Displaying publications 61 - 80 of 139 in total

Abstract:
Sort:
  1. Ahmad AF, Abbas Z, Obaiys SJ, Ibrahim N, Hashim M, Khaleel H
    PLoS One, 2015;10(10):e0140505.
    PMID: 26474301 DOI: 10.1371/journal.pone.0140505
    Bio-composites of oil palm empty fruit bunch (OPEFB) fibres and polycaprolactones (PCL) with a thickness of 1 mm were prepared and characterized. The composites produced from these materials are low in density, inexpensive, environmentally friendly, and possess good dielectric characteristics. The magnitudes of the reflection and transmission coefficients of OPEFB fibre-reinforced PCL composites with different percentages of filler were measured using a rectangular waveguide in conjunction with a microwave vector network analyzer (VNA) in the X-band frequency range. In contrast to the effective medium theory, which states that polymer-based composites with a high dielectric constant can be obtained by doping a filler with a high dielectric constant into a host material with a low dielectric constant, this paper demonstrates that the use of a low filler percentage (12.2%OPEFB) and a high matrix percentage (87.8%PCL) provides excellent results for the dielectric constant and loss factor, whereas 63.8% filler material with 36.2% host material results in lower values for both the dielectric constant and loss factor. The open-ended probe technique (OEC), connected with the Agilent vector network analyzer (VNA), is used to determine the dielectric properties of the materials under investigation. The comparative approach indicates that the mean relative error of FEM is smaller than that of NRW in terms of the corresponding S21 magnitude. The present calculation of the matrix/filler percentages endorses the exact amounts of substrate utilized in various physics applications.
    Matched MeSH terms: Finite Element Analysis*
  2. Mensah EE, Abbas Z, Azis RS, Khamis AM
    Materials (Basel), 2019 May 24;12(10).
    PMID: 31137736 DOI: 10.3390/ma12101696
    The purpose of this study was to synthesize high-quality recycled α-Fe2O3 to improve its complex permittivity properties by reducing the particles to nanosize through high energy ball milling. Complex permittivity and permeability characterizations of the particles were performed using open-ended coaxial and rectangular waveguide techniques and a vector network analyzer. The attenuation characteristics of the particles were analyzed with finite element method (FEM) simulations of the transmission coefficients and electric field distributions using microstrip model geometry. All measurements and simulations were conducted in the 8-12 GHz range. The average nanoparticle sizes obtained after 8, 10 and 12 h of milling were 21.5, 18, and 16.2 nm, respectively, from an initial particle size of 1.73 µm. The real and imaginary parts of permittivity increased with reduced particle size and reached maximum values of 12.111 and 0.467 at 8 GHz, from initial values of 7.617 and 0.175, respectively, when the particle sizes were reduced from 1.73 µm to 16.2 nm. Complex permeability increased with reduced particle size while the enhanced absorption properties exhibited by the nanoparticles in the simulations confirmed their ability to attenuate microwaves in the X-band frequency range.
    Matched MeSH terms: Finite Element Analysis
  3. Mehrabi MH, Suhatril M, Ibrahim Z, Ghodsi SS, Khatibi H
    PLoS One, 2017;12(6):e0176480.
    PMID: 28570657 DOI: 10.1371/journal.pone.0176480
    Conventional seismic rehabilitation methods may not be suitable for some buildings owing to their high cost and time-consuming foundation work. In recent years, viscoelastic dampers (VEDs) have been widely used in many mid- and high-rise buildings. This study introduces a viscoelastic passive control system called rotary rubber braced damper (RRBD). The RRBD is an economical, lightweight, and easy-to-assemble device. A finite element model considering nonlinearity, large deformation, and material damage is developed to conduct a parametric study on different damper sizes under pushover cyclic loading. The fundamental characteristics of this VED system are clarified by analyzing building structures under cyclic loading. The result show excellent energy absorption and stable hysteresis loops in all specimens. Additionally, by using a sinusoidal shaking table test, the effectiveness of the RRBD to manage the response displacement and acceleration of steel frames is considered. The RRBD functioned at early stages of lateral displacement, indicating that the system is effective for all levels of vibration. Moreover, the proposed damper shows significantly better performance in terms of the column compression force resulting from the brace action compared to chevron bracing (CB).
    Matched MeSH terms: Finite Element Analysis
  4. Khoo W, Chung SM, Lim SC, Low CY, Shapiro JM, Koh CT
    Data Brief, 2019 Dec;27:104718.
    PMID: 31763388 DOI: 10.1016/j.dib.2019.104718
    Data in this article are supplementary to the corresponding research article [1]. Morphological features of homogeneous and graded nanofibrous electrospun gelatin scaffolds were observed using scanning electron microscopy. Microstructural properties including fiber diameter and pore size were determined via image analysis, using ImageJ. Uniaxial tensile and fracture tests were performed on both homogeneous and graded scaffolds using a universal testing machine. Stress-strain curves of all scaffolds are presented. Computing software, MATLAB, was used to design fibrous networks with thickness-dependent density and alignment gradients (DAG). Finite element analysis software, Abaqus, was used to determine the effect of the number of layers on the fracture properties of DAG multilayer scaffolds.
    Matched MeSH terms: Finite Element Analysis
  5. Yahya N, Akhtar MN, Nasir N, Shafie A, Jabeli MS, Koziol K
    J Nanosci Nanotechnol, 2012 Oct;12(10):8100-9.
    PMID: 23421185
    In seabed logging the magnitude of electromagnetic (EM) waves for the detection of a hydrocarbon reservoir in the marine environment is very important. Having a strong EM source for exploration target 4000 m below the sea floor is a very challenging task. A new carbon nanotubes (CNT) fibres/aluminium based EM transmitter is developed and NiZn ferrite as magnetic feeders was used in a scaled tank to evaluate the presence of oil. Resistive scaled tank experiments with a scale factor of 2000 were carried out. X-ray Diffraction (XRD), Raman Spectroscopy and Field Emission Scanning Electron Microscope (FESEM) were done to characterize the synthesized magnetic feeders. Single phase Ni0.76Mg0.04Zn0.2Fe2O4, obtained by the sol-gel method and sintered at 700 degrees C in air, has a [311] major peak. FESEM results show nanoparticles with average diameters of 17-45 nm. Samples which have a high Q-factor (approximately 50) was used as magnetic feeders for the EM transmitter. The magnitude of the EM waves of this new EM transmitter increases up to 400%. A curve fitting method using MATLAB software was done to evaluate the performance of the new EM transmitter. The correlation value with CNT fibres/aluminium-NiZnFe2O4 base transmitter shows a 152.5% increase of the magnetic field strength in the presence of oil. Modelling of the scale tank which replicates the marine environment was done using the Finite Element Method (FEM). In conclusion, FEM was able to delineate the presence of oil with greater magnitude of E-field (16.89%) and the B field (4.20%) due to the new EM transmitter.
    Matched MeSH terms: Finite Element Analysis
  6. Al-Fasih MY, Mohamad ME, Ibrahim IS, Ahmad Y, Ariffin MAM, Sarbini NN, et al.
    PLoS One, 2021;16(5):e0252050.
    PMID: 34015027 DOI: 10.1371/journal.pone.0252050
    Effects of different surface textures on the interface shear strength, interface slip, and failure modes of the concrete-to-concrete bond are examined through finite element numerical model and experimental methods in the presence of the horizontal load with 'push-off' technique under different normal stresses. Three different surface textures are considered; smooth, indented, and transversely roughened to finish the top surfaces of the concrete bases. In the three-dimensional modeling via the ABAQUS solver, the Cohesive Zone Model (CZM) is used to simulate the interface shear failure. It is observed that the interface shear strength increases with the applied normal stress. The transversely roughened surface achieves the highest interface shear strength compared with those finished with the indented and smooth approaches. The smooth and indented surfaces are controlled by the adhesive failure mode while the transversely roughened surface is dominated by the cohesive failure mode. Also, it is observed that the CZM approach can accurately model the interface shear failure with 3-29% differences between the modeled and the experimental test findings.
    Matched MeSH terms: Finite Element Analysis
  7. Lim WTH, Ooi EH, Foo JJ, Ng KH, Wong JHD, Leong SS
    Ultrasonics, 2023 Aug;133:107046.
    PMID: 37247461 DOI: 10.1016/j.ultras.2023.107046
    The application of ultrasound shear wave elastography for detecting chronic kidney disease, namely renal fibrosis, has been widely studied. A good correlation between tissue Young's modulus and the degree of renal impairment has been established. However, the current limitation of this imaging modality pertains to the linear elastic assumption used in quantifying the stiffness of renal tissue in commercial shear wave elastography systems. As such, when underlying medical conditions such as acquired cystic kidney disease, which may potentially influence the viscous component of renal tissue, is present concurrently with renal fibrosis, the accuracy of the imaging modality in detecting chronic kidney disease may be affected. The findings in this study demonstrate that quantifying the stiffness of linear viscoelastic tissue using an approach similar to those implemented in commercial shear wave elastography systems led to percentage errors as high as 87%. The findings presented indicate that use of shear viscosity to detect changes in renal impairment led to a reduction in percentage error to values as low as 0.3%. For cases in which renal tissue was affected by multiple medical conditions, shear viscosity was found to be a good indicator in gauging the reliability of the Young's modulus (quantified through a shear wave dispersion analysis) in detecting chronic kidney disease. The findings show that percentage error in stiffness quantification can be reduced to as low as 0.6%. The present study demonstrates the potential use of renal shear viscosity as a biomarker to improve the detection of chronic kidney disease.
    Matched MeSH terms: Finite Element Analysis
  8. Chen J, Ahmad R, Suenaga H, Li W, Swain M, Li Q
    J Biomech, 2015 Feb 5;48(3):512-9.
    PMID: 25560272 DOI: 10.1016/j.jbiomech.2014.11.043
    Although implant-retained overdenture allows edentulous patients to take higher occlusal forces than the conventional complete dentures, the biomechanical influences have not been explored yet. Clinically, there is limited knowledge and means for predicting localized bone remodelling after denture treatment with and without implant support. By using finite element (FE) analysis, this article provides an in-silico approach to exploring the treatment effects on the oral mucosa and potential resorption of residual ridge under three different denture configurations in a patient-specific manner. Based on cone beam computerized tomography (CBCT) scans, a 3D heterogeneous FE model was created; and the supportive tissue, mucosa, was characterized as a hyperelastic material. A measured occlusal load (63N) was applied onto three virtual models, namely complete denture, two and four implant-retained overdentures. Clinically, the bone resorption was measured after one year in the two implant-retained overdenture treatment. Despite the improved stability and enhanced masticatory function, the implant-retained overdentures demonstrated higher hydrostatic stress in mucosa (43.6kPa and 39.9kPa for two and four implants) at the posterior ends of the mandible due to the cantilever effect, than the complete denture (33.4kPa). Hydrostatic pressure in the mucosa signifies a critical indicator and can be correlated with clinically measured bone resorption, pointing to severer mandibular ridge resorption posteriorly with implant-retained overdentures. This study provides a biomechanical basis for denture treatment planning to improve long-term outcomes with minimal residual ridge resorption.
    Matched MeSH terms: Finite Element Analysis
  9. Zhong J, Guazzato M, Chen J, Zhang Z, Sun G, Huo X, et al.
    J Mech Behav Biomed Mater, 2020 02;102:103490.
    PMID: 31877512 DOI: 10.1016/j.jmbbm.2019.103490
    Mechanical failure of zirconia-based full-arch implant-supported fixed dental prostheses (FAFDPs) remains a critical issue in prosthetic dentistry. The option of full-arch implant treatment and the biomechanical behaviour within a sophisticated screw-retained prosthetic structure have stimulated considerable interest in fundamental and clinical research. This study aimed to analyse the biomechanical responses of zirconia-based FAFDPs with different implant configurations (numbers and distributions), thereby predicting the possible failure sites and the optimum configuration from biomechanical aspect by using finite element method (FEM). Five 3D finite element (FE) models were constructed with patient-specific heterogeneous material properties of mandibular bone. The results were reported using volume-averaged von-Mises stresses (σVMVA) to eliminate numerical singularities. It was found that wider placement of multi-unit copings was preferred as it reduces the cantilever effect on denture. Within the limited areas of implant insertion, the adoption of angled multi-unit abutments allowed the insertion of oblique implants in the bone and wider distribution of the multi-unit copings in the prosthesis, leading to lower stress concentration on both mandibular bone and prosthetic components. Increasing the number of supporting implants in a FAFDPs reduced loading on each implant, although it may not necessarily reduce the stress concentration in the most posterior locations significantly. Overall, the 6-implant configuration was a preferable configuration as it provided the most balanced mechanical performance in this patient-specific case.
    Matched MeSH terms: Finite Element Analysis
  10. Jain P, Sing Ngie DC, Lim SF, Lim BH
    Int J Artif Organs, 2020 Oct 13.
    PMID: 33045876 DOI: 10.1177/0391398820964483
    Pedicular arthrodesis is the traditional procedure in terms of increase in the biomechanical stability with higher fixation rate. The current work aims to identify the effect of three spinal pedicle screws considering cortical and cancellous degeneracy condition. Lumbar section L2-L3 is utilized and various load and moment conditions were applied to depict the various biomechanical parameters for selection of suitable screw. Three dimensional model is considered in finite element analysis to identify the various responses of pedicle screw at bone screw juncture. Computed tomography (CT) images of a healthy male were considered to generate the finite element vertebral model. Generated intact model was further utilized to develop the other implanted models of degenerated cortical and cancellous bone models. The three fused instrumented models with different cortical and cancellous degeneracy conditions were analyzed in finite element analysis. The results were obtained as stress pattern at bone screw boundary and intervertebral disc stress. FE simulated results represents significant changes in the von Mises stress due to various load and moment conditions on degenerated bones during different body movement conditions. Results have shown that among all pedicle screws, the 6.0 mm diameter screw reflects very less stress values at the juncture. Multiple results on biomechanical aspects obtained during the FE study can be considered to design a new stabilization device and may be helpful to plan surgery of critical sections.
    Matched MeSH terms: Finite Element Analysis
  11. Kwan Z, Khairu Najhan NN, Yau YH, Luximon Y, M Nor F
    Int J Numer Method Biomed Eng, 2020 11;36(11):e3390.
    PMID: 32735083 DOI: 10.1002/cnm.3390
    A realistic three-dimensional (3D) computational model of skin flap closures using Asian-like head templates from two different genders, male and female, has been developed. The current study aimed to understand the biomechanics of the local flap designs along with the effect of wound closures on the respective genders. Two Asian head templates from opposite genders were obtained to use as base models. A third-order Yeoh hyperelastic model was adapted to characterize as skin material properties. A single layer composed of combined epidermis and dermis was considered, and the models were thickened according to respective anatomical positions. Each model gender was excised with a fixed defect size which was consequently covered by three different local flap designs, namely advancement, rotation, and rhomboid flaps. Post-operative simulation presented various scenarios of skin flap closures. Rotation and rhomboid flaps demonstrated maximal tension at the apex of the flap for both genders as well as advancement flap in the female face model. However, advancement flap closure in the male face model was presented otherwise. Yet, the deformation patterns and the peak tension of the discussed flaps were consistent with conventional local flap surgery. Moreover, male face models generated higher stresses compared to the female face models with a 70.34% mean difference. Overall, the skin flap operations were executed manually, and the designed surgery model met the objectives successfully while acknowledging the study limitations. NOVELTY FILE: 3D head templates were considered to address the gap as 3D face models were uncommonly employed in understanding the biomechanics of the local flaps realistically. Most of the existing studies focus on the 2D and 3D planar geometry in their models. As gender comparison has yet to be addressed, we intended to fill this gap by exploring the stress contours of the local flap designs in different genders. Create a 3D face model from two opposite genders which is capable of simulating closure of wounds using local flaps with a focus on advancement, rotation, and rhomboid flaps.
    Matched MeSH terms: Finite Element Analysis
  12. M.N.M. Nawi, A.A. Manaf, M.R. Arshad
    ASM Science Journal, 2013;7(2):144-151.
    MyJurnal
    This article uses finite volume and finite element methods for optimization of the artificial hair cell sensor. The performance of the sensor was investigated for different materials such as sicon and polysilicon and by varying hair cell dimensions including width and length. The silicon material which has low young modulus was proposed based on the simulation performance. The performance of the hair cell sensor was achieved by increasing the hair cell length while increasing the width did not significantly influence the performance. The
    performance of the sensor was studied for its viscous force, deflection, von mises stress and sensitivity. From the simulation, the hair cell with a length of 1600 µm and 80 µm width was suggested for the subsequent analysis. Another way to improve the performance was by modifying the hair cell geometry and it was proved that the modified hair cell was more sensitive, based on the deflection. The angle of flow that hit the hair cell also affected the deflection of the sensor where the zero angle flow which was parallel to the substrate was the most effective angle. The limitations of the performance of hair cell for various fluid velocity were also discussed in this paper.
    Matched MeSH terms: Finite Element Analysis
  13. Jamaluddin Mahmud, Ahmad Kamil Hussain, Norzihan Rahimi, Mastura Abdul Rahim
    MyJurnal
    The finite element method is gaining acceptance in predicting mechanical response of various loading configurations and material orientations for failure analysis of composite laminates. Both fabrication of laminate samples and experimental procedures are often expensive and time consuming, and hence impractical, especially during the initial design stage. Finite element analyses require minimal amounts of input data, and the resulting stress and strain distributions can be determined throughout each individual ply. Using ANSYSTM, a commercially available finite element package, failure loads were predicted by simulating a uniaxial tensile loading on HTS40/977-2 Carbon/Epoxy composite with [+/-4512s lamination scheme. Two built-in failure theories in ANSYSTM features, viz., Maximum Stress and Tsai-Wu were applied in the simulation. The stress-strain and load-extension curves for both actual testing and FEA were then compared and the results are in good agreement. This paper is intended for researchers who have used or are considering using ANSYSTM for the prediction of failure in composite materials.
    Matched MeSH terms: Finite Element Analysis
  14. Abdul Wahab AH, Mohamad Azmi NA, Abdul Kadir MR, Md Saad AP
    Int J Artif Organs, 2022 Feb;45(2):200-206.
    PMID: 33645338 DOI: 10.1177/0391398821999391
    Glenoid conformity is one of the important aspects that could contribute to implant stability. However, the optimal conformity is still being debated among the researchers. Therefore, this study aims to analyze the stress distribution of the implant and cement in three types of conformity (conform, non-conform, and hybrid) in three load conditions (central, anterior, and posterior). Glenoid implant and cement were reconstructed using Solidwork software and a 3D model of scapula bone was done using MIMICS software. Constant load, 750 N, was applied at the central, anterior, and posterior region of the glenoid implant which represents average load for daily living activities for elder people, including, walking with a stick and standing up from a chair. The results showed that, during center load, an implant with dual conformity (hybrid) showed the best (Max Stress-3.93 MPa) and well-distributed stress as compared to other conformity (Non-conform-7.21 MPa, Conform-9.38 MPa). While, during eccentric load (anterior and posterior), high stress was located at the anterior and posterior region with respect to the load applied. Cement stress for non-conform and hybrid implant recorded less than 5 MPa, which indicates it had a very low risk to have cement microcracks, whilst, conform implant was exposed to microcrack of the cement. In conclusion, hybrid conformity showed a promising result that could compromise between conform and non-conform implant. However, further enhancement is required for hybrid implants when dealing with eccentric load (anterior and posterior).
    Matched MeSH terms: Finite Element Analysis
  15. Kong SY, Wong LS, Paul SC, Miah MJ
    Polymers (Basel), 2020 Oct 02;12(10).
    PMID: 33023168 DOI: 10.3390/polym12102270
    This paper investigated the static behaviour of glass fibre reinforced polymer (GFRP) built-up hollow and concrete filled built-up beams tested under four-point bending with a span-to-depth ratio of 1.67, therefore focusing their shear performance. Two parameters considered for hollow sections were longitudinal web stiffener and strengthening at the web-flange junction. The experimental results indicated that the GFRP hollow beams failed by web crushing at supports; therefore, the longitudinal web stiffener has an insignificant effect on improving the maximum load. Strengthening web-flange junctions using rectangular hollow sections increased the maximum load by 47%. Concrete infill could effectively prevent the web crushing, and it demonstrated the highest load increment of 162%. The concrete filled GFRP composite beam failed by diagonal tension in the lightweight concrete core. The finite element models adopting Hashin damage criteria yielded are in good agreement with the experimental results in terms of maximum load and failure mode. Based on the numerical study, the longitudinal web stiffener could prevent the web buckling of the slender GFRP beam and improved the maximum load by 136%. The maximum load may be further improved by increasing the thickness of the GFRP section and the size of rectangular hollow sections used for strengthening. It was found that the bond-slip at the concrete-GFRP interface affected the shear resistance of concrete-GFRP composite beam.
    Matched MeSH terms: Finite Element Analysis
  16. Isah BW, Mohamad H
    Sensors (Basel), 2021 Apr 22;21(9).
    PMID: 33922008 DOI: 10.3390/s21092926
    The paper explores the possibility of using high-resolution fiber Bragg grating (FBG) sensing technology for on-specimen strain measurement in the laboratory. The approach provides a means to assess the surface deformation of the specimen, both the axial and radial, through a chain of FBG sensor (C-FBG), in a basic setup of a uniaxial compression test. The method is cost-effective, straightforward and can be commercialized. Two C-FBG; one was applied directly to the sample (FBGBare), and the other was packaged (FBGPack) for ease of application. The approach measures the local strain with high-resolution and accuracy levels that match up to the existing local strain measuring sensors. The approach enables the evaluation of small-strain properties of the specimen intelligently. The finite element model analysis deployed has proven the adaptability of the technique for measuring material deformation. The adhesive thickness and packaging technique have been shown to influence the sensitivity of the FBG sensors. Owing to the relative ease and low-cost of instrumentation, the suggested method has a great potential to be routinely applied for elemental testing in the laboratory.
    Matched MeSH terms: Finite Element Analysis
  17. Mohamed Ibrahim J. Ibrahim, Mohd Zuhri Mohamed Yusoff
    MyJurnal
    This study presents an investigation about the effect of size variation on mechanical
    performance of square core interlocking structures, by using finite element analysis
    (FEA). The material used in this study is flax fibre reinforced polypropylene (PP)
    composite. Abaqus software was used for modelling and visualizing number of six
    interlocking honeycomb structures with different cell sizes and heights. In the first
    analysis, Abaqus/standard was performed on the perfect models by applying quasistatic
    loading to identify the imperfection shape and obtaining the buckling Eigenmodes
    for the models, then the Eigen-modes from abaqus/standard were imported
    to abaqus/explicit to run post-buckling analysis and simulate the overall imperfection
    behaviour of models. The numerical results from the finite element analysis
    simulation were used to plot load-displacement curve to each model. The area under
    the load-displacement curve represents the total absorbed energy, energy absorption
    per unit mass indicates the specific energy absorption, and the highest value of
    specific energy absorption represents the optimum size. The findings demonstrated
    that the square interlocking structure exhibits good energy absorption performance
    in some geometrical cases, and also revealed that the natural fibre composites have
    unique energy absorption capability under quasi-static loads.
    Matched MeSH terms: Finite Element Analysis
  18. Razali MF, Mahmud AS, Mokhtar N
    J Mech Behav Biomed Mater, 2018 Jan;77:234-241.
    PMID: 28954242 DOI: 10.1016/j.jmbbm.2017.09.021
    NiTi arch wires are used widely in orthodontic treatment due to its superelastic and biocompatibility properties. In brackets configuration, the force released from the arch wire is influenced by the sliding resistances developed on the arch wire-bracket contact. This study investigated the evolution of the forces released by a rectangular NiTi arch wire towards possible intraoral temperature and deflection changes. A three dimensional finite element model was developed to measure the force-deflection behavior of superelastic arch wire. Finite element analysis was used to distinguish the martensite fraction and phase state of arch wire microstructure in relation to the magnitude of wire deflection. The predicted tensile and bending results from the numerical model showed a good agreement with the experimental results. As contact developed between the wire and bracket, binding influenced the force-deflection curve by changing the martensitic transformation plateau into a slope. The arch wire recovered from greater magnitude of deflection released lower force than one recovered from smaller deflection. In contrast, it was observed that the plateau slope increased from 0.66N/mm to 1.1N/mm when the temperature was increased from 26°C to 46°C.
    Matched MeSH terms: Finite Element Analysis
  19. Jiading Wang, Tianfeng Gu, Jianbin Wang, Yuanjun Xu, Peng Chen, Muhammad Aqeel Ashraf
    Sains Malaysiana, 2017;46:2049-2059.
    The development degree of fissure water in underground rock is a great trouble to the construction of railway tunnel, which will cause a series of environmental geological problems. Take the surrounding rock-section of the typical red clay in Lvliang-Mt. railway tunnel below the underground water level as an example, several aspects about the red clay surrounding rock will be researched, including pore water pressure, volume moisture content, stress of surrounding rock, vault subsidence and horizontal convergence through the field monitoring. Taking into account the importance of railway tunnel engineering, the large shear test of red clay was carried out at the construction site specially and the reliable situ shear strength parameters of surrounding rock will be obtained. These investigations and field tests helped to do a series of work: Three dimensional finite element numerical model of railway tunnel will be established, the deformation law of the red clay surrounding rock will be investigated, respectively, for the water-stress coupling effect and without considering it, the variation of the pore water pressure during excavation, the influence degree about the displacement field and stress field of water-stress coupling on red clay-rock will be discussed and the mechanism of the surrounding rock deformation will be submitted. Finally, the paper puts forward the feasible drainage scheme of the surrounding rock and the tunnel cathode. The geological environment safety of tunnel construction is effectively protected.
    Matched MeSH terms: Finite Element Analysis
  20. Muhammad Hanif Ramlee
    MyJurnal
    Most orthopaedic cases that involved with bone fracture are normally treated with medical implants. To be noticed that some precautions in terms of biomechanical and biomaterial properties are necessary for a successful post-sur- gery process. The biomechanical evaluation of implants could be carried out using computing and engineering technologies. However, in the computer simulation, some assumptions are needed as the limitations on computer resources and data input. This review focuses on the current method of developing the finite element model for patients with specific values of material properties for lower limb part such as hip, knee and ankle joint. Previous literature was reviewed from which keywords and search engines were identified. In this review, inclusion and exclusion criteria were used to limit the literature search. We reviewed the state-of-the-art in this area and provide recommendations for future research. In conclusion, the previous published reports illustrated different methods to develop numerical models.
    Matched MeSH terms: Finite Element Analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links