Displaying publications 21 - 40 of 45 in total

Abstract:
Sort:
  1. Mah HY, Ishak WS, Abd Rahman MH
    Geriatr Gerontol Int, 2020 Oct;20(10):911-916.
    PMID: 32820857 DOI: 10.1111/ggi.14011
    The present study aimed to examine the prevalence of dual sensory impairment, and to identify its risk factors among community-dwelling older adults in Selangor.

    METHODS: Secondary analysis was carried out on data collected by the Grand Challenge Project among older adults aged ≥65 years from Selangor. Data on sociodemographic information, medical history, cognitive function and functional performance were obtained through face-to-face interviews using standardized questionnaires. Visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) chart while hearing was assessed using pure-tone audiometry. Descriptive analysis was used to measure the prevalence of the impairments, and logistic regression analysis was used to identify the risk factors.

    RESULTS: The prevalence of dual sensory impairment and hearing impairment were at 10.5% and 76.2% respectively. Multivariate logistic regression analysis revealed that participants with lower cognitive scores were associated with dual sensory impairment (odds ratio, 0.90; 95% confidence interval, 0.83-0.98), while smoking was found associated with hearing impairment (odds ratio, 6.58; 95% confidence interval, 1.51-28.65).

    CONCLUSION: Dual sensory impairment is common among older adults in Selangor. The association between dual sensory impairment and cognitive function suggests the need to have visual and hearing screening on older adults for early detection particularly those at risk of cognitive impairment. The prevalence of hearing impairment was reported high among older adults and smokers appeared to be at higher risk of the impairment. Geriatr Gerontol Int 2020; 20: 911-916.

    Matched MeSH terms: Audiometry, Pure-Tone
  2. Toh, Teck Hock, Nurhilda Abdullah, Chua, Soh Yian, Muhamad Rais Abdullah, Islia Nahazatul, Chieng, Lee Ling
    Int J Public Health Res, 2011;1(2):66-71.
    MyJurnal
    Introduction Special Olympics (SO) Inc. is an organization for people with intellectual disability (ID) to actively engaging in Olympic-type sport and participating in competition. Special Olympic Inc. provides Healthy Athletes Programme (HAP®) in screening and providing health education to Special Olympic Athletes. Objective To study the body mass index (BMI), blood pressure (BP), visual acuity and hearing status of children and young adult with ID in Special Olympics Sarawak. Methods Health data were collected by trained health professionals under HAP®held in conjunction with Special Olympics Sarawak State Games on 17th and 18th April 2010 in Sibu. Health data collected were athletes' weight, BMI, BP, ear canal screen and hearing status (oto-acoustic emission, pure tone audiometry), as well as eye health and visual acuity, using guidelines set by HAP®. Results 195 athletes attended the State Games in 2010 of which 138 were screened. Significant number of athletes was considered overweight / obese (31.5% for children and 36.9% for adult). More than 20% of the adult athletes were hypertensive or at risk of hypertension. Sixteen percent of the adult athletes had hearing loss. More than half of the adult and children athletes never had eye checks, and a significant numbers of them had abnormal eye tests results. Conclusions Health screening conducted during the HAP® is a useful screening program in this population. Health data collected can bring awareness to athletes and their family, and corrective measures in hearing and visual impairment can be taken immediately.
    Matched MeSH terms: Audiometry, Pure-Tone
  3. Ishak MN, Nik-Abdul-Ghani NM, Mohamad I
    Iran J Otorhinolaryngol, 2018 Mar;30(97):113-116.
    PMID: 29594079
    Introduction: Sudden sensorineural hearing loss (SSNHL) is an important otological emergency. Up to 90% of the cases are idiopathic. Cerebral venous thrombosis (CVT) is an extremely rare identifiable cause as it only represents 0.5% of all strokes.

    Case Report: In this paper, an unusual case of bilateral SSNHL secondary to bilateral CVT with rapid and complete recovery is reported. The patient presented with sudden bilateral hearing loss associated with some neurological symptoms. Initial computed tomography (CT) venography revealed a CVT of bilateral transverse sinuses. The patient was started on an anticoagulant and imaging was repeated after five days, revealing the absence of the thrombosis. Serial pure tone audiometry (PTA) showed complete recovery of bilateral hearing within 10 days.

    Conclusion: Early detection and intervention may fasten hearing recovery and improve the quality of life. The immediate restoration of venous blood flow and intracranial pressure may lead to the complete recovery of bilateral hearing loss.

    Matched MeSH terms: Audiometry, Pure-Tone
  4. Zakaria MN, Abdullah R, Nik Othman NA
    Ear Hear, 2018 11 22;40(4):1039-1042.
    PMID: 30461445 DOI: 10.1097/AUD.0000000000000676
    OBJECTIVES: Post-auricular muscle response (PAMR) is a large myogenic potential that can be useful in estimating behavioral hearing thresholds when the recording protocol is optimal. The main aim of the present study was to determine the influence of stimulus repetition rate on PAMR threshold.

    DESIGN: In this repeated-measures study, 20 normally hearing adults aged between 18 and 30 years were recruited. Tone bursts (500, 1000, 2000, and 4000 Hz) were used to record PAMR thresholds at 3 different stimulus repetition rates (6.1/s, 11.1/s, and 17.1/s).

    RESULTS: Statistically higher PAMR thresholds were found for the faster stimulus rate (17.1/s) compared with the slower stimulus rate (6.1/s) (p < 0.05). For all stimulus rates and frequencies, significant correlations were found between PAMR and pure-tone audiometry thresholds (r = 0.62 to 0.82).

    CONCLUSIONS: Even though the stimulus rate effect was significant at most of the tested frequencies, the differences in PAMR thresholds between the rates were small (<5 dB). Nevertheless, based on the correlation results, we suggest the use of 11.1/s stimulus rate when recording PAMR thresholds.

    Matched MeSH terms: Audiometry, Pure-Tone
  5. Wahab NA, Rashid MF
    Singapore Med J, 2009 Nov;50(11):1077-9.
    PMID: 19960163
    INTRODUCTION: The present study aimed to obtain preliminary tympanometric data of young Malay adults and to compare the results between genders.
    METHODS: 96 undergraduate students (49 males and 47 females), aged 19-25 (mean and standard deviation 21.14 +/- 1.31) years, participated in this study. Otoscopic examination, pure tone audiometry, qualitative tympanogram and ipsilateral acoustic reflex were measured to ensure a clear ear canal, normal hearing and normal middle ear function, prior to tympanometric measurement. As a result, a total of 154 ears (80 ears from males and 74 ears from females) were selected for further statistical analyses. The tympanometric parameters measured were peak compensated static acoustic admittance (Peak Y(tm)), tympanometric width (TW) and equivalent ear canal volume (V(ea)).
    RESULTS: The results showed that the mean Peak Y(tm), V(ea) and TW for males were 0.81 mmhos, 1.48 cubic cm and 113.67 daPa, respectively. The mean Peak Y(tm), V(ea) and TW for females were 0.63 mmhos, 1.12 cubic cm and 98.04 daPa, respectively. Males were found to have significantly higher mean V(ea) and mean Peak Y(tm) than females. However no significant gender difference was observed in the mean TW.
    CONCLUSION: The current study suggests that young Malay adults may require gender-specific Peak Y(tm) and V(ea) values when implementing a quantitative approach in tympanogram interpretation.
    Matched MeSH terms: Audiometry, Pure-Tone
  6. Arvin B, Prepageran N, Raman R
    Indian J Otolaryngol Head Neck Surg, 2013 Dec;65(Suppl 3):480-4.
    PMID: 24427701 DOI: 10.1007/s12070-011-0356-x
    The objective of this study is to determine whether presbycusis occurs much earlier than previously believed if the high frequency (above 8 kHz) are included. Tertiary referral center (a teaching University). This is a cross-sectional observational study. Healthy adults from 20 to 49 years of age who had essentially normal hearing were included into the study. They were subjected to high frequency pure tone audiometry (until 16 kHz). Participants were grouped based on age ranges of 10 years (e.g., 20-29, 30-39, and 40-49) and the presence of symmetrical high frequency sensor neural hearing loss were documented. There is a significant presence of symmetrical high frequency sensor neural hearing loss (not attributed to any known risk factors) as early as from the age group of 40 to 49 years. Seven of 43 participants (16%) from age group of 20 to 29 years and 12 of 24 participants (50%) from age group of 30 to 39 years had significant high frequency hearing loss. High frequency hearing loss (high frequency Presbycusis) may occur much earlier than previously believed.
    Matched MeSH terms: Audiometry, Pure-Tone
  7. Bokari S, Prepageran N, Raman R
    PMID: 23120679 DOI: 10.1007/s12070-010-0004-x
    OBJECTIVE: To determine if visual analog scale (VAS) that has been used to measure magnitude of internal states such as pain, mood and various functional capabilities can be applied for patients with hearing loss.

    MATERIALS AND METHODS: One hundred and sixty patients, aged 12-80 years with unilateral hearing loss were studied using a VAS (1-10) and pure tone audiometry (PTA) of responses to 500, 1,000 and 2,000 Hz to determine degree and type of hearing loss. The results of both were compared to determine if VAS can be used in measuring hearing loss.

    RESULTS: Patients with mild, moderate hearing loss correlate well with corresponding VAS but other degrees of hearing loss (severe and profound) have poor correlation. The best correlation between PTA and VAS were found in conductive type of hearing loss.

    CONCLUSION: This study suggest that there may be a role for VAS in mild and moderate hearing loss. This may be more applicable in rural setting as a screening procedure when audiometry is not available and can enhance clinical hearing assessment especially in mild-to-moderate conductive hearing loss.

    Matched MeSH terms: Audiometry, Pure-Tone
  8. Ibrahim IA, Ting HN, Moghavvemi M
    J Int Adv Otol, 2019 Apr;15(1):87-93.
    PMID: 30924771 DOI: 10.5152/iao.2019.4553
    OBJECTIVES: This study uses a new approach for classifying the human ethnicity according to the auditory brain responses (electroencephalography [EEG] signals) with a high level of accuracy. Moreover, the study presents three different algorithms used to classify the human ethnicity using auditory brain responses. The algorithms were tested on Malays and Chinese as a case study.

    MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy.

    RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%.

    CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.

    Matched MeSH terms: Audiometry, Pure-Tone/methods
  9. Lim EY, Tang IP, Peyman M, Ramli N, Narayanan P, Rajagopalan R
    Eur Arch Otorhinolaryngol, 2015 Nov;272(11):3109-13.
    PMID: 25205300 DOI: 10.1007/s00405-014-3232-y
    High acoustic noise level is one of the unavoidable side effects of 3 T magnetic resonance imaging (MRI). A case of hearing loss after 3 T MRI has been reported in this institution and hence this study. The objective of this study was to determine whether temporary threshold shift (TTS) in high frequency hearing occurs in patients undergoing 3 T MRI scans of the head and neck. A total of 35 patients undergoing head and neck 3 T MRI for various clinical indications were tested with pure tone audiometry in different frequencies including high frequencies, before and after the MRI scan. Any threshold change from the recorded baseline of 10 dB was considered significant. All patients were fitted with foamed 3 M earplugs before the procedure following the safety guidelines for 3 T MRI. The mean time for MRI procedure was 1,672 s (range 1,040-2,810). The noise dose received by each patient amounted to an average of 3,906.29% (1,415-9,170%). The noise dose was derived from a normograph used by Occupational Noise Surveys. This was calculated using the nomograph of L eq, L EX, noise dose and time. There was no statistically significant difference between the hearing threshold before and after the MRI procedures for all the frequencies (paired t test, P > 0.05). For patients using 3 M foamed earplugs, noise level generated by 3 T MRI during routine clinical sequence did not cause any TTS in high frequency hearing.
    Matched MeSH terms: Audiometry, Pure-Tone
  10. Balachandran R, Prepageran N, Prepagaran N, Rahmat O, Zulkiflee AB, Hufaida KS
    J Laryngol Otol, 2012 Apr;126(4):345-8.
    PMID: 22310164 DOI: 10.1017/S0022215112000047
    The Bluetooth wireless headset has been promoted as a 'hands-free' device with a low emission of electromagnetic radiation.
    Matched MeSH terms: Audiometry, Pure-Tone
  11. Rahmat S, O'Beirne GA
    Hear Res, 2015 Dec;330(Pt A):125-33.
    PMID: 26209881 DOI: 10.1016/j.heares.2015.07.013
    Schroeder-phase masking complexes have been used in many psychophysical experiments to examine the phase curvature of cochlear filtering at characteristic frequencies, and other aspects of cochlear nonlinearity. In a normal nonlinear cochlea, changing the "scalar factor" of the Schroeder-phase masker from -1 through 0 to +1 results in a marked difference in the measured masked thresholds, whereas this difference is reduced in ears with damaged outer hair cells. Despite the valuable information it may give, one disadvantage of the Schroeder-phase masking procedure is the length of the test - using the conventional three-alternative forced-choice technique to measure a masking function takes around 45 min for one combination of probe frequency and intensity. As an alternative, we have developed a fast method of recording these functions which uses a Békésy tracking procedure. Testing at 500 Hz in normal hearing participants, we demonstrate that our fast method: i) shows good agreement with the conventional method; ii) shows high test-retest reliability; and iii) shortens the testing time to 8 min.
    Matched MeSH terms: Audiometry, Pure-Tone
  12. Krishnan G
    Med J Malaysia, 1994 Mar;49(1):44-8.
    PMID: 8057990
    The common investigations done were pure tone audiometry, electronystagmography, X-ray of the internal auditory meatus, CT-scan of the internal auditory meatus and X-ray of the cervical spine. After the examinations and investigations only 52 patients out of the 107 could be given any diagnosis. The most common diagnosis for the vertigo was Meniere's disease.
    Matched MeSH terms: Audiometry, Pure-Tone
  13. Gendeh BS, Said H, Gibb AG, Aziz NS, Zahir ZM
    J Laryngol Otol, 1991 Dec;105(12):999-1001.
    PMID: 1787382
    In a prospective study on 47 patients, 16 mg of gentamicin per two litres dialysate was administered intraperitoneally at every cycle of intermittent peritoneal dialysis, carried out over the course of several days. Serum gentamicin sampling, pure tone audiometry and caloric tests were performed before and during the treatment. The gentamicin levels reached at the end of the thirtieth cycle were observed to be low. In view of this, the risk of acute ototoxicity was considered to be minimal. This was confirmed by the absence of clinical audiometric or vestibulometric evidence of toxicity.
    Matched MeSH terms: Audiometry, Pure-Tone
  14. Goh LC, Azman A, Siti HBK, Khoo WV, Muthukumarasamy PA, Thong MK, et al.
    Int J Pediatr Otorhinolaryngol, 2018 Jun;109:50-53.
    PMID: 29728184 DOI: 10.1016/j.ijporl.2018.03.010
    OBJECTIVE: To study the audiological outcome and early screening of pre-school going children with craniosynostosis under follow-up at the University of Malaya Medical Center(UMMC), Kuala Lumpur, Malaysia over a 10 year period.

    METHODS: A retrospective descriptive cohort study on the audiological findings detected during the first hearing assessment done on a child with craniosynostosis using otoacoustic emissions, pure tone audiometry or auditory brainstem response examination. The main aim of this study was to evaluate the type and severity of hearing loss when compared between syndromic and non-sydromic craniosynostosis, and other associated contributory factors.

    RESULTS: A total of 31 patients with 62 ears consisting of 14 male patients and 17 female patients were evaluated. Twenty two patients (71%) were syndromic and 9 (29%) were non-syndromic craniosynostosis. Amongst the syndromic craniosynostosis, 9 (41%) had Apert syndrome, 7 (32%) had Crouzon syndrome, 5 (23%) had Pfieffer syndrome and 1 (4%) had Shaethre Chotzen syndrome. Patients with syndromic craniosynostosis were more likely to present with all types and severity of hearing loss, including severe to profound sensorineural hearing loss while children with non-syndromic craniosynostosis were likely to present with normal hearing (p 

    Matched MeSH terms: Audiometry, Pure-Tone
  15. Goh BS, Tang CL, Hashim ND, Annamalay T, Abd Rahman FN
    PMID: 30578988 DOI: 10.1016/j.ijporl.2018.12.010
    OBJECTIVE: There is a dearth of studies on long term hearing status and behavioural patterns among cleft lip and/or palate children after their primary lip and palate closure in Malaysia. This study describes the audiology status and behavioural patterns in a group of school aged children with cleft lip and/or palate.

    METHOD: A cross sectional study was carried out where caretakers of cleft lip and/or palate were asked to complete the translated Malay language version of Strength Difficulties Questionnaire. The hearing status of the children was analyzed based on recent pure tone audiometric and tympanogram results. The patients' age, gender, type of cleft pathology, age of palatal surgery and behavioural patterns were examined for their potential relationship with hearing status.

    RESULTS: A total of 74 children (148 ears) aged between 7 and 17 years with cleft lip and/or palate were recruited. The result showed 37 ears (25.0%) had hearing loss with majority suffered from mild conductive hearing loss. There were 16 ears (10.8%) that had persistent middle ear effusion. Hearing improvement occurred when palatal repair was performed at the age of less than 1 year old. (p = 0.015) There was no significant relationship between patients' gender, age, type of cleft and history of myringotomy with their hearing status. In terms of behavioural patterns, 16.3% were abnormal for total behavioural score, 39.2% for peer problem and 17.6% for conduct problem. For prosocial behaviour, 16.3% were rated low and very low. There was fair correlation between age and hyperactivity problems (r = 0.44). Patients' gender, type of cleft pathology, had been teased apart and hearing status was found not related to behavioural problems.

    CONCLUSION: Cleft lip and/or palate patients have a good longterm hearing outcome. Majority had normal hearing and if there is hearing impairment, it is only a mild loss. Early palatal repair surgery before the age of 1 year can significantly reduce the risk of hearing loss. Cleft lip and/or palate patients experienced peer problems. There was no significant correlation between behavioural difficulty and hearing status among school-aged children with cleft lip and palate.

    Matched MeSH terms: Audiometry, Pure-Tone
  16. Saniasiaya J
    Ear Nose Throat J, 2021 Apr;100(2_suppl):152S-154S.
    PMID: 32755405 DOI: 10.1177/0145561320946902
    Matched MeSH terms: Audiometry, Pure-Tone
  17. Lim CC, Misron K, Liew YT, Wong EHC
    BMJ Case Rep, 2019 Nov 04;12(11).
    PMID: 31690691 DOI: 10.1136/bcr-2019-232275
    Acoustic neuroma (AN) usually manifests with asymmetric hearing loss, tinnitus, dizziness and sense of disequilibrium. About 10% of patients complain of atypical symptoms, which include facial numbness or pain and sudden onset of hearing loss. Patients with atypical symptoms also tend to have larger tumours due to the delay in investigation. We report a particularly interesting case of a patient presented to us with numbness over her right hemifacial region after a dental procedure without significant acoustic and vestibular symptoms. Physical examination and pure tone audiometry revealed no significant findings but further imaging revealed a cerebellopontine angle mass. The changing trends with easier access to further imaging indicate that the presentation of patients with AN are also changing. Atypical symptoms which are persistent should raise clinical suspicion of this pathology among clinicians.
    Matched MeSH terms: Audiometry, Pure-Tone
  18. Govindaraju R, Omar R, Rajagopalan R, Norlisah R, Kwan-Hoong N
    Auris Nasus Larynx, 2011 Aug;38(4):519-22.
    PMID: 21236610 DOI: 10.1016/j.anl.2010.12.006
    The higher field strength magnetic resonance imaging (MRI) such as 3 Tesla (T) and above generates noise that has potential detrimental effects on the hearing. Temporary threshold shifts following MRI examination have been reported for MRI with lower field strength. Such effect, however, have not been reported so far for a 3T MRI. We report a case that exemplifies the possible detrimental effects of a 3 T MRI generated noise on the auditory system. Our patient underwent investigation of his chronic backache in a 3 T MRI unit and developed hearing loss and tinnitus post-MRI examination. Hearing assessment was done using pure tone audiogram, distortion product otoacoustic emission (DPOAE) and brainstem electrical response audiometry (BERA) which revealed a unilateral sensorineural hearing loss which recovered within 3 days. However the tinnitus persisted. This is possibly a case of temporary threshold shift following noise exposure. However a sudden sensorineural hearing loss remains the other possibility.
    Matched MeSH terms: Audiometry, Pure-Tone
  19. Ami M, Abdullah A, Awang MA, Liyab B, Saim L
    Laryngoscope, 2008 Apr;118(4):712-7.
    PMID: 18176342 DOI: 10.1097/MLG.0b013e318161e521
    To investigate cochlear outer hair cell function based on distortion product otoacoustic emission (DPOAE) in patients with tinnitus.
    Matched MeSH terms: Audiometry, Pure-Tone
  20. Gendeh BS, Said H, Gibb AG, Aziz NS, Kong N, Zahir ZM
    J Laryngol Otol, 1993 Aug;107(8):681-5.
    PMID: 8409715 DOI: 10.1017/s0022215100124132
    A prospective study was undertaken of 10 chronic renal failure patients on Continuous Ambulatory Peritoneal Dialysis (CAPD) complicated by repeated bouts of peritonitis treated with gentamicin. Each 10-day treatment course consisted of a 120 mg loading dose, followed by 16 mg in 21 of peritoneal dialysate, given four times a day. Serum gentamicin analysed by enzyme immunoassay showed a mean level of 5.2 micrograms/ml, (range 3.7 to 6.6 mg/ml) four hours after the loading dose. Similar levels, well within the therapeutic range, were maintained on the 3rd, 5th, 7th and 9th days of intraperitoneal gentamicin therapy, suggesting no accumulation of gentamicin in the serum. Pure tone audiometry, electronystagmography and clinical assessment were performed during each course of treatment. Although no evidence of ototoxicity was found during the first two courses of gentamicin, but disequilibrium and bobbing oscillopsia were present during the third and fourth courses of gentamicin. These findings could be explained by cumulative injury to the vestibular apparatus caused by repeated therapeutic insults.
    Matched MeSH terms: Audiometry, Pure-Tone
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links