Displaying publications 1 - 20 of 95 in total

Abstract:
Sort:
  1. de Carvalho LP, Fong A, Troughton R, Yan BP, Chin CT, Poh SC, et al.
    Thromb. Haemost., 2018 02;118(2):415-426.
    PMID: 29443374 DOI: 10.1160/TH17-08-0564
    Studies on platelet reactivity (PR) testing commonly test PR only after percutaneous coronary intervention (PCI) has been performed. There are few data on pre- and post-PCI testing. Data on simultaneous testing of aspirin and adenosine diphosphate antagonist response are conflicting. We investigated the prognostic value of combined serial assessments of high on-aspirin PR (HASPR) and high on-adenosine diphosphate receptor antagonist PR (HADPR) in patients with acute coronary syndrome (ACS). HASPR and HADPR were assessed in 928 ACS patients before (initial test) and 24 hours after (final test) coronary angiography, with or without revascularization. Patients with HASPR on the initial test, compared with those without, had significantly higher intraprocedural thrombotic events (IPTE) (8.6 vs. 1.2%, p ≤ 0.001) and higher 30-day major adverse cardiovascular and cerebrovascular events (MACCE; 5.2 vs. 2.3%, p = 0.05), but not 12-month MACCE (13.0 vs. 15.1%, p = 0.50). Patients with initial HADPR, compared with those without, had significantly higher IPTE (4.4 vs. 0.9%, p = 0.004), but not 30-day (3.5 vs. 2.3%, p = 0.32) or 12-month MACCE (14.0 vs. 12.5%, p = 0.54). The c-statistic of the Global Registry of Acute Coronary Events (GRACE) score alone, GRACE score + ASPR test and GRACE score + ADPR test for discriminating 30-day MACCE was 0.649, 0.803 and 0.757, respectively. Final ADPR was associated with 30-day MACCE among patients with intermediate-to-high GRACE score (adjusted odds ratio [OR]: 4.50, 95% confidence interval [CI]: 1.14-17.66), but not low GRACE score (adjusted OR: 1.19, 95% CI: 0.13-10.79). In conclusion, both HASPR and HADPR predict ischaemic events in ACS. This predictive utility is time-dependent and risk-dependent.
    Matched MeSH terms: Coronary Angiography
  2. Yun KE, Chang Y, Rampal S, Zhang Y, Cho J, Jung HS, et al.
    J Clin Gastroenterol, 2018 07;52(6):508-514.
    PMID: 28471937 DOI: 10.1097/MCG.0000000000000824
    GOALS: Because of shared risk factors between clinically manifest cardiovascular disease and colorectal cancer, we hypothesized the coexistence of subclinical atherosclerosis measured by coronary artery calcium (CAC) and colorectal adenoma (CRA) and that these 2 processes would also share common risk factors.

    BACKGROUND: No study has directly compared the risk factors associated with subclinical coronary atherosclerosis and CRA.

    STUDY: This was a cross-sectional study using multinomial logistic regression analysis of 4859 adults who participated in a health screening examination (2010 to 2011; analysis 2014 to 2015). CAC scores were categorized as 0, 1 to 100, or >100. Colonoscopy results were categorized as absent, low-risk, or high-risk CRA.

    RESULTS: The prevalence of CAC>0, CAC 1 to 100 and >100 was 13.0%, 11.0%, and 2.0%, respectively. The prevalence of any CRA, low-risk CRA, and high-risk CRA was 15.1%, 13.0%, and 2.1%, respectively. The adjusted odds ratios (95% confidence interval) for CAC>0 comparing participants with low-risk and high-risk CRA with those without any CRA were 1.35 (1.06-1.71) and 2.09 (1.29-3.39), respectively. Similarly, the adjusted odds ratios (95% confidence interval) for any CRA comparing participants with CAC 1 to 100 and CAC>100 with those with no CAC were 1.26 (1.00-1.6) and 2.07 (1.31-3.26), respectively. Age, smoking, diabetes, and family history of CRC were significantly associated with both conditions.

    CONCLUSIONS: We observed a graded association between CAC and CRA in apparently healthy individuals. The coexistence of both conditions further emphasizes the need for more evidence of comprehensive approaches to screening and the need to consider the impact of the high risk of coexisting disease in individuals with CAC or CRA, instead of piecemeal approaches restricted to the detection of each disease independently.

    Matched MeSH terms: Coronary Angiography/methods
  3. Ying CK, Kandaiya S
    J Radiol Prot, 2010 Sep;30(3):585-96.
    PMID: 20826892 DOI: 10.1088/0952-4746/30/3/012
    Interventional cardiology (IC) procedures are known to give high radiation doses to patients and cardiologists as they involve long fluoroscopy times and several cine runs. Patients' dose measurements were carried out at the cardiology department in a local hospital in Penang, Malaysia, using Gafchromic XR-RV2 films. The dosimetric properties of the Gafchromic film were first characterised. The film was energy and dose rate independent but dose dependent for the clinically used values. The film had reproducibility within ± 3% when irradiated on three different days and hence the same XR-RV2 dose-response calibration curve can be used to obtain patient entrance skin dose on different days. The increase in the response of the film post-irradiation was less than 4% over a period of 35 days. For patient dose measurements, the films were placed on the table underneath the patient for an under-couch tube position. This study included a total of 44 patients. Values of 35-2442 mGy for peak skin dose (PSD) and 10.9-344.4 Gy cm(2) for dose-area product (DAP) were obtained. DAP was found to be a poor indicator of PSD for PTCA procedures but there was a better correlation (R(2) = 0.7344) for CA + PTCA procedures. The highest PSD value in this study exceeded the threshold dose value of 2 Gy for early transient skin injury recommended by the Food and Drug Administration.
    Matched MeSH terms: Coronary Angiography*
  4. Ying C, Kandaiya S
    Sains Malaysiana, 2012;41:133-140.
    Patient skin dose measurements were performed at the cardiology department in a hospital in Penang, Malaysia using EDR films during coronary angiography (CA) procedures. The EDR2 film was first characterized in terms of dose and energy dependence as well reproducibility. For patient dose measurements, the films were placed on the table underneath the patient for an under couch tube position. A total of 27 CA procedures were studied. Results for peak skin doses (PSD) ranged from 35 to 684 mGy while the dose area product (DAP) values were from 5.5 to 93.1 Gy cm2. DAP correlated reasonably with PSD for CA procedure (R2= 0.8212). The highest PSD value in this study is below the threshold dose value of 2 Gy for early transient skin injury recommended by the Food and Drug Administration (FDA 1994).
    Matched MeSH terms: Coronary Angiography
  5. Yap LB, Choy CN, Koh KW, Kannan P, Jeyamalar R, Navin S, et al.
    Med J Malaysia, 2023 Mar;78(2):139-144.
    PMID: 36988521
    INTRODUCTION: Intravascular ultrasound (IVUS) is recommended in the use of left main stem (LMS) percutaneous coronary intervention (PCI). Since the LMS diameter is usually larger than other coronary arteries, a new generation everolimus drug-eluting stent (DES), Synergy Megatron DES (Boston Scientific) has better axial and radial strength allowing more post implant overexpansion and consequently better suited for LMS lesions. We performed a study to evaluate the clinical outcomes of PCI using 1) an improved IVUS protocol with optimisation targets and 2) the use of Megatron stents.

    MATERIALS AND METHODS: This was a study involving LMS PCI coronary lesions using the Synergy Megatron DES. An IVUS protocol using predefined optimisation targets to evaluate for stent malapposition, longitudinal stent deformation, optimal stent expansion >90% of reference lumen and appropriate distal landing zone was used in all cases. The primary end-point was procedural success, defined by successful stent implantation with <30% residual stenosis. The secondary end-point was in-hospital and 30-day major adverse cardiovascular event (MACE).

    RESULTS: Eight patients with significant LMS stenosis were successfully treated with the Megatron stent. The primary end-point was achieved in all patients. There were no cases of stent malapposition or longitudinal stent deformation, one case did not have optimal LMS stent expansion and one case did not have an appropriate distal landing zone. IVUS optimisation criteria were met in 6 (75%) cases. There were no complications of coronary dissection, slow or no reflow, stent thrombosis or vessel perforation. None of the patients suffered in-hospital or 30-day MACE. The average LMS MLD at baseline was 2.1 ± 0.1mm and the post-PCI LMS MLD was 4.0 ± 0.5mm, with a significant acute luminal gain of 1.9 ± 0.7mm (p<0.01). A post-PCI MSA of 17 ± 3.9 mm2 was numerically superior compared to those documented in other LMS PCI trials.

    CONCLUSION: This study demonstrates low rates of shortterm major adverse cardiovascular events among patients with LMS PCI using the Megatron stents. It highlights the usefulness of IVUS-guided optimisation in LMS PCI. With the use of intravascular imaging, the new generation stent technology can improve the treatment of large proximal vessels and PCI of LMS lesions.

    Matched MeSH terms: Coronary Angiography
  6. Xie CB, Chan MY, Teo SG, Low AF, Tan HC, Lee CH
    Singapore Med J, 2011 Nov;52(11):835-9.
    PMID: 22173254
    There is a paucity of data on acute myocardial infarction (AMI) in young Asian women and of comparative data among various ethnic groups with respect to risk factor profile and clinical outcomes. We present a comprehensive overview of the clinical characteristics of young Asian women with AMI and a comparative analysis among Chinese, Malay and Indian women in a multi-ethnic Asian country.
    Matched MeSH terms: Coronary Angiography/methods
  7. Wong A, Shahboden M, Pauzi W, Ibrahim W
    Pediatr Cardiol, 2007 Jan-Feb;28(1):74-5.
    PMID: 17318711 DOI: 10.1007/s00246-006-1398-9
    Matched MeSH terms: Coronary Angiography
  8. Wickramatilake CM, Mohideen MR, Pathirana C
    Indian Heart J, 2017 02 12;69(2):291.
    PMID: 28460787 DOI: 10.1016/j.ihj.2017.02.002
    Matched MeSH terms: Coronary Angiography
  9. Wang TK, Oh TH, Samaranayake CB, Webster MW, Stewart JT, Watson T, et al.
    Int J Clin Pract, 2015 Dec;69(12):1465-72.
    PMID: 26304046 DOI: 10.1111/ijcp.12723
    Coronary angiography is the gold standard for assessing coronary artery disease (CAD). In many patients with chest pain, no or mild CAD (< 50% stenosis) is found. It is uncertain whether this 'non-significant' result influences management and outcomes. We reviewed characteristics and outcomes in a contemporary cohort of chest pain referrals who had mild or absent CAD on coronary angiography.
    Matched MeSH terms: Coronary Angiography
  10. Vu H, Khanh Tuong TT, Hoang Lan N, Quoc Thang T, Bilgin K, Hoa T, et al.
    Clin Ter, 2022 11 15;173(6):565-571.
    PMID: 36373456 DOI: 10.7417/CT.2022.2483
    Background: Various non-invasive methods have been studied for assessing the severity of fatty liver disease and coronary atherosclero-sis. However, the correlation between hepatic steatosis and coronary atherosclerosis has not been fully studied, either globally or specifically in Vietnam. This study investigated the association between nonalcoholic fatty liver disease (NAFLD) and coronary atherosclerosis using coronary computed tomography angiography (CCTA).

    Methods: An analytical cross-sectional study was performed, including 223 patients treated by the Cardiology Department, the Emergency Interventional Cardiology Departments, and the Internal Cardiology Clinic of Thong Nhat Hospital.

    Results: In our cohort of 223 patients, the NAFLD was detected in 66% of the population, the mean coronary artery stenosis (CAS) was 44.54% ± 20.23%, and the mean coronary artery calcium score (CACS) was 3569.05 ± 425.99, as assessed using the Agatston method. The proportion of patients with significant atherosclerotic plaque (CAS 50%) >was 32%, whereas the remaining 68% had insignificant stenosis. Among our study population, 16% had no coronary artery calcification, 38% had mild calcification, and 46% had moderate to severe calcification. In the group of NAFLD patients, 33.3% had significant atherosclerotic plaque, which was not significantly different from the rate in individuals without NAFLD (p = 0.51). Mild coronary artery calcification was detected in 37.4% of NAFLD patients, and moderate to severe calcification was detected in 48.3% (p = 0.45).

    Conclusions: NAFLD was not found to be strongly associated with coronary atherosclerosis in this study. More studies with larger sample sizes remain necessary to verify whether any correlation exists.

    Matched MeSH terms: Coronary Angiography/methods
  11. Tenekecioglu E, Serruys PW, Onuma Y, Costa R, Chamié D, Sotomi Y, et al.
    JACC Cardiovasc Interv, 2017 06 12;10(11):1115-1130.
    PMID: 28527768 DOI: 10.1016/j.jcin.2017.03.015
    OBJECTIVES: The primary objective of this study was to evaluate the safety and effectiveness of the Mirage (Manli Cardiology, Singapore) bioresorbable microfiber sirolimus-eluting scaffold compared with the Absorb (Abbott Vascular, Santa Clara, California) bioresorbable vascular scaffold in the treatment of stenotic target lesions located in native coronary arteries, ranging from ≥2.25 to ≤4.0 mm in diameter. Secondary objectives were to establish the medium-term safety, effectiveness, and performance of the Mirage device.

    BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns.

    METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months.

    RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups.

    CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.

    Matched MeSH terms: Coronary Angiography*
  12. Tan SK, Yeong CH, Raja Aman RRA, Ng KH, Abdul Aziz YF, Chee KH, et al.
    Br J Radiol, 2018 Jul;91(1088):20170874.
    PMID: 29493261 DOI: 10.1259/bjr.20170874
    OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods.

    METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.

    RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.

    CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.

    Matched MeSH terms: Coronary Angiography/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links