Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Siar CH, Toh CG, Romanos G, Swaminathan D, Ong AH, Yaacob H, et al.
    J. Periodontol., 2003 May;74(5):571-8.
    PMID: 12816287
    Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the soft tissues around immediately loaded implants placed in the macaque posterior mandible.
    Matched MeSH terms: Osseointegration
  2. Merican AM, Randle R
    J Arthroplasty, 2006 Sep;21(6):846-51.
    PMID: 16950037
    The Fitmore titanium mesh cementless acetabular component in 115 hip arthroplasties was reviewed at an average of 33 months of follow-up. None were revised nor had infection. One hip dislocated 4 years postoperatively. Two femoral components were revised. The average Harris Hip Score at the last follow-up was 90 points. In the 96 sets of radiographs available, there was no loosening or new radiolucency. One hip had nonprogressive osteolysis adjacent to a screw. This press-fit cup has its polar region flattened and is rim loading. Noncontact (gaps) at the acetabular floor is expected and is not critical for fixation. In all but 6 hips, these gaps filled. In 5 hips, a minimal gap (
    Matched MeSH terms: Osseointegration
  3. Rosdan S, Al-Salihi KA, Suzina AH, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:111-2.
    PMID: 15468843
    The main objective of the study was to determine the biodegradability, resorption and osteoconductivity potency of coral implant. Coral blocks (CORAGRAF) were prepared from sea coral Porites species. The blocks were implanted in the right mandible of rabbit model. Implants were harvested at 2 and 4 weeks intervals and subjected for light and scanning electron microscopy. Dense hydroxyapatite (DHA) was implanted in the left mandible as a control. The results of this study demonstrated that CORAGRAF is a good implant material that can accelerates bone healing and be resorbed in an acceptable time. The mechanisms of the resorption seemed to be the same (crumbling process), a first step where the edge of the coral become powdery then a second step which could be phagocytosis and dissolution in extracellular fluid.
    Matched MeSH terms: Osseointegration
  4. Sghaireen MG, Alduraywish AA, Srivastava KC, Shrivastava D, Patil SR, Al Habib S, et al.
    PMID: 32708165 DOI: 10.3390/ijerph17145253
    Diabetes mellitus is known to compromise the various aspects of homeostasis, including the immune response and the composition of oral microflora. One of the oral manifestations of diabetes mellitus is tooth loss and the survival rate of dental implants chosen as a treatment modality for its rehabilitation is controversial. The current study aims to evaluate and compare the failure rate of dental implants between well-controlled diabetic and healthy patients. A retrospective study of case-control design was conceptualized with 121 well-controlled diabetic and 136 healthy individuals. Records of subjects who had undergone oral rehabilitation with dental implants between the periods of January 2013 to January 2016 were retrieved. Post-operative evaluation was carried out for all patients for about three years to assess the immediate and long-term success of the procedure. From a total of 742 dental implants, 377 were placed in well-controlled diabetic patients (case group) and 365 in healthy subjects (control group). A comparable (9.81%), but non-significant (p = 0.422) failure rate was found in the case group in comparison to the control group (9.04%). A non-significant (p = 0.392) raised number (4.98%) of failure cases were reported among females in comparison to males (4.44%). In respect to arch, the mandibular posterior region was reported as the highest failure cases (3.09%; p = 0.411), with 2.29% of cases reported in the mandibular anterior (p = 0.430) and maxillary posterior (p = 0.983) each. The maxillary anterior region was found to have the least number (1.75%; p = 0.999) of failure cases. More (4.98%; p = 0.361) cases were reported to fail during the functional loading stage in contrast to osseointegration (4.44%; p = 0.365). A well-controlled diabetic status does not impose any additional risk for individuals undergoing dental implant therapy.
    Matched MeSH terms: Osseointegration
  5. Mazita A, Fazlina WH, Abdullah A, Goh BS, Saim L
    Singapore Med J, 2009 Nov;50(11):1072-6.
    PMID: 19960162
    The purpose of this study was to review the results of our patients with congenital canal atresia after implantation of bone-anchored hearing aids (BAHA). The occurrence of complications was also reviewed.
    Matched MeSH terms: Osseointegration
  6. Asma A, Ubaidah MA, Hasan SS, Wan Fazlina WH, Lim BY, Saim L, et al.
    PMID: 24427576 DOI: 10.1007/s12070-013-0621-2
    Bone anchored hearing aid (Baha) implant is an option for patient with canal atresia, single sided deafness(SSD) and chronically discharging ears despite treatments. This retrospective study was conducted from 2001 to 2011 to evaluate the surgical outcome of Baha implant surgery. Thirty-three patients were identified during this study period. Their age at implantation ranged from 5 to 40 years. Of 33 patients, 29 (87.9 %) patients had bilateral microtia and canal atresia, 3 (9.1 %) patients had unilateral microtia and canal atresia and 1 (3.0 %) patients have SSD following labyrinthitis. One patient (3.2 %) had major complication which is lost of implant due to failure of osseointegration. Soft tissue reactions were seen 7 patients (21.1 %). Of these 7 patients, 4 patients required 3-4 procedures as day care operation for excision of the skin overgrowth surrounding the abutment. Recurrent antibiotic treatment was required in 3 patients (9.7 %). None of our patient had history of intraoperative or peri-operative complication following Baha surgery. The commonest complications are local infection and inflammation at the implant site. None of our patient had history of intraoperative or peri-operative complication following Baha implant surgery.
    Matched MeSH terms: Osseointegration
  7. Al-Juboori MJ, AbdulRahaman SB, Hassan A
    Implant Dent, 2013 Aug;22(4):351-5.
    PMID: 23811720 DOI: 10.1097/ID.0b013e318296583d
    To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA).
    Matched MeSH terms: Osseointegration/physiology*
  8. Sritharan S, Kannan TP, Norazmi MN, Nurul AA
    J Craniomaxillofac Surg, 2018 Aug;46(8):1361-1367.
    PMID: 29805067 DOI: 10.1016/j.jcms.2018.05.002
    OBJECTIVE: In this study, we evaluated the potential role of IL-6 and/or IL-17A in regulating the OPG/RANKL (osteoprotegerin/receptor activator of nuclear factor kappa b ligand) system of murine osteoblast cell line (MC3T3-E1) cultured on hydroxyapatite (HA).

    METHODS: MC3T3-E1 cells were seeded on HA and treated with recombinant IL-6 or rIL-17A or combination of the two cytokines. Cell proliferation and differentiation activity were measured by MTS and alkaline phosphatase assays respectively. Observation of cell adhesion and proliferation was examined by scanning electron microscopy. Gene and protein expressions were performed on RANKL and OPG using qPCR, Western blot and ELISA.

    RESULTS: We demonstrated that treatment with recombinant IL-17A (rIL-17A) and the combination rIL-6/rIL-17A promoted better adhesion and higher proliferation of cells on HA. Cells treated with rIL-17A and the combination cytokines showed a significant increase in differentiation activity on day 7, 10 and 14 as indicated by ALP activity (p 

    Matched MeSH terms: Osseointegration/drug effects
  9. Mohammadi H, Sepantafar M
    Iran Biomed J, 2016 Sep;20(4):189-200.
    PMID: 26979401
    Titanium and its alloy are known as important load-bearing biomaterials. The major drawbacks of these metals are fibrous formation and low corrosion rate after implantation. The surface modification of biomedical implants through various methods such as plasma spray improves their osseointegration and clinical lifetime. Different materials have been already used as coatings on biomedical implant, including calcium phosphates and bioglass. However, these materials have been reported to have limited clinical success. The excellent bioactivity of calcium silicate (Ca-Si) has been also regarded as coating material. However, their high degradation rate and low mechanical strength limit their further coating application. Trace element modification of (Ca-Si) bioceramics is a promising method, which improves their mechanical strength and chemical stability. In this review, the potential of trace element-modified silicate coatings on better bone formation of titanium implant is investigated.
    Matched MeSH terms: Osseointegration/physiology*
  10. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Mohd Noor A
    Biomed Res Int, 2014;2014:692328.
    PMID: 25025068 DOI: 10.1155/2014/692328
    A morphology study was essential to the development of the cementless femoral stem because accurate dimensions for both the periosteal and endosteal canal ensure primary fixation stability for the stem, bone interface, and prevent stress shielding at the calcar region. This paper focused on a three-dimensional femoral model for Asian patients that applied preoperative planning and femoral stem design. We measured various femoral parameters such as the femoral head offset, collodiaphyseal angle, bowing angle, anteversion, and medullary canal diameters from the osteotomy level to 150 mm below the osteotomy level to determine the position of the isthmus. Other indices and ratios for the endosteal canal, metaphyseal, and flares were computed and examined. The results showed that Asian femurs are smaller than Western femurs, except in the metaphyseal region. The canal flare index (CFI) was poorly correlated (r < 0.50) to the metaphyseal canal flare index (MCFI), but correlated well (r = 0.66) with the corticomedullary index (CMI). The diversity of the femoral size, particularly in the metaphyseal region, allows for proper femoral stem design for Asian patients, improves osseointegration, and prolongs the life of the implant.
    Matched MeSH terms: Osseointegration*
  11. Younis L, Taher A, Abu-Hassan MI, Tin O
    J Contemp Dent Pract, 2009;10(4):35-42.
    PMID: 19575052
    The purpose of this study was to compare bone healing and coronal bone remodeling following both immediate and delayed placement of titanium dental implants in extraction sockets.
    Matched MeSH terms: Osseointegration*
  12. Phang MY, Ng MH, Tan KK, Aminuddin BS, Ruszymah BH, Fauziah O
    Med J Malaysia, 2004 May;59 Suppl B:198-9.
    PMID: 15468886
    Tricalcium phosphate/hydroxyapatite (TCP/HA), hydroxyapatite (HA), chitosan and calcium sulphate (CaSO4) were studied and evaluated for possible bone tissue engineered construct acting as good support for osteogenic cells to proliferate, differentiate, and eventually spread and integrate into the scaffold. Surface morphology visualized by SEM showed that scaffold materials with additional fibrin had more cell densities attached than those without, depicting that the presence of fibrin and collagen fibers were truly a favourite choice of cells to attach. In comparison of various biomaterials used incorporated with fibrin, TCP/HA had the most cluster of cells attached.
    Matched MeSH terms: Osseointegration/physiology
  13. Al-Salihi KA, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:202-3.
    PMID: 15468888
    In this study the surface properties of two particulate coral and polyhydroxybutrate (PHB) were studied in order to characterize them prior to use in composite production. Coral powder and PHB particle were evaluated using scanning electron microscopy and confocal laser scanning microscopy, to measure surface porosity and pores size. The results showed that coral powder has multiple pleomorphic micropores cross each others give appearance of micro-interconnectivity. Some pore reached to 18 microm with an average porosity of 70%. PHB revealed multiple different size pores extended to the depth, with an average some times reach 25 microm and porosity 45%. These findings demonstrate that both coral and PHB have excellent pores size and porosity that facilitate bone in growth, vascular invasion and bone development. We believe that incorporation of coral powder into PHB will make an excellent composite scaffold for tissue engineering.
    Matched MeSH terms: Osseointegration/physiology
  14. Kokubo T
    Med J Malaysia, 2004 May;59 Suppl B:91-2.
    PMID: 15468833
    Metallic materials implanted into bone defects are generally encapsulated by a fibrous tissue. Some metallic materials such as titanium and tantalum, however, have been revealed to bond to the living bone without forming the fibrous tissue, when they were subjected to NaOH solution and heat treatments. Thus treated metals form bone tissue around them even in muscle, when they take a porous form. This kind of osteoconductive and osteoinductive properties are attributed to sodium titanate or tantalate layer on their surfaces formed by the NaOH and heat treatments. These layers induce the deposition of bonelike apatite on the surface of the metals in the living body. This kind of bioactive metals are useful as bone substitutes even highly loaded portions, such as hip joint, spine and tooth root.
    Matched MeSH terms: Osseointegration/physiology*
  15. Ueda M
    Med J Malaysia, 2004 May;59 Suppl B:29.
    PMID: 15468803
    Matched MeSH terms: Osseointegration/physiology
  16. Rahman SA, Muhammad H, Haque S, Alam MK
    J Contemp Dent Pract, 2019 Feb 01;20(2):173-178.
    PMID: 31058631
    AIM: The aim of this study was to evaluate the changes in the peri-implant hard and soft tissues and implant stability and to assess the correlation of bone loss and peri-implant probing depth with implant stability.

    MATERIALS AND METHODS: Twenty-one patients with implants were included in this study and implants were assessed by resonance frequency analysis (RFA). Bone levels of the implants were assessed by measuring mesial and distal bone levels from the periapical radiograph, and soft tissue was assessed from probing depth using a periodontal probe. Implants were assessed for stability and probing depth at pre-loading, at 3 months and 6 months post-loading. RFA and probing depth were statistically compared from different time points. Correlation of probing depth and marginal bone loss with implant stability was also determined.

    RESULTS: The average change in implant stability quotient (ISQ) measurements from pre-loading to 6 months post-loading was found to be statistically significant (p <0.005). The average probing depth reduced from 1.767 mm at pre-loading to 1.671 mm at post-loading 3 months, and 1.600 mm at post-loading 6 months. At 6 months of function, radiographic examination yielded 0.786 mm mesial bone loss and 0.8 mm distal bone loss. It was found to be statistically significant (p <0.005) but within an acceptable range. No significant correlation was found between implant stability and bone loss; and implant stability and probing depth.

    CONCLUSION: The study revealed an increasing trend in implant stability values with the time that indicates successful osseointegration. Increasing mean values for mesial and distal bone loss were also found.

    CLINICAL SIGNIFICANCE: The success of dental implants is highly dependent on the quality of bone and implant-bone interface, i.e., osseointegration. The most important factors that influence the survival rate of an implant is initial stability. The present study found the changes in the peri-implant hard and soft tissues and implant stability. This article, while being a prospective study, may show the evidence of successful osseointegration by increasing trend in implant stability (RFA) values with time which can help to the clinician in the long-term management of implants.

    Matched MeSH terms: Osseointegration
  17. Shaminea S, Kannan TP, Norazmi MN, Nurul AA
    MyJurnal
    Introduction: Cytokines have been gaining great focus due to their role in enhancing osseointegration as well as their potential in bone reconstruction. Osseointegration often faces complications in its compatibility with the implant due to rejection by the recipients own immune system. Therefore, extensive studies are being carried out to enhance osteoblast development to minimize such complication. The aim of this study was to determine the effect of different concentrations of Interleukin 6 (IL-6) and Interleukin 17a (IL-17A) in the proliferation and differentiation of murine and human osteoblasts.

    Methods: Various concentrations (5, 10, 25 and 50 ng/ml) of rIL-6 and rIL-17A were tested on both murine osteoblast (MC3T3-E1) and human feotal osteoblast (hFOB) cell lines using [3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium] (MTS) and alkaline phosphatise (ALP) assays. MTS was carried out at 24, 48, 72, 96 and 120 hours while ALP assay was done on day 1, 3, 7, 10 and 14.

    Results: MC3T3-E1 cells showed steadier proliferation and differentiation compared to hFOB. Both cell lines expressed responses in dose-dependent manner. The concentration of 10ng for IL-6 and IL-17A in the case of MC3T3-E1 cell line was found to be the most suitable for further studies.

    Conclusion: IL-6 and IL-17A enhance proliferation and ALP activity of both MC3T3-E1 and hFOB cell lines.
    Matched MeSH terms: Osseointegration
  18. Akram Hassan, Swaminathan D
    Hydroxyapatite (HA) used for bone replacement is one of the most active areas of ceramic biomaterials research currently. It has been used clinically for the last 20 years due to its excellent biocompatibility, osseoconduction and osseointegration. Many modifications have been done to develop a stronger, tougher and biocompatible ceramic biomaterial because pure HA is brittle. Researchers in Universiti Sains Malaysia had developed this value added HA that is stronger and less brittle compared to pure HA. The objective of this in vitro study was to evaluate the genotoxic characteristic of the value added HA based material by using Bacterial Reverse Mutation Assay (Ames test). The Bacterial Reverse Mutation Assay of HA was performed on Salmonella typhimurium strains TA98, TA100, TA1535, TA1537 and Escherichia coli strain WP2 uvrA using the preincubation method in the presence and absence of an exogenous metabolic activation system. All the bacterial tester strains treated with and without S9 Mix showed no increase of revertant colonies with increase in concentration of test substance for both the dose finding test and the main test. The number of revertant colonies was less than twice that of the solvent control for all the five bacterial strains and this was reproducible for both the dose finding test and the main test. The numbers of revertant colonies in the negative and positive controls were within the background data of our laboratory. In conclusion the results of the tests showed that the value added HA was considered to have no reverse mutagenic potential under the present test conditions.
    Matched MeSH terms: Osseointegration
  19. Shan L, Kadhum AAH, Al-Furjan MSH, Weng W, Gong Y, Cheng K, et al.
    Materials (Basel), 2019 Mar 10;12(5).
    PMID: 30857349 DOI: 10.3390/ma12050815
    It is well known that three-dimensional (3D) printing is an emerging technology used to produce customized implants and surface characteristics of implants, strongly deciding their osseointegration ability. In this study, Ti alloy microspheres were printed under selected rational printing parameters in order to tailor the surface micro-characteristics of the printed implants during additive manufacturing by an in situ, controlled way. The laser path and hatching space were responsible for the appearance of the stripy structure (S), while the bulbous structure (B) and bulbous⁻stripy composite surface (BS) were determined by contour scanning. A nano-sized structure could be superposed by hydrothermal treatment. The cytocompatibility was evaluated by culturing Mouse calvaria-derived preosteoblastic cells (MC3T3-E1). The results showed that three typical microstructured surfaces, S, B, and BS, could be achieved by varying the 3D printing parameters. Moreover, the osteogenic differentiation potential of the S, B, and BS surfaces could be significantly enhanced, and the addition of nano-sized structures could be further improved. The BS surface with nano-sized structure demonstrated the optimum osteogenic differentiation potential. The present research demonstrated an in situ, controlled way to tailor and optimize the surface structures in micro-size during the 3D printing process for an implant with higher osseointegration ability.
    Matched MeSH terms: Osseointegration
  20. Fadilah A, Zuki AB, Loqman MY, Zamri-Saad M, Norimah Y, Asnah H
    Med J Malaysia, 2004 May;59 Suppl B:178-9.
    PMID: 15468876
    The study was carried out to evaluate macroscopically the ability of coral to repair a large size bone defect. A total 12 adult, male sheep were used in the study. The large bone defect (2.5cm x 0.5cm x 0.5cm) was created surgically on the left proximal femur and replaced by a block of coral (Porites sp.). Radiographs were obtained immediately after surgery and at 2, 4, 8 and 12 weeks post-implantation. Ultrasonographic examinations were carried out every 2 weeks after implantation up to 12 weeks using ultrasound machine (TOSHIBA Capasee II) connected with 7MHz frequency transducer. The sheep were euthanased at 2, 4, 8, and 12 weeks post-implantation and the bone examined grossly. Both ultrasonographs and radiographs taken at 8 and 12 weeks showed that the implants had been resorbed and left the space that much reduced in size. There was no sign of implant rejection observed in all animals. The results showed that processed coral has potential to become bone substitute for reconstructive bone surgery.
    Matched MeSH terms: Osseointegration/physiology*