Displaying publications 41 - 60 of 249 in total

Abstract:
Sort:
  1. Gallagher MT, Cupples G, Ooi EH, Kirkman-Brown JC, Smith DJ
    Hum Reprod, 2019 07 08;34(7):1173-1185.
    PMID: 31170729 DOI: 10.1093/humrep/dez056
    STUDY QUESTION: Can flagellar analyses be scaled up to provide automated tracking of motile sperm, and does knowledge of the flagellar waveform provide new insight not provided by routine head tracking?

    SUMMARY ANSWER: High-throughput flagellar waveform tracking and analysis enable measurement of experimentally intractable quantities such as energy dissipation, disturbance of the surrounding medium and viscous stresses, which are not possible by tracking the sperm head alone.

    WHAT IS KNOWN ALREADY: The clinical gold standard for sperm motility analysis comprises a manual analysis by a trained professional, with existing automated sperm diagnostics [computer-aided sperm analysis (CASA)] relying on tracking the sperm head and extrapolating measures. It is not currently possible with either of these approaches to track the sperm flagellar waveform for large numbers of cells in order to unlock the potential wealth of information enclosed within.

    STUDY DESIGN, SIZE, DURATION: The software tool in this manuscript has been developed to enable high-throughput, repeatable, accurate and verifiable analysis of the sperm flagellar beat.

    PARTICIPANTS/MATERIALS, SETTING, METHODS: Using the software tool [Flagellar Analysis and Sperm Tracking (FAST)] described in this manuscript, we have analysed 176 experimental microscopy videos and have tracked the head and flagellum of 205 progressive cells in diluted semen (DSM), 119 progressive cells in a high-viscosity medium (HVM) and 42 stuck cells in a low-viscosity medium. Unscreened donors were recruited at Birmingham Women's and Children's NHS Foundation Trust after giving informed consent.

    MAIN RESULTS AND THE ROLE OF CHANCE: We describe fully automated tracking and analysis of flagellar movement for large cell numbers. The analysis is demonstrated on freely motile cells in low- and high-viscosity fluids and validated on published data of tethered cells undergoing pharmacological hyperactivation. Direct analysis of the flagellar beat reveals that the CASA measure 'beat cross frequency' does not measure beat frequency; attempting to fit a straight line between the two measures gives ${\mathrm{R}}^2$ values of 0.042 and 0.00054 for cells in DSM and HVM, respectively. A new measurement, track centroid speed, is validated as an accurate differentiator of progressive motility. Coupled with fluid mechanics codes, waveform data enable extraction of experimentally intractable quantities such as energy dissipation, disturbance of the surrounding medium and viscous stresses. We provide a powerful and accessible research tool, enabling connection of the mechanical activity of the sperm to its motility and effect on its environment.

    LARGE SCALE DATA: The FAST software package and all documentation can be downloaded from www.flagellarCapture.com.

    LIMITATIONS, REASONS FOR CAUTION: The FAST software package has only been tested for use with negative phase contrast microscopy. Other imaging modalities, with bright cells on a dark background, have not been tested but may work. FAST is not designed to analyse raw semen; it is specifically for precise analysis of flagellar kinematics, as that is the promising area for computer use. Flagellar capture will always require that cells are at a dilution where their paths do not frequently cross.

    WIDER IMPLICATIONS OF THE FINDINGS: Combining tracked flagella with mathematical modelling has the potential to reveal new mechanistic insight. By providing the capability as a free-to-use software package, we hope that this ability to accurately quantify the flagellar waveform in large populations of motile cells will enable an abundant array of diagnostic, toxicological and therapeutic possibilities, as well as creating new opportunities for assessing and treating male subfertility.

    STUDY FUNDING/COMPETING INTEREST(S): M.T.G., G.C., J.C.K-B. and D.J.S. gratefully acknowledge funding from the Engineering and Physical Sciences Research Council, Healthcare Technologies Challenge Award (Rapid Sperm Capture EP/N021096/1). J.C.K-B. is funded by a National Institute of Health Research (NIHR) and Health Education England, Senior Clinical Lectureship Grant: The role of the human sperm in healthy live birth (NIHRDH-HCS SCL-2014-05-001). This article presents independent research funded in part by the NIHR and Health Education England. The views expressed are those of the authors and not necessarily those of the NHS, the NIHR or the Department of Health. The data for experimental set (2) were funded through a Wellcome Trust-University of Birmingham Value in People Fellowship Bridging Award (E.H.O.).The authors declare no competing interests.

    Matched MeSH terms: Biomechanical Phenomena
  2. Wan Hassan WN, Stephenson PA, Waddington RJ, Sloan AJ
    J Dent, 2012 May;40(5):406-15.
    PMID: 22342686 DOI: 10.1016/j.jdent.2012.02.002
    Root resorption is a ubiquitous although undesirable sequela to orthodontic treatment. Current methods to investigate the pathophysiology have certain limitations. In pursuit to understand and develop treatment modalities for orthodontically induced root resorption, the ability to manipulate cells within their natural extracellular matrix in a three dimensional organotypic model is invaluable. The study aimed to develop a laboratory-based organotypic model to investigate the effect of orthodontic forces on the periodontium.
    Matched MeSH terms: Biomechanical Phenomena
  3. Ibrahim N', Khamis MF, Mod Yunoh MF, Abdullah S, Mohamed N, Shuid AN
    PLoS One, 2014;9(12):e115595.
    PMID: 25526611 DOI: 10.1371/journal.pone.0115595
    Osteoporosis is becoming a major health problem that is associated with increased fracture risk. Previous studies have shown that osteoporosis could delay fracture healing. Although there are potential agents available to promote fracture healing of osteoporotic bone such as statins and tocotrienol, studies on direct delivery of these agents to the fracture site are limited. This study was designed to investigate the effects of two potential agents, lovastatin and tocotrienol using targeted drug delivery system on fracture healing of postmenopausal osteoporosis rats. The fracture healing was evaluated using micro CT and biomechanical parameters. Forty-eight Sprague-Dawley female rats were divided into 6 groups. The first group was sham-operated (SO), while the others were ovariectomized (OVx). After two months, the right tibiae of all rats were fractured at metaphysis region using pulsed ultrasound and were fixed with plates and screws. The SO and OVxC groups were given two single injections of lovastatin and tocotrienol carriers. The estrogen group (OVx+EST) was given daily oral gavages of Premarin (64.5 µg/kg). The Lovastatin treatment group (OVx+Lov) was given a single injection of 750 µg/kg lovastatin particles. The tocotrienol group (OVx+TT) was given a single injection of 60 mg/kg tocotrienol particles. The combination treatment group (OVx+Lov+TT) was given two single injections of 750 µg/kg lovastatin particles and 60 mg/kg tocotrienol particles. After 4 weeks of treatment, the fractured tibiae were dissected out for micro-CT and biomechanical assessments. The combined treatment group (OVx+Lov+TT) showed significantly higher callus volume and callus strength than the OVxC group (p<0.05). Both the OVx+Lov and OVx+TT groups showed significantly higher callus strength than the OVxC group (p<0.05), but not for callus volume. In conclusion, combined lovastatin and tocotrienol may promote better fracture healing of osteoporotic bone.
    Matched MeSH terms: Biomechanical Phenomena
  4. Mohd Effendy N, Abdullah S, Yunoh MF, Shuid AN
    BMC Complement Altern Med, 2015 Mar 12;15:58.
    PMID: 25887391 DOI: 10.1186/s12906-015-0567-x
    BACKGROUND: Post-menopausal osteoporosis has long been treated and prevented by estrogen replacement therapy (ERT). Despite its effectiveness, ERT is associated with serious adverse effects. Labisia pumila var. alata (LP) is a herb with potential as an alternative agent to ERT due to its phytoestrogenic, antioxidative and anti-inflammatory effects on bone. This study aimed to determine the effects of LP supplementation on bone biomechanical strength of postmenopausal osteoporosis rat model.

    METHODS: Ninety-six female Sprague-Dawley rats aged 4 to 5 months old were randomly divided into six groups; six rats in the baseline group (BL) and eighteen rats in each group of; Sham- operated (Sham), ovariectomised control (OVXC) and ovariectomised with daily oral gavages of Premarin at 64.5 μg/kg (ERT), LP at 20 mg/kg (LP20) and LP at 100 mg/kg (LP100) respectively. These groups were subdivided into three, six and nine weeks of treatment periods. Rats in BL group were euthanized before the start of the study, while other rats were euthanized after completion of their treatments. Femora were dissected out for biomechanical strength analysis using Instron Universal Model 5848 Micro Tester.

    RESULTS: OVXC group showed deterioration in the bone biomechanical strength with time. Both ERT and LP supplemented rats showed improvements in bone strength parameters such as maximum load, displacement, stiffness, stress, and Young Modulus. The most improved bone strength was seen in rats given LP at the dose of 100 mg/kg for nine weeks.

    CONCLUSION: LP supplementation at 100 mg/kg was more effective than ERT in reversing ovariectomy-induced bone biomechanical changes.
    Matched MeSH terms: Biomechanical Phenomena
  5. Amirah Zahiran, Fara Liana Zainuddin, Shazlin Shaharudin
    MyJurnal
    Introduction: In this study, we evaluated the kinematics of lower limb during early and late phases of 2km time trial on stationary rowing ergometer among Malaysian male rowers. Methods: Seventeen national-level rowers voluntari- ly participated. Three dimensional lower limb kinematics data were collected to represent the first 400 m (i.e., early) and the last 400m (i.e., late) phases of 2km time trial on a stationary ergometer. The kinematics data at sagittal, frontal and transverse planes of dominant leg during catch and finish positions were compared across early and late phases of the time trial using paired T-test. Results: The kinematics of lower limb joints at three planes were not significantly different during early versus late phases of 2km time trial among male senior rowers except for hip flexion at finish (p=0.411), ankle rotation at catch (p=0.779) and ankle abduction at finish (p=0.677). Conclusion: Lower limb kine- matics particularly the hip flexion, ankle rotation and ankle abduction may change across early and late phases of 2km time trial due to fatigue. Coaches and rowers should monitor these motions during fatiguing rowing piece and develop necessary injury prevention measures.
    Matched MeSH terms: Biomechanical Phenomena
  6. Mohd Azhar N, Affandi NF, Mail MSZ, Shaharudin S
    J Taibah Univ Med Sci, 2019 Aug;14(4):343-349.
    PMID: 31488966 DOI: 10.1016/j.jtumed.2019.06.007
    Objectives: The purpose of this study was to investigate the effect of transverse plane foot position on lower limb kinematics during a single leg squat.

    Methods: This was a cross-sectional study conducted among highly-trained male athletes. Only participants who showed normal knee valgus during a drop landing screening test were recruited. Twelve junior athletes performed single leg squats while maintaining a knee flexion angle of 60°. The squats were executed in three foot positions: neutral (0°), adduction (-10°), and abduction (+10°). Three-dimensional motion analysis was used to capture the lower extremity kinematics of the participants' preferred limb. The hip and knee kinematics in the sagittal, frontal, and transverse planes during squatting were compared across the three foot positions using one-way ANOVA.

    Results: The participants showed a normal range of dynamic knee valgus (5.3°±1.6). No statistically significant differences were observed in hip flexion (p = 0.322), adduction (p = 0.834), or internal rotation (p = 0.967) across different foot positions. Similarly, no statistically significant differences were observed in knee flexion (p = 0.489), adduction (p = 0.822), or internal rotation (p = 0.971) across different foot positions.

    Conclusion: Small changes in transverse plane foot position do not affect lower extremity kinematics during single leg squat in highly trained adolescent males with normal dynamic knee valgus. Our findings may provide guidance on safer techniques for landing, pivoting, and cutting during training and game situations.

    Matched MeSH terms: Biomechanical Phenomena
  7. Abd Rahman NA, Li S, Schmid S, Shaharudin S
    Phys Ther Sport, 2023 Jan;59:60-72.
    PMID: 36516512 DOI: 10.1016/j.ptsp.2022.11.011
    Low back pain (LBP) can result in increased direct medical and non-medical costs to patients, employers, and health care providers. This systematic review aimed to provide a better understanding of the biomechanical factors associated with chronic non-specific LBP in adults. SCOPUS, ScienceDirect, MEDLINE, and Web of Science databases were searched. In total, 26 studies were included and significant differences were noted between healthy controls and LBP patients in various motion. Biomechanical factors among adults with non-specific LBP were altered and differed as compared to healthy controls in various motion might be to compensate the pain during those motions. This review highlighted the biomechanical differences across those with non-specific LBP and healthy adults. Both groups showed a similar level of pain during functional tasks but LBP patients suffered from a moderate level of disability. Future studies should not rely on questionnaire-based pain scale only. The biomechanical factors summarized in this review can be used to diagnose non-specific LBP accurately, and as modifiable targets for exercise-based intervention.
    Matched MeSH terms: Biomechanical Phenomena
  8. Noroozi S, Ong ZC, Khoo SY, Aslani N, Sewell P
    Prosthet Orthot Int, 2019 Feb;43(1):62-70.
    PMID: 30051756 DOI: 10.1177/0309364618789449
    BACKGROUND:: The current method of prescribing composite running-specific energy-storing-and-returning feet is subjective and is based only on the amputee's static body weight/mass.

    OBJECTIVES:: The aim was to investigate their dynamic characteristics and create a relationship between these dynamic data and the prescription of foot.

    STUDY DESIGN:: Experimental Assessment.

    METHODS:: This article presents the modal analysis results of the full range of Össur Flex-Run™ running feet that are commercially available (1LO-9LO) using experimental modal analysis technique under a constant mass at 53 kg and boundary condition.

    RESULTS:: It was shown that both the undamped natural frequency and stiffness increase linearly from the lowest to the highest stiffness category of foot which allows for a more informed prescription of foot when tuning to a matched natural frequency. The low damping characteristics determined experimentally that ranged between 1.5% and 2.0% indicates that the feet require less input energy to maintain the steady-state cyclic motion before take-off from the ground. An analysis of the mode shapes also showed a unique design feature of these feet that is hypothesised to enhance their performance.

    CONCLUSION:: A better understanding of dynamic characteristics of the feet can help tune the feet to the user's requirements in promoting a better gait performance.

    CLINICAL RELEVANCE: The dynamic data determined from this study are needed to better inform the amputees in predicting the natural frequency of the foot prescribed. The amputees can intuitively tune the cyclic body rhythm during walking or running to match with the natural frequency. This could eventually promote a better gait performance.

    Matched MeSH terms: Biomechanical Phenomena
  9. Gouwanda D, Senanayake SM
    J Med Eng Technol, 2011 Nov;35(8):432-40.
    PMID: 22074136 DOI: 10.3109/03091902.2011.627080
    A real-time gait monitoring system that incorporates an immediate and periodical assessment of gait asymmetry is described. This system was designed for gait analysis and rehabilitation of patients with pathologic gait. It employs wireless gyroscopes to measure the angular rate of the thigh and shank in real time. Cross-correlation of the lower extremity (Cc(norm)), and normalized Symmetry Index (SI(norm)) are implemented as new approaches to periodically determine the gait asymmetry in each gait cycle. Cc(norm) evaluates the signal patterns measured by wireless gyroscopes in each gait cycle. SI(norm) determines the movement differences between the left and right limb. An experimental study was conducted to examine the viability of these methods. Artificial asymmetrical gait was simulated by placing a load on one side of the limbs. Results showed that there were significant differences between the normal gait and asymmetrical gait (p < 0.01). They also indicated that the system worked well in periodically assessing the gait asymmetry.
    Matched MeSH terms: Biomechanical Phenomena
  10. Gouwanda D, Senanayake SM
    J Biomech, 2011 Mar 15;44(5):972-8.
    PMID: 21306714 DOI: 10.1016/j.jbiomech.2010.12.013
    Injury to a lower limb may disrupt natural walking and cause asymmetrical gait, therefore assessing the gait asymmetry has become one of the important procedures in gait analysis. This paper proposes the use of wireless gyroscopes as a new instrument to determine gait asymmetry. It also introduces two novel approaches: normalized cross-correlations (Cc(norm)) and Normalized Symmetry Index (SI(norm)). Cc(norm) evaluates the waveform patterns generated by the lower limb in each gait cycle. SI(norm) provides indications on the timing and magnitude of the bilateral differences between the limbs while addressing the drawbacks of the conventional methods. One-way ANOVA test reveals that Cc(norm) can be considered as single value indicator that determines the gait asymmetry (p<0.01). The experiment results showed that SI(norm) in asymmetrical gait were different from normal gait. SI(norm) in asymmetrical gait were found to be approximately 20% greater than SI(norm) in normal gait during pre-swing and initial swing.
    Matched MeSH terms: Biomechanical Phenomena
  11. Savall J, Ho ET, Huang C, Maxey JR, Schnitzer MJ
    Nat. Methods, 2015 Jul;12(7):657-60.
    PMID: 26005812 DOI: 10.1038/nmeth.3410
    We present a robot that enables high-content studies of alert adult Drosophila by combining operations including gentle picking; translations and rotations; characterizations of fly phenotypes and behaviors; microdissection; or release. To illustrate, we assessed fly morphology, tracked odor-evoked locomotion, sorted flies by sex, and dissected the cuticle to image neural activity. The robot's tireless capacity for precise manipulations enables a scalable platform for screening flies' complex attributes and behavioral patterns.
    Matched MeSH terms: Biomechanical Phenomena
  12. Burrows M, Ghosh A, Sutton GP, Yeshwanth HM, Rogers SM, Sane SP
    J Exp Biol, 2021 12 01;224(23).
    PMID: 34755862 DOI: 10.1242/jeb.243361
    Lantern bugs are amongst the largest of the jumping hemipteran bugs, with body lengths reaching 44 mm and masses reaching 0.7 g. They are up to 600 times heavier than smaller hemipterans that jump powerfully using catapult mechanisms to store energy. Does a similar mechanism also propel jumping in these much larger insects? The jumping performance of two species of lantern bugs (Hemiptera, Auchenorrhyncha, family Fulgoridae) from India and Malaysia was therefore analysed from high-speed videos. The kinematics showed that jumps were propelled by rapid and synchronous movements of both hind legs, with their trochantera moving first. The hind legs were 20-40% longer than the front legs, which was attributable to longer tibiae. It took 5-6 ms to accelerate to take-off velocities reaching 4.65 m s-1 in the best jumps by female Kalidasa lanata. During these jumps, adults experienced an acceleration of 77 g, required an energy expenditure of 4800 μJ and a power output of 900 mW, and exerted a force of 400 mN. The required power output of the thoracic jumping muscles was 21,000 W kg-1, 40 times greater than the maximum active contractile limit of muscle. Such a jumping performance therefore required a power amplification mechanism with energy storage in advance of the movement, as in their smaller relatives. These large lantern bugs are near isometrically scaled-up versions of their smaller relatives, still achieve comparable, if not higher, take-off velocities, and outperform other large jumping insects such as grasshoppers.
    Matched MeSH terms: Biomechanical Phenomena
  13. Mohamed SH, Arifin A, Mohd Ishak ZA, Nizam A, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:25-6.
    PMID: 15468801
    The aim of this study was to evaluate the effect of powder-to-liquid ratio on the glass transition temperature (Tg) and the tensile properties of denture base material prepared from poly (methyl methacrylate) (PMMA) and hydroxyapatite (HA) previously treated with 3-trimethoxysilylpropyl methacrylate (gamma-MPS). Specimens for mechanical testing were prepared by adding composites powder (PMMA, BPO and HA) to the monomer (MMA and EGDMA) followed by hand mixing as in dental laboratory description usage. The glass transition temperature was studied by using differential scanning calorimetry (DSC). It was observed that the tensile properties and the Tg were affected by the powder-to-liquid ratio. The mechanical characterization of the materials were performed by using single edge notch-tension (SEN-T) specimens; the fracture toughness was slightly higher in formulation which contained HA filler compared to commercial denture base material.
    Matched MeSH terms: Biomechanical Phenomena
  14. Azizan NA, Basaruddin KS, Salleh AF
    Appl Bionics Biomech, 2018;2018:5156348.
    PMID: 30116295 DOI: 10.1155/2018/5156348
    Various studies have examined body posture stability, including postural sway and associated biomechanical parameters, to assess the severity effects of leg length discrepancy (LLD). However, various viewpoints have been articulated on the results of these studies because of certain drawbacks in the comprehensive analysis of the effect of variations in LLD magnitude. Therefore, this systematic review was performed to help focus on the current findings to help identify which biomechanical parameters are most relevant, commonly used, and able to distinguish and/or have specific clinical relevance to the effect of variations in LLD magnitude during static (standing) and dynamic (walking) conditions. Several electronic databases containing studies from the year 1983 to 2016 (Scopus, ScienceDirect, PubMed, PMC, and ProQuest) were obtained in our literature search. The search process yielded 22 published articles that fulfilled our criteria. We found most of the published data that we analyzed to be inconsistent, and very little data was obtained on the correlation between LLD severity and changes in body posture stability during standing and walking. However, the results of the present review study are in line with previous observational studies, which describe asymmetry in the lower limbs corresponding to biomechanical parameters such as gait kinematics, kinetics, and other parameters described during static (standing) postural balance. In future investigations, we believe that it might be useful to use and exploit other balance-related factors that may potentially influence body posture stability.
    Matched MeSH terms: Biomechanical Phenomena
  15. Perera CK, Gopalai AA, Gouwanda D, Ahmad SA, Salim MSB
    Sci Rep, 2023 Oct 03;13(1):16640.
    PMID: 37789077 DOI: 10.1038/s41598-023-43148-0
    Forward continuation, balance, and sit-to-stand-and-walk (STSW) are three common movement strategies during sit-to-walk (STW) executions. Literature identifies these strategies through biomechanical parameters using gold standard laboratory equipment, which is expensive, bulky, and requires significant post-processing. STW strategy becomes apparent at gait-initiation (GI) and the hip/knee are primary contributors in STW, therefore, this study proposes to use the hip/knee joint angles at GI as an alternate method of strategy classification. To achieve this, K-means clustering was implemented using three clusters corresponding to the three STW strategies; and two feature sets corresponding to the hip/knee angles (derived from motion capture data); from an open access online database (age: 21-80 years; n = 10). The results identified forward continuation with the lowest hip/knee extension, followed by balance and then STSW, at GI. Using this classification, strategy biomechanics were investigated by deriving the established biomechanical quantities from literature. The biomechanical parameters that significantly varied between strategies (P 
    Matched MeSH terms: Biomechanical Phenomena
  16. Samsudin OC, Aminuddin BS, Munirah S, Chua KH, Fuzina NH, Isa MR, et al.
    Med J Malaysia, 2004 May;59 Suppl B:15-6.
    PMID: 15468796
    Treatment of articular cartilage lesions remains a clinical challenge. The uses of prosthetic joint replace allograft and/or autograft transplant carry a risk of complications due to infection, loosening of its component, immunological rejection and morbidity at the donor site. There has been an increasing interest in the management of cartilage damages, owing to the introduction of new therapeutic options. Tissue engineering as a method for tissue restoration begins to provide a potential alternative therapy for autologous grafts transplantations. We aimed to evaluate how well a tissue engineered neocartilage implant, consist of human articular chondrocytes cultured with the presence of autologous serum and mixed in a fresh fibrin derived from patient, would perform in subcutaneous implantation in athymic mice.
    Matched MeSH terms: Biomechanical Phenomena
  17. Azizan NA, Basaruddin KS, Salleh AF, Sulaiman AR, Safar MJA, Rusli WMR
    J Healthc Eng, 2018;2018:7815451.
    PMID: 29983905 DOI: 10.1155/2018/7815451
    Balance in the human body's movement is generally associated with different synergistic pathologies. The trunk is supported by one's leg most of the time when walking. A person with poor balance may face limitation when performing their physical activities on a daily basis, and they may be more prone to having risk of fall. The ground reaction forces (GRFs), centre of pressure (COP), and centre of mass (COM) in quite standing posture were often measured for the evaluation of balance. Currently, there is still no experimental evidence or study on leg length discrepancy (LLD) during walking. Analysis of the stability parameters is more representative of the functional activity undergone by the person who has a LLD. Therefore, this study hopes to shed new light on the effects of LLD on the dynamic stability associated with VGRF, COP, and COM during walking. Eighteen healthy subjects were selected among the university population with normal BMIs. Each subject was asked to walk with 1.0 to 2.0 ms-1 of walking speed for three to five trials each. Insoles of 0.5 cm thickness were added, and the thickness of the insoles was subsequently raised until 4 cm and placed under the right foot as we simulated LLD. The captured data obtained from a force plate and motion analysis present Peak VGRF (single-leg stance) and WD (double-leg stance) that showed more forces exerted on the short leg rather than long leg. Obviously, changes occurred on the displacement of COM trajectories in the ML and vertical directions as LLD increased at the whole gait cycle. Displacement of COP trajectories demonstrated that more distribution was on the short leg rather than on the long leg. The root mean square (RMS) of COP-COM distance showed, obviously, changes only in ML direction with the value at 3 cm and 3.5 cm. The cutoff value via receiver operating characteristic (ROC) indicates the significant differences starting at the level 2.5 cm up to 4 cm in long and short legs for both AP and ML directions. The present study performed included all the proposed parameters on the effect of dynamic stability on LLD during walking and thus helps to determine and evaluate the balance pattern.
    Matched MeSH terms: Biomechanical Phenomena
  18. Panagiotopoulou O, Iriarte-Diaz J, Wilshin S, Dechow PC, Taylor AB, Mehari Abraha H, et al.
    Zoology (Jena), 2017 10;124:13-29.
    PMID: 29037463 DOI: 10.1016/j.zool.2017.08.010
    Finite element analysis (FEA) is a commonly used tool in musculoskeletal biomechanics and vertebrate paleontology. The accuracy and precision of finite element models (FEMs) are reliant on accurate data on bone geometry, muscle forces, boundary conditions and tissue material properties. Simplified modeling assumptions, due to lack of in vivo experimental data on material properties and muscle activation patterns, may introduce analytical errors in analyses where quantitative accuracy is critical for obtaining rigorous results. A subject-specific FEM of a rhesus macaque mandible was constructed, loaded and validated using in vivo data from the same animal. In developing the model, we assessed the impact on model behavior of variation in (i) material properties of the mandibular trabecular bone tissue and teeth; (ii) constraints at the temporomandibular joint and bite point; and (iii) the timing of the muscle activity used to estimate the external forces acting on the model. The best match between the FEA simulation and the in vivo experimental data resulted from modeling the trabecular tissue with an isotropic and homogeneous Young's modulus and Poisson's value of 10GPa and 0.3, respectively; constraining translations along X,Y, Z axes in the chewing (left) side temporomandibular joint, the premolars and the m1; constraining the balancing (right) side temporomandibular joint in the anterior-posterior and superior-inferior axes, and using the muscle force estimated at time of maximum strain magnitude in the lower lateral gauge. The relative strain magnitudes in this model were similar to those recorded in vivo for all strain locations. More detailed analyses of mandibular strain patterns during the power stroke at different times in the chewing cycle are needed.
    Matched MeSH terms: Biomechanical Phenomena
  19. Rosli Darmawan
    MyJurnal
    The study on the possibility of using DMU Kinematics module in CAE tools for dose exposure work planning was carried out. A case scenario was created using 3D CAD software and transferred to DMU Kinematics module in a CAE software. The work plan created using DMU Kinematics module was animated to simulate a real time scenario. Data on the phantom position against the radioactive source was collected by activating positioning sensors in the module. The data collected was used to calculate the estimated dose rate exposure for the phantom. The results can be used to plan the safest and optimum procedures in carrying out the radiation related task.
    Matched MeSH terms: Biomechanical Phenomena
  20. Donnelly CJ, Weir G, Jackson C, Alderson J, Rafeeuddin R, Sharir R, et al.
    Sports Biomech, 2024 Mar;23(3):324-334.
    PMID: 33886425 DOI: 10.1080/14763141.2020.1860254
    Much inter-intra-tester kinematic and kinetic repeatability research exists, with a paucity investigating inter-laboratory equivalence. The objective of this research was to evaluate the inter-laboratory equivalence between time varying unplanned kinematics and moments of unplanned sidestepping (UnSS). Eight elite female athletes completed an established UnSS procedure motion capture laboratories in the UK and Australia. Three dimensional time varying unplanned sidestepping joint kinematics and moments were compared. Discrete variables were change of direction angles and velocity. Waveform data were compared using mean differences, 1D 95%CI and RMSE. Discrete variables were compared using 0D 95% CI. The mean differences and 95%CI for UnSS kinematics broadly supported equivalence between laboratories (RMSE≤5.1°). Excluding hip flexion/extension moments (RMSE = 1.04 Nm/kg), equivalence was also supported for time varying joint moments between laboratories (RMSE≤0.40 Nm/kg). Dependent variables typically used to characterise UnSS were also equivalent. When consistent experimental and modelling procedures are employed, consistent time varying UnSS lower limb joint kinematic and moment estimates between laboratories can be obtained. We therefore interpret these results as a support of equivalence, yet highlight the challenges of establishing between-laboratory experiments or data sharing, as well as establishing appropriate ranges of acceptable uncertainty. These findings are important for data sharing and multi-centre trials.
    Matched MeSH terms: Biomechanical Phenomena
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links