Displaying publications 21 - 40 of 54 in total

Abstract:
Sort:
  1. Hui KH, Ooi CS, Lim MH, Leong MS, Al-Obaidi SM
    PLoS One, 2017;12(12):e0189143.
    PMID: 29261689 DOI: 10.1371/journal.pone.0189143
    A major issue of machinery fault diagnosis using vibration signals is that it is over-reliant on personnel knowledge and experience in interpreting the signal. Thus, machine learning has been adapted for machinery fault diagnosis. The quantity and quality of the input features, however, influence the fault classification performance. Feature selection plays a vital role in selecting the most representative feature subset for the machine learning algorithm. In contrast, the trade-off relationship between capability when selecting the best feature subset and computational effort is inevitable in the wrapper-based feature selection (WFS) method. This paper proposes an improved WFS technique before integration with a support vector machine (SVM) model classifier as a complete fault diagnosis system for a rolling element bearing case study. The bearing vibration dataset made available by the Case Western Reserve University Bearing Data Centre was executed using the proposed WFS and its performance has been analysed and discussed. The results reveal that the proposed WFS secures the best feature subset with a lower computational effort by eliminating the redundancy of re-evaluation. The proposed WFS has therefore been found to be capable and efficient to carry out feature selection tasks.
    Matched MeSH terms: Resin Cements
  2. Samer MS, Faraz Q, Al-Dubai SAR, Vohra F, Abdullah H, Taiyeb-Ali TB, et al.
    Med Princ Pract, 2017;26(5):470-479.
    PMID: 28965115 DOI: 10.1159/000481864
    OBJECTIVES: The aim of this study was to determine the clinical outcomes and predictors of satisfaction in patients with lithium disilicate (LD) ceramic crowns.

    SUBJECTS AND METHODS: Clinical outcomes were assessed in 47 patients with 88 LD crowns using modified United States Public Health Service (USPHS) evaluation criteria and survival rates. The questionnaire for predictors included 3 aspects: (a) sociodemographic characteristics, (b) oral health habits (tooth brushing frequency, flossing frequency, and dental visits), and (c) satisfaction of the restorations (aesthetics, function, fit, cleansability, and chewing ability of the crowns, and overall satisfaction). Frequency distributions were computed using univariate and multivariate analysis. The Student t test and analysis of variance (ANOVA) were used to compare means across variables. Correlation analysis was done to assess the association between continuous variables.

    RESULTS: The age of crowns was 34.7 ± 9.7 months. The survival rate was 96.6% at 35.9 ± 9.2 months. There was a significant association between successful crown function and oral hygiene measures: tooth brushing (p˂ 0.001), dental visits (p = 0.006), and flossing (p = 0.009). A strong negative correlation was observed between aesthetic satisfaction (r = -0.717, p˂ 0.001) and chewing ability (r = -0.639, p˂ 0.001) with crown age. The linear regression model was significant for all predictors (p < 0.05) except overall satisfaction (p > 0.05).

    CONCLUSION: The LD crowns had long survival rates of 96.6% up to 35.9 ± 9.2 months and provided satisfactory clinical performance (low risk of failure). Oral hygiene habits such as brushing, flossing, and regular dental visits influenced patient satisfaction with LD crowns.

    Matched MeSH terms: Resin Cements
  3. Razak AA, Abu-Hassan MI, Al-Makramani BM, Al-Sanabani FA, Al-Shami IZ, Almansour HM
    J Contemp Dent Pract, 2016 Nov 01;17(11):920-925.
    PMID: 27965501
    AIM: The aim of this study was to evaluate the effect of surface treatments on shear bond strength (SBS) of Turkom-Cera (Turkom-Ceramic (M) Sdn. Bhd., Puchong, Malaysia) all-ceramic material cemented with resin cement Panavia-F (Kuraray Medical Inc., Okayama, Japan).

    MATERIALS AND METHODS: Forty Turkom-Cera ceramic disks (10 mm × 3 mm) were prepared and randomly divided into four groups. The disks were wet ground to 1000-grit and subjected to four surface treatments: (1) No treatment (Control), (2) sandblasting, (3) silane application, and (4) sandblasting + silane. The four groups of 10 specimens each were bonded with Panavia-F resin cement according to manufacturer's recommendations. The SBS was determined using the universal testing machine (Instron) at 0.5 mm/min crosshead speed. Failure modes were recorded and a qualitative micromorphologic examination of different surface treatments was performed. The data were analyzed using the one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests.

    RESULTS: The SBS of the control, sandblasting, silane, and sandblasting + silane groups were: 10.8 ± 1.5, 16.4 ± 3.4, 16.2 ± 2.5, and 19.1 ± 2.4 MPa respectively. According to the Tukey HSD test, only the mean SBS of the control group was significantly different from the other three groups. There was no significant difference between sandblasting, silane, and sandblasting + silane groups.

    CONCLUSION: In this study, the three surface treatments used improved the bond strength of resin cement to Turkom-Cera disks.

    CLINICAL SIGNIFICANCE: The surface treatments used in this study appeared to be suitable methods for the cementation of glass infiltrated all-ceramic restorations.

    Matched MeSH terms: Resin Cements/chemistry
  4. Santini A, Tiu SH, McGuinness NJ, Aldossary MS
    J Orthod, 2016 Sep;43(3):193-201.
    PMID: 27487476 DOI: 10.1080/14653125.2016.1205310
    OBJECTIVE: To evaluate the total light energy (TLE) transmission through three types of ceramic brackets with, bracket alone and with the addition of orthodontic adhesive, at different exposure durations, and to compare the microhardness of the cured adhesive.

    MATERIALS AND METHODS: Three different makes of ceramic brackets, Pure Sapphire(M), Clarity™ ADVANCED(P) and Dual Ceramic(P) were used. Eighteen specimens of each make were prepared and allocated to three groups (n = 6). MARC(®)-resin calibrator was used to determine the light curing unit (LCU) tip irradiance (mW/cm(2)) and TLE (J/cm(2)) transmitted through the ceramic brackets, and through ceramic bracket plus Transbond™ XT Light Cure Adhesive, for 5, 10 and 20 s. Vickers-hardness values at the bottom of the cured adhesive were determined. Statistical analysis used one-way analysis of variance (ANOVA); P = 0.05.

    RESULTS: TLE transmission rose significantly among all samples with increasing exposure durations. TLE reaching the adhesive- enamel interface was less than 10 J/cm(2), and through monocrystalline and polycrystalline ceramic brackets was significantly different (P 

    Matched MeSH terms: Resin Cements
  5. Reza F, Ibrahim NS
    Eur J Dent, 2015 2 26;9(1):74-79.
    PMID: 25713488 DOI: 10.4103/1305-7456.149646
    OBJECTIVE: Fiber post is cemented to a root canal to restore coronal tooth structure. This research aims to evaluate the effect of ultraviolet (UV) irradiation on bond strength of fiber post with resin cement.

    MATERIALS AND METHODS: A total of 40 of the two types of fiber posts, namely, FRC Prostec (FRC) and Fiber KOR (KOR), were used for the experiment. UV irradiation was applied on top of the fiber post surface for 0, 15, 20, and 30 min. The irradiated surface of the fiber posts (n = 5) were immediately bonded with resin cement (Rely X U200) after UV irradiation. Shear bond strength (SBS) MPa was measured, and the dislodged area of post surfaces was examined with scanning electron microscopes. Changes in surface roughness (Ra) of the FRC group after UV irradiation were observed (n = 3) using atomic force microscopy. Data of SBS were statistically analyzed using one-way analysis of variance, followed by multiple comparisons (P < 0.05).

    RESULTS: SBS was significantly higher for 20 min of UV irradiation of the FRC group while significantly higher SBS was observed with 15 min of UV irradiation of the KOR group. Resin cement was more evident (cohesive failure) on the dislodged post surface of the UV treated groups compared with the control. The surface roughness of the FRC post was Ra = 175.1 nm and Ra = 929.2 nm for the control and the 20 min group, respectively.

    CONCLUSIONS: Higher surface roughness of the UV irradiated group indicated formation of mechanical retention on the fiber post surface. Evidence of cohesive failure was observed which indicated higher SBS of fiber post with the UV irradiated group.

    Matched MeSH terms: Resin Cements
  6. Ab-Ghani Z, Jaafar W, Foo SF, Ariffin Z, Mohamad D
    J Conserv Dent, 2015 Sep-Oct;18(5):355-9.
    PMID: 26430296 DOI: 10.4103/0972-0707.164028
    To evaluate the shear bond strength between the dentin substrate and computer-aided design and computer-aided manufacturing feldspathic ceramic and nano resin ceramics blocks cemented with resin cement.
    Matched MeSH terms: Resin Cements
  7. Mohd Zainal Abidin R, Luddin N, Shamsuria Omar N, Mohamed Aly Ahmed H
    J Clin Pediatr Dent, 2015;39(3):235-40.
    PMID: 26208068 DOI: 10.17796/1053-4628-39.3.235
    To compare the cytotoxicity of conventional GIC and Resin Modified GIC (RMGIC) polymerized at 2 different times on stem cells from human exfoliated deciduous teeth (SHED).
    Matched MeSH terms: Resin Cements/toxicity*
  8. Mohamed Abdulmunem, Hadijah Binti Abdullah, Noor Hayaty Binti Abu Kasim, Ali Dabbagh
    Sains Malaysiana, 2015;44:1189-1194.
    The aim of this study was to investigate the simultaneous influence of various dental posts and cementation materials on the fracture resistance and failure mode of the endodontically-treated teeth. Sixty endodontically treated upper central incisors were randomly divided into two main groups, each consisted of three subgroups restored with titanium, fiber and stainless steel posts. The posts in the first and second groups were luted with zinc phosphate and composite resin cements, respectively. Composite cores were built-up over the specimens and then retained with nickel-chromium crowns. Specimens were thermocycled and then loaded at 135o until failures were observed. The obtained data of fracture resistances and failure modes were analyzed using Two-way ANOVA and the Chi-Square tests, respectively. The results showed that the zinc phosphate cement resulted in relatively higher fracture resistances. However, luting of dental posts with composite resin provided more restorable failures in endodontically-treated teeth. Moreover, the teeth restored by fiber posts exhibited desirable fracture resistances with more restorable failure modes, compared with those restored by titanium or stainless steel posts.
    Matched MeSH terms: Resin Cements
  9. Mustafa AA, Matinlinna JP, Saidin S, Kadir MR
    J Prosthet Dent, 2014 Dec;112(6):1498-506.
    PMID: 24993375 DOI: 10.1016/j.prosdent.2014.05.011
    STATEMENT OF PROBLEM: The inconsistency of dentin bonding affects retention and microleakage.

    PURPOSE: The purpose of this laboratory and finite element analysis study was to investigate the effects on the formation of a hybrid layer of an experimental silane coupling agent containing primer solutions composed of different percentages of hydroxyethyl methacrylate.

    MATERIAL AND METHODS: A total of 125 sound human premolars were restored in vitro. Simple class I cavities were formed on each tooth, followed by the application of different compositions of experimental silane primers (0%, 5%, 25%, and 50% of hydroxyethyl methacrylate), bonding agents, and dental composite resins. Bond strength tests and scanning electron microscopy analyses were performed. The laboratory experimental results were validated with finite element analysis to determine the pattern of stress distribution. Simulations were conducted by placing the restorative composite resin in a premolar tooth by imitating simple class I cavities. The laboratory and finite element analysis data were significantly different from each other, as determined by 1-way ANOVA. A post hoc analysis was conducted on the bond strength data to further clarify the effects of silane primers.

    RESULTS: The strongest bond of hybrid layer (16.96 MPa) was found in the primer with 25% hydroxyethyl methacrylate, suggesting a barely visible hybrid layer barrier. The control specimens without the application of the primer and the primer specimens with no hydroxyethyl methacrylate exhibited the lowest strength values (8.30 MPa and 11.78 MPa) with intermittent and low visibility of the hybrid layer. These results were supported by finite element analysis that suggested an evenly distributed stress on the model with 25% hydroxyethyl methacrylate.

    CONCLUSIONS: Different compositions of experimental silane primers affected the formation of the hybrid layer and its resulting bond strength.

    Matched MeSH terms: Resin Cements/chemistry
  10. Abdullah JM
    Malays J Med Sci, 2014 Dec;21(Spec Issue):1-5.
    PMID: 25941457
    The Malaysian Journal of Medical Sciences and the Orient Neuron Nexus have amalgated to publish a yearly special issue based on neuro- and brain sciences. This will hopefully improve the quality of peer-reviewed manuscripts in the field of fundamental, applied, and clinical neuroscience and brain science from Asian countries. One focus of the Universiti Sains Malaysia is to strengthen neuroscience and brain science, especially in the field of neuroinformatics.
    Matched MeSH terms: Resin Cements
  11. Elnafar AA, Alam MK, Hasan R
    J Orthod, 2014 Sep;41(3):201-7.
    PMID: 25143559 DOI: 10.1179/1465313314Y.0000000097
    The aim of this study was to assess the effects of four enamel preparation techniques on shear bond strength (SBS) of brackets bonded with a resin-modified glass ionomer cement (RMGIC). Adhesive Remnant Index (ARI) and enamel surface roughness (Ra) were also investigated after cement removal.
    Matched MeSH terms: Resin Cements/chemistry*
  12. SH, Ku, YS, Tan, Yahya NA
    Ann Dent, 2014;21(1):25-32.
    MyJurnal
    The study aimed to evaluate the quality of the hybrid
    layer form by three different adhesive systems. Class V
    cavities were prepared on the buccal surface of fourty
    extracted human premolars. The prepared teeth were
    randomly assigned into four groups according to the
    adhesive system and application mode. The systems
    were: Optibond S (OS, total-etch); Optibond Versa (OV,
    two-bottles, self-etch); Single Bond Universal (SBU,
    one-bottle, self-etch) and Single Bond Universal with
    etchant (SBU + etchant). All cavities were restored with
    composite (Filtek Z350XT). The samples were sectioned,
    polished and pretreated to remove minerals, protein
    and water prior to SEM evaluation. From the images,
    thickness of the hybrid layers was measured. Present of
    resin tags and adaptation failure were also recorded. The
    data obtained were analyzed using ANOVA, Dunnett’s
    T3, Kruskal-Wallis and Mann-Whitney tests. OS group
    showed the highest average hybrid layer thickness (4.34
    µm), followed by SBU + etchant (3.06 µm), OV (1.91 µm)
    and SBU (0.95 µm). Both adhesive and cohesive failures
    were observed in SBU group. Present of prominent resin
    tags were seen in both OS and OV groups. In conclusion,
    all the investigated adhesive systems were able to perform
    distinguishable actions as shown in micro-morphological
    alteration and hybrid layer thickness. Two-bottles, selfetch
    adhesive (OV) was proven to produce negligible
    adaptation failure compared to other adhesive systems in
    the present study. Combined all-in-one adhesive (SBU)
    was found to render a superior bonding performance in
    total-etch mode comparing to self-etch mode.
    Matched MeSH terms: Resin Cements
  13. Faisal Ismail Bahnasi, Nagham Mohammed Abdullah, Mohamed Ibrahim Abu-Hassan
    Compendium of Oral Science, 2014;1(1):24-29.
    MyJurnal
    Objectives: To evaluate the effect of light-cure devices and curing times on the shear bond strength (SBS) of orthodontic brackets.

    Material and Methods: 60-extracted human premolars were divided into 6-groups of 10-teeth each and bonded with stainless-steel brackets by using 3M Unitek Transbond XT composite. Specimens were cured with halogen, LED and plasma arc lights with two different times for each. The specimens were subjected to shear force till debond with a crosshead speed of 1mm/min and tested after 5min. The stress was calculated and data were subjected to statistical analysis.

    Results: one-way ANOVA and Dunnett T3 post hoc comparison test were used. There were no significant differences between the 6 groups (p < 0.05).

    Conclusions: all curing light methods with loading force after 5 min achieved SBS more than the normal range; therefore, arch wire can be inserted at the same visit using any of tested curing light device or curing time.
    Matched MeSH terms: Resin Cements
  14. Udin, W. S., Ahmad, A., Ismail, Z.
    MyJurnal
    In recent years image acquisition in close range photogrammetry relies on digital sensors such as digital cameras, video cameras, CCD cameras etc that are not specifically designed for photogrammetry. This study is performed to evaluate the compatibility of the digital metric camera and non-metric camera for the purpose of mapping meandering flume, using close range photogrammetric technique and further, to determine the accuracy that could be achieved using such a technique. The meandering flume provides an opportunity to conduct an experimental study in a controlled environment. In this study, the digital images of the whole meandering flume were acquired using a compact digital camera - Nikon Coolpix S560, a Single Lens Reflex (SLR) Nikon D60 and also a metric digital camera Rollei D30. A series of digital images were acquired to cover the whole meandering flume. Secondary data of ground control points (GCP) and check points (CP), established using the Total Station technique, was used. The digital camera was calibrated and the recovered camera calibration parameters were then used in the processing of digital images. In processing the digital images, digital photogrammetric software was used for processes such as aerial triangulation, stereo compilation, generation of digital elevation model (DEM) and generation of orthophoto. The whole process was successfully performed and the output produced in the form of orthophoto. The research output is then evaluated for planimetry and vertical accuracy using root mean square error (RMSE). Based on the analysis, sub-meter accuracy is obtained. It can be concluded that the differences between the different types of digital camera are small . As a conclusion, this study proves that close range photogrammetry technique can be used for mapping meandering flume using both the metric digital camera and non-metric digital camera.
    Matched MeSH terms: Resin Cements
  15. Tapsir Z, Aly Ahmed HM, Luddin N, Husein A
    J Contemp Dent Pract, 2013 Jan 1;14(1):47-50.
    PMID: 23579892
    To evaluate and compare the microleakage of various restorative materials used as coronal barriers between endodontic appointments.
    Matched MeSH terms: Resin Cements/chemistry
  16. Alireza Jahani, Masrah Azrifah Azmi Murad, Md. Nasir Sulaiman, Hasan Selamat
    MyJurnal
    Similarity measurement is a critical component in any case-based reasoning (CBR) system. CBR is
    a superior technique for solving new problems based on previous experiences. Main assumption in
    CBR relies on the hypothesis that states similar problems should have similar solutions. This paper
    describes a comparative analysis on several commonly used similarity measures (Canberra, Clark, and Normalized Euclidean distance) in retrieving phase of the case-based reasoning approach to facilitate supplier selection. In addition, the proposed agent-based supplier selection framework was designed to use customer’s defined weights to evaluate the price, volume, quality grade, and delivery date of supply materials, and also provide them with alternative products which are closest to their first order if it was out of stock. Finally, based on the proposed framework, a numerical example of the used approach is illustrated.
    Matched MeSH terms: Resin Cements
  17. Reza F, Lim SP
    J Conserv Dent, 2012 Apr;15(2):123-6.
    PMID: 22557808 DOI: 10.4103/0972-0707.94576
    To compare push-out bond strength between self-cured and dual-cured resin cement using a titanium post.
    Matched MeSH terms: Resin Cements
  18. Baig MR, Gunaseelan R
    J Oral Implantol, 2012 Apr;38(2):149-53.
    PMID: 20932151 DOI: 10.1563/AAID-JOI-D-09-00089
    Passive fit of a long-span screw-retained implant prosthesis is an important criteria for the success of the restoration. This article describes a technique for fabricating a ceramometal implant fixed dental prosthesis (FDP) for a long-span partially edentulous situation by altering the conventional screw-retained design. The possibility of a passive fit is maximized by intraoral luting of the cast frame to milled abutments, and the potential framework distortion during fabrication is compensated to a major extent. Retrievability is ensured by screw retention of the prosthesis to the implants. Compared with conventional porcelain fused to metal screw-retained FDP, this prosthesis is relatively inexpensive to fabricate.
    Matched MeSH terms: Resin Cements/chemistry
  19. Noor Sam A, Asma A
    Sains Malaysiana, 2012;41:1051-1056.
    A good adhesive is an important factor to consider in orthodontic bonding. Frequent bracket failure prolongs treatment duration and causes inconvenience to patient and operator. This study aimed to compare the effectiveness of two bonding agents, i.e. the self etching primer (SEP) and the conventional etch and bond (CEB) by monitoring the incidence, time and
    sites of bracket failure. Eighty orthodontic patients were recruited after informed consent were obtained. A randomized split mouth technique was used where one side was bonded with CEB agent, while the other side was bonded using SEP agent. All bonded brackets were examined every 4 weeks for 20 months. Incidence of bracket failure was noted and
    comparison between the two groups was done using paired t-test. Time and frequent site of failure were also assessed. Out of 1314 brackets, only 33 brackets were debonded with 16 from SEP group and 17 from CEB group which statistically insignificant (p>0.05). Almost 55% of bracket failure occurred during the first 3 months after bonding for both adhesives
    with lower premolars was most the frequent site to fail in both adhesives (39.4%). Bracket bonded on the left side failed significantly compared to the right side. In conclusion, both self-etching primer and conventional acid-etch bonding agents are equally effective in retaining brackets clinically. Bracket failure mostly occurres during the first 3 months after bonding. The premolar brackets and the left side are mostly debonded when compared to other sites.
    Matched MeSH terms: Resin Cements
  20. Lim, Siau Peng, Fazal Reza, Zaihan Ariffin
    MyJurnal
    The purpose of this study was to evaluate hardness (indicator for polymerization) and thickness of two types of resin cement at coronal, middle and apical level of tooth root canal. Ten extracted maxillary incisors were instrumented and post space was prepared for cementation of titanium post. Samples were divided into two groups and each group was cemented either of the two types of resin cements; Panavia F [dual-cured (PF)] and Rely X Luting 2 [self-cured (RL)]. The teeth were longitudinally sectioned; hardness and thickness was measured using Vickers hardness tester and a microscope (Leica DMLM). SEM observations along the cement line at the 3 different root levels were performed. Statistical analysis was performed to test significance of differences in hardness and thickness of the two types of cement (t-test; p= 0.05) and at different levels of the same type (one-way ANOVA followed by multiple comparison; p= 0.05). Significant difference of hardness was found at the apical level between the two groups and between the coronal and apical level of PF (p0.05). Moreover, voids were more obvious within the dual-cured group of cement. Dual-cured resin cement was found to be less polymerized than self-cured type at apical level. Increased thicknesses of resin cements in comparison to post space size were observed in both groups. Use of metallic post with resin cements needs further evaluation.
    Matched MeSH terms: Resin Cements
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links