Displaying publications 1 - 20 of 51 in total

Abstract:
Sort:
  1. Zabir, A.F., Frawley, G., Squire, P.
    MyJurnal
    We here describe a videolaryngoscope assisted fibreoptic tracheal intubation in a 17-year-old patient with Hunter Syndrome (Mucopolysaccharidosis Type II) and known difficult intubation who required posterior cervical fusion surgery for cervical canal stenosis. The patient had a history of failed nasal and oral fibreoptic intubation. The use of a videolaryngoscope enabled continuous visualization of the tracheal inlet and allowed a straightforward nasal fibreoptic intubation attempt without complications. This report suggests a viable alternative for the management of a known difficult airway in children with mucopolysaccharidosis.
    Matched MeSH terms: Fiber Optic Technology
  2. Al-Mansoori MH, Mahdi MA
    Opt Express, 2008 May 26;16(11):7649-54.
    PMID: 18545472
    We demonstrate an enhanced multiwavelength L-band Brillouin-erbium fiber laser (BEFL), in which the Brillouin pump is pre-amplified before entering the single-mode fiber. The Brillouin pump pre-amplification provided by the Erbium-doped fiber has created higher intensity of Brillouin Stokes line generated in the single-mode fiber that leads to the homogenous gain saturation. Thus the built-up of self-lasing cavity modes is suppressed in a wider wavelength range. In contrary to the conventional linear-cavity BEFL, the number of output channels is enhanced within the same tuning range.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  3. Zainudin BM, Rafia MH, Sufarlan AW
    Singapore Med J, 1993 Apr;34(2):148-9.
    PMID: 8266157
    Lignocaine spray for anaesthetising the nasal mucosa for fibreoptic bronchoscopy often causes discomfort to the patient. We compared two techniques of applying nasal topical anaesthesia using either lignocaine spray (group A: 25 patients) or gel (group B: 30 patients) to assess patients' tolerance to the procedure. Both groups received 100 mg of lignocaine in the nostril, 40-50 mg to oropharynx, 120 mg to vocal cords and 40-100 mg to trachea and bronchi. Throat anaesthesia was the most common unpleasant part experienced by both groups of patients (34.5%), followed by examination of bronchi (30.6%) and nasal anaesthesia (21.8%). Significantly more patients in group A experienced discomfort or pain during nasal anaesthesia as compared to group B (p < 0.001). Patients' tolerance to the bronchoscopy was similar in both groups and the examination was performed satisfactorily in all patients. Thus, lignocaine gel is a simple technique, effective and less irritating as compared to lignocaine spray for topical nasal anaesthesia.
    Matched MeSH terms: Fiber Optic Technology
  4. Prepageran N, Omar R, Raman R
    Ear Nose Throat J, 2005 Sep;84(9):564.
    PMID: 16261756
    Matched MeSH terms: Fiber Optic Technology
  5. Hashim S, Bradley DA, Saripan MI, Ramli AT, Wagiran H
    Appl Radiat Isot, 2010 Apr-May;68(4-5):700-3.
    PMID: 19892557 DOI: 10.1016/j.apradiso.2009.10.027
    This paper describes a preliminary study of the thermoluminescence (TL) response of doped SiO(2) optical fibres subjected to (241)AmBe neutron irradiation. The TL materials, which comprise Al- and Ge-doped silica fibres, were exposed in close contact with the (241)AmBe source to obtain fast neutron interactions through use of measurements obtained with and without a Cd filter (the filter being made to entirely enclose the fibres). The neutron irradiations were performed for exposure times of 1-, 2-, 3-, 5- and 7-days in a neutron tank filled with water. In this study, use was also made of the Monte Carlo N-particle (MCNP) code version 5 (V5) to simulate the neutron irradiations experiment. It was found that the commercially available Ge-doped and Al-doped optical fibres show a linear dose response subjected to fast neutrons from (241)AmBe source up to seven days of irradiations. The simulation performed using MCNP5 also exhibits a similar pattern, albeit differing in sensitivity. The TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre, the total absorption cross section for Ge in both the fast and thermal neutrons region being some ten times greater than that of Al.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  6. Al-Fakih EA, Osman NA, Eshraghi A, Adikan FR
    Sensors (Basel), 2013 Aug 12;13(8):10348-57.
    PMID: 23941909 DOI: 10.3390/s130810348
    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  7. Chong SS, Aziz AR, Harun SW, Arof H
    Sensors (Basel), 2014;14(9):15836-48.
    PMID: 25166498 DOI: 10.3390/s140915836
    In this study, the construction and test of tapered plastic optical fiber (POF) sensors, based on an intensity modulation approach are described. Tapered fiber sensors with different diameters of 0.65 mm, 0.45 mm, and 0.35 mm, were used to measure various concentrations of Remazol black B (RBB) dye aqueous solutions at room temperature. The concentrations of the RBB solutions were varied from 0 ppm to 70 ppm. In addition, the effect of varying the temperature of the RBB solution was also investigated. In this case, the output of the sensor was measured at four different temperatures of 27 °C, 30 °C, 35 °C, and 40 °C, while its concentration was fixed at 50 ppm and 100 ppm. The experimental results show that the tapered POF with d = 0.45 mm achieves the best performance with a reasonably good sensitivity of 61 × 10(-4) and a linearity of more than 99%. It also maintains a sufficient and stable signal when heat was applied to the solution with a linearity of more than 97%. Since the transmitted intensity is dependent on both the concentration and temperature of the analyte, multiple linear regression analysis was performed to combine the two independent variables into a single equation. The resulting equation was then validated experimentally and the best agreement between the calculated and experimental results was achieved by the sensor with d = 0.45 mm, where the minimum discrepancy is less than 5%. The authors conclude that POF-based sensors are suitable for RBB dye concentration sensing and, with refinement in fabrication, better results could be achieved. Their low fabrication cost, simple configuration, accuracy, and high sensitivity would attract many potential applications in chemical and biological sensing.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  8. Isah BW, Mohamad H
    Sensors (Basel), 2021 Apr 22;21(9).
    PMID: 33922008 DOI: 10.3390/s21092926
    The paper explores the possibility of using high-resolution fiber Bragg grating (FBG) sensing technology for on-specimen strain measurement in the laboratory. The approach provides a means to assess the surface deformation of the specimen, both the axial and radial, through a chain of FBG sensor (C-FBG), in a basic setup of a uniaxial compression test. The method is cost-effective, straightforward and can be commercialized. Two C-FBG; one was applied directly to the sample (FBGBare), and the other was packaged (FBGPack) for ease of application. The approach measures the local strain with high-resolution and accuracy levels that match up to the existing local strain measuring sensors. The approach enables the evaluation of small-strain properties of the specimen intelligently. The finite element model analysis deployed has proven the adaptability of the technique for measuring material deformation. The adhesive thickness and packaging technique have been shown to influence the sensitivity of the FBG sensors. Owing to the relative ease and low-cost of instrumentation, the suggested method has a great potential to be routinely applied for elemental testing in the laboratory.
    Matched MeSH terms: Fiber Optic Technology
  9. Kamuri MF, Zainal Abidin Z, Yaacob MH, Hamidon MN, Md Yunus NA, Kamarudin S
    Biosensors (Basel), 2019 Mar 14;9(1).
    PMID: 30875829 DOI: 10.3390/bios9010040
    This paper describes the development of an integrated system using a dry film resistant (DFR) microfluidic channel consisting of pulsed field dielectrophoretic field-flow-fractionation (DEP-FFF) separation and optical detection. The prototype chip employs the pulse DEP-FFF concept to separate the cells (Escherichia coli and Saccharomyces cerevisiae) from a continuous flow, and the rate of release of the cells was measured. The separation experiments were conducted by changing the pulsing time over a pulsing time range of 2⁻24 s and a flow rate range of 1.2⁻9.6 μ L min - 1 . The frequency and voltage were set to a constant value of 1 M Hz and 14 V pk-pk, respectively. After cell sorting, the particles pass the optical fibre, and the incident light is scattered (or absorbed), thus, reducing the intensity of the transmitted light. The change in light level is measured by a spectrophotometer and recorded as an absorbance spectrum. The results revealed that, generally, the flow rate and pulsing time influenced the separation of E. coli and S. cerevisiae. It was found that E. coli had the highest rate of release, followed by S. cerevisiae. In this investigation, the developed integrated chip-in-a lab has enabled two microorganisms of different cell dielectric properties and particle size to be separated and subsequently detected using unique optical properties. Optimum separation between these two microorganisms could be obtained using a longer pulsing time of 12 s and a faster flow rate of 9.6 μ L min - 1 at a constant frequency, voltage, and a low conductivity.
    Matched MeSH terms: Fiber Optic Technology/instrumentation; Fiber Optic Technology/methods*
  10. Teah MK, Liew EHR, Wong MTF, Yeap TB
    BMJ Case Rep, 2021 Feb 19;14(2).
    PMID: 33608338 DOI: 10.1136/bcr-2020-238600
    Awake fibreoptic intubation (AFOI) is an established modality in patients with anticipated difficulty with tracheal intubation. This case demonstrates that with careful and meticulous preparations, AFOI can lead to improved airway management and excellent patient outcomes. A 38-year-old woman presented with severe trismus secondary to odentogenous abscess was identified preoperatively as having a potential difficult airway. AFOI was performed successfully using combined Spray-As-You-Go and dexmedetomidine technique.
    Matched MeSH terms: Fiber Optic Technology*
  11. Ajiya M, Mahdi MA, Al-Mansoori MH, Hitam S, Mokhtar M
    Opt Express, 2009 Apr 13;17(8):5944-52.
    PMID: 19365413
    We experimentally demonstrate a simple widely tunable multiwavelength Brillouin/Erbium fiber laser that can be tuned over the entire C-band, thereby greatly improving the tuning range limitation faced by the previous Brillouin-erbium fiber laser architectures. Tuning range of 39 nm from 1527 nm to 1566 nm, which is only limited by the amplification bandwidth of the erbium gain was successfully achieved. At Brillouin pump wavelength of 1550 nm and 1480 nm laser pump and Brillouin pump powers of 130 mW and 2 mW respectively, all the generated output channels have peak power above 0 dBm, with the first output channel having a peak power of 8.52 dBm. The experimental set up that consists of only 4 optical components, is simple, devoid of the complex structure employed previously to enhance the tunability and feedback mechanism normally associated with multiwavelength Brillouin-erbium fiber laser sources. The generated output channels are stable, rigidly separated by 10 GHz (0.08 nm).
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  12. Lim KS, Jasim AA, Damanhuri SS, Harun SW, Rahman BM, Ahmad H
    Appl Opt, 2011 Oct 20;50(30):5912-6.
    PMID: 22015420 DOI: 10.1364/AO.50.005912
    Effects of immersing a microfiber knot resonator (MKR) in liquid solutions that have refractive indices close to that of silica are experimentally demonstrated and theoretically analyzed. Significant improvement in resonance extinction ratio within 2 to 10 dB was observed. To achieve a better understanding, a qualitative analysis of the coupling ratio and round-trip attenuation of the MKR is performed by using a curve-fitting method. It was observed that the coupling coefficient at the knot region increased when immersed in liquids. However, depending on the initial state of the coupling and the quantity of the increment in the coupling coefficient when immersed in a liquid, it is possible that the MKR may experience a deficit in the coupling parameter due to the sinusoidal relationship with the coupling coefficient.
    Matched MeSH terms: Fiber Optic Technology
  13. Yang HZ, Lim KS, Qiao XG, Chong WY, Cheong YK, Lim WH, et al.
    Opt Express, 2013 Jun 17;21(12):14808-15.
    PMID: 23787668 DOI: 10.1364/OE.21.014808
    We present a new theoretical model for the broadband reflection spectra of etched FBGs which includes the effects of axial contraction and stress-induced index change. The reflection spectra of the etched FBGs with several different taper profiles are simulated based on the proposed model. In our observation, decaying exponential profile produces a broadband reflection spectrum with good uniformity over the range of 1540-1560 nm. An etched FBG with similar taper profile is fabricated and the experimental result shows good agreement with the theoretical model.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  14. Qazi HH, bin Mohammad AB, Akram M
    Sensors (Basel), 2012 Nov 29;12(12):16522-56.
    PMID: 23443392 DOI: 10.3390/s121216522
    Optical chemical sensors have promoted escalating interest in the determination of various pollutants in the environment, which are creating toxicity and may cause serious health problems. This review paper focuses particularly on the recent progress and developments in this field; the working principles and basic classes of optical chemical sensors have been briefly described.
    Matched MeSH terms: Fiber Optic Technology
  15. Abdul Rahim R, Leong LC, Chan KS, Rahiman MH, Pang JF
    ISA Trans, 2008 Jan;47(1):3-14.
    PMID: 17709106
    This paper presents the implementing multiple fan beam projection technique using optical fibre sensors for a tomography system. From the dynamic experiment of solid/gas flow using plastic beads in a gravity flow rig, the designed optical fibre sensors are reliable in measuring the mass flow rate below 40% of flow. Another important matter that has been discussed is the image processing rate or IPR. Generally, the applied image reconstruction algorithms, the construction of the sensor and also the designed software are considered to be reliable and suitable to perform real-time image reconstruction and mass flow rate measurements.
    Matched MeSH terms: Fiber Optic Technology
  16. Abu Hassan MR, Abu Bakar MH, Dambul K, Adikan FR
    Sensors (Basel), 2012;12(11):15820-6.
    PMID: 23202233 DOI: 10.3390/s121115820
    In this paper, we present the development and testing of an optical-based sensor for monitoring the corrosion of reinforcement rebar. The testing was carried out using an 80% etched-cladding Fibre Bragg grating sensor to monitor the production of corrosion waste in a localized region of the rebar. Progression of corrosion can be sensed by observing the reflected wavelength shift of the FBG sensor. With the presence of corrosion, the etched-FBG reflected spectrum was shifted by 1.0 nm. In addition, with an increase in fringe pattern and continuously, step-like drop in power of the Bragg reflected spectrum was also displayed.
    Matched MeSH terms: Fiber Optic Technology
  17. Shaddad RQ, Mohammad AB, Al-Gailani SA, Al-Hetar AM
    ScientificWorldJournal, 2014;2014:170471.
    PMID: 24772009 DOI: 10.1155/2014/170471
    The optical fiber is well adapted to pass multiple wireless signals having different carrier frequencies by using radio-over-fiber (ROF) technique. However, multiple wireless signals which have the same carrier frequency cannot propagate over a single optical fiber, such as wireless multi-input multi-output (MIMO) signals feeding multiple antennas in the fiber wireless (FiWi) system. A novel optical frequency upconversion (OFU) technique is proposed to solve this problem. In this paper, the novel OFU approach is used to transmit three wireless MIMO signals over a 20 km standard single mode fiber (SMF). The OFU technique exploits one optical source to produce multiple wavelengths by delivering it to a LiNbO3 external optical modulator. The wireless MIMO signals are then modulated by LiNbO3 optical intensity modulators separately using the generated optical carriers from the OFU process. These modulators use the optical single-sideband with carrier (OSSB+C) modulation scheme to optimize the system performance against the fiber dispersion effect. Each wireless MIMO signal is with a 2.4 GHz or 5 GHz carrier frequency, 1 Gb/s data rate, and 16-quadrature amplitude modulation (QAM). The crosstalk between the wireless MIMO signals is highly suppressed, since each wireless MIMO signal is carried on a specific optical wavelength.
    Matched MeSH terms: Fiber Optic Technology*
  18. Isha A, Yusof NA, Ahmad M, Suhendra D, Yunus WM, Zainal Z
    Spectrochim Acta A Mol Biomol Spectrosc, 2007 Aug;67(5):1398-402.
    PMID: 17141557
    Fatty hydroxamic acid (FHA) immobilized in polyvinyl chloride (PVC) has been studied as a sensor element of an optical fibre chemical sensor for V(V). By using this instrument, V(V) in solution has been determined in the log concentration range of 0-2.5 (i.e. 1.0-300 mg/L). The detection limit was 1.0 mg/L. The relative standard deviation (R.S.D.) of the method for the reproducibility study at V(V) concentration of 200 mg/L and 300 mg/L were calculated to be 2.9% and 2.0%, respectively. Interference from foreign ions was also studied at 1:1 mole ratio of V(V):foreign ions. It was found that, Fe(III) ion interfered most in the determination of vanadium(V). Excellent agreement with ICP-AES method was achieved when the proposed method was applied towards determination of V(V).
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  19. Nurul Syafiqah Hirman, Nur Athirah Mohd Taib
    MyJurnal
    A simple and low-cost Fiber Optic Displacement Sensor (FODS) using reflective intensity modulation technique was developed to analyze various concentrations of Pb2+, a compound classified under heavy metal ions. Lead is harmful to the environment including to human but is used in the cosmetic field for beauty without realizing and considering the hazardousness of lead as it would cause a long-term effect. Therefore, a feasible way has been identified in this study to demonstrate the level of Pb2+ concentration in cosmetics field by employing the theory of modulation of intensity as a function of displacement sensor. The permissible limit according to Malaysian Cosmetics Guidelines and ASEAN Cosmetic Directive was 20 ppm. The concentration sensor’s system exhibits 0.0018 V/ppm sensitivity with a linearity of 96% and 94% respectively, for both peaks. Meanwhile, the sensitivity was 0.034 V/ppm for the first peak and 27.72 V/ppm for the second peak, with slope linearity of more than 96% for surface tension parameter. The credibility of these optical response curves data might be useful, especially in the cosmetic’s industrial application.

    Matched MeSH terms: Fiber Optic Technology
  20. Mohd Zulfakar Mazlan, Shamsul Kamalrujan Hassan, Laila Abd Mukmin, Mohd Hasyizan Hassan, Huda Zainal Abiddin, Irfan Mohamad, et al.
    MyJurnal
    Giant haemangioma of the tongue is a disease which can
    obstruct the oropharyngeal airway and is presented with
    obstructive symptoms. Due to its vascularity, inserting
    laryngoscope for intubation can cause high risks, such as
    inducing bleeding. Hypoxia and excessive bleeding must be
    anticipated while securing the airway. We present a case of
    novel usage of dexmedetomidine as a conscious sedation agent
    for awake fibre optic intubation in a 9-year-old child with
    obstructive symptoms secondary to a huge tongue
    haemangioma, who was presented for interventional
    sclerotherapy of the lesion.
    Matched MeSH terms: Fiber Optic Technology
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links