Displaying publications 41 - 60 of 470 in total

Abstract:
Sort:
  1. Ong YP, Ho LN, Ong SA, Banjuraizah J, Ibrahim AH, Lee SL, et al.
    Chemosphere, 2019 Mar;219:277-285.
    PMID: 30543963 DOI: 10.1016/j.chemosphere.2018.12.004
    Photocatalytic fuel cell (PFC) is considered as a sustainable green technology which could degrade organic pollutant and generate electricity simultaneously. A synergistic double-sided ZnO/BaTiO3 loaded carbon plate heterojunction photoanode was fabricated in different ratios by using simple ultrasonication and mixed-annealed method. The double-sided design of photoanode allowed the lights irradiated at both sides of the photoanode. The ferroelectricity fabricated photoanode was applied in a membraneless PFC with platinum-loaded carbon as the cathode. Results revealed that the photoanode with 1:1 ratio of BaTiO3 and ZnO exhibited a superior photocatalytic activity among all the photoanodes prepared in this study. The heterojunction of this photoanode was able to achieve up to a removal efficiency of 93.67% with a maximum power density of 0.5284 μW cm-2 in 10 mg L-1 of Reactive Red 120 (RR120) without any supporting electrolyte. This photoanode was able to maintain at high performance after recycling 3 times. Overloading of ZnO above 50% on BaTiO3 could lead to deterioration of the performance of PFC due to the charge defects and light trapping ability. The interactions, interesting polarizations of the photocatalysts and proposed mechanism of the n-n type heterojunction in the photoanode of ZnO/BaTiO3 was also discussed.
    Matched MeSH terms: Electrodes
  2. Norha Abdul Hadi, Mawar Hasyikin Abu Seman, Madhiyah Yahaya Bermakai
    MyJurnal
    Derivation of activated carbon from biomass wastes for energy storage applications such as fuel cells and supercapacitors are attracting wide attractions as the world is now demand for other sustainable energy that can help to explore new technologies especially for energy conversion and storage. This is important because the world now is facing a rapid depletion of fossil energy. In this review, an outline of recent trends towards biomass-derived specifically from fruit-based biomass wastes is explained in a holistic manner. Thanks to their high carbon content, high specific surface area and developed porous structure, biomass-derived chars can be treated and converted into carbon. The performance of activated carbon in terms of Brunette Emmet Teller (BET) surface area, micropore volume, total pore volume and specific capacitance has been reported. This review showed that higher BET surface will contribute to higher pore volume in the activated carbon that makes them good candidates for the fabrication of electrodes in supercapacitor applications. This study was focused on providing a detailed comparison of published studies that utilized different physical and chemical routes and their effect of modification such as various activation temperatures and the ratio of activating agents towards the performance of the activated carbon under different parameters. Implementing chemical routes with an ideal 600°C – 850°C and inclusion ratio might be effective to produce high performance activated carbon.
    Matched MeSH terms: Electrodes
  3. Jumat Salimon
    Sains Malaysiana, 2007;36:27-32.
    The adsorption of CO at polycrystalline copper surface was investigated spectroscopically. It was found that CO adsorbed as a linear adsorbed CO, Cu-COL and was a dominant species on copper surface at low CO concentration. A Cu-COL was electrochemically converted to a bridge bonded CO, Cu-COB at a high CO concentration condition. Increasing the CO surface coverage, qCO will increase the formation of adsorbed bridge bonded CO. A nitrogen gas purging treatment was used to examine the stability of an adsorbed CO through the evacuation process. The result showed that Cu-COB remained intact while Cu-COL was completely removed from the copper surface. It suggests that Cu-COL may involve in a weak bonding to a copper surface such as in a physisorbed interaction, while Cu-COB consists much stronger bonding such as a chemisorbed interaction. The N2 purging treatment also gave an additional prove that Cu-COB was partly converted to Cu(I)-CO at anodic potential regions.
    Matched MeSH terms: Electrodes
  4. Jatoi AS, Akhter F, Mazari SA, Sabzoi N, Aziz S, Soomro SA, et al.
    Environ Sci Pollut Res Int, 2021 Feb;28(5):5005-5019.
    PMID: 33241504 DOI: 10.1007/s11356-020-11691-2
    Petroleum, coal, and natural gas reservoir were depleting continuously due to an increase in industrialization, which enforced study to identify alternative sources. The next option is the renewable resources which are most important for energy purpose coupled with environmental problem reduction. Microbial fuel cells (MFCs) have become a promising approach to generate cleaner and more sustainable electrical energy. The involvement of various disciplines had been contributing to enhancing the performance of the MFCs. This review covers the performance of MFC along with different wastewater as a substrate in terms of treatment efficiencies as well as for energy generation. Apart from this, effect of various parameters and use of different nanomaterials for performance of MFC were also studied. From the current study, it proves that the use of microbial fuel cell along with the use of nanomaterials could be the waste and energy-related problem-solving approach. MFC could be better in performances based on optimized process parameters for handling any wastewater from industrial process.
    Matched MeSH terms: Electrodes
  5. Gopinath SCB, Ismail ZH, Shapiai MI, Yasin MNM
    PMID: 34009645 DOI: 10.1002/bab.2196
    Current developments in sensors and actuators are heralding a new era to facilitate things to happen effortlessly and efficiently with proper communication. On the other hand, Internet of Things (IoT) has been boomed up with er potential and occupies a wide range of disciplines. This study has choreographed to design of an algorithm and a smart data-processing scheme to implement the obtained data from the sensing system to transmit to the receivers. Technically, it is called "telediagnosis" and "remote digital monitoring," a revolution in the field of medicine and artificial intelligence. For the proof of concept, an algorithmic approach has been implemented for telediagnosis with one of the degenerative diseases, that is, Parkinson's disease. Using the data acquired from an improved interdigitated electrode, sensing surface was evaluated with the attained sensitivity of 100 fM (n = 3), and the limit of detection was calculated with the linear regression value coefficient. By the designed algorithm and data processing with the assistance of IoT, further validation was performed and attested the coordination. This proven concept can be ideally used with all sensing strategies for immediate telemedicine by end-to-end communications.
    Matched MeSH terms: Electrodes
  6. Shukla V, Hussin FA, Hamid NH, Zain Ali NB
    Sensors (Basel), 2017 Jul 27;17(8).
    PMID: 28749411 DOI: 10.3390/s17081719
    With the advancement of digital microfluidics technology, applications such as on-chip DNA analysis, point of care diagnosis and automated drug discovery are common nowadays. The use of Digital Microfluidics Biochips (DMFBs) in disease assessment and recognition of target molecules had become popular during the past few years. The reliability of these DMFBs is crucial when they are used in various medical applications. Errors found in these biochips are mainly due to the defects developed during droplet manipulation, chip degradation and inaccuracies in the bio-assay experiments. The recently proposed Micro-electrode-dot Array (MEDA)-based DMFBs involve both fluidic and electronic domains in the micro-electrode cell. Thus, the testing techniques for these biochips should be revised in order to ensure proper functionality. This paper describes recent advances in the testing technologies for digital microfluidics biochips, which would serve as a useful platform for developing revised/new testing techniques for MEDA-based biochips. Therefore, the relevancy of these techniques with respect to testing of MEDA-based biochips is analyzed in order to exploit the full potential of these biochips.
    Matched MeSH terms: Electrodes
  7. Valli H, Ahmad S, Chadda KR, Al-Hadithi ABAK, Grace AA, Jeevaratnam K, et al.
    Mech Ageing Dev, 2017 Oct;167:30-45.
    PMID: 28919427 DOI: 10.1016/j.mad.2017.09.002
    INTRODUCTION: Ageing and several age-related chronic conditions including obesity, insulin resistance and hypertension are associated with mitochondrial dysfunction and represent independent risk factors for atrial fibrillation (AF).

    MATERIALS AND METHODS: Atrial arrhythmogenesis was investigated in Langendorff-perfused young (3-4 month) and aged (>12 month), wild type (WT) and peroxisome proliferator activated receptor-γ coactivator-1β deficient (Pgc-1β-/-) murine hearts modeling age-dependent chronic mitochondrial dysfunction during regular pacing and programmed electrical stimulation (PES).

    RESULTS AND DISCUSSION: The Pgc-1β-/- genotype was associated with a pro-arrhythmic phenotype progressing with age. Young and aged Pgc-1β-/- hearts showed compromised maximum action potential (AP) depolarization rates, (dV/dt)max, prolonged AP latencies reflecting slowed action potential (AP) conduction, similar effective refractory periods and baseline action potential durations (APD90) but shortened APD90 in APs in response to extrasystolic stimuli at short stimulation intervals. Electrical properties of APs triggering arrhythmia were similar in WT and Pgc-1β-/- hearts. Pgc-1β-/- hearts showed accelerated age-dependent fibrotic change relative to WT, with young Pgc-1β-/- hearts displaying similar fibrotic change as aged WT, and aged Pgc-1β-/- hearts the greatest fibrotic change. Mitochondrial deficits thus result in an arrhythmic substrate, through slowed AP conduction and altered repolarisation characteristics, arising from alterations in electrophysiological properties and accelerated structural change.

    Matched MeSH terms: Electrodes
  8. Ramanathan S, Gopinath SCB, Arshad MKM, Poopalan P, Anbu P, Lakshmipriya T, et al.
    Sci Rep, 2019 11 19;9(1):17013.
    PMID: 31745155 DOI: 10.1038/s41598-019-53573-9
    Lung cancer is one of the most serious threats to human where 85% of lethal death caused by non-small cell lung cancer (NSCLC) induced by epidermal growth factor receptor (EGFR) mutation. The present research focuses in the development of efficient and effortless EGFR mutant detection strategy through high-performance and sensitive genosensor. The current amplified through 250 µm sized fingers between 100 µm aluminium electrodes indicates the voltammetry signal generated by means of the mutant DNA sequence hybridization. To enhance the DNA immobilization and hybridization, ∼25 nm sized aluminosilicate nanocomposite synthesized from the disposed joss fly ash was deposited on the gaps between aluminium electrodes. The probe, mutant (complementary), and wild (single-base pair mismatch) targets were designed precisely from the genomic sequences denote the detection of EGFR mutation. Fourier-transform Infrared Spectroscopy analysis was performed at every step of surface functionalization evidences the relevant chemical bonding of biomolecules on the genosensor as duplex DNA with peak response at 1150 cm-1 to 1650 cm-1. Genosensor depicts a sensitive EGFR mutation as it is able to detect apparently at 100 aM mutant against 1 µM DNA probe. The insignificant voltammetry signal generated with wild type strand emphasizes the specificity of genosensor in the detection of single base pair mismatch. The inefficiency of genosensor in detecting EGFR mutation in the absence of aluminosilicate nanocomposite implies the insensitivity of genosensing DNA hybridization and accentuates the significance of aluminosilicate. Based on the slope of the calibration curve, the attained sensitivity of aluminosilicate modified genosensor was 3.02E-4 A M-1. The detection limit of genosensor computed based on 3σ calculation, relative to the change of current proportional to the logarithm of mutant concentration is at 100 aM.
    Matched MeSH terms: Electrodes
  9. Li Z, Cui L, Zhao H, Du J, Gopinath SCB, Lakshmipriya T, et al.
    Dev Neurosci, 2021;43(1):53-62.
    PMID: 33849012 DOI: 10.1159/000515197
    OBJECTIVE: Brain-derived neurotrophic factor (BDNF) dysregulation is widely related with various psychiatric and neurological disorders, including schizophrenia, depression, Rett syndrome, and addiction, and the available evidence suggests that BDNF is also highly correlated with Parkinson's and Alzheimer's diseases.

    METHODS: The BDNF target sequence was detected on a capture probe attached on aluminum microcomb electrodes on the silicon wafer surface. A capture-target-reporter sandwich-type assay was performed to enhance the detection of the BDNF target.

    RESULTS: The limit of detection was noticed to be 100 aM. Input of a reporter sequence at concentrations >10 aM improved the detection of the target sequence by enhancing changes in the generated currents. Control experiments with noncomplementary and single- and triple-mismatches of target and reporter sequences did not elicit changes in current levels, indicating the selective detection of the BDNF gene sequence.

    CONCLUSION: The above detection strategy will be useful for the detection and quantification of BDNF, thereby aiding in the provision of suitable treatments for BDNF-related disorders.

    Matched MeSH terms: Electrodes
  10. Qiu Z, Shen Q, Jiang C, Yao L, Sun X, Li J, et al.
    Int J Nanomedicine, 2021;16:2311-2322.
    PMID: 33776435 DOI: 10.2147/IJN.S302396
    Background: Alzheimer's disease (AD) is a neurodegenerative chronic disorder that causes dementia and problems in thinking, cognitive impairment and behavioral changes. Amyloid-beta (Aβ) is a peptide involved in AD progression, and a high level of Aβ is highly correlated with severe AD. Identifying and quantifying Aβ levels helps in the early treatment of AD and reduces the factors associated with AD.

    Materials and Methods: This research introduced a dual probe detection system involving aptamers and antibodies to identify Aβ. Aptamers and antibodies were attached to the gold (Au) urchin and hybrid on the carbon nanohorn-modified surface. The nanohorn was immobilized on the sensor surface by using an amine linker, and then a Au urchin dual probe was immobilized.

    Results: This dual probe-modified surface enhanced the current flow during Aβ detection compared with the surface with antibody as the probe. This dual probe interacted with higher numbers of Aβ peptides and reached the detection limit at 10 fM with R2=0.992. Furthermore, control experiments with nonimmune antibodies, complementary aptamer sequences and control proteins did not display the current responses, indicating the specific detection of Aβ.

    Conclusion: Aβ-spiked artificial cerebrospinal fluid showed a similar response to current changes, confirming the selective identification of Aβ.

    Matched MeSH terms: Electrodes
  11. Lam SM, Sin JC, Zeng H, Lin H, Li H, Mohamed AR, et al.
    Chemosphere, 2022 Jan;287(Pt 4):132384.
    PMID: 34597645 DOI: 10.1016/j.chemosphere.2021.132384
    BiFeO3 nanoparticle decorated on flower-like ZnO (BiFeO3/ZnO) was fabricated through a facile hydrothermal-reflux combined method. This material was utilized as a composite photocathode for the first time in microbial fuel cell (MFC) to reduce the copper ion (Cu2+) and power generation concomitantly. The resultant BiFeO3/ZnO-based MFC displayed distinct photoelectrocatalytic activities when different weight percentages (wt%) BiFeO3 were used. The 3 wt% BiFeO3/ZnO MFC achieved the maximum power density of 1.301 W m-2 in the catholyte contained 200 mg L-1 of Cu2+ and the power density was greatly higher than those pure ZnO and pure BiFeO3 photocathodes. Meanwhile, the MFC exhibited 90.7% removal of Cu2+ within 6 h under sunlight exposure at catholyte pH 4. The addition of BiFeO3 nanoparticles not only manifested outstanding capability in harvesting visible light, but also facilitated the formation of Z-scheme BiFeO3/ZnO heterojunction structure to induce the charge carrier transfer along with enhanced redox abilities for the cathodic reduction. The pronounced electrical output and Cu2+ reduction efficiencies can be realized through the synergistic cooperation between the bioanode and BiFeO3/ZnO photocathode in the MFC. Furthermore, the developed BiFeO3/ZnO composite presented a good stability and reusability of photoelectrocatalytic activity up to five cyclic runs.
    Matched MeSH terms: Electrodes
  12. Ali S, Tahir M, Mehboob N, Wahab F, J Langford S, Mohd Said S, et al.
    Materials (Basel), 2020 Feb 21;13(4).
    PMID: 32098037 DOI: 10.3390/ma13040960
    This work reports synthesis, thin film characterizations, and study of an organic semiconductor 2-aminoanthraquinone (AAq) for humidity and temperature sensing applications. The morphological and phase studies of AAq thin films are carried out by scanning electron microscope (SEM), atomic force microscope (AFM), and X-ray diffraction (XRD) analysis. To study the sensing properties of AAq, a surface type Au/AAq/Au sensor is fabricated by thermally depositing a 60 nm layer of AAq at a pressure of ~10-5 mbar on a pre-patterned gold (Au) electrodes with inter-electrode gap of 45 µm. To measure sensing capability of the Au/AAq/Au device, the variations in its capacitance and resistance are studied as a function of humidity and temperature. The Au/AAq/Au device measures and exhibits a linear change in capacitance and resistance when relative humidity (%RH) and temperature are varied. The AAq is a hydrophobic material which makes it one of the best candidates to be used as an active material in humidity sensors; on the other hand, its high melting point (575 K) is another appealing property that enables it for its potential applications in temperature sensors.
    Matched MeSH terms: Electrodes
  13. Yusoff N, Rameshkumar P, Mohamed Noor A, Huang NM
    Mikrochim Acta, 2018 04 03;185(4):246.
    PMID: 29616348 DOI: 10.1007/s00604-018-2782-x
    An amperometric sensor for L-Cys is described which consists of a glassy carbon electrode (GCE) that was modified with reduced graphene oxide placed in a Nafion film and decorated with palladium nanoparticles (PdNPs). The film was synthesized by a hydrothermal method. The PdNPs have an average diameter of about 10 nm and a spherical shape. The modified GCE gives a linear electro-oxidative response to L-Cys (typically at +0.6 V vs. SCE) within the 0.5 to 10 μM concentration range. Other figures of merit include a response time of less than 2 s, a 0.15 μM lower detection limit (at signal to noise ratio of 3), and an analytical sensitivity of 1.30 μA·μM-1·cm-2. The sensor displays selectivity over ascorbic acid, uric acid, dopamine, hydrogen peroxide, urea, and glucose. The modified GCE was applied to the determination of L-Cys in human urine samples and gave excellent recoveries. Graphical abstract Spherical palladium nanoparticles (PdNPs) on reduced graphene oxide-Nafion (rGO-Nf) films were synthesized using a hydrothermal method. This nanohybrid was used for modifying a glassy carbon electrode to develop a sensor electrode for detecting L-cysteine that has fast response (less than 2 s), low detection limit (0.15 μM), and good sensitivity (0.092 μA μM-1 cm-2).
    Matched MeSH terms: Electrodes
  14. Mohd Zain Z, Ab Ghani S, O'Neill RD
    Amino Acids, 2012 Nov;43(5):1887-94.
    PMID: 22865247 DOI: 10.1007/s00726-012-1365-0
    This paper discusses the application of a reagentless, selective microbiosensor as a useful alternative tool for monitoring D-serine in neural samples. The main components of the 125-μm-diameter disk biosensor were D-amino acid oxidase for D-serine sensitivity (linear region slope, 61 ± 7 μA cm(-2) mM(-1); limit of detection, 20 nM), and poly-phenylenediamine for rejection of electroactive interference. The response time of the biosensor was of the order of 1 s, ideal for 'real-time' monitoring, and detection of systemically administered D-serine in brain extracellular fluid is demonstrated. Exploitation of this probe might resolve queries involving regulation of D-serine in excitotoxicity, and modulation of N-methyl-D-aspartate receptor function by D-serine and glycine in the central nervous system.
    Matched MeSH terms: Electrodes, Implanted
  15. Nik Mansor NN, Leong TT, Safitri E, Futra D, Ahmad NS, Nasuruddin DN, et al.
    Sensors (Basel), 2018 Feb 26;18(3).
    PMID: 29495352 DOI: 10.3390/s18030686
    A tri-enzyme system consisting of choline kinase/choline oxidase/horseradish peroxidase was used in the rapid and specific determination of the biomarker for bacterial sepsis infection, secretory phospholipase Group 2-IIA (sPLA2-IIA). These enzymes were individually immobilized onto the acrylic microspheres via succinimide groups for the preparation of an electrochemical biosensor. The reaction of sPLA2-IIA with its substrate initiated a cascading enzymatic reaction in the tri-enzyme system that led to the final production of hydrogen peroxide, which presence was indicated by the redox characteristics of potassium ferricyanide, K₃Fe(CN)₆. An amperometric biosensor based on enzyme conjugated acrylic microspheres and gold nanoparticles composite coated onto a carbon-paste screen printed electrode (SPE) was fabricated and the current measurement was performed at a low potential of 0.20 V. This enzymatic biosensor gave a linear range 0.01-100 ng/mL (R² = 0.98304) with a detection limit recorded at 5 × 10-3 ng/mL towards sPLA2-IIA. Moreover, the biosensor showed good reproducibility (relative standard deviation (RSD) of 3.04% (n = 5). The biosensor response was reliable up to 25 days of storage at 4 °C. Analysis of human serum samples for sPLA2-IIA indicated that the biosensor has potential for rapid bacterial sepsis diagnosis in hospital emergency department.
    Matched MeSH terms: Electrodes
  16. Md Sani ND, Ariffin EY, Sheryn W, Shamsuddin MA, Heng LY, Latip J, et al.
    Sensors (Basel), 2019 Nov 22;19(23).
    PMID: 31766637 DOI: 10.3390/s19235111
    A toxicity electrochemical DNA biosensor has been constructed for the detection of carcinogens using 24 base guanine DNA rich single stranded DNA, and methylene blue (MB) as the electroactive indicator. This amine terminated ssDNA was immobilized onto silica nanospheres and deposited on gold nanoparticle modified carbon-paste screen printed electrodes (SPEs). The modified SPE was initially exposed to a carcinogen, followed by immersion in methylene blue for an optimized duration. The biosensor response was measured using differential pulse voltammetry. The performance of the biosensor was identified on several anti-cancer compounds. The toxicity DNA biosensor demonstrated a linear response range to the cadmium chloride from 0.0005 ppm to 0.01 ppm (R2 = 0.928) with a limit of detection at 0.0004 ppm. The biosensor also exhibited its versatility to screen the carcinogenicity of potential anti-cancer compounds.
    Matched MeSH terms: Electrodes
  17. Davoodi H, Nordin N, Bordonali L, Korvink JG, MacKinnon N, Badilita V
    Lab Chip, 2020 08 26;20(17):3202-3212.
    PMID: 32734975 DOI: 10.1039/d0lc00364f
    Combining microfluidic devices with nuclear magnetic resonance (NMR) has the potential of unlocking their vast sample handling and processing operation space for use with the powerful analytics provided by NMR. One particularly challenging class of integrated functional elements from the perspective of NMR are conductive structures. Metallic electrodes could be used for electrochemical sample interaction for example, yet they can cause severe NMR spectral and SNR degradation. These issues are more entangled at the micro-scale since the distorted volume occupies a higher ratio of the sample volume. In this study, a combination of simulation and experimental validation was used to identify an electrode geometry that, in terms of NMR spectral parameters, performs as well as for the case when no electrodes are present. By placing the metal tracks in the side-walls of a microfluidic channel, we found that NMR RF excitation performance was actually enhanced, without compromising B0 homogeneity. Monitoring in situ deposition of chitosan in the microfluidic platform is presented as a proof-of-concept demonstration of NMR characterisation of an electrochemical process.
    Matched MeSH terms: Electrodes
  18. Białobrzeska W, Dziąbowska K, Lisowska M, Mohtar MA, Muller P, Vojtesek B, et al.
    Biosensors (Basel), 2021 Jun 07;11(6).
    PMID: 34200338 DOI: 10.3390/bios11060184
    The detection of cancer antigens is a major aim of cancer research in order to develop better patient management through early disease detection. Many cancers including prostate, lung, and ovarian secrete a protein disulfide isomerase protein named AGR2 that has been previously detected in urine and plasma using mass spectrometry. Here we determine whether a previously developed monoclonal antibody targeting AGR2 can be adapted from an indirect two-site ELISA format into a direct detector using solid-phase printed gold electrodes. The screen-printed gold electrode was surface functionalized with the anti-AGR2 specific monoclonal antibody. The interaction of the recombinant AGR2 protein and the anti-AGR2 monoclonal antibody functionalized electrode changed its electrochemical impedance spectra. Nyquist diagrams were obtained after incubation in an increasing concentration of purified AGR2 protein with a range of concentrations from 0.01 fg/mL to 10 fg/mL. In addition, detection of the AGR2 antigen can be achieved from cell lysates in medium or artificial buffer. These data highlight the utility of an AGR2-specific monoclonal antibody that can be functionalized onto a gold printed electrode for a one-step capture and quantitation of the target antigen. These platforms have the potential for supporting methodologies using more complex bodily fluids including plasma and urine for improved cancer diagnostics.
    Matched MeSH terms: Electrodes
  19. Mohammad R, Ahmad M, Heng LY
    Sensors (Basel), 2013 Aug 05;13(8):10014-26.
    PMID: 23921830 DOI: 10.3390/s130810014
    Chili hotness is very much dependent on the concentration of capsaicin present in the chili fruit. A new biosensor based on a horseradish peroxidase enzyme-capsaicin reaction mediated by ferrocene has been successfully developed for the amperometric determination of chili hotness. The amperometric biosensor is fabricated based on a single-step immobilization of both ferrocene and horseradish peroxidase in a photocurable hydrogel membrane, poly(2-hydroxyethyl methacrylate). With mediation by ferrocene, the biosensor could measure capsaicin concentrations at a potential 0.22 V (vs. Ag/AgCl), which prevented potential interference from other electroactive species in the sample. Thus a good selectivity towards capsaicin was demonstrated. The linear response range of the biosensor towards capsaicin was from 2.5-99.0 µM with detection limit of 1.94 µM. A good relative standard deviation (RSD) for reproducibility of 6.4%-9.9% was obtained. The capsaicin biosensor demonstrated long-term stability for up to seven months. The performance of the biosensor has been validated using a standard method for the analysis of capsaicin based on HPLC.
    Matched MeSH terms: Electrodes
  20. Hanafi Ithnin, Khalid Kasmin M, Radzi Mat Isa A, Shaari A, Armed R
    Sains Malaysiana, 2014;43:819-825.
    Quantum dots being an interesting class of nanostructures are considered potential prototype systems for novel nano-devices such as single electron transistor (sET). Here in this research, we present an analysis of the electron trajectory in the vicinity of gallium arsenide (GaAs) quantum dot. To perform this study, DFT based methodology is employed to optimize structure of quantum dot and determining the electrostatic potential around the dot. Under the influence of obtained electrostatic potential, trajectory of the moving electron towards the dot is investigated. The results showed that GaAs quantum dot have negative and positive potential surfaces that influence the electron interaction with the dot. These results motivate the development of SET electrode channel where the electron moves towards the dot on the surface with positive potential rather than negative potential surface.
    Matched MeSH terms: Electrodes
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links