METHODS: A total of 301 older adults (⩾60 years of age) participating in a study on aging had their hearing tested using pure-tone audiometry. Self-perceived hearing loss was assessed using a single question. Sociodemographic profile, otologic history, and general cognitive status were also obtained.
RESULTS: A single question had low sensitivity in detecting actual hearing loss: 31.3% for 4-frequency average > 25 dBHL and 48.8% for 4-frequency average > 40 dBHL. Besides hearing level, history of otorrhea and tinnitus were factors that were associated with self-perceived hearing loss among older adults with at least mild hearing loss. Hearing-help-seeking behavior was not associated with any of the tested variables. The hearing aid adoption rate was 2.7% and 7.3% among participants with 4-frequency averages > 25 dBHL and > 40 dBHL, respectively.
CONCLUSION: The underestimation of hearing loss in the majority of older adults in this study poses a potential barrier to hearing loss intervention.
OBJECTIVE: This study aims to investigate the feasibility of EEG measurements as an objective indicator for the identification of tinnitus-associated neural activities.
METHODS: To reduce heterogeneity, participants served as their own control using residual inhibition (RI) to modulate the tinnitus perception in a within-subject EEG study design with a tinnitus group. In addition, comparison with a nontinnitus control group allowed for a between-subjects comparison. We will apply RI stimulation to generate tinnitus and nontinnitus conditions in the same subject. Furthermore, high-frequency audiometry (up to 13 kHz) and tinnitometry will be performed.
RESULTS: This work was funded by the Infrastructure Grant of the University of Bern, Bern, Switzerland and Bernafon AG, Bern, Switzerland. Enrollment for the study described in this protocol commenced in February 2018. Data analysis is currently under way and the first results are expected to be submitted for publication in 2019.
CONCLUSIONS: This study design helps in comparing the neural activity between conditions in the same individual, thereby addressing a notable limitation of previous EEG tinnitus studies. In addition, the high-frequency assessment will help to analyze and classify tinnitus symptoms beyond the conventional clinical standard.
INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/12270.
METHODS/DESIGN: The CROSSSD study adopts an international two-round online modified Delphi survey followed by a stakeholder consensus meeting to identify a patient-centred core outcome domain set for SSD based on what is considered critical and important for assessing whether an intervention for SSD has worked.
DISCUSSION: The resulting core outcome domain set will act as a minimum standard for reporting in future clinical trials and could have further applications in guiding the use of outcome measures in clinical practice. Standardisation will facilitate comparison of research findings.
CLINICAL CASE: A 56-year-old Chinese woman, an active smoker, presented with a hearing deficit, persistent tinnitus and nasal congestion. Examination and investigations revealed the presence of a mass in the nasopharynx. Tissue biopsy revealed nasopharyngeal carcinoma. However, the Epstein-Barr virus was not tested. She was counseled for chemotherapy, but refused and was subsequently lost to follow up. She presented one year later with right eye ptosis associated with progressive worsening of diplopia and blurring of vision. Examination revealed multiple (second, third, fourth and sixth) cranial nerve involvement. Systemic examination and investigations revealed cervical lymphadenopathy and liver metastasis. Repeated imaging showed that the mass had invaded the base of the skull, cavernous sinus and orbital apices. Pulse dosing of corticosteroid therapy was commenced, resulting in dramatic improvement of vision.
CONCLUSION: Optic neuropathy may be the presenting sign of NPC. Corticosteroid therapy can offer immediate visual improvement.