Displaying publications 81 - 100 of 1043 in total

Abstract:
Sort:
  1. Yap KL, Ooi YE, Khor CM, Wong SH
    Malays J Pathol, 1992 Dec;14(2):105-10.
    PMID: 1338997
    The group A rotavirus staphylococcal co-agglutination test was evaluated and its sensitivity and specificity compared with an in-house enzyme-linked immunosorbent assay (ELISA) and a commercial latex agglutination test (Rotalex). In addition, the storage stability of the staphylococcal reagents was ascertained. Examination of 136 clarified suspensions of diarrhoeal faeces by the staphylococcal co-agglutination test revealed a high proportion of false positives (26%) and uninterpretable results (34%) due to non-specific agglutination. Non-specific agglutination could be removed effectively by prior absorption of the clarified faecal specimens with unsensitized staphylococci. The staphylococcal co-agglutination test was less sensitive and specific than the in-house enzyme-linked immunosorbent assay but was comparable to the Rotalex slide latex agglutination test. The staphylococcal reagents have a shelf life of at least 29 weeks.
    Matched MeSH terms: Sensitivity and Specificity
  2. Hooi YT, Ong KC, Tan SH, Perera D, Wong KT
    Lab Invest, 2020 Sep;100(9):1262-1275.
    PMID: 32601355 DOI: 10.1038/s41374-020-0456-x
    Coxsackievirus A16 (CV-A16) is one of the major causes of mild and self-limiting hand-foot-and-mouth disease (HFMD) in young children, which may occasionally leads to serious neurological complications. In this study, we had developed a novel, consistent, orally infected CV-A16 HFMD hamster model with encephalomyelitis. Four groups of 7-day-old hamsters in a kinetic study were orally infected with mouse-adapted CV-A16 strains and sacrificed at 1-4 days post infection (dpi), respectively. Tissues were studied by light microscopy, immunohistochemistry to detect viral antigens, in situ hybridization to detect viral RNA, and by viral titration. In a separate transmission experiment, orally infected index hamsters were housed together with contact hamsters to investigate oral and fecal viral shedding by virus culture and reverse transcription polymerase chain reaction (RT-PCR). At severe infection/death endpoints, index and contact hamster infection were also histopathologically analyzed. In the kinetic study, infected hamsters developed signs of infection at 4 dpi. Viral antigens/RNA were localized to brainstem (medulla/pons; reticular formation and motor trigeminal nucleus) and spinal cord anterior horn neurons, oral squamous epithelia and epidermis from 3 to 4 dpi. Salivary and lacrimal glands, myocardium, brown adipose tissue, intestinal smooth muscle, and skeletal muscle infection was also demonstrated. Viremia at 1 dpi and increasing viral titers in various tissues were observed from 2 dpi. In the transmission study, all contact hamsters developed disease 3-5 days later than index hamsters, but demonstrated similar histopathological findings at endpoint. Viral culture and RT-PCR positive oral washes and feces confirmed viral shedding. Our hamster model, orally infected by the natural route for human infection, confirmed CV-A16 neurotropism and demonstrated squamous epitheliotropism reminiscent of HFMD, attributes not found in other animal models. It should be useful to investigate neuropathogenesis, model person-to-person transmission, and for testing antiviral drugs and vaccines.
    Matched MeSH terms: Sensitivity and Specificity
  3. Eu LC, Ong KC, Hiu J, Vadivelu J, Nathan S, Wong KT
    Mod Pathol, 2014 May;27(5):657-64.
    PMID: 24186135 DOI: 10.1038/modpathol.2013.184
    Burkholderia pseudomallei causes a potentially fatal infection called melioidosis. We have developed a nonfluorescent, colorimetric in situ hybridization assay using a specific probe to target 16s rRNA of B. pseudomallei in formalin-fixed, paraffin-embedded infected tissues for diagnostic purposes and to study infectious disease pathology. A 63-base pair DNA probe was synthesized and labeled with digoxigenin by PCR. Probe specificity was confirmed by BLAST analysis and by testing on appropriate microbial controls. The in situ hybridization assay was specifically and consistently positive for B. pseudomallei, showing strongly and crisply stained, single bacillus and bacilli clusters in mainly inflamed tissues in seven human acute melioidosis cases and experimentally infected mouse tissues. Intravascular and extravascular bacilli were detected in both intracellular and extracellular locations in various human organs, including lung, spleen, kidney, liver, bone marrow, and aortic mycotic aneurysm, particularly in the inflamed areas. Intravascular, intracellular bacteria in melioidosis have not been previously reported. Although the identity of infected intravascular leukocytes has to be confirmed, extravascular, intracellular bacilli appear to be found mainly within macrophages and neutrophils. Rarely, large intravascular, extracellular bacillary clusters/emboli could be detected in both human and mouse tissues. B. cepacia and non-Burkholderia pathogens (16 microbial species) all tested negative. Nonpathogenic B. thailandensis showed some cross-hybridization but signals were less intense. This in situ hybridization assay could be usefully adapted for B. pseudomallei identification in other clinical specimens such as pus and sputum.
    Matched MeSH terms: Sensitivity and Specificity
  4. Zainol Rashid Z, Othman SN, Abdul Samat MN, Ali UK, Wong KK
    Malays J Pathol, 2020 Apr;42(1):13-21.
    PMID: 32342927
    INTRODUCTION: The World Health Organization (WHO) declared COVID-19 outbreak as a world pandemic on 12th March 2020. Diagnosis of suspected cases is confirmed by nucleic acid assays with real-time PCR, using respiratory samples. Serology tests are comparatively easier to perform, but their utility may be limited by the performance and the fact that antibodies appear later during the disease course. We aimed to describe the performance data on serological assays for COVID-19.

    MATERIALS AND METHODS: A review of multiple reports and kit inserts on the diagnostic performance of rapid tests from various manufacturers that are commercially available were performed. Only preliminary data are available currently.

    RESULTS: From a total of nine rapid detection test (RDT) kits, three kits offer total antibody detection, while six kits offer combination SARS-CoV-2 IgM and IgG detection in two separate test lines. All kits are based on colloidal gold-labeled immunochromatography principle and one-step method with results obtained within 15 minutes, using whole blood, serum or plasma samples. The sensitivity for both IgM and IgG tests ranges between 72.7% and 100%, while specificity ranges between 98.7% to 100%. Two immunochromatography using nasopharyngeal or throat swab for detection of COVID-19 specific antigen are also reviewed.

    CONCLUSIONS: There is much to determine regarding the value of serological testing in COVID-19 diagnosis and monitoring. More comprehensive evaluations of their performance are rapidly underway. The use of serology methods requires appropriate interpretations of the results and understanding the strengths and limitations of such tests.

    Matched MeSH terms: Sensitivity and Specificity
  5. Chan WK, Nik Mustapha NR, Mahadeva S, Wong VW, Cheng JY, Wong GL
    J Gastroenterol Hepatol, 2018 Oct;33(10):1787-1794.
    PMID: 29603365 DOI: 10.1111/jgh.14150
    BACKGROUND AND AIM: There are limited studies on controlled attenuation parameter (CAP) using Fibroscan XL probe for the diagnosis of hepatic steatosis grade. The aim of this study was to determine whether previously defined optimal cut-offs for CAP using the M probe could be applied for the XL probe.

    METHODS: Adult patients with chronic liver disease who had a liver biopsy and examination with both the M and XL probes were included. Previously defined optimal cut-offs for CAP using the M probe were used for the diagnosis of steatosis grades ≥S1, ≥S2, and S3 (248, 268, and 280 dB/m, respectively).

    RESULTS: Data for 180 patients were analyzed (mean age 53.7 ± 10.8 years; central obesity 84.5%; non-alcoholic fatty liver disease 86.7%). The distribution of steatosis grades was S0, 9.4%; S1, 28.3%; S2, 43.9%, and S3, 18.3%. The sensitivity, specificity, positive predictive value, and negative predictive value of CAP using the M/XL probe for the diagnosis of steatosis grade ≥S1 was 93.9%/93.3%, 58.8%/58.8%, 95.6%/95.6%, and 50.0%/47.6%, respectively. These values were 94.6%/94.6%, 41.2%/44.1%, 72.6%/73.6%, and 82.4%/83.3%, respectively, for ≥S2, and 87.9%/87.9%, 27.2%/27.9%, 21.3%/21.5%, and 90.9%/91.1%, respectively, for S3.

    CONCLUSION: The same cut-off values for CAP may be used for the M and XL probes for the diagnosis of hepatic steatosis grade.

    Matched MeSH terms: Sensitivity and Specificity
  6. Teng CL, Wong CH
    Malays Fam Physician, 2013;8(3):26-27.
    PMID: 25883762 MyJurnal
    A 21-year old medical student consults the doctor for a fever that started 3 days ago. The fever was high grade and associated with generalised body aches. There was no gum bleeding. He mentioned that mosquito fogging was conducted in his neighbourhood recently.Physical examination revealed an alert conscious young man. Temperature (oral): 38.9 ͦ C, blood pressure 100/70 mmHg, pulse rate 90/min, good volume. Mild flushing was noted. No petechiae were seen in his legs. Tourniquet test was positive.
    Matched MeSH terms: Sensitivity and Specificity
  7. Salih QA, Ramli AR, Mahmud R, Wirza R
    MedGenMed, 2005;7(2):1.
    PMID: 16369380
    Different approaches to gray and white matter measurements in magnetic resonance imaging (MRI) have been studied. For clinical use, the estimated values must be reliable and accurate when, unfortunately, many techniques fail on these criteria in an unrestricted clinical environment. A recent method for tissue clusterization in MRI analysis has the advantage of great simplicity, and it takes the account of partial volume effects. In this study, we will evaluate the intensity of MR sequences known as T1-weighted images in an axial sliced section. Intensity group clustering algorithms are proposed to achieve further diagnosis for brain MRI, which has been hardly studied. Subjective study has been suggested to evaluate the clustering group intensity in order to obtain the best diagnosis as well as better detection for the suspected cases. This technique makes use of image tissue biases of intensity value pixels to provide 2 regions of interest as techniques. Moreover, the original mathematic solution could still be used with a specific set of modern sequences. There are many advantages to generalize the solution, which give far more scope for application and greater accuracy.
    Matched MeSH terms: Sensitivity and Specificity
  8. Karlas T, Petroff D, Sasso M, Fan JG, Mi YQ, de Lédinghen V, et al.
    Aliment Pharmacol Ther, 2018 Apr;47(7):989-1000.
    PMID: 29446106 DOI: 10.1111/apt.14529
    BACKGROUND: Liver fibrosis is often accompanied by steatosis, particularly in patients with non-alcoholic fatty liver disease (NAFLD), and its non-invasive characterisation is of utmost importance. Vibration-controlled transient elastography is the non-invasive method of choice; however, recent research suggests that steatosis may influence its diagnostic performance. Controlled Attenuation Parameter (CAP) added to transient elastography enables simultaneous assessment of steatosis and fibrosis.

    AIM: To determine how to use CAP in interpreting liver stiffness measurements.

    METHODS: This is a secondary analysis of data from an individual patient data meta-analysis on CAP. The main exclusion criteria for the current analysis were unknown aetiology, unreliable elastography measurement and data already used for the same research question. Aetiology-specific liver stiffness measurement cut-offs were determined and used to estimate positive and negative predictive values (PPV/NPV) with logistic regression as functions of CAP.

    RESULTS: Two thousand and fifty eight patients fulfilled the inclusion criteria (37% women, 18% NAFLD/NASH, 42% HBV, 40% HCV, 51% significant fibrosis ≥ F2). Youden optimised cut-offs were only sufficient for ruling out cirrhosis (NPV of 98%). With sensitivity and specificity-optimised cut-offs, NPV for ruling out significant fibrosis was moderate (70%) and could be improved slightly through consideration of CAP. PPV for significant fibrosis and cirrhosis were 68% and 55% respectively, despite specificity-optimised cut-offs for cirrhosis.

    CONCLUSIONS: Liver stiffness measurement values below aetiology-specific cut-offs are very useful for ruling out cirrhosis, and to a lesser extent for ruling out significant fibrosis. In the case of the latter, Controlled Attenuation Parameter can improve interpretation slightly. Even if cut-offs are very high, liver stiffness measurements are not very reliable for ruling in fibrosis or cirrhosis.

    Matched MeSH terms: Sensitivity and Specificity
  9. Banneheke H, Fernandopulle R, Gunasekara U, Barua A, Fernando N, Wickremasinghe R
    Trop Biomed, 2015 Jun;32(2):192-7.
    PMID: 26691246
    Wet mount microscopy is the most commonly used diagnostic method for trichomoniasis in clinical diagnostic services all over the world including Sri Lanka due to its availability, simplicity and is relatively inexpensive. However, Trichomonas culture and PCR are the gold standard tests. Unfortunately, neither the culture nor PCR is available for the diagnosis of trichomoniasis in Sri Lanka. Thus, it is important to validate the wet mount microscopy as it is the only available diagnostic test and has not been validated to date in Sri Lanka. The objective was to evaluate the validity and reliability of wet mount microscopy against gold standard Trichomonas culture among clinic based population of reproductive age group women in Western province, Sri Lanka. Women attending hospital and institutional based clinics were enrolled. They were interviewed and high vaginal swabs were taken for laboratory diagnosis by culture and wet mount microscopy. There were 601 participants in the age group of 15-45 years. Wet mount microscopy showed 68% sensitivity, 100% specificity, 100% positive (PPV) and 98% negative predictive values (NPV) (P=0.001, kappa=0.803) respectively against the gold standard culture. The area under the ROC curve was 0.840. Sensitivity of wet mount microscopy is low. However it has high validity and reliability as a specific diagnostic test for trichomoniasis. If it is to be used among women of reproductive age group in Western province, Sri Lanka, a culture method could be adopted as a second test to confirm the negative wet mount for symptomatic patients.
    Matched MeSH terms: Sensitivity and Specificity
  10. Naing C, Htet NH, Aye SN, Aung HH, Tanner M, Whittaker MA
    Malar J, 2022 Feb 16;21(1):50.
    PMID: 35172833 DOI: 10.1186/s12936-022-04082-0
    BACKGROUND: Achieving malaria elimination requires the targeting of the human reservoir of infection, including those patients with asymptomatic infection. The objective was to synthesise evidence on the accuracy of the rapid-onsite diagnostic tests (RDTs) and microscopy for the detection of asymptomatic malaria as part of the surveillance activities in Asian countries.

    METHODS: This was a meta-analysis of diagnostic test accuracy. Relevant studies that evaluated the diagnostic performance of RDTs and microscopy for detection of asymptomatic malaria were searched in health-related electronic databases. The methodological quality of the studies included was assessed using the QUADAS-2 tool.

    RESULTS: Ten studies assessing RDT and/or microscopy were identified. The diagnostic accuracies in all these studies were verified by PCR. Overall, the pooled sensitivities of RDT, as well as microscopy for detection of any malaria parasites in asymptomatic participants, were low, while their pooled specificities were almost ideal. For the detection of Plasmodium falciparum, pooled sensitivity by RDT (59%, 95%CI:16-91%) or microscopy (55%, 95%CI: 25-82%) were almost comparable. For detection of Plasmodium vivax, pooled sensitivity of RDT (51%, 95% CI:7-94%) had also the comparable accuracy of microscopy (54%, 95%CI,11-92%). Of note are the wide range of sensitivity and specificity.

    CONCLUSION: The findings of this meta-analysis suggest that RDTs and microscopy have limited sensitivity and are inappropriate for the detection of asymptomatic Plasmodium infections. Other methods including a combination of PCR-based strategies, Loop-Mediated Isothermal Amplification (LAMP) technique must be considered to target these infections, in order to achieve malaria elimination. However, more data is needed for the wide acceptance and feasibility of these approaches. Studies to explore the role of asymptomatic and sub-patent infections in the transmission of malaria are of critical importance and are recommended.

    Matched MeSH terms: Sensitivity and Specificity
  11. Yoo SJ, Wang LL, Ning HC, Tao CM, Hirankarn N, Kuakarn S, et al.
    J Clin Virol, 2015 Mar;64:20-7.
    PMID: 25728074 DOI: 10.1016/j.jcv.2014.12.015
    Early diagnosis of hepatitis C virus (HCV) infection is essential to allow appropriate treatment and prevent transmission.
    Matched MeSH terms: Sensitivity and Specificity
  12. Noordin R, Itoh M, Kimura E, Abdul Rahman R, Ravindran B, Mahmud R, et al.
    Filaria journal, 2007;6:9.
    PMID: 17961262
    In the global effort to eliminate lymphatic filariasis (LF), rapid field-applicable tests are useful tools that will allow on-site testing to be performed in remote places and the results to be obtained rapidly. Exclusive reliance on the few existing tests may jeopardize the progress of the LF elimination program, thus the introduction of other rapid tests would be useful to address this issue. Two new rapid immunochromatographic IgG4 cassette tests have been produced, namely WB rapid and panLF rapid, for detection of bancroftian filariasis and all three species of lymphatic filaria respectively. WB rapid was developed using BmSXP recombinant antigen, while PanLF rapid was developed using BmR1 and BmSXP recombinant antigens. A total of 165 WB rapid and 276 panLF rapid tests respectively were evaluated at USM and the rest were couriered to another university in Malaysia (98 WB rapid, 129 panLF rapid) and to universities in Indonesia (56 WB rapid, 62 panLF rapid), Japan (152 of each test) and India (18 of each test) where each of the tests underwent independent evaluations in a blinded manner. The average sensitivities of WB rapid and panLF rapid were found to be 97.6% (94%-100%) and 96.5% (94%-100%) respectively; while their average specificities were both 99.6% (99%-100%). Thus this study demonstrated that both the IgG4 rapid tests were highly sensitive and specific, and would be useful additional tests to facilitate the global drive to eliminate this disease.
    Matched MeSH terms: Sensitivity and Specificity
  13. Yodhnu S, Sirikatitham A, Wattanapiromsakul C
    J Chromatogr Sci, 2009 Mar;47(3):185-9.
    PMID: 19298703
    Mangosteen, Garcinia mangostana L., is known as the "Queen of fruits" and can be cultivated in the tropical rainforest such as Malaysia, Indonesia, and Thailand. Compounds isolated from the fruit peel of mangosteen contain abundant xanthones (especially alpha-mangostin). It has been used as traditional medicine such as anti-inflammatory and antibacterial and is popularly applied to cosmetic and pharmaceutical products. However, there is little information for quality and quantity determination of alpha-mangostin in mangosteen. Thus, the aim of this study was to set up a validated and stability-indicated isocratic reverse-phase high-performance liquid chromatographic (HPLC) method for quality control and quantity determination of a-mangostin from mangosteen peel extract. The assay was fully validated and shown to be linear (r(2) > 0.999), sensitive (LOD = 0.02 microg/mL and LOQ = 0.08 microg/mL), accurate (intra-day was between 98.1-100.8%, inter-day was between 90.0-101.3%), precise (intra-day variation < or = 1.8%, inter-day variation < or = 4.3%), specific, and with good recovery. Total analysis was approximately 8 min. The finalized method is also a stability-indicating assay. The present method should be useful for analytical research and for routine quality control analysis of alpha-mangostin in mangosteen peel extract and products of mangosteen.
    Matched MeSH terms: Sensitivity and Specificity
  14. Eamsobhana P, Yong HS, Mak JW, Wattanakulpanich D
    PMID: 9561620
    A dot-blot ELISA was compared with a previously performed sandwich ELISA for the detection of Parastrongylus cantonensis antigens in sera from patients. Using the same monoclonal antibody and the same sera, 6 of 10 sera (60%) from parastronglyiasis patients were positive in dot-blot ELISA, whereas with sandwich ELISA, 5 of the same patient sera (50%) were positive. The specificity in both assays was 100% using 50 sera from patients with other parasitic diseases; of these, 10 each were from patients with cysticercosis, filariasis, gnathostomiasis, malaria and toxocariasis. The control group consisted of 53 sera from normal health Thais and Malaysians. The sensitivity of the assays was, however, slightly better with dot-blot ELISA and because it is simple, quick and cost-effective, it may be a test of choice for specific diagnosis of human parastrongyliasis.
    Matched MeSH terms: Sensitivity and Specificity
  15. Pandarathodiyil AK, Ramanathan A, Garg R, Doss JG, Abd Rahman FB, Ghani WMN, et al.
    Asian Pac J Cancer Prev, 2021 Oct 01;22(10):3227-3235.
    PMID: 34710999 DOI: 10.31557/APJCP.2021.22.10.3227
    BACKGROUND: We examined the lactate dehydrogenase (LDH) enzyme levels in the saliva of vapers (e-cigarette users) and compared the data with cigarette smokers and a control group of non-smokers and non-vapers.

    METHODS: Subjects were recruited among those responding to a social media announcement or patients attending the SEGi Oral Health Care Centre between May and December 2019, and among some staff at the centre. Five ml of unstimulated   whole saliva was collected and salivary LDH enzyme activity levels were measured with a LDH colorimetric assay kit. Salivary LDH activity level was determined for each group and compared statistically.

    RESULTS: Eighty-eight subjects were categorized into three groups (control n=30, smokers n=29, and vapers n=29). The mean ± standard deviation (SD) values for salivary LDH activity levels for vapers, smokers, and control groups were 35.15 ± 24.34 mU/ml, 30.82 ± 20.73 mU/ml, and 21.45 ± 15.30 mU/ml, respectively. The salivary LDH activity levels of smoker and vaper groups were significantly higher than in the control group (p = 0.031; 0.017). There was no significant difference of salivary LDH activity level in vapers when compared with smokers (p= 0.234).

    CONCLUSION: Our findings showed higher LDH levels in the saliva of vapers when compared with controls, confirming cytotoxic and harmful effects of e-cigarettes on the oral mucosa.

    Matched MeSH terms: Sensitivity and Specificity
  16. Yong FL, Law CW, Wang CW
    BMC Cancer, 2013 Jun 08;13:280.
    PMID: 23758639 DOI: 10.1186/1471-2407-13-280
    BACKGROUND: MicroRNAs (miRNAs) are short, non-coding RNA molecules that act as regulators of gene expression. Circulating blood miRNAs offer great potential as cancer biomarkers. The objective of this study was to correlate the differential expression of miRNAs in tissue and blood in the identification of biomarkers for early detection of colorectal cancer (CRC).

    METHODS: The study was divided into two phases: (I) Marker discovery by miRNA microarray using paired cancer tissues (n = 30) and blood samples (CRC, n = 42; control, n = 18). (II) Marker validation by stem-loop reverse transcription real time PCR using an independent set of paired cancer tissues (n = 30) and blood samples (CRC, n = 70; control, n = 32). Correlation analysis was determined by Pearson's test. Logistic regression and receiver operating characteristics curve analyses were applied to obtain diagnostic utility of the miRNAs.

    RESULTS: Seven miRNAs (miR-150, miR-193a-3p, miR-23a, miR-23b, miR-338-5p, miR-342-3p and miR-483-3p) have been found to be differentially expressed in both tissue and blood samples. Significant positive correlations were observed in the tissue and blood levels of miR-193a-3p, miR-23a and miR-338-5p. Moreover, increased expressions of these miRNAs were detected in the more advanced stages. MiR-193a-3p, miR-23a and miR-338-5p were demonstrated as a classifier for CRC detection, yielding a receiver operating characteristic curve area of 0.887 (80.0% sensitivity, 84.4% specificity and 83.3% accuracy).

    CONCLUSION: Dysregulations in circulating blood miRNAs are reflective of those in colorectal tissues. The triple miRNA classifier of miR-193a-3p, miR-23a and miR-338-5p appears to be a potential blood biomarker for early detection of CRC.

    Matched MeSH terms: Sensitivity and Specificity
  17. Gan SH, Ismail R, Wan Adnan WA, Wan Z
    PMID: 12016023
    An HPLC system using a simple liquid-liquid extraction and HPLC with UV detection has been validated to determine tramadol concentration in human plasma. The method developed was selective and linear for concentrations ranging from 10 to 2000 ng/ml with average recovery of 98.63%. The limit of quantitation (LOQ) was 10 ng/ml and the percentage recovery of the internal standard phenacetin was 76.51%. The intra-day accuracy ranged from 87.55 to 105.99% and the inter-day accuracy, 93.44 to 98.43% for tramadol. Good precision (5.32 and 6.67% for intra- and inter-day, respectively) was obtained at LOQ. The method has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.
    Matched MeSH terms: Sensitivity and Specificity
  18. Arabi Z, Aziz NA, Abdul Aziz AF, Razali R, Wan Puteh SE
    BMC Fam Pract, 2013;14:49.
    PMID: 23586732 DOI: 10.1186/1471-2296-14-49
    BACKGROUND: Worldwide, the population is ageing, resulting in an associated increase in dementia prevalence. Forgetfulness in elderly people is often perceived as normal in some local cultures and thus, the early detection of dementia in primary care requires detection of symptoms other than memory complaints.This study was conducted to screen elderly patients for early dementia in primary care using a newly developed Early Dementia Questionnaire (EDQ) and comparing it with a standard assessment tool, the Mini Mental State Examination (MMSE).
    METHODS: A cross-sectional study was conducted on a group of elderly patients using convenience sampling of consecutive patients. Elderly depression was excluded using the Geriatric Depression Scale (GDS). Exclusion criteria also included known cases of dementia. Inclusion criteria included a score of 5 or less in GDS and the presence of a reliable informant. A face-to-face interview was done using the EDQ with the patient and informant to elicit symptoms of early dementia. If the informant was not present, a telephone interview was used instead. The patient was then assessed with the Mini Mental State Examination (MMSE) using a cut-off point of 21.
    RESULTS: Prevalence of dementia among 155 subjects was 52.3% by EDQ and 15.5% by MMSE. The EDQ demonstrated a sensitivity of 79.2% with specificity of 52.7%. Positive predictive value (PPV) of EDQ was 23.5% with the negative predictive value (NPV) of 93.2%. The strongest predictor of possible early dementia was complaints of memory problems (OR 26.22; 95% CI 2.03-338.14) followed by complaints of concentration problems (OR 14.33; 95% CI 5.53-37.12), emotional problems (OR 4.75; 95% CI 1.64-13.81) and sleep disturbances (OR 3.14; 95% CI 1.15-8.56). Socio-demographic factors, medical problems and smoking status were not associated with possible dementia (p>0.05), despite that 60-70% of the elderly had chronic illnesses.
    CONCLUSION: The EDQ is a promising alternative to MMSE for screening of early dementia in primary care.
    Matched MeSH terms: Sensitivity and Specificity
  19. Tan TL, Ahmad NS, Nasuruddin DN, Ithnin A, Tajul Arifin K, Zaini IZ, et al.
    PLoS One, 2016;11(3):e0152065.
    PMID: 27003588 DOI: 10.1371/journal.pone.0152065
    INTRODUCTION: Early diagnosis of sepsis and bacterial infection is imperative as treatment relies on early antibiotic administration. There is a need to develop new biomarkers to detect patients with sepsis and bacterial infection as early as possible, thereby enabling prompt antibiotic treatment and improving the survival rate.

    METHODS: Fifty-one adult patients with suspected bacterial sepsis on admission to the Emergency Department (ED) of a teaching hospital were included into the study. All relevant cultures and serology tests were performed. Serum levels for Group II Secretory Phospholipase A2 (sPLA2-IIA) and CD64 were subsequently analyzed.

    RESULTS AND DISCUSSION: Sepsis was confirmed in 42 patients from a total of 51 recruited subjects. Twenty-one patients had culture-confirmed bacterial infections. Both biomarkers were shown to be good in distinguishing sepsis from non-sepsis groups. CD64 and sPLA2-IIA also demonstrated a strong correlation with early sepsis diagnosis in adults. The area under the curve (AUC) of both Receiver Operating Characteristic curves showed that sPLA2-IIA was better than CD64 (AUC = 0.93, 95% confidence interval (CI) = 0.83-0.97 and AUC = 0.88, 95% CI = 0.82-0.99, respectively). The optimum cutoff value was 2.13μg/l for sPLA2-IIA (sensitivity = 91%, specificity = 78%) and 45 antigen bound cell (abc) for CD64 (sensitivity = 81%, specificity = 89%). In diagnosing bacterial infections, sPLA2-IIA showed superiority over CD64 (AUC = 0.97, 95% CI = 0.85-0.96, and AUC = 0.95, 95% CI = 0.93-1.00, respectively). The optimum cutoff value for bacterial infection was 5.63μg/l for sPLA2-IIA (sensitivity = 94%, specificity = 94%) and 46abc for CD64 (sensitivity = 94%, specificity = 83%).

    CONCLUSIONS: sPLA2-IIA showed superior performance in sepsis and bacterial infection diagnosis compared to CD64. sPLA2-IIA appears to be an excellent biomarker for sepsis screening and for diagnosing bacterial infections, whereas CD64 could be used for screening bacterial infections. Both biomarkers either alone or in combination with other markers may assist in decision making for early antimicrobial administration. We recommend incorporating sPLA2-IIA and CD64 into the diagnostic algorithm of sepsis in ED.

    Matched MeSH terms: Sensitivity and Specificity
  20. Tan SL, Sakinah Harith, Hasmah Abdullah, Wan Nazirah Wan Yusuf
    Sains Malaysiana, 2016;45:1311-1317.
    A local Malnutrition Risk Screening Tool-Hospital (MRST-H) has been developed to identify the risk of malnutrition among hospitalized geriatric patients in Malaysia. The aims of this multicenter study were to evaluate the criterion validity of the MRST-H against the reference standard Subjective Global Assessment (SGA) and revise its scoring criteria among Malaysian geriatric patients. A cross-sectional study was conducted among 542 geriatric patients at eight general hospitals in Peninsular Malaysia from January 2011 to February 2013. The Malay version MRST-H and SGA were administered to all participants through face-to-face interviews. Sensitivity and specificity of MRST-H were established using the Receiver Operating Characteristic (ROC) curves and the optimal cut-off scores were determined. The MRST-H had area under the ROC curve (AUC) values of 0.84 and 0.88 when validated against the SGA-determined malnutrition (SGA B+C) and severe malnutrition (SGA C) status. These high AUC values indicated that the MRST-H has very good overall diagnostic accuracy. However, the original cut-off score of five points for MRST-H has undesirable sensitivity in identifying the malnutrition (sensitivity = 0.12) and severely malnutrition (sensitivity = 0.35) status. The optimal cut-off score of MRST-H in identifying malnourished and severely malnourished participants were both established at the cut-off score of two points. The sensitivity of MRST-H increased substantially at this point without compromising its specificity. Therefore, the established cut-off score of two points with optimal sensitivity and specificity was selected to replace to original cut-off score for screening of risk of malnutrition among hospitalized geriatric patients.
    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links