Nickel-impregnated TiO2 photocatalyst (NiTP) responding to visible light was prepared by the liquid phase plasma (LPP) method, and its photoactivity was evaluated in degrading an antibiotic (oxytetracycline, OTC). For preparing the photocatalyst, nickel was uniformly impregnated onto TiO2 (P-25) powder, and the nickel content increased as the number of LPP reactions increased. In addition, the morphology and lattice of NiTP were observed through various instrumental analyses, and it was confirmed that NiO-type nanoparticles were impregnated in NiTP. Fundamentally, as the amount of impregnated nickel in the TiO2 powder increased sufficiently, the band gap energy of TiO2 decreased, and eventually, the NiTP excited by visible light was synthesized. Further, OTC had a decomposition reaction pathway in which active radicals generated in OTC photocatalytic reaction under NiTP were finally mineralized through reactions such as decarboxamidation, hydration, deamination, demethylation, and dehydroxylation. In effect, we succeeded in synthesizing a photocatalyst useable under visible light by performing only the LPP single process and developed a new advanced oxidation process (AOP) that can remove toxic antibiotics.
In this study, nickel-loaded perovskite oxides catalysts were synthesized via the impregnation of 10%Ni on XTiO3 (X = Ce, Sr, La, Ba, Ca, and Fe) supports and employed in the catalytic steam gasification of swine manure to produce H2-rich syngas for the first time. The synthesized catalysts were characterized using BET, H2-TPR, XRD, HR-TEM, and EDX analysis. Briefly, using perovskite supports resulted in the production of ultrafine catalyst nanoparticles with a uniform dispersion of Ni particles. According to the catalytic activity test, the gas yield showed the increment as 10% Ni/LaTiO3 < 10% Ni/FeTiO3 < 10% Ni/CeTiO3 < 10% Ni/BaTiO3 < 10% Ni/SrTiO3 < 10% Ni/CaTiO3. Meanwhile, zero coke formation was achieved due to the oxygen mobility of prepared catalysts. Also, the increase in the H2 production for the applied catalysts was in the sequence as 10% Ni/CeTiO3 < 10% Ni/FeTiO3 < 10% Ni/LaTiO3 < 10% Ni/BaTiO3 < 10% Ni/SrTiO3 < 10% Ni/CaTiO3. The maximum H2 selectivity (∼48 vol%) obtained by10% Ni/CaTiO3 was probably due to the synergistic effect of Ni and Ti on enhancing the water-gas shift reaction, and Ca on creating the maximum oxygen mobility compared to other alkaline earth metals doped at the A place of perovskite. Overall, this study provides a suitable solution for enhanced H2 production through steam gasification of swine manure along with suggesting the appropriate supports to prevent Ni deactivation by lowering coke formation at the same time.
This study assessed the corrosion resistance, intracutaneous reactivity, acute systemic toxicity, and in situ tissue effect of the implantation of porous NiTi fabricated by metal injection molding in animal models. For the intracutaneous reactivity study, five intracutaneous injections were administered per site with and without the tested extract in polar and nonpolar solutions. The extract was also delivered via intravenous and intraperitoneal routes for acute systemic toxicity. TiAl6 V4 (control) and porous NiTi were implanted in rabbit femora for a period of 13 weeks to evaluate the in situ tissue response. Corrosion was evaluated through open and cyclic polarization in PBS, while biocompatibility was investigated by assessing the general conditions, skin irritation score (edema and erythema), and histopathology. No active dissolution or hysteresis loop was observed in the corrosion study. None of the animals exhibited death, moribundity, impending death, severe pain, self-mutilation, or overgrooming. No edema was observed at injection sites. Only the positive control showed an erythematous reaction at 24, 48, and 72 h observations (p < 0.001). Porous NiTi showed a low in situ biological response for inflammation, neovascularization, and fibrosis in comparison to the control implant (p = 0.247, 0.005, and 0.011, respectively). Porous NiTi also demonstrated high pitting corrosion resistance while causing no acute hypersensitivity or acute systemic toxicity. The study concludes that porous NiTi implants were unlikely to cause local sensitization, acute systemic toxicity, or chronic inflammatory reactions in an animal model. Porous NiTi also exhibited osseointegration equivalent to Ti6AI4 V of known biocompatibility.
The catalytic activity of low-dimensional electrocatalysts is highly dependent on their local atomic structures, particularly those less-coordinated sites found at edges and corners; therefore, a direct probe of the electrocatalytic current at specified local sites with true nanoscopic resolution has become critically important. Despite the growing availability of operando imaging tools, to date it has not been possible to measure the electrocatalytic activities from individual material edges and directly correlate those with the local structural defects. Herein, we show the possibility of using feedback and generation/collection modes of operation of the scanning electrochemical microscope (SECM) to independently image the topography and local electrocatalytic activity with 15-nm spatial resolution. We employed this operando microscopy technique to map out the oxygen evolution activity of a semi-2D nickel oxide nanosheet. The improved resolution and sensitivity enables us to distinguish the higher activities of the materials' edges from that of the fully coordinated surfaces in operando The combination of spatially resolved electrochemical information with state-of-the-art electron tomography, that unravels the 3D complexity of the edges, and ab initio calculations allows us to reveal the intricate coordination dependent activity along individual edges of the semi-2D material that is not achievable by other methods. The comparison of the simulated line scans to the experimental data suggests that the catalytic current density at the nanosheet edge is ∼200 times higher than that at the NiO basal plane.
The effect of the addition of an ionic dopant to calcium phosphates for biomedical applications requires specific research due to the essential roles played in such processes. In the present study, the mechanical and biological properties of Ni-doped hydroxyapatite (HA) and Ni-doped HA mixed with graphene nanoplatelets (GNPs) were evaluated. Ni (3wt.% and 6wt.%)-doped HA was synthesized using a continuous precipitation method and calcined at 900°C for 1h. The GNP (0.5-2wt.%)-reinforced 6% Ni-doped HA (Ni6) composite was prepared using rotary ball milling for 15h. The sintering process was performed using hot isostatic pressing at processing conditions of 1150°C and 160MPa with a 1-h holding time. The results indicated that the phase compositions and structural features of the products were noticeably affected by the Ni and GNPs. The mechanical properties of Ni6 and 1.5Ni6 were increased by 55% and 75% in hardness, 59% and 163% in fracture toughness and 120% and 85% in elastic modulus compared with monolithic HA, respectively. The in-vitro biological behavior was investigated using h-FOB osteoblast cells in 1, 3 and 5days of culture. Based on the osteoblast results, the cytotoxicity of the products was indeed affected by the Ni doping. In addition, the effect of GNPs on the growth and proliferation of osteoblast cells was investigated in Ni6 composites containing different ratios of GNPs, where 1.5wt.% was the optimum value.
The presence of heavy metals in the environment results in a number of environmental problems. In this study, the potential of Rambai stem (Baccaurea motleyana) of Malaysia in removing nickel ion from aqueous solution has been evaluated. The raw material used in this study was obtained from local orchard. The collected material passed through physical preparation and treatment process. The adsorbent was thoroughly characterized by SEM, EDX and FTIR studies. The effect of initial nickel concentration, dosage of adsorbent and pH on the adsorption process were investigated. The highest adsorption capacity obtained at weak acidic conditions (pH 4-5) when dosage and initial concentrations are 0.1 and 30 ppm respectively. The percentage of removal of nickel from the solution was found to be 51%. The experimental data fitted well in Freundlich isotherms indicating the adsorption of nickel on Rambai stem (Baccaurea motleyana) followed heterogenous surface phenomena.
Lansium domesticum peel (LDP), a waste material generated from the fruit consumption, was evaluated as a biosorbent for nickel removal from aqueous media. The effects of dosage, contact time, initial pH, initial concentration and temperature on the biosorption process were investigated in batch experiments. Equilibrium data were fitted by the Langmuir, Freundlich, Temkin and Dubinin-Radushkevich models using nonlinear regression method with the best-fit model evaluated based on coefficient of determination (R(2)) and Chi-square (χ(2)). The best-fit isotherm was found to be the Langmuir model exhibiting R(2) very close to unity (0.997-0.999), smallest χ(2) (0.0138-0.0562) and largest biosorption capacity (10.1mg/g) at 30°C. Kinetic studies showed that the initial nickel removal was rapid with the equilibrium state established within 30min. Pseudo-second-order model was the best-fit kinetic model indicating the chemisorption nature of the biosorption process. Further data analysis by the intraparticle diffusion model revealed the involvement of several rate-controlling steps such as boundary layer and intraparticle diffusion. Thermodynamically, the process was exothermic, spontaneous and feasible. Regeneration studies indicated that LDP biosorbent could be regenerated using hydrochloric acid solution with up to 85% efficiency. The present investigation proved that LDP having no economic value can be used as an alternative eco-friendly biosorbent for remediation of nickel contaminated water.
Ninety-nine samples of common Chinese medicines were purchased from Chinese medical shops in Singapore and Malaysia and analyzed for mercury, lead, copper, cadmium, cobalt, iron, and nickel. The majority of these medicines were manufactured in China, Hong Kong, and Malaysia. A few of them were of Singapore and Taiwan origin. Atomic absorption method (both flame and flameless) was used for the analyses. Mercury was found to be present in high concentrations in several of the medicines that were for oral consumption.
Industrial operations, domestic and agricultural activities worldwide have had major problems with various contaminants caused by environmental pollution. Heavy metal pollution in wastewater also a prominent issue; therefore, a well built and economical treatment technology is demanded for pollution-free wastewater. The present work emphasized pure cellulose extracted from jute fiber and further modification was performed by a free radical grafting reaction, which resulted in poly(methyl acrylate) (PMA)-grafted cellulose and poly(acrylonitrile)-grafted cellulose. Subsequently, poly(hydroxamic acid) and poly(amidoxime) ligands were prepared from the PMA-grafted cellulose and PAN-grafted cellulose, respectively. An adsorption study was performed using the desired ligands with heavy metals such as copper, cobalt, chromium and nickel ions. The binding capacity (qe) with copper ions for poly(hydroxamic acid) is 352 mg g-1 whereas qe for poly(amidoxime) ligand it was exhibited as 310 mg g-1. Other metal ions (chromium, cobalt and nickel) show significance binding properties at pH 6. The Langmuir and Freundlich isotherm study was also performed. The Freundlich isotherm model showed good correlation coefficients for all metal ions, indicating that multiple-layers adsorption was occurred by the polymer ligands. The reusability was evaluated and the adsorbents can be reused for 7 cycles without significant loss of removal performance. Both ligands showed outstanding metals removal capacity from the industrial wastewater as such 98% of copper can be removed from electroplating wastewater and other metals (cobalt, chromium, nickel and lead) can also be removed up to 90%.
Objectives: To assess and compare the oral health-related quality of life (OHRQoL) of orthodontic patients who had and had not undergone micro-osteoperforations (MOPs) during orthodontic space closure. Methods: 27 orthodontic patients with fixed appliance who are undergoing orthodontic space closure with Niti coil springs were given the validated short version of the Oral Health Impact Profile (Malaysia) Questionnaire (S-OHIP) which was available in both Bahasa Melayu and English, containing 14 items. 17 patients underwent MOPs (MOP group) while 10 patients did not (control). Additive scores (ADD) were calculated by summing the response codes for the 14 items and simple count scores (SC) were calculated by a count of the number of items reported as occurring ‘quite often’ and ‘very often’. Results: A total of 24 patients responded to the questionnaire, with a response rate of 88.9%, and they comprised of 79.2% females and 20.8% males. There is no significant difference in the mean ADD (p = 0.347) and mean SC (p = 0.446) across both groups. Conclusions: The reported oral health-related quality of life is similar for orthodontic patients who did and did not undergo MOPs.
The enhancement of microwave absorbing properties in nickel zinc ferrite (Ni0.5Zn0.5Fe2O4) via multiwall carbon nanotubes (MWCNT) growth is studied in this research work. Ni0.5Zn0.5Fe2O4 was initially synthesized by mechanical alloying followed by sintering at 1200 °C and the microstructural, electromagnetic and microwave characteristics have been scrutinized thoroughly. The sintered powder was then used as a catalyst to grow MWCNT derived from chemical vapor deposition (CVD) method. The sample was mixed with epoxy resin and a hardener for preparation of composites. The composite of multi-walled carbon nanotubes/Ni0.5Zn0.5Fe2O4 shown a maximum reflection loss (RL) of -19.34 dB at the frequency and bandwidth of 8.46 GHz and 1.24 GHz for an absorber thickness of 3 mm for losses less than -10 dB. This acquired result indicates that multi-walled carbon nanotubes/Ni0.5Zn0.5Fe2O4 could be used as a microwave absorber application in X-band.
Heavy metal ions contamination has become more serious which is caused
by the releasing of toxic waterfrom industrial area and landfill that are very
harmful to all living organism especially human and can even cause death
if contaminated in small amount of heavy metal concentration. Currently,
peoples are using classic method namely electrochemical treatment,
chemical oxidation/reduction, chemical precipitation and reverse osmosis
to eliminate the metal ions from toxic water. Unfortunately, these methods
are costly and not environmentally friendly as compared to bioadsorption
method, where agricultural waste is used as biosorbent to remove heavy
metals. Two types of agricultural waste used in this research namely oil
palm mesocarp fiber (Elaesis guineensis sp.) (OPMF) and mangrove bark
(Rhizophora apiculate sp.) (MB) biomass. Through chemical treatment,
the removal efficiency was found to improve. The removal efficiency is
examined based on four specification namely dosage, of biosorbent to
adsorb fourtypes of metalsion explicitly nickel, lead, copper, and chromium.
The research has found that the removal efficiency of MB was lower than
OPMF; whereas, the multiple metals ions removal efficiency decreased in
the order of Pb2+ > Cu2+ > Ni2+ > Cr2+.
A sustainable and stable supported liquid membrane (SLM) extraction of nickel was developed via impregnation of sustainable liquid membrane in the composite membrane support consisting of polyvinylidene fluoride (PVDF) and sulfonated poly (ether ether ketone) (SPEEK). Bis-2-ethylhexyl phosphate (D2EHPA), 1-octanol, refined palm oil and sulfuric acid were employed as extractant, synergist extractant, diluent and strippant, respectively. Variables studied including effect of refined palm oil compositions as well as the configurations and thicknesses of SPEEK. Lifespan of SLM was evaluated by recycling the composite membrane support. Results revealed that upon using 100% refined palm oil, about 100% of nickel was extracted and recovered in 10 and 14 h, respectively. Composite SPEEK/PVDF stabilized SLM by reducing liquid membrane loss from 47 to 23% upon applying SPEEK at the feed side of PVDF support. High permeability and flux values were obtained at 9.26 x 10-4 cms-1 and 6.48 x 10-7 molcm-2s-1 when increasing SPEEK thickness from 0.025 to 0.055 mm, respectively. The lifespan of SLM was extended up to ninth cycles with low weight loss percentage of the impregnated composite membrane (8%). In conclusion, the SPEEK/PVDF impregnated with refined palm oil has improved the stability of SLM extraction of nickel ions from industrial wastewater.
Introduction: Coated archwires improve aesthetics during orthodontic treatment. However, little is known regarding
their clinical benefit. This randomised controlled trial (RCT) compared the tooth alignment (TA), coating loss (CL),
colour change (∆E*), and patient perception of coated archwires with their controls. Details of ∆E* and perception were reported in the second part of the articles. Methods: This RCT was done at three centres. Participants
were randomised to receive one of four treatment interventions using 0.014” superelastic coated nickel-titanium
archwires from Orthocare, RMO, G&H, and conventional uncoated 3M Unitek® archwires. These archwires were
ligated during bonding and collected after eighth week and questionnaires were distributed to participants in the
experimental groups only. After removal, TA and CL were measured using Little’s Irregularity Index and Autodesk®
AutoCAD® software, respectively. At the time of this preliminary reporting, 84 participants had completed the trial. Two archwires fractured and were excluded. Therefore, 166 archwires (n = 166) were analysed. Results: Only
non-extraction cases showed statistically significant differences in TA change between all groups (p = 0.005) and
RMO showed significantly lowest mean of TA (1.5 mm). RMO and Orthocare showed significant TA change in the
upper and lower arches (p = 0.037, 0.048). CL was found to be insignificant for both extraction and non-extraction
cases (p >0.05). Comparison between upper and lower arches revealed no significant difference in TA and CL in all
groups (p >0.05). Conclusion: From this preliminary analysis, Orthocare provides better TA in non-extraction cases
despite highest percentage of coating loss.
H2S gas when exposed to metal can be responsible for both general and localized corrosion, which depend on several parameters such as H2S concentration and the corrosion product layer formed. Therefore, the formation of passive film on 316L steel when exposed to H2S environment was investigated using several analysis methods such as FESEM and STEM/EDS analyses, which identified a sulfur species underneath the porous structure of the passive film. X-ray photoelectron spectroscopy analysis demonstrated that the first layer of CrO3 and Cr2O3 was dissolved, accelerated by the presence of H2S-Cl-. An FeS2 layer was formed by incorporation of Fe and sulfide; then, passivation by Mo took place by forming a MoO2 layer. NiO, Ni(OH)2, and NiS barriers are formed as final protection for 316L steel. Therefore, Ni and Mo play an important role as a dual barrier to maintain the stability of 316L steel in high pH2S environments. For safety concern, this paper is aimed to point out a few challenges dealing with high partial pressure of H2S and limitation of 316L steel under highly sour condition for the oil and gas production system.
Nickel-based catalysts play an important role in the hydrogen-free deoxygenation for the production of biofuel. The yield and quality of the biofuel are critically affected by the physicochemical properties of NiO supported on nanosized zeolite Y (Y65, crystal size of 65 nm). Therefore, 10 wt% NiO supported on Y65 synthesized by using impregnation (IM) and deposition-precipitation (DP) methods were investigated. It was found that preparation methods have a significant effect on the deoxygenation of triolein. The initial rate of the DP method (14.8 goil·h-1) was 1.5 times higher than that of the IM method (9.6 goil·h-1). The DP-Y65 showed the best deoxygenation performance with a 80.0% conversion and a diesel selectivity of 93.7% at 380 °C within 1 h. The outstanding performance from the DP method was due to the smaller NiO particle size (3.57 ± 0.40 nm), high accessibility (H.F value of 0.084), and a higher Brönsted to Lewis acidity (B/L) ratio (0.29), which has improved the accessibility and deoxygenation ability of the catalyst. The NH4+ released from the decomposition of the urea during the DP process increased the B/L ratio of zeolite NaY. As a result, the pretreatment to convert Na-zeolite to H-zeolite in a conventional zeolite synthesis can be avoided. In this regard, the DP method offers a one-pot synthesis to produce smaller NiO-supported nanosized zeolite NaY with a high B/L ratio, and it managed to produce a higher yield with selectivity towards green diesel via deoxygenation under a hydrogen-free condition.
Many recent studies focused on the patient’s safety from the administration of gadolinium-based contrast agents (GBCAs), their concentration, the dose of administration and their effects on the image quality. The present study was aimed at evaluating the effects of reduced GBCAs (gadobutrol and gadoterate meglumine) volume on the image quality by using phantoms. Eight (8) human brain mimicking phantom made of nickel chloride (NiCl2) doped agarose gel were added with 0.00500 ml (100% volume), 0.00350 ml (75% volume), 0.00250 ml (50% volume) and 0.00125 ml (25% volume) of gadobutrol, 0.0100 ml (100% volume), 0.0075 ml (75% volume), 0.0050 ml (50% volume) and 0.0025 ml (25% volume) of gadoterate meglumine. The phantoms were scanned using a 1.5-T and a 3 T-MRI system. Signal-to-noise ratio (SNR) and the contrast agents enhancement were evaluated quantitatively and qualitatively. The 50% volume of gadobutrol and gadoterate meglumine at 3 T showed greater enhancement when compared with 50% and 100% volumes of gadobutrol and gadoterate meglumine at 1.5 T. It can be concluded that the volume of gadobutrol and gadoterate meglumine contrast agents can be reduced when using a higher field system
Magnetic nanoparticles in the hollow region of carbon nanotubes have attraction due to their changing physical electrical and magnetic properties. Nickel zinc ferrite plays an important role in many applications due to its superior magnetic properties. Ni0.8Zn0.2Fe2O4 single crystals were encapsulated in multiwall carbon nanotubes (MWCNTs). The magnetic nano crystals were prepared using a sol-gel self combustion method at the sintering temperature of 750 degrees C and were characterized by XRD, FESEM, TEM and VSM. Initial permeability, Q-factor and relative loss factor were measured by impedance vector network analyzer. XRD patterns were used for the phase identification. FESEM images show morphology and dimensions of the grains of Ni0.8Zn0.2Fe2O4 single crystals and Ni0.8Zn0.2Fe2O4 single crystals in MWCNTs. TEM images were used to investigate single crystal and encapsulation of Ni0.8Zn0.2Fe2O4 single crystals in the MWCNTs. VSM results confirmed super paramagnetic behaviour of encapsulated Ni0.8Zn0.2Fe2O4 single crystals. It was also attributed that encapsulated Ni0.8Zn0.2Fe2O4 single crystals in MWCNTs showed a higher initial permeability (51.608), Q-factor (67.069), and low loss factor (0.0002) as compared to Ni0.8Zn0.2Fe2O4 single crystals. The new encapsulated Ni0.8Zn0.2Fe2O4 single crystals in the MWCNTs may have potential applications in electronic and medical industries.
This study aims to determine the prevalence of hand-held ProTaper® files system among UKM final year dental undergraduates and to assess their perception in performing endodontic treatments.
Methods: 85 final year dental students from 2006/2007 academic session participated in the questionnaire survey. All students underwent didactic endodontic teaching of conventional stainless steel files throughout a 2-year course and a 2-day ProTaper® hand files seminar on canal preparation. Each student had a total of 6 months clinical period before the survey was distributed to the subjects and returned for data analysis.
Results: A 100% response rate was received. About 58.8% (n=50) used hand ProTaper routinely while 41.2% claimed themselves as non-users. Amongst the users, 52.5% were moderate users and about 33.6% were frequent users. Tooth type and size of canals were the selected criteria for file use. Majority of users used ProTaper® hand for posterior teeth and regarded it as user friendly. Although almost all users expressed concern of instrument fracture during use, very few did break. Procedural errors were not experienced by 51.3% users.
Conclusion: About 2/3rd majority of UKM undergraduate dental students use ProTaper® hand-held system as an alternative for canal preparation. Procedural errors were perceived to occur much less when using the NiTi files. The system can be initiated to novice users and can be taught as part of endodontic curricula.