone, commercial polyglycolic acid conduit (Neurotube®), reverse autograft, or were left untreated. Motor and sensory functions as well as nerve conductivity were evaluated for 12 weeks, after which the grafts were harvested for histological analyses. All rats in the treatment groups demonstrated a progressive increase in the mean Sciatic Functional Index (motor function) and nerve conduction amplitude (electrophysiological function) and showed positive withdrawal reflex (sensory function) by the 10th week of postimplantation. Autotomy, which is associated with neuropathic pain, was severe in rats treated with conduit without cells; there was mild or no autotomy in the rats of other groups. Histologically, harvested grafts from all except the untreated groups exhibited axonal regeneration with the presence of mature myelinated axons. In conclusion, treatment with MSV conduit is comparable to that of other treatment groups in supporting functional recovery following sciatic nerve injury; and the addition of cells in the conduit alleviates neuropathic pain. Impact Statement It is shown that pretreated muscle-stuffed vein conduit is comparable to that of commercial nerve conduit and autograft in supporting functional recovery following peripheral nerve injury. The addition of neural-differentiated mesenchymal stem cells in the conduit is shown to alleviate neuropathic pain.
    Matched MeSH terms: Nerve Fibers/metabolism; Nerve Fibers/ultrastructure
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links