METHODOLOGY: The synthesized metal complexes were characterized by physicochemical and spectral investigation (UV, IR, 1H and 13C-NMR) and were further evaluated for their antimicrobial (tube dilution) and anticancer (SRB assay) activities. In addition, the corrosion inhibition potential was determined by electrochemical impedance spectroscopy (EIS) technique.
RESULTS AND DISCUSSION: Antimicrobial screening results found complexes (MC1-MC4) to exhibit less antibacterial activity against the tested bacterial species compared to ofloxacin while the complex MC1 exhibited greater antifungal activity than the fluconazole. The anticancer activity results found the synthesized Schiff base and its metal complexes to elicit poor cytotoxic activity than the standard drug (5-fluorouracil) against HCT116 cancer cell line. Metal complex MC2 showed more corrosion inhibition efficiency with high Rct values and low Cdl values.
CONCLUSION: From the results, we can conclude that complexes MC1 and MC2 may be used as potent antimicrobial and anticorrosion agents, respectively.
RESULTS: The calibration curve showed a linear range between 0.01 fM to 0.01 nM with a limit of detection 0.05 fM. The results showed that the optimum concentration for DNA probe was 5 µM. The good performance of the proposed biosensor was achieved through hybridization of DNA probe-modified SPCE with extracted DNA from clinical samples.
CONCLUSIONS: According to the investigated results, this biosensor can be introduced as a proprietary, accurate, sensitive, and rapid diagnostic method of HPV 18 in the polymerase chain reaction (PCR) of real samples.
METHODOLOGY: A prospective observational study was conducted by inviting pre-dialysis CKD patients. Fluid overload was assessed by BIS.
RESULTS: A total of 312 CKD patients with mean eGFR 24.5 ± 11.2 ml/min/1.73 m2were enrolled. Based on OH value ≥7 %, 135 (43.3 %) patients were hypervolemic while euvolemia was observed in 177 (56.7 %) patients. Patients were categorized in different regions of hydration reference plot (HRP) generated by BIS i.e., 5.1 % in region-N (normal BP and fluid status), 20.5 % in region I (hypertensive with severe fluid overload), 29.5 % in region I-II (hypertensive with mild fluid overload), 22 % in region II (hypertensive with normohydration), 10.2 % in region III (underhydration with normal/low BP) and 12.5 % in region IV (normal BP with severe fluid overload). A total of 144 (46 %) patients received diuretics on basis of physician assessment of BP and edema. Maximum diuretics 100 (69.4 %) were prescribed in patients belonging to regions I and I-II of HRP. Interestingly, a similar number of diuretic prescriptions were observed in region II (13 %) and region IV (12 %). Surprisingly, 7 (4.9 %) of patients in region III who were neither hypervolemic nor hypertensive were also prescribed with diuretics.
CONCLUSION: BIS can aid clinicians to categorize CKD patients on basis of their fluid status and provide individualized pharmacotherapy to manage hypertensive CKD patients.