Displaying publications 81 - 100 of 125 in total

Abstract:
Sort:
  1. Nemati K, Abu Bakar NK, Abas MR, Sobhanzadeh E, Low KH
    Environ Monit Assess, 2011 May;176(1-4):313-20.
    PMID: 20632089 DOI: 10.1007/s10661-010-1584-3
    A study was carried out to investigate the fractionation of Cd, Cr, Cu, Fe, Mn, Pb, and Zn in shrimp aquaculture sludge from Selangor, Malaysia, using original (unmodified) and modified four-steps BCR (European Community Bureau of Reference, now known as the Standards Measurements and Testing Program) sequential extraction scheme. Step 2 of the unmodified BCR procedure (subsequently called Method A) involves treatment with 0.1 M hydroxylammonium chloride at pH 2, whereas 0.5 M hydroxylammonium chloride at pH 1.5 was used in the modified BCR procedure (subsequently called Method B). Metal analyses were carried out by flame atomic absorption spectrometry. A pseudo-total aqua-regia digest of BCR CRM 701 has also been undertaken for quality assurance purposes. The recovery of Method A for all metals studied ranges from 96.14% to 105.26%, while the recovery for Method B ranges from 95.94% to 122.40%. Our results reveal that Method A underestimated the proportion of metals bound to the easily reducible fraction except for copper. Therefore, the potential mobility of these elements is higher than others. Thus, to use this sludge as a fertilizer we have to first find a remediation for reduction of heavy metal contamination.
    Matched MeSH terms: Chromium/isolation & purification; Chromium/chemistry
  2. Hassan LR, Anouar EH, Bahron H, Abdullah F, Mohd Tajuddin A
    J Biol Inorg Chem, 2020 03;25(2):239-252.
    PMID: 31974764 DOI: 10.1007/s00775-020-01755-6
    Hydroxamic acids [R(CO)N(OH)R'] are flexible compounds for organic and inorganic analyses due to their frailer structures compared to the carboxylic acid. The syntheses and characterization of benzohydroxamic acid (BHA), its CH3-, OCH3-, Cl- para-substituted derivatives and their Cr(III) complexes are reported herein. The metal complexes were synthesized by reacting the hydroxamic acids with chromium(III) chloride hexahydrate in 2:1 molar ratio. The compounds were characterized via melting point, elemental analysis, FTIR, 1H and 13C NMR, TGA, mass spectrometry, molar conductance and UV-Visible. Data analysis suggests that each complex has the Cr(III) center coordinated to the carbonyl and hydroxy oxygen atoms of the hydroxamic acids in bidentate O,O manner and two water molecules to form octahedral geometry. Non-electrolytic behavior of the complexes was shown through their low molar conductivity. Cytotoxicity study against HCT116 and alpha-glucosidase inhibition test revealed that all complexes have higher activity than their parent ligands. Molecular docking study shows that the docking of active complexes is thermodynamically favorable and the inhibition efficiency may depend on the types and the numbers of molecular interactions established in the corresponding stable conformers.
    Matched MeSH terms: Chromium/pharmacology*; Chromium/chemistry
  3. Abdullah N, Yusof N, Abu Shah MH, Wan Ikhsan SN, Ng ZC, Maji S, et al.
    Environ Sci Pollut Res Int, 2019 Jul;26(20):20386-20399.
    PMID: 31102226 DOI: 10.1007/s11356-019-05208-9
    In this present study, adsorptive membranes for Cr(VI) ion removal were prepared by blending polyethersulfone (PES) with hydrous ferric oxide (HFO) nanoparticles (NPs). The effects of HFO NPs to PES weight ratio (0-1.5) on the physicochemical properties of the resultant HFO/PES adsorptive membranes were investigated with respect to the surface chemistry and roughness as well as structural morphologies using different analytical instruments. The adsorptive performance of the HFO NPs/PES membranes was studied via batch adsorption experiments under various conditions by varying solution pH, initial concentration of Cr(VI), and contact time. The results showed that the membrane made of HFO/PES at a weight ratio of 1.0 exhibited the highest adsorption capacity which is 13.5 mg/g. Isotherm and kinetic studies revealed that the mechanism is best fitted to the Langmuir model and pseudo-second-order model. For filtration of Cr(VI), the best promising membranes showed improved water flux (629.3 L/m2 h) with Cr(VI) ion removal of 75%. More importantly, the newly developed membrane maintained the Cr(VI) concentration below the maximum contamination level (MCL) for up to 9 h.
    Matched MeSH terms: Chromium/isolation & purification*; Chromium/chemistry
  4. Kuppusamy G, Kong CK, Segaran GC, Tarmalingam E, Herriman M, Ismail MF, et al.
    Biology (Basel), 2020 Sep 05;9(9).
    PMID: 32899563 DOI: 10.3390/biology9090274
    Black soldier fly (BSF) larva is an attractive animal feed replacer due to its noticeable nutritional content. However, the conventional rearing method often resulted in BSF with undesirably high heavy metal residues that are harmful to animals. In this work, putrefied Sesbania grandiflora (S. Grandiflora) leaves were employed as feed to rear BSF larvae. The resultant BSF prepupae were found to contain 43.5% protein and 16.7% fat, reflecting a comparable protein content and a 2-fold reduction in crude fat than those reared using conventional kitchen waste. Moreover, high quantities of arginine (25.4 g/kg dry matter basis (DM)), carnitine (32.9 g/kg DM), and short-chain fatty acids, including lauric (40.00%), palmitic (19.20%), and oleic (12.10%) acids, have also been noticed in the BSF prepupae. Furthermore, the BSF larvae have been recorded with 0.185 mg/kg chromium, 0.380 mg/kg selenium, and mercury below the detection limit, which is far lower than those reared using conventional kitchen and agricultural wastes (≈1.7 mg/kg chromium, 1.2 mg/kg selenium, and 0.2 mg/kg mercury). Overall, the study shows that the nutritional quality of BSF prepupae is extensively improved when using S. Grandiflora as their feed. The resultant BSF prepupae may serve as an alternative feed for animal rearing.
    Matched MeSH terms: Chromium
  5. Khalid AM, Hossain MS, Ismail N, Khalil NA, Balakrishnan V, Zulkifli M, et al.
    Polymers (Basel), 2020 Dec 30;13(1).
    PMID: 33396583 DOI: 10.3390/polym13010112
    In the present study, magnetic oil palm empty fruits bunch cellulose nanofiber (M-OPEFB-CNF) composite was isolated by sol-gel method using cellulose nanofiber (CNF) obtained from oil palm empty fruits bunch (OPEFB) and Fe3O4 as magnetite. Several analytical methods were utilized to characterize the mechanical, chemical, thermal, and morphological properties of the isolated CNF and M-OPEFB-CNF. Subsequently, the isolated M-OPEFB-CNF composite was utilized for the adsorption of Cr(VI) and Cu(II) from aqueous solution with varying parameters, such as pH, adsorbent doses, treatment time, and temperature. Results showed that the M-OPEFB-CNF as an effective bio-sorbent for the removal of Cu(II) and Cr(VI) from aqueous solution. The adsorption isotherm modeling revealed that the Freundlich equation better describes the adsorption of Cu(II) and Cr(VI) on M-OPEFB-CNF composite. The kinetics studies revealed the pseudo-second-order kinetics model was a better-described kinetics model for the removal of Cu(II) and Cr(VI) using M-OPEFB-CNF composite as bio-sorbent. The findings of the present study showed that the M-OPEFB-CNF composite has the potential to be utilized as a bio-sorbent for heavy metals removal.
    Matched MeSH terms: Chromium
  6. Garba J, Samsuri WA, Othman R, Hamdani MSA
    Sci Rep, 2019 11 27;9(1):17689.
    PMID: 31776374 DOI: 10.1038/s41598-019-54079-0
    Glyphosate (GLY) is a major herbicide used throughout the world, and its continuous application has become an environmental issue. Adsorption is an important mechanism for removing organic contaminant in water. The present study characterized cow dung (CD) and rice husk ash (RHA), and determined the adsorption-desorption of GLY and its metabolite, aminomethylphoshonic acid (AMPA), on to them. The results revealed that both CD and RHA were alkaline and had no or low content of arsenic, cadmium, chromium and lead. The CD had lower surface area (13.104 mg2g-1) than RHA (21.500 m2g-1). The CD contained amines, phenol, ethers and carboxylic functional groups, while in addition to carboxylic and ether, RHA contains siloxane. Both CD and RHA had high affinities for GLY and AMPA. The Freundlich sorption coefficient (Kf) on AMPA were 2.915 and 2.660 for CD and RHA, respectively, while the values on GLY were 1.168 and 1.166 (mg g-1) for CD and RHA, respectively. Desorption of GLY only occurred at lower concentrations, while no desorption of AMPA was recorded, indicating their strong adsorption on CD and RHA. Considering their availabilities and affordable prices, both CD and RHA can be recommended as economical adsorbent for the removal of GLY and AMPA.
    Matched MeSH terms: Chromium
  7. Quadras DD, Nayak USK, Kumari NS, Priyadarshini HR, Gowda S, Fernandes B
    Dent Res J (Isfahan), 2019 7 16;16(4):209-215.
    PMID: 31303873
    Background: Fixed orthodontic appliances can release metal ions such as nickel, chromium, and zinc into saliva and blood, which can cause contact dermatitis, hypersensitivity, and cytotoxicity. This study was undertaken to assess the release of nickel, chromium, and zinc in saliva and serum of patients undergoing fixed orthodontic treatment.

    Materials and Methods: This in vivo study was conducted on 80 participants with an age range of 15-40 years. Thirty were included as controls and 50 participants were treated with fixed orthodontic appliances. Saliva and blood samples were collected at five different periods, before insertion of fixed orthodontic appliance and at 1 week, 3 months, 1 year, and 1.5 years after insertion of appliance, respectively. The metal ion content in the samples were analyzed by atomic absorption spectrophotometry. Mean levels of nickel, chromium, and zinc in saliva and serum were compared between groups using independent sample t-test and before and after results using paired t-test. P < 0.05 was considered as statistically significant.

    Results: At the end of 1.5 years, the mean salivary levels of nickel, chromium, and zinc in controls were 5.02 ppb, 1.27 ppb, and 10.24 ppb, respectively, as compared to 67 ppb, 30.8 ppb, and 164.7 ppb at the end of 1.5 years. This was statistically significant with P < 0.001. A significant increase in the metal ion levels were seen in participants with before and after insertion of appliance (P < 0.001).

    Conclusion: Orthodontic appliances do release considerable amounts of metal ions such as nickel, chromium, and zinc in saliva and serum. However, it was within permissible levels and did not reach toxic levels.

    Matched MeSH terms: Chromium
  8. Iqbal F, Ayub Q, Wilson R, Song BK, Talei A, Yeong KY, et al.
    Environ Monit Assess, 2021 Mar 30;193(4):237.
    PMID: 33783594 DOI: 10.1007/s10661-021-08966-7
    A widely distributed urban bird, the house crow (Corvus splendens), was used to assess bioavailable heavy metals in urban and rural environments across Pakistan. Bioaccumulation of arsenic (As), zinc (Zn), lead (Pb), cadmium (Cd), nickel (Ni), iron (Fe), manganese (Mn), chromium (Cr), and copper (Cu) was investigated in wing feathers of 96 crows collected from eight locations and categorized into four groups pertaining to their geographical and environmental similarities. Results revealed that the concentrations of Pb, Ni, Mn, Cu, and Cr were positively correlated and varied significantly among the four groups. Zn, Fe, Cr, and Cu regarded as industrial outputs, were observed in birds both in industrialized cities and in adjoining rural agricultural areas irrigated through the Indus Basin Irrigation System. Birds in both urban regions accrued Pb more than the metal toxicity thresholds for birds. The house crow was ranked in the middle on the metal accumulation levels in feathers between highly accumulating raptor and piscivore and less contaminated insectivore and granivore species in the studied areas,. This study suggests that the house crow is an efficient bioindicator and supports the feasibility of using feathers to discriminate the local pollution differences among terrestrial environments having different levels and kinds of anthropogenic activities.
    Matched MeSH terms: Chromium
  9. Zakaria A, Ho YB
    Regul Toxicol Pharmacol, 2015 Oct;73(1):191-5.
    PMID: 26190304 DOI: 10.1016/j.yrtph.2015.07.005
    This study aimed to determine the heavy metals (lead, cadmium, and chromium) concentration in lipsticks of different price categories sold in the Malaysian market and evaluate the potential health risks due to daily ingestion of heavy metals in lipsticks. A total of 374 questionnaires were distributed to the female staff in a public university in Malaysia in order to obtain information such as brand and price of the lipsticks, body weight, and frequency and duration of wearing lipstick. This information was important for the calculation of hazard quotient (HQ) in health risk assessment. The samples were extracted using a microwave digester and analyzed using Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The concentrations of lead, cadmium, and chromium in lipsticks ranged from 0.77 to 15.44 mg kg(-1), 0.06-0.33 mg kg(-1), and 0.48-2.50 mg kg(-1), respectively. There was a significant difference of lead content in the lipsticks of different price categories. There was no significant non-carcinogenic health risk due to the exposure of these heavy metals through lipstick consumption for the prolonged exposure of 35 years (HQ < 1).
    Matched MeSH terms: Chromium
  10. Revathi M, Sivagaami Sundari G, Ahmed Basha C, Alam M, Sagadevan S, Ahmad N
    J Nanosci Nanotechnol, 2020 10 01;20(10):6547-6554.
    PMID: 32385012 DOI: 10.1166/jnn.2020.18562
    This investigation aims at the reclamation of Cr(VI) from synthetic electroplating industrial effluent by electroextraction process namely electrochemical ion exchange (EIX). An electrochemical ion exchange reactor of desired dimensions was fabricated with the help of ion-permeable membranes, stainless steel cathode and PbO₂ coated Ti expanded mesh anode. The performance of the reactor was studied in batch recirculation mode, continuous flow mode at different experimental conditions. The influence of various experimental factors, for instance, initial metal ion concentration (20, 300, 1000 mg/L of Cr(VI)), applied voltages (2.5 V, 5 V, 7.5 V, 10 V) and flow rates of the process stream (2, 4, 6, 8, 10, 12 and 14 ml/min) on removal/reclamation efficiency was deliberated. For comparison purposes, an electrodialysis process was conducted at the same optimal conditions. It was found that the EIX process with three compartments has more removal efficiency at optimum experimental conditions than the electrodialysis process. The continuous flow process of the reactor with 300 mg/L of Cr(VI) as inlet concentration has studied to predict the breakeven point of the reactor. It was noted that Cr(VI) ion concentration in the treated wastewater is almost zero up to the discharge of 20 liters of treated rinse water.
    Matched MeSH terms: Chromium
  11. Khairul Nizar Ismail, Kamarudin Hussin, Mohd Sobri Idris
    MyJurnal
    Fly ash is the finely divided mineral residue resulting from the combustion of coal in electric generating plants. Fly ash consists of inorganic, incombustible matter present in the coal that has been fused during combustion into a glassy, amorphous structure. Fly ash particles are generally spherical in shape and range in size from 2 μm to 10 μm. They consist mostly of silicon dioxide (SiO2), aluminium oxide (Al2O3) and iron oxide (Fe2O3). Fly ash like soil contains trace concentrations of the following heavy metals: nickel, vanadium, cadmium, barium, chromium, copper, molybdenum, zinc and lead. The chemical compositions of the sample have been examined and the fly ash are of ASTM C618 Class F.
    Matched MeSH terms: Chromium
  12. Mahmood, W.A., Mohd. Sidek, M.F.
    Ann Dent, 2001;8(1):-.
    MyJurnal
    This is a preliminary survey on cast partial denture designs in the commercial dental laboratories. This survey was carried out for a month in three commercial dental laboratories in Klang Valley and Shah Alam which produce metal dentures in cobalt-chromium. One hundred and ten questionnaires with the designs were collected and analysed. The framework design on the cast was transferred into the design sheet section of the questionnaire. The aim was to investigate communication regarding denture design between clinicians and dental technician and the dentists' dependency on the technician. The design of cobalt-chromium partial dentures in relation to oral health was also assessed. The results indicated that 43.6% of the dentist who used the three laboratories delegated their removable partial design work to the dental technician. More than half of the dentists had some communication with the technicians, and only 18.2 % of the dentists prescribed clear instructions with details of components regarding denture design. Continuing dental education on partial denture design for both clinicians and dental technicians would be of value to provide reinforcement in the knowledge of the basic concept on denture designing. Communication and understanding between both parties would probably improve the quality of cobalt-chromium dentures constructed.
    Matched MeSH terms: Chromium
  13. Abo-Shakeer, L.K.A., Rahman, M.F.A., Yakasai, H., Syed, M.A., Shukor M.Y., Bakar, N.A., et al.
    MyJurnal
    Bacterial based remediation of environmental toxicants is a promising innovative technology
    for molybdenum pollution. To date, the enzyme responsible for molybdate reduction to Moblue
    from bacteria show that the Michaelis-Menten constants varies by one order of magnitude.
    It is important that the constants from newer enzyme sources be characterized so that a
    comparison can be made. The aim of this study is to characterize kinetically the enzyme from a
    previously isolated Mo-reducing bacterium; Bacillus pumilus strain Lbna. The maximum
    activity of this enzyme occurred at pH 5.5 and in between 25 and 35 oC. The Km and Vmax of
    NADH were 6.646 mM and 0.057 unit/mg enzyme, while the Km and Vmax of LPPM were 3.399
    mM and 0.106 unit/mg enzyme. The results showed that the enzyme activity for Bacillus
    pumilus strain Lbna were inhibited by all heavy metals used. Zinc, copper, silver, chromium,
    cadmium and mercury all caused more than 50% inhibition to the Mo-reducing enzyme activity
    with copper being the most potent with an almost complete inhibition of enzyme activity
    observed.
    Matched MeSH terms: Chromium
  14. Siti Hanna Elias, Maketab Mohamed, Aznah Nor-Anuar, Khalida Muda, Mohd Arif Hakimi Mat Hassan, Mohd. Nor Othman, et al.
    Sains Malaysiana, 2014;43:1397-1403.
    In the present study, capability of water hyacinth in removing heavy metals such as Cadmium (Cd), Chromium (Cr), Copper (Cu), Zinc (Zn), Iron (Fe), and Boron (B) in ceramic wastewater was investigated. The metal removal efficiency was identified by evaluating the translocation of metals in roots, leaves and shoot of water hyacinth. The heavy metal removal efficiency followed the order Fe>Zn>Cd>Cu>Cr>B during the treatment process. Water hyacinth had luxury consumption of those 6 elements. This study used the circulation system with 3 columns of plants which functioned as bioremediation of the sample. The concentration of metals in roots is much higher 10 times than leaves and stems. Roots give the result of metalR>metalL. The removal concentration from water hyacinth was estimated under pH of 8.21 to 8.49. This study proves water hyacinth to be a best plant for phytoremediation process
    Matched MeSH terms: Chromium
  15. Mohamed Abdulmunem, Hadijah Binti Abdullah, Noor Hayaty Binti Abu Kasim, Ali Dabbagh
    Sains Malaysiana, 2015;44:1189-1194.
    The aim of this study was to investigate the simultaneous influence of various dental posts and cementation materials on the fracture resistance and failure mode of the endodontically-treated teeth. Sixty endodontically treated upper central incisors were randomly divided into two main groups, each consisted of three subgroups restored with titanium, fiber and stainless steel posts. The posts in the first and second groups were luted with zinc phosphate and composite resin cements, respectively. Composite cores were built-up over the specimens and then retained with nickel-chromium crowns. Specimens were thermocycled and then loaded at 135o until failures were observed. The obtained data of fracture resistances and failure modes were analyzed using Two-way ANOVA and the Chi-Square tests, respectively. The results showed that the zinc phosphate cement resulted in relatively higher fracture resistances. However, luting of dental posts with composite resin provided more restorable failures in endodontically-treated teeth. Moreover, the teeth restored by fiber posts exhibited desirable fracture resistances with more restorable failure modes, compared with those restored by titanium or stainless steel posts.
    Matched MeSH terms: Chromium
  16. Salihu SO, Bakar NKA
    Talanta, 2018 May 01;181:401-409.
    PMID: 29426532 DOI: 10.1016/j.talanta.2018.01.041
    In this study, a simple sample preparation method was developed for the determination of tri-and hexavalent chromium in water samples. It utilizes a pre-heated customized glass tube (CGT), to supply the heat energy required for the reaction of Cr(III) with ammonium pyrrolidinedithiocarbamate (APDC). The products of the Cr complexes, tris(1-pyrrolidinecarbodithioato)chromium(III) and bis(1-pyrrolidinecarbodithioato)[1-pyrrolidinecarbodithio(thioperoxoato)]chromium(III) were chromatographed with Shimadzu LC-20AT and Zobax Eclipse C18 (150mm × 4.6mm, 5µm) column using ACN: Water, (7:3, v/v) as the mobile phase. The concentration of Cr(III) ranged from 0.06mgL-1to 0.09mgL-1and that of Cr(VI) was between 0.02mgL-1to 0.04mgL-1in the samples. Percentage recoveries from spiked real samples were between 87% (tap water) to 110% (wastewater) for Cr(III) and 92% (pond water) to 117% (tap water) for Cr(VI). The limits of detection (LODs) were 0.0029mgL-1and 0.0014mg/L-1for Cr(III) Cr(VI) respectively. While the limits of quantitation (LOQs), were 0.0098mgL-1and 0.0047mgL-1for Cr(III) and Cr(VI) respectively. Method precision (RSD (%)) was 3.3% and 3.5% for Cr(III) and Cr(VI) respectively. The developed method was applied for the speciation analysis of chromium in drinking water, tap water, wastewater, river water, and pond water samples. Our findings proved the method is simple and inexpensive. The method was validated by the analysis of a certified reference material (CRM) SLRS-4. The percentage recovery and RSD(%) from the spiked CRM were 91% and 115% and 0.32% and 1.4% for Cr(III) and Cr(VI) respectively.
    Matched MeSH terms: Chromium
  17. Yusuff AS, Gbadamosi AO, Lala MA, Ngochindo JF
    Environ Sci Pollut Res Int, 2018 Jul;25(19):19143-19154.
    PMID: 29725925 DOI: 10.1007/s11356-018-2075-2
    In this study, adsorption behavior of anthill-eggshell composite (AEC) for the removal of hexavalent chromium (Cr6+) from aqueous solution was investigated. The raw AEC sample was thermally treated at 864 °C for 4 h and characterized using Brunauer-Emmett-Teller (BET), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD), and X-ray fluorescence (XRF) techniques. The effects of adsorption process variables including initial Cr6+ concentration, contact time, and adsorbent dosage on the Cr6+ removal efficiency were investigated using central composite design (CCD) of response surface methodology (RSM). Equilibrium adsorption isotherm and kinetic were also studied. From the analysis of variance (ANOVA), the three variables proved to be significant and the optimum conditions for Cr6+ adsorption were obtained to be 150 mg/L initial Cr6+ concentration, 45.04-min contact time, and 0.5 g adsorbent dosage, which resulted in 86.21% of Cr6+ adsorbed. Equilibrium isotherm study showed that Freundlich model fitted well to the experimental data. The pseudo-second-order kinetic model appeared to better describe the experimental data. The study showed that mixed anthill-eggshell is a promising adsorbent for removing Cr6+ from aqueous solution.
    Matched MeSH terms: Chromium
  18. Mohd Nani SZ, Majid FA, Jaafar AB, Mahdzir A, Musa MN
    PMID: 28105060 DOI: 10.1155/2016/6520475
    Deep sea water (DSW) commonly refers to a body of seawater that is pumped up from a depth of over 200 m. It is usually associated with the following characteristics: low temperature, high purity, and being rich with nutrients, namely, beneficial elements, which include magnesium, calcium, potassium, chromium, selenium, zinc, and vanadium. Less photosynthesis of plant planktons, consumption of nutrients, and organic decomposition have caused lots of nutrients to remain there. Due to this, DSW has potential to become a good source for health. Research has proven that DSW can help overcome health problems especially related to lifestyle-associated diseases such as cardiovascular disease, diabetes, obesity, cancer, and skin problems. This paper reviews the potential health benefits of DSW by referring to the findings from previous researches.
    Matched MeSH terms: Chromium
  19. Rafatullah M, Sulaiman O, Hashim R, Ahmad A
    J Hazard Mater, 2009 Oct 30;170(2-3):969-77.
    PMID: 19520510 DOI: 10.1016/j.jhazmat.2009.05.066
    The present study proposed the use of meranti sawdust in the removal of Cu(II), Cr(III), Ni(II) and Pb(II) ions from synthetic aqueous solutions. Batch adsorption studies showed that meranti sawdust was able to adsorb Cu(II), Cr(III), Ni(II) and Pb(II) ions from aqueous solutions in the concentration range 1-200mg/L. The adsorption was favoured with maximum adsorption at pH 6, whereas the adsorption starts at pH 1 for all metal ions. The effects of contact time, initial concentration of metal ions, adsorbent dosage and temperature have been reported. The applicability of Langmuir, Freundlich, and Dubinin-Radushkevich (D-R) isotherm was tried for the system to completely understand the adsorption isotherm processes. The adsorption kinetics tested with pseudo-first-order and pseudo-second-order models yielded high R(2) values from 0.850 to 0.932 and from 0.991 to 0.999, respectively. The meranti sawdust was found to be cost effective and has good efficiency to remove these toxic metal ions from aqueous solution.
    Matched MeSH terms: Chromium/isolation & purification
  20. Shuhaimi-Othman M, Mushrifah I, Lim EC, Ahmad A
    Environ Monit Assess, 2008 Aug;143(1-3):345-54.
    PMID: 17987397
    Water from 15 sampling stations in Tasik Chini (Chini Lake), Peninsular Malaysia were sampled for 12 months from September 2004 until August 2005 and analyzed for 11 metals including iron (Fe), aluminum (Al), manganese (Mn), barium (Ba), zinc (Zn), lead (Pb), copper (Cu), cadmium (Cd), nickel (Ni), chromium (Cr) and cobalt (Co). Results showed that the mean (min-max) metal concentrations (in micrograms per liter) in Tasik Chini waters for the 12 months sampling based on 15 sampling stations (in descending order) for Fe, Al, Mn, Ba, Zn, Pb, Cu and Cd were 794.84 (309.33-1609.07), 194.53 (62.37-665.93), 29.16 (16.68-79.85), 22.07 (15.64-29.71), 5.12 (2.224-6.553), 2.36 (1.165-4.240), 0.832 (0.362-1.443) and 0.421 (0.254-0.696) respectively. Concentration for three metals i.e. Ni, Cr and Co were too low and not detected by the graphite furnace Atomic Absorption Spectrophotometry (AAS). Comparison with various water quality standards showed that the mean metals concentration in surface water of Tasik Chini were low and within the range of natural background except for Fe and Al. In general, metal concentrations in Tasik Chini water varied temporally and spatially. The main factors influencing these metal concentrations in the water were the raining season and mining activities. Stations located at Tanjung Jerangking and Melai areas were the most effected due to those factors.
    Matched MeSH terms: Chromium/analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links