Displaying publications 21 - 40 of 101 in total

Abstract:
Sort:
  1. Buzayan MM
    Prosthet Orthot Int, 2014 Feb;38(1):62-7.
    PMID: 23625838 DOI: 10.1177/0309364613484052
    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication.
    Matched MeSH terms: Prostheses and Implants*
  2. Chai WL, Yong CK, Ngeow WC
    Ann Dent, 2003;10(1):22-26.
    MyJurnal
    Most prosthetic joint infections originate from wound contamination or haematogenous seeding from distant sites of infection. Bacteraemia may follow dental treatment but there is little evidence of it related to prosthetic joint infection. Nevertheless, controversy continues with regards to the effect of dental treatment in patients with prosthetic joints. This article reviews current English literature regarding the use of antibiotic prophylaxis in the dental management of patients with prosthetic joints. Routine antibiotic prophylaxis is not recommended for every patient with prosthetic joints when receiving dental treatments. However, antibiotic prophylaxis may be prescribed for high-risk groups with predisposing factors to infection when undergoing dental treatment with high risk of bacteraemia.
    Matched MeSH terms: Prostheses and Implants*
  3. Chuah HG, Abd Rahim I, Yusof MI
    Comput Methods Biomech Biomed Engin, 2010 Jun;13(3):319-26.
    PMID: 19927241 DOI: 10.1080/10255840903208189
    The stress shielding effect is an event in which the replacement implant limits the load transferred to bone and the ineffective stress in the vertebrae causes bony growth to cease. In the present study, a 3D finite element L4-L5 model was developed and subjected to a 1200 N compression preload. Five groups of muscle forces were applied on L4 under flexion-extension, lateral bending and axial rotation. Topology optimisation was employed for reducing the stress shielding effect by removing the ineffective material from the design domain. The optimised design was designed with polyaryletheretherketone (PEEK) titanium and cortical materials to encounter the shielding response. The stress responses show that the new design increased the stress magnitude by at least 17.10, 18.11 and 18.43% in 4 Nm of flexion-extension, lateral bending and axial rotation, respectively. In conclusion, the material factor did not significantly alter the stress magnitude, but volume was the key factor in reducing the stress shielding effect.
    Matched MeSH terms: Prostheses and Implants*
  4. Cik Rohaida CH, Idris B, Mohd Reusmaazran Y, Rusnah M, Fadzley Izwan AM
    Med J Malaysia, 2004 May;59 Suppl B:156-7.
    PMID: 15468865
    A mixture with different compositions of HA and TCP were synthesize in this work by precipitation method using Ca(NO3)2 4H2 and (NH4)2HPO4 as the starting materials. A mixture with HA and TCP phases in different ratios were produced. The powders were sintered from 1000 degrees C to 1250 degrees C. The phase compositions of the mixtures were then studied via XRD. This work shows that the pH value determines the different phase compositions of the HA-TCP mixture. Chemical analyses were carried out by FTIR. The microstructure was observed under SEM.
    Matched MeSH terms: Prostheses and Implants*
  5. Faisal, A., Ahmad, S.H., Zulmi, W.
    MyJurnal
    Tumour surgery for locally extensive malignant neoplasms of the extremity will sometimes result in extensive composite soft tissue defect. Local flaps are usually inadequate to cover these large defects. More than one tissue flap might be required to cover any exposed neurovascular structures, bone or prosthesis. We present two cases where two composite flaps were simultaneously used to cover extensive surgical defects after ablative tumour resections in the extremity. These resulted in uncomplicated wound healing and limb salvage.
    Matched MeSH terms: Prostheses and Implants
  6. Farook TH, Abdullah JY, Jamayet NB, Alam MK
    J Prosthet Dent, 2021 Feb 15.
    PMID: 33602541 DOI: 10.1016/j.prosdent.2020.07.039
    STATEMENT OF PROBLEM: Computer-aided design (CAD) of maxillofacial prostheses is a hardware-intensive process. The greater the mesh detail is, the more processing power is required from the computer. A reduction in mesh quality has been shown to reduce workload on computers, yet no reference value of reduction is present for intraoral prostheses that can be applied during the design.

    PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.

    MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.

    RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P

    Matched MeSH terms: Prostheses and Implants
  7. Farook TH, Jamayet NB, Abdullah JY, Asif JA, Rajion ZA, Alam MK
    Comput Biol Med, 2020 03;118:103646.
    PMID: 32174323 DOI: 10.1016/j.compbiomed.2020.103646
    OBJECTIVE: To design and compare the outcome of commercial (CS) and open source (OS) software-based 3D prosthetic templates for rehabilitation of maxillofacial defects using a low powered personal computer setup.

    METHOD: Medical image data for five types of defects were selected, segmented, converted and decimated to 3D polygon models on a personal computer. The models were transferred to a computer aided design (CAD) software which aided in designing the prosthesis according to the virtual models. Two templates were designed for each defect, one by an OS (free) system and one by CS. The parameters for analyses were the virtual volume, Dice similarity coefficient (DSC) and Hausdorff's distance (HD) and were executed by the OS point cloud comparison tool.

    RESULT: There was no significant difference (p > 0.05) between CS and OS when comparing the volume of the template outputs. While HD was within 0.05-4.33 mm, evaluation of the percentage similarity and spatial overlap following the DSC showed an average similarity of 67.7% between the two groups. The highest similarity was with orbito-facial prostheses (88.5%) and the lowest with facial plate prosthetics (28.7%).

    CONCLUSION: Although CS and OS pipelines are capable of producing templates which are aesthetically and volumetrically similar, there are slight comparative discrepancies in the landmark position and spatial overlap. This is dependent on the software, associated commands and experienced decision-making. CAD-based templates can be planned on current personal computers following appropriate decimation.

    Matched MeSH terms: Prostheses and Implants*
  8. Farook TH, Jamayet NB, Asif JA, Din AS, Mahyuddin MN, Alam MK
    Sci Rep, 2021 04 19;11(1):8469.
    PMID: 33875672 DOI: 10.1038/s41598-021-87240-9
    Palatal defects are rehabilitated by fabricating maxillofacial prostheses called obturators. The treatment incorporates taking deviously unpredictable impressions to facsimile the palatal defects into plaster casts for obturator fabrication in the dental laboratory. The casts are then digitally stored using expensive hardware to prevent physical damage or data loss and, when required, future obturators are digitally designed, and 3D printed. Our objective was to construct and validate an economic in-house smartphone-integrated stereophotogrammetry (SPINS) 3D scanner and to evaluate its accuracy in designing prosthetics using open source/free (OS/F) digital pipeline. Palatal defect models were scanned using SPINS and its accuracy was compared against the standard laser scanner for virtual area and volumetric parameters. SPINS derived 3D models were then used to design obturators by using (OS/F) software. The resultant obturators were virtually compared against standard medical software designs. There were no significant differences in any of the virtual parameters when evaluating the accuracy of both SPINS, as well as OS/F derived obturators. However, limitations in the design process resulted in minimal dissimilarities. With further improvements, SPINS based prosthetic rehabilitation could create a viable, low cost method for rural and developing health services to embrace maxillofacial record keeping and digitised prosthetic rehabilitation.
    Matched MeSH terms: Prostheses and Implants/statistics & numerical data*
  9. Hamidi MFFA, Harun WSW, Samykano M, Ghani SAC, Ghazalli Z, Ahmad F, et al.
    Mater Sci Eng C Mater Biol Appl, 2017 Sep 01;78:1263-1276.
    PMID: 28575965 DOI: 10.1016/j.msec.2017.05.016
    Biocompatible metals have been revolutionizing the biomedical field, predominantly in human implant applications, where these metals widely used as a substitute to or as function restoration of degenerated tissues or organs. Powder metallurgy techniques, in specific the metal injection moulding (MIM) process, have been employed for the fabrication of controlled porous structures used for dental and orthopaedic surgical implants. The porous metal implant allows bony tissue ingrowth on the implant surface, thereby enhancing fixation and recovery. This paper elaborates a systematic classification of various biocompatible metals from the aspect of MIM process as used in medical industries. In this study, three biocompatible metals are reviewed-stainless steels, cobalt alloys, and titanium alloys. The applications of MIM technology in biomedicine focusing primarily on the MIM process setting parameters discussed thoroughly. This paper should be of value to investigators who are interested in state of the art of metal powder metallurgy, particularly the MIM technology for biocompatible metal implant design and development.
    Matched MeSH terms: Prostheses and Implants
  10. Hannan MA, Hussein HA, Mutashar S, Samad SA, Hussain A
    Sensors (Basel), 2014;14(12):23843-70.
    PMID: 25615728 DOI: 10.3390/s141223843
    With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices.
    Matched MeSH terms: Prostheses and Implants*
  11. Hannan MA, Mutashar S, Samad SA, Hussain A
    Biomed Eng Online, 2014;13:79.
    PMID: 24950601 DOI: 10.1186/1475-925X-13-79
    The development of implanted devices is essential because of their direct effect on the lives and safety of humanity. This paper presents the current issues and challenges related to all methods used to harvest energy for implantable biomedical devices. The advantages, disadvantages, and future trends of each method are discussed. The concept of harvesting energy from environmental sources and human body motion for implantable devices has gained a new relevance. In this review, the harvesting kinetic, electromagnetic, thermal and infrared radiant energies are discussed. Current issues and challenges related to the typical applications of these methods for energy harvesting are illustrated. Suggestions and discussion of the progress of research on implantable devices are also provided. This review is expected to increase research efforts to develop the battery-less implantable devices with reduced over hole size, low power, high efficiency, high data rate, and improved reliability and feasibility. Based on current literature, we believe that the inductive coupling link is the suitable method to be used to power the battery-less devices. Therefore, in this study, the power efficiency of the inductive coupling method is validated by MATLAB based on suggested values. By further researching and improvements, in the future the implantable and portable medical devices are expected to be free of batteries.
    Matched MeSH terms: Prostheses and Implants*
  12. Hannan MA, Abbas SM, Samad SA, Hussain A
    Sensors (Basel), 2012;12(1):297-319.
    PMID: 22368470 DOI: 10.3390/s120100297
    Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices.
    Matched MeSH terms: Prostheses and Implants*
  13. Hashim NA, Abd Razak NA, Gholizadeh H, Abu Osman NA
    JMIR Serious Games, 2021 Feb 04;9(1):e17017.
    PMID: 33538698 DOI: 10.2196/17017
    BACKGROUND: Brain plasticity is an important factor in prosthesis usage. This plasticity helps with brain adaptation to learn new movement and coordination patterns needed to control a prosthetic hand. It can be achieved through repetitive muscle training that is usually very exhausting and often results in considerable reduction in patient motivation. Previous studies have shown that a playful concept in rehabilitation can increase patient engagement and perseverance.

    OBJECTIVE: This study investigated whether the inclusion of video games in the upper limb amputee rehabilitation protocol could have a beneficial impact for muscle preparation, coordination, and patient motivation among individuals who have undergone transradial upper limb amputation.

    METHODS: Ten participants, including five amputee participants and five able-bodied participants, were enrolled in 10 1-hour sessions within a 4-week rehabilitation program. In order to investigate the effects of the rehabilitation protocol used in this study, virtual reality box and block tests and electromyography (EMG) assessments were performed. Maximum voluntary contraction was measured before, immediately after, and 2 days after interacting with four different EMG-controlled video games. Participant motivation was assessed with the Intrinsic Motivation Inventory (IMI) questionnaire and user evaluation survey.

    RESULTS: Survey analysis showed that muscle strength and coordination increased at the end of training for all the participants. The results of Pearson correlation analysis indicated that there was a significant positive association between the training period and the box and block test score (r8=0.95, P

    Matched MeSH terms: Prostheses and Implants
  14. Hassan MH
    Med J Malaysia, 2004 May;59 Suppl B:164-5.
    PMID: 15468869
    There has been, and is still, concern about the high elastic modulus of Ti alloys compared to bone. Any reduction in the Young's modulus value of the implant is expected to enhance stress redistribution to the adjacent bone tissues, minimize stress shielding and eventually prolong device lifetime. Dynamic Monte Carlo simulation is used to predict the gradual reduction in Young's modulus values between the bulk of Ti alloys and the modified surface layers due to Ca ion implantation. The simulation can be used as a screening step when applying new alloys and/or coatings.
    Matched MeSH terms: Prostheses and Implants*
  15. Hawa Ismail, Ng, S.K., Hing, H.L., Normalawati Shamsudin, Ridzwan Hashim
    MyJurnal
    The calcareous rings of two species of local sea cucumbers, Stichopus hermanni Semper and Holothuria atra Jaeger, were located, dissected, exposed and recorded. The calcareous rings of both species each composed of ten plates knit together by connective tissues. The radial plate of H. atra was a square with a notch at the anterior part whereas in S. hermanni it was squarish consisting of 4 ridges in the anterior part with a notch at the posterior part. The interradial plates of both species were smaller than the radial plates. A ridge was present at the anterior part of the interradial plate in H. atra. In S. hermanii, the ridge at the anterior part of the interradial was thin and prominent. Under the scanning electron microscope the calcareous rings from the two species exhibited a mosaic of small, numerous spicules bound to each other.
    Matched MeSH terms: Prostheses and Implants
  16. Ho W, Lin Seow L, Musawi A
    J Clin Transl Res, 2018 May 28;4(1):70-74.
    PMID: 30873496
    Background: The purpose of the present study was to investigate the effect of different viscosities of polyvinyl siloxane (PVS) impression materials on the accuracy of the stone die produced.

    Methods: A three-unit bridge master model was fabricated using cold-cure acrylic resin. Four combinations of different viscosities of PVS impression materials - regular body (monophase) alone, light body with regular body, light body with heavy body, and light body with putty - were used to make an impression of the master model. Ten impressions from each group were taken and Type IV gypsum stone was used to generate the dies. The dies were measured at the inter-abutment distance, occlusogingival length, and shoulder width with a measuring microscope and were compared with the master model using one-way analysis of variance and Tukey (honest significant difference) test.

    Results: Differences were found for inter-abutment distance between the master model and the light body with regular body and light body with putty dies (both P < 0.02). A difference was found for shoulder width between the master model and the regular body alone die (P = 0.01). No differences were found for occlusogingival distance (all P > 0.08).

    Conclusion: Results suggested inter-abutment distance was most accurate when using a PVS light body combination. Occlusogingival length was accurate using any of the studied PVS combinations, and shoulder width was more accurate when using the regular body PVS.

    Relevance for patients: These results should be considered when choosing the viscosity of the PVS to use for producing impressions of high accuracy and fabricating a well-fitting fixed prosthesis.

    Matched MeSH terms: Prostheses and Implants
  17. Htun, T.H., Dublin, N., Parameswaran, M., Razack, A.H., Chua, C.B.
    JUMMEC, 2008;11(1):27-29.
    MyJurnal
    Priapism is a urological emergency. The treatment for ischaemic priapism is usually cavernosal aspiration with or without cavernosal irrigation. Some patients may need surgical intervention -the various shunt procedures. We report a 21-year-old man with priapism secondary to chronic myeloid leukemia who needed a combined medical and surgical management. He underwent a spongiocavernosal shunt as well as cytoreductive chemotherapy to achieve complete detumescence. Therefore, cytoreductive chemotherapy is an adjunct in difficult cult to treat priapism associated with chronic myeloid leukemia.
    Matched MeSH terms: Prostheses and Implants
  18. Inayat-Hussain SH, Rajab NF, Roslie H, Hussin AA, Ali AM, Annuar BO
    Med J Malaysia, 2004 May;59 Suppl B:176-7.
    PMID: 15468875
    Biomaterials intended for end-use application as bone-graft substitutes have to undergo safety evaluation. In this study, we investigated the in vitro cytotoxic effects especially to determine the mode of death of two hydroxyapatite compounds (HA2, HA3) which were synthesized locally. The methods used for cytotoxicity was the standard MTT assay whereas AO/PI staining was performed to determine the mode of cell death in HA treated L929 fibroblasts. Our results demonstrated that both HA2 and HA3 were not significantly cytotoxic as more than 75% cells after 72 hours treatment were viable. Furthermore, we found that the major mode of cell death in HA treated cells was apoptosis. In conclusion, our results demonstrated that these hydroxyapatite compounds are not cytotoxic where the mode of death was primarily via apoptosis.
    Matched MeSH terms: Prostheses and Implants*
  19. Ismail, S., Mohd Atan, K.A.
    MyJurnal
    This paper is concerned with the existence, types and the cardinality of the integral solutions for
    diophantine equation
    4 4 3
    x y z + = where x , y and z are integers. The aim of this paper was to
    develop methods to be used in finding all solutions to this equation. Results of the study show the
    existence of infinitely many solutions to this type of diophantine equation in the ring of integers
    for both cases, x y = and x y ¹ . For the case when x y = , the form of solutions is given by
    3 3 4
    ( , , ) (4 , 4 ,8 ) x y z n n n = , while for the case when x y ¹ , the form of solutions is given by
    3 1 3 1 4 1
    ( , , ) ( , , )
    k k k
    x y z un vn n
    - - -
    = . The main result obtained is a formulation of a generalized method to find
    all the solutions for both types of diophantine equations.
    Matched MeSH terms: Prostheses and Implants
  20. Jaganathan SK, Mohandas H, Sivakumar G, Kasi P, Sudheer T, Avineri Veetil S, et al.
    Biomed Res Int, 2014;2014:963149.
    PMID: 24955370 DOI: 10.1155/2014/963149
    Blood compatibility of metallocene polyethylene (mPE) was investigated after modifying the surface using hydrochloric acid. Contact angle of the mPE exposed to HCl poses a decrease in its value which indicates increasing wettability and better blood compatibility. Surface of mPE analyzed by using FTIR revealed no significant changes in its functional groups after treatment. Furthermore, scanning electron microscope images supported the increasing wettability through the modifications like pit formations and etching on the acid rendered surface. To evaluate the effect of acid treatment on the coagulation cascade, prothrombin time (PT) and activated partial thromboplastin time (APTT) were measured. Both PT and APTT were delayed significantly (P < 0.05) after 60 min exposure implying improved blood compatibility of the surfaces. Hemolysis assay of the treated surface showed a remarkable decrease in the percentage of lysis of red blood cells when compared with untreated surface. Moreover, platelet adhesion assay demonstrated that HCl exposed surfaces deter the attachment of platelets and thereby reduce the chances of activation of blood coagulation cascade. These results confirmed the enhanced blood compatibility of mPE after HCl exposure which can be utilized for cardiovascular implants like artificial vascular prostheses, implants, and various blood contacting devices.
    Matched MeSH terms: Prostheses and Implants/adverse effects; Prostheses and Implants/ultrastructure*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links