METHODS: A systematic literature review was performed using Pubmed, Web of Science, INAHTA and GIN databases, from inception to June 4, 2020. Three independent reviewers selected eligible studies then extracted and synthesized the evidence. The synthesis was submitted to a multidisciplinary group of experts to provide recommendations.
RESULTS: Two scientific papers and a Malaysian HTA report were included in data synthesis. In light of the resources consulted, spraying disinfectants on humans in booths is not effective and can be toxic. Disinfectants are intended for use on surfaces, not on living tissue and spraying disinfectants on the outside of the body does not kill the virus inside an infected person's body. Furthermore, this procedure may increase the risk of neglecting other effective measures.
CONCLUSION: It is recommended to prohibit the use of disinfection booths in all structures.
MATERIALS AND METHODS: Using a stainless-steel mold, disc-shaped wax patterns with dimensions of 10 mm in diameter and 2 mm thick (in accordance with ADA Specification No. 12) were created and prepared for a total of 75 acrylic samples. Dimensions of all 75 acrylic samples were checked with a digital Vernier caliper. About 25 samples of denture base material were immersed in three different chemical disinfectants: Group I: immersed in chlorhexidine gluconate solution, group II: immersed in sodium hypochlorite solution, and group III: immersed in glutaraldehyde solution. All samples were scrubbed daily for 1 minute with the appropriate disinfectant and submerged for 10 minutes in the same disinfectant. Between disinfection cycles, samples were kept in distilled water at 37°C. Color stability was measured using a reflection spectrophotometer. Surface roughness values were measured by a profilometer at baseline following 15 days and 30 days.
RESULTS: After 15 days, the color stability was better in chlorhexidine gluconate solution group (4.88 ± 0.24) than sodium hypochlorite solution (4.74 ± 0.18) and glutaraldehyde solution group (4.46 ± 0.16). The mean surface roughness was less in glutaraldehyde solution group (2.10 ± 0.19), followed by chlorhexidine gluconate solution group (2.48 ± 0.09) and sodium hypochlorite solution group (2.64 ± 0.03). After 30 days, the color stability was significantly better in chlorhexidine gluconate solution group (4.40 ± 0.02), followed by sodium hypochlorite solution (4.06 ± 0.16) and glutaraldehyde solution group (3.87 ± 0.17). The mean surface roughness was significantly lesser in glutaraldehyde solution group (2.41 ± 0.14), followed by chlorhexidine gluconate solution group (2.94 ± 0.08) and sodium hypochlorite solution group (3.02 ± 0.13).
CONCLUSION: In conclusion, the color stability was significantly better in chlorhexidine gluconate solution group than sodium hypochlorite solution and glutaraldehyde solution group. But the surface roughness was significantly lesser in the glutaraldehyde solution group, followed by the chlorhexidine gluconate and sodium hypochlorite solution group.
CLINICAL SIGNIFICANCE: The maintenance of the prosthesis requires the use of a denture disinfectant; therefore, it is crucial to select one that is effective but would not have a negative impact on the denture base resin's inherent characteristics over time. How to cite this article: Kannaiyan K, Rakshit P, Bhat MPS, et al. Effect of Different Disinfecting Agents on Surface Roughness and Color Stability of Heat-cure Acrylic Denture Material: An In Vitro Study. J Contemp Dent Pract 2023;24(11):891-894.
MATERIALS AND METHODS: Single- (Streptococcus mutans or Lactobacillus acidophilus), dual- (Streptococcus mutans/Lactobacillus Acidophilus), and multi-species (Streptococcus mutans, Actinomyces naeslundii, and Streptococcus sanguis) biofilms were grown on acid-etched dentine discs. Biofilms were incubated (120 min/37 °C) and allowed to grow for 3 days anaerobically. Discs (no treatment) served as control (group 1). Groups II, III, IV, and V were then treated with 2% chlorhexidine, and 2%, 5%, and 10% QAS (20 s). Discs were returned to well plates with 300 μL of bacterial suspension and placed in anaerobic incubator at 37 °C and biofilms redeveloped for 4 days. Confocal microscopy, Raman, CFU, and MTT assay were performed.
RESULTS: Raman peaks show shifts at 1450 cm-1, 1453 cm-1, 1457 cm-1, 1460 cm-1, and 1462 cm-1 for control, 2% CHX, 2%, 5%, and 10% QAS groups in multi-species biofilms. There was reduction of 484 cm-1 band in 10% QAS group. CLSM revealed densely clustered green colonies in control group and red confluent QAS-treated biofilms with significantly lower log CFU for single/dual species. Metabolic activities of Streptococcus mutans and Lactobacillus acidophilus decreased with increasing QAS exposure time.
CONCLUSION: Quaternary ammonium silanes possess antimicrobial activities and inhibit growth of cariogenic biofilms.
CLINICAL SIGNIFICANCE: Available data demonstrated use of QAS as potential antibacterial cavity disinfectant in adhesive dentistry. Experimental QAS can effectively eliminate caries-forming bacteria, when used inside a prepared cavity, and can definitely overcome problems associated with present available cavity disinfectants.
METHODS: the potential of developing natural disinfectant while using watermelon rinds (WR), pineapple (PP), orange peels (OP), palm kernel cake (PKC), and rice bran (RB), via lacto-fermentation was investigated. The obtained lactic acid bacteria (LAB) metabolites were then employed and the in vitro antifungal activity toward five spoilage fungi of mango was tested through liquid and solid systems. Besides, the effect of the produced disinfectant on the fungal growth inhibition and quality of mango was investigated.
RESULTS: the strains Lactobacillus plantarum ATCC8014 and Lactobacillus fermentum ATCC9338 growing in the substrates PKC and PP exhibited significantly higher in vitro antifungal activity against Colletotrichum gloeosporioides and Botryodiplodia theobromae as compared to other tested LAB strains and substrates. The in-situ results demonstrated that mango samples that were treated with the disinfectant produced from PKC fermented with L. plantarum and L. fermentum had the lowest disease incidence and disease severity index after 16 days shelf life, as well as the lowest conidial concentration. Furthermore, PKC that was fermented by L. fermentum highly maintained the quality of the mango.
CONCLUSIONS: lactic acid fermentation of PKC by L. fermentum demonstrated a high potential for use as a natural disinfectant to control C. gloeosporioides and B. theobromae on mango.
METHODS: A qualitative study design in which 15 healthcare workers from nurses (4), pharmacists (3), medical technologies (4) and medical doctors (4) participated: two focus group of three to four participants each and eight in-depth interviews. The thematic sessions were identified, including occupational health and safety policy implementations, hazards experiences, barriers, and strategies for quality improvement for OSH. Focus groups and interviews using transcript-based analysis were identified relating to emerging themes on the challenges they had experienced while accessing provisions of OSH in their workplace.
RESULTS: Majority of the participants revealed the existence of policy on Occupational Health and Safety (provisions, guidelines and regulations on OHS from the government) and mentioned that there were limited OHS officers to supervise the healthcare workers in their workplace. Some have limited accessibility to the requirements of the implementation of OHS (free facemasks, gloves, disinfectants, machines, OSH staff, etc.) among healthcare workers, while the workload of the staff in the implementation of OHS in the workplace gradually increased. The results indicated that the respondents were knowledgeable in the implementation of OHS in the workplace, and that there was no existing ASEAN framework on the protection and promotion of the rights of healthcare workers in their workplace. Facilities need to improve health assessment, and to ensure constant evaluation of the existing laws for healthcare workers (quality assurance of existing policies) in their working areas. Direct access to OSH officers, occupational hazards education, emergency contact etc. must be improved. Adherence must be strengthened to fully comply with the OHS standards.
CONCLUSION: The researchers inferred that issues and concerns regarding compliance on provisions of occupational health and safety among health care workers must be properly addressed through immediate monitoring and reevaluation of personnel in terms of their knowledge and practices in OHS. Barriers and challenges have been identified in the study that can lead to improved compliance among healthcare workers in regards to OHS.